Search PubMed⌕ Search

Biomedical subjects

G van Kaick

Publications and source records attributed to G van Kaick.

At least 55 records · Page 3Linked to original sources

Pharmacokinetic imaging of 11C ethanol with PET in eight patients with hepatocellular carcinomas who were scheduled for treatment with percutaneous ethanol injection.

PURPOSE: To evaluate the carbon 11 ethanol kinetics with positron emission tomography after intratumoral injection of the tracer and assess its redistribution and dilution in patients who have hepatocellular carcinomas and who were scheduled for treatment with percutaneous ethanol injection. MATERIALS AND METHODS: The study included eight patients with hepatocellular carcinomas. 11C ethanol was administered via a puncture needle positioned with ultrasonographic guidance. Parametric images based on the Fourier transformation were created for further analysis of the local distribution patterns of the tracer. The ratio of the 45-minute postinjection standardized uptake value to the 5-minute postinjection standardized uptake value was used for the evaluation of ethanol dilution. RESULTS: Five of eight tumors demonstrated almost constant uptake values after the initial distribution phase. In contrast, a rapid elimination of the 11C ethanol from the tumor was documented in three of eight tumors. The 45 minute-to-5 minute ratio was 0.18-0.67 (median value, 0.56) in the tumors. The time-activity curves of the normal liver parenchyma increased slowly but steadily with time owing to a low ethanol elimination from the tumor. Fourier transformation demonstrated inhomogeneous parts on the amplitude images in seven of eight tumors and random redistribution on the phase images in six of eight tumors. CONCLUSION: Inhomogeneous drug distribution and drug dilution in the target area are likely to be the major limiting parameters for therapy response.

Aged↗

Renal arteries: optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold.

PURPOSE: To compare two different three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiographic techniques. MATERIALS AND METHODS: In 26 patients suspected of having renal artery stenosis, results with fast multiphase 3D MR angiography were compared to those with standard 3D MR angiography in 37 patients. With both techniques, 31-second breath-hold acquisitions were performed. Multiphase angiography comprised five discrete 6.4-second acquisitions without bolus timing, and standard angiography comprised a single acquisition based on test-bolus timing. Two readers evaluated images obtained with both techniques in terms of image quality, artifacts, and vessel conspicuity. Accuracy of findings on the multiphase 3D MR angiograms for assessment of renal artery stenosis was determined by comparing them to digital subtraction angiograms and surgical findings. RESULTS: In the early arterial phase, multiphase 3D MR angiograms showed no image degradation by venous overlay, whereas standard 3D MR angiograms depicted at least minor overlay in 53 of 83 renal arteries (P < .001). Less parenchymal enhancement in the early arterial phase resulted in a higher vessel conspicuity for the divisions and segmental arteries (P < .001). Both readers detected and correctly graded 18 of 20 stenoses on the multiphase angiograms with almost perfect interobserver agreement (kappa > 0.89). CONCLUSION: Renal multiphase 3D MR angiography is an accurate technique requiring no bolus timing. The performance of early arterial phase imaging leads to improved depiction, particularly of the distal renovascular tree, compared to that with standard single-phase 3D MR angiography.

Adult↗

The german thorotrast study: recent results and assessment of risks.

The German Thorotrast study comprises 2,326 patients and 1,890 controls. Forty-eight Thorotrast patients and 239 controls are still alive and are invited for a follow-up examination every 2 years. In the deceased patients, the following neoplastic diseases with excess rates were registered (Thorotrast/controls): liver cancer (454/3); cancer of the bile ducts, including gallbladder (42/7); myeloid leukemia (40/7); myelodysplastic syndrome (30/4); plasmacytoma (10/2); non-Hodgkin's lymphoma (15/5); bone sarcoma (4/1); malignant peritoneal or pleural mesothelioma (9/0). Dose calculations are based on results of whole-body counting, X-ray films, and data obtained from the hospital records on the volume of Thorotrast injected. For liver cancer, the cumulative risk estimate was calculated to be 40 per 10(4) person Sv (radiation weighting factor = 20). These figures are close to the results of the Danish study and are comparable to the results of the Life Span Study of A-bomb survivors after 40 years at risk with 18 to 48 liver cancers per 10(4) person Sv. For hematopoietic malignancies, the cumulative risk was calculated to be about 7 per 10(4) person Sv (radiation weighting factor = 20). This risk estimate is lower by a factor of 10 compared to the results of the Life Span Study.

Adult↗

Uterine cervical carcinoma: comparison of standard and pharmacokinetic analysis of time-intensity curves for assessment of tumor angiogenesis and patient survival.

Dynamic studies of Gd-based contrast agents in magnetic resonance imaging (MRI) are increasingly being used for tumor characterization as well as for therapy response monitoring. Because detailed knowledge regarding the pathophysiological properties, which in turn are responsible for differences in contrast enhancement, remains fairly undetermined, it was the aim of this study to: (a) examine the association of standard and pharmacokinetic analysis of time-intensity curves in dynamic MRI with histomorphological markers of tumor angiogenesis [microvessel density (MVD) and vascular endothelial growth factor (VEGF)]; and (b) determine the ultimate value of a histomorphological and a dynamic MRI approach by the correlation of those data with disease outcome in patients with primary cancer of the uterine cervix. Pharmacokinetic parameters (amplitude, A; exchange rate constant, k21) and standard parameters [the maximum signal intensity increase over baseline (SI-I) and the steepest signal intensity-upslope per second (SI-U/s)] were calculated from a contrast-enhanced dynamic MRI series in 37 patients with biopsy-proven primary cervical cancer. On the surgical whole mount specimens, histomorphological markers of tumor angiogenesis (MVD and VEGF) were compared to MRI-derived parameters. For MRI and histomorphological data, Kaplan-Meier survival curves were calculated and compared using log-rank statistics. A significant association was found between MVD and A (P < 0.01) and SI-I (P < 0.05). No significant relationships were observed between VEGF expression and all dynamic MRI parameters. Kaplan-Meier curves based on k21 and SI-U/s showed that tumors with high k21 and SI-U/s values had a significantly (P < 0.05 and 0.001, respectively) worse disease outcome than did tumors with low k21 and SI-U/s values. None of the histomorphological gold standard markers for assessing tumor angiogenesis (MVD and VEGF) had any significant power to predict patient survival. It is concluded that in patients with uterine cervical cancer: (a) the pathophysiological basis for differences in dynamic MRI is MVD but not VEGF expression; (b) a functional, dynamic MRI approach (both standard and pharmacokinetic analysis) may be better suited to assess angiogenic activity in terms of patient survival than are the current histomorphological-based markers of tumor angiogenesis; and (c) compared with standard analysis, a simple pharmacokinetic analysis of time-intensity curves is not superior to assess MVD or patient survival.

Contrast Media↗

Assessment of glucosylifosfamide mustard biodistribution in rats with prostate adenocarcinomas by means of in vivo 31P NMR and in vitro uptake experiments.

A combined in vitro/in vivo study was performed to evaluate the possible application of phosphorus (31P) NMR spectroscopy for therapy monitoring and to investigate glucosylifosfamide mustard (Glc-IPM) transport and biodistribution by radiotracer techniques. Dynamic in vivo 31P NMR measurements were performed in rats with prostate adenocarcinoma after i.v. injection of 1 mmol/kg body weight (bw) of ifosfamide (IFO) (n = 4) and 1 mmol/kg bw (n = 4) or 2.15 mmol/kg bw (n = 9) of Glc-IPM. In a biodistribution study with 14C-labeled Glc-IPM and a final dose of 0.8 mmol Glc-IPM/kg bw, the animals were killed 5, 30, 60, and 120 min after drug administration, an ethanol extraction was performed from several tissues, and the dose per g tissue was calculated. The same tumor cell line was used in saturation and competition experiments to further elucidate the transport mechanism. The 31P NMR signals of IFO and Glc-IPM showed no overlap with the endogenous phosphorus peaks. A rapid washout with a half-life between 25.9 +/- 5.6 min for the lower dose and 34.3 +/- 4.2 min for the higher dose of Glc-IPM was observed in the tumor. No statistically significant change of the pH value was observed during the examination period. The beta-nucleoside 5'-triphosphate (NTP)/inorganic phosphate (Pi) signal intensity ratio showed a tendency to decrease but without statistical significance. A rapid elimination was demonstrated by both the noninvasive NMR technique and the biodistribution study. No saturation was found in vitro for the Glc-IPM uptake, even at the concentration of 5 mM. Furthermore, the Glc-IPM uptake was not inhibited by the presence of 2-deoxyglucose and vice versa. The data show that the pharmacokinetics of Glc-IPM in the tumor can be followed in vivo by 31P NMR. The results presented are evidence for diffusion as the transport mechanism for Glc-IPM in this tumor model. However, the better visualization of Glc-IPM as compared to ifosfamide may be due to metabolic trapping of a negatively charged metabolite after deglycosylation.

Adenocarcinoma↗

[Angiogenesis of cervix carcinoma. Contrast enhanced dynamic MRI, histologic quantification of capillary density and lymphatic system infiltration].

PURPOSE: It was the aim of this project to examine (i) the relationships between contrast-enhanced dynamic MR imaging derived characteristics and histologic microvessel density counts--a recognized surrogate of tumor angiogenesis--from tumors in patients with primary or recurrent cancer of the uterine cervix, and (ii) to correlate these parameters with lymphatic involvement (i.e. lymphatic channels) to assess tumor biological aggressiveness in terms of lymphatic spread. MATERIAL AND METHODS: Pharmacokinetic MR imaging parameters (amplitude A, exchange rate constant k21) were derived from contrast-enhanced dynamic MR imaging in thirty-three patients with biopsy proven cancer of the uterine cervix. The pharmacokinetic MR imaging characteristics were correlated to histologic capillary density counts obtained from whole mount specimen. In addition, these data were correlated to the angiogenic activity as a marker for lymphatic system involvement. RESULTS: Pharmacokinetic MR imaging derived parameters (A, k21) showed a weak but significant (p < 0.05) correlation with microvessel density counts. Lymphatic involvement was more comprehensively assessed by the pharmacokinetic parameter k21 compared with histologic microvessel density, resulting in a significantly (p < 0.05) higher overall accuracy (85% vs. 64%), sensitivity (83% vs. 54%), and comparable specificity (89% vs. 89%), respectively. CONCLUSION: Our first results show that the signal-time curves measured by contrast-enhanced MR imaging are only in part influenced by microvessel density. In addition, MR imaging derived characteristics may assess tumor biological aggressiveness in terms of lymphatic spread (i.e. lymphatic channels) more comprehensively than histologic microvessel density in patients with primary or recurrent cancer of the uterine cervix.

Adult↗

[Study design in clinical radiologic research].

PURPOSE: To review important aspects of study design in clinical radiology and to introduce the reader to the requirements of Good Clinical Practice (GCP). METHODS: The European guidelines for GCP, the Declaration of Helsinki, the differentiation into study phases and the authors' own experience in open and sponsored clinical trials are the basis of this analysis. RESULTS: Guideline such as GCP do not limit scientific freedom in research but define high standards for the well-being of patients and volunteers as well as guaranteeing scientific honesty. The benefits of defined data monitoring and the necessity of a prospective statistical concept are frequently underestimated. CONCLUSION: Correct study design has to be expected in radiology too. High standards guarantee accuracy and honesty of scientific studies. Only this can warrant the value for the patient of radiological diagnostics and therapy.

Forecasting↗

[Multiple reader analysis for evaluation of functional MR mammography].

The diagnostic impact and reproducibility of the different methods used within the concept of functional MR-Mammography (FMRM) was assessed by a multi-reader-analysis. By four experienced readers, 100 histologically confirmed cases were evaluated in six different sessions. Per session, one of the following components was analyzed: clinical history (I), static MRM (II), color-coded projection images (III), time-signal curves of contrast enhancement within a large ROI (IV) and the strongest enhancing pixel (V) obtained from the histologically confirmed lesion and the complete FMRM reading (VI). The functional methods (IV-VI) revealed significantly (p < 0.05) higher specificities than the others (I-III). The highest reproducibility between the readers was observed for (IV) phi chi = 0.80, (V) phi chi = 0.76 and FMRM (VI) phi chi = 0.63. These three methods also presented the best ROC-curves and showed the highest complementarity with respect to the false positive classifications in x-ray mammography. FMRM is a reader independent, reproducible method. The analysis of the contrast enhancement time-intensity curves with high temporal resolution allows an improved differentiation of malignant and benign findings.

Adult↗

[A multicenter study of diagnostic criteria in ultrasound mammography. Statistical pitfalls and ways out of the data jungle].

This paper demonstrates the statistical processing of data from a multicentric study. Seventy-seven patients with a suspicious, solid breast mass were included in a two-center study, using clinical breast examination, mammography, and ultrasound. The assessment was formalized using a uniform evaluation sheet. The prospective results of the examinations were compared with the histologic report. The degree of interdependence between an examiner's diagnosis and diagnostic criteria used was assessed using the kappa statistics. We found that despite standardized assessment, the criteria used for differential diagnosis were at least partially different. The criteria valid for diagnosis at both centers were whether a mass fitted well into the surrounding tissue or led to destruction or architectural distortion, whether it was fixed to the surrounding tissues, as assessed by sonopalpation maneuvers, and whether it borders were sharp or unsharp.

Artifacts↗

[MRI imaging of the uterine arterial blood flow in normal and malignant uterine tissue by means of 2d-multiphase tagging technic].

PURPOSE: The aim of this pilot study was to evaluate a 2D-STAR technique as a non contrast-enhanced approach to demonstrate the uterine artery and its branches and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma. MATERIALS AND METHODS: Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by 2D-STAR imaging at different inversion delay times (300 ms-1900 ms) which showed the passage of a blood bolus through normal and malignant tissue of the uterine cervix. RESULTS: The uterine artery was well visualized with short inversion delay times of 300 ms to 500 ms. It was characterized as single or multiple helical loops before dividing into its intracervical branches. The intracervical branching was observed at inversion delay times of 500 ms-700 ms. With longer inversion delay times arterial signal enhancement disappeared and cervical tissue enhancement was noted. Enhancement of benign tissue was observed at inversion delay times of 1100 ms-1700 ms, and in malignant tissue at shorter inversion delay times of 900 ms-1300 ms. The maximum of this diffuse signal enhancement of benign tissue was seen at inversion delay times of 1500 ms (1100 ms-1700 ms), in malignant tissue at significantly (P < 0.05) shorter inversion delay times of 1100 ms (900 ms to 1300). CONCLUSION: Our preliminary results show that the vascular supply and blood flow of the normal uterine cervix and of advanced cervical cancer can be assessed by non contrast-enhanced 2D STAR imaging and that malignant cervical tissue is earlier and stronger perfused than normal cervical tissue.

Adult↗

[Ultrafast MRI phlebography of the lungs].

AIM: Improved detection of pulmonary-venous pathologies by imaging the pulmonary veins without arterial overlay. MATERIAL AND METHODS: Sequential 3D imaging of the pulmonary arterial and arteriovenous phase was performed with an ultrafast 3D FLASH sequence successively acquiring eight 3D data sets every 2.9 s within a single breathhold. For an 8 cm thick 3D slab an interpolated spatial resolution of about 1.4 x 1.9 x 3.3 mm could be achieved. Different protocols for contrast media dose and infusion rate were used. For selective visualization of the pulmonary veins, the pulmonary arterial phase was subtracted from a subsequent arteriovenous phase with the highest venous signal. 5 healthy volunteers, 8 patients with history of a cerebrovascular accident (CVA) of unknown etiology an suspected pulmonary-venous thrombosis and 9 patients with compression of the pulmonary vasculature by centrally growing malignancies were evaluated. RESULTS: With higher infusion rate and lower contrast media dose, arteries and veins could be better separated by their enhancement kinetics. In all cases a complete visualization of the main pulmonary veins, segmental and subsegmental veins up to the fourth order of each lung segment was achieved without any overlay of pulmonary arteries. No thrombi of the pulmonary veins were found in patients with CVA. The obstruction of pulmonary arteries and veins due to vessel compression could be selectively visualized. CONCLUSION: Ultrafast multiphase 3D-Gd-MRA is a new reliable method for selective 3D visualization of pulmonary veins.

Adult↗

[Safety considerations to avoid current-induced skin burns in MRI procedures].

The safety aspects of radiological methods continue to evolve. In this paper we report on two cases of skin burns in MRI caused by induced electrical current. A second- and a third-degree skin burn occurred during imaging in a 1.5 T system. The electromagnetic radiofrequency field inadvertently led to electrical currents caused by a conducting loop through the extremities and trunk. Skin burns induced by electrical current may occur in extremely rare cases even with standard MR imaging protocols operating within all current safety guidelines by inadvertently forming a closed conducting loop. By avoiding focal skin to skin contact of the extremities, this extremely rare adverse event can be avoided.

Adult↗

[Integration of functional and morphologic MRI data for preoperative 3D visualization of tumors. Example: cervical carcinoma].

PURPOSE: The goal of this exemplary study was to integrate morphological and functional MRI to establish computer-based, pre-operative therapy planning for tumors, instancing cervical carcinoma. METHODS: For morphological representation T1-weighted, filtered 3D sequences were investigated within a hierarchical segmentation approach. Using a method for image registration, segmented structures were combined and overlaid with functional information of contrast medium-enhanced, dynamic MRI. After assigning colour attributes to the segmented structures, they were presented using a method for direct volume visualisation. RESULTS: Segmentation of organs and vessels as well as tissue differentiation yielded a morphological visualisation of anatomical structures that were overlaid with pharmacokinetic parameters derived from dynamic MRI, subsequently. Thereby, three-dimensional, arbitrary views on the functional data were displayed. CONCLUSIONS: Image analysis and visualisation of the acquired MR data establishes both a morphologic and functional evaluation of suspect lesions and adjacent organs. By integrating morphologic and functional MRI additional information can be gathered that possibly impinge on preoperative planning.

Data Interpretation, Statistical↗

Colour Doppler sonography in breast tumours: an update.

The aim of our study was to reassess the diagnostic performance of image-based, computer-assisted colour Doppler quantification under routine conditions. We used a computer-assisted protocol that quantitatively characterises a colour Doppler image by the relative amount of colour pixels (colour pixel density, CPD) and the colour hues (numerically expressed by the mean colour value, MCV) in 44 patients with breast carcinoma and 49 patients with benign breast lesions. Studies were carried out over two periods by two examiners, subsequently in charge of breast ultrasound. During the first period, the sensitivity of the MCV was 92 %, the specificity 75 %; the sensitivity of the CPD was 80 %, the specificity 81 %. During the second period, the sensitivity of the MCV was 58 %, the specificity 77 %; the sensitivity of the CPD was 68 %, the specificity 71 %. Despite measures to create uniform examination conditions, the diagnostic performance of this method may decline under routine conditions.

Adult↗

Spiral CT vs incremental CT: is spiral CT superior in imaging of the brain?

The aim of this study was to evaluate image quality of spiral CT of the brain as compared with incremental CT using identical scanning parameters. Incremental or spiral cranial CT was performed on 46 consecutive, randomized patients with non-traumatic disease of the brain on a Siemens (Erlangen, Germany) Somatom Plus 4. Evaluation was done in a randomized blinded way by two experienced radiologists. Different anatomical structures, image noise, and artifacts were scaled 1 (bad) to 4 (very good). Statistical analysis was done using the F-test of variance for partial sums of squares as well as Student's t-test. Incremental CT was superior to spiral CT for evaluation of the internal capsule, supratentorial artifacts, gray/white matter differentiation, and image noise. No statistically significant differences were seen for evaluation of the pons, infratentorial artifacts, and eye muscles. With identical scanning parameters incremental CT is superior to spiral CT in the assessment of small, complex structures in a low-contrast setting. No differences are seen for larger structures or small structures in a medium-contrast range. Artifacts localized close to the skull in spiral CT can easily mimic hemorrhage in traumatized patients. Spiral CT should therefore only be used for CT angiography and if 3D reconstructions are needed.

Artifacts↗