Search PubMed⌕ Search

Biomedical subjects

Göran Lantz

Publications and source records attributed to Göran Lantz.

4 recordsLinked to original sources

EEG source imaging.

OBJECTIVE: Electroencephalography (EEG) is an important tool for studying the temporal dynamics of the human brain's large-scale neuronal circuits. However, most EEG applications fail to capitalize on all of the data's available information, particularly that concerning the location of active sources in the brain. Localizing the sources of a given scalp measurement is only achieved by solving the so-called inverse problem. By introducing reasonable a priori constraints, the inverse problem can be solved and the most probable sources in the brain at every moment in time can be accurately localized. METHODS AND RESULTS: Here, we review the different EEG source localization procedures applied during the last two decades. Additionally, we detail the importance of those procedures preceding and following source estimation that are intimately linked to a successful, reliable result. We discuss (1) the number and positioning of electrodes, (2) the varieties of inverse solution models and algorithms, (3) the integration of EEG source estimations with MRI data, (4) the integration of time and frequency in source imaging, and (5) the statistical analysis of inverse solution results. CONCLUSIONS AND SIGNIFICANCE: We show that modern EEG source imaging simultaneously details the temporal and spatial dimensions of brain activity, making it an important and affordable tool to study the properties of cerebral, neural networks in cognitive and clinical neurosciences.

Brain↗

Propagation of interictal epileptiform activity can lead to erroneous source localizations: a 128-channel EEG mapping study.

The relationship between interictal epileptiform activity and the epileptogenic zone is complex. Despite the fact that intraspike propagation may occur, the peak of the spike is often used as indicator of the site of ictal onset. In this investigation, spatio-temporal segmentation was used to demonstrate this intraspike propagation and to determine at which time point the voltage pattern corresponded best to the epileptogenic zone. Sixteen patients with focal epilepsy were recorded with 125-channel EEG. Between one and five different map topographies were identified during the rising phase of the spike. A distributed source model (EPIFOCUS) was used to localize the source of each map, and the distance from the EPIFOCUS maximum to the anatomic lesion was calculated. In only 3 of 16 cases was the entire rising phase of the spike accounted for by one single map. In another five patients, several maps were obtained, although all were located within the epileptogenic lesion. In the remaining eight patients, however, parts of the rising phase had locations outside the epileptogenic lesion. On the average, 80% of the rising time had within lesion locations the most reliable time period being halfway between onset and peak. The results illustrate that intraspike propagation has to be considered in source localizations, and they also illustrate the usefulness of spatio-temporal segmentation for visualizing this propagation.

Adolescent↗

128-channel EEG source imaging in epilepsy: clinical yield and localization precision.

The authors evaluated the feasibility, clinical yield, and localization precision of high-resolution EEG source imaging of interictal epileptic activity. A consecutive series of 44 patients with intractable epilepsy of various causes, who underwent a comprehensive presurgical epilepsy evaluation, were subjected to a 128-channel EEG recording. A standardized source imaging procedure constrained to the individual gray matter was applied to the averaged spikes of each patient. In 32 patients, the presurgical workup identified a focal epileptogenic area. The 128-channel EEG source imaging correctly localized this area in 30 of these patients (93.7%). Imprecise localization was explained by simplifications of the recordings and analysis procedure, which was accepted for the benefit of speed and standardization. In a subgroup of 24 patients who underwent operations, the sublobar precision of the 128-channel EEG source imaging was evaluated by calculating the distance of the source maximum to the resected area. This analysis revealed zero distance in 19 cases (79%). The authors conclude that high-resolution interictal EEG source imaging is a valuable noninvasive functional neuroimaging technique. The speed, ease, flexibility, and low cost of this technique warrant its use in clinical practice.

Adolescent↗