Search PubMed⌕ Search

Biomedical subjects

G Z Yang

Publications and source records attributed to G Z Yang.

At least 91 records · Page 5Linked to original sources

Assessment of regional left ventricular long-axis motion with MR velocity mapping in healthy subjects.

The pattern of left ventricular long-axis motion during early diastole was assessed with magnetic resonance (MR) velocity mapping in 31 healthy volunteers. Regional long-axis velocity varied with time and position around the ventricle. During systole, the base descended toward the apex. The greatest magnitude of long-axis velocity occurred during early diastole. The lateral wall had the highest velocity (140 mm/sec +/- 40 [mean +/- standard deviation]); the anterior and inferior walls had lower velocities (96 mm/sec +/- 27 and 92 mm/sec +/- 34, respectively). The inferoseptal area consistently had the lowest velocities (87 mm/sec +/- 40). Absolute values of peak early-diastolic velocity declined with age (r = -.64, P < .001). Peak early-diastolic velocity was not dependent on heart rate (r = .014, P = .94). Regional variations in left ventricular wall motion were seen. MR velocity mapping is a useful technique for assessing regional left ventricular long-axis heart function.

Adult↗

Mitral valve flow measured with cine MR velocity mapping in patients with ischemic heart disease: comparison with Doppler echocardiography.

Diastolic function is an important element of overall left ventricular function. The pattern of flow across the mitral valve is commonly used as a measure of diastolic ventricular function. Magnetic resonance (MR) velocity mapping of blood flow across the mitral valve was compared with Doppler echocardiography. Nineteen patients with known coronary artery disease (mean age, 62 years; 11 with previous myocardial infarction) were studied. The mean value of peak early filling velocity (+/- standard deviation) was 60.1 cm/sec +/- 14.3 with the MR method and 59.4 cm/sec +/- 13.7 with echocardiography (P = .732). The mean difference between the two measurements (95% confidence interval) was -0.8 cm/sec (-5.2 cm/sec, +2.2 cm/sec). The mean value of early deceleration was 4.3 m/sec2 +/- 1.5 with the MR method and 4.0 m/sec2 +/- 1.5 with echocardiography (P = .073). The mean difference was -0.4 cm/sec2 (-0.92 cm/sec2, +0.05 cm/sec2). The mean value of peak atriosystolic velocity was 51 cm/sec +/- 14.6 with the MR method and 62 cm/sec +/- 17.2 with echocardiography (P = .002). The mean difference was -11 cm/sec (-18.1 cm/sec, -3.45 cm/sec). Peak atrial filling was consistently lower with the MR method than with echocardiography. Time-averaged measurements of ventricular filling with MR velocity mapping are an accurate measure of early diastolic filling but underestimate the velocity of atriosystolic filling.

Adult↗

Measurement of regional aortic compliance by MR imaging: a study of reproducibility.

The reproducibility of MR imaging for the measurement of aortic compliance was studied in 47 healthy volunteers. Long and short term reproducibility and intraobserver variability were tested. The method was modified to improve image quality and short term reproducibility and intraobserver variability retested. For comparison, spin echo imaging was compared with cine gradient echo imaging. Initial long term reproducibility showed a mean difference (+/-SE) of 3% (+/- 7%) with 95% confidence interval (CI) for limits of agreement of +/- 69%. Short term reproducibility (7% +/- 6%, 95% CI +/- 46%) and intraobserver variability (1% +/- 2%, 95% CI +/- 31%) were better. After modification of the technique and optimization of image quality, both short term reproducibility and intraobserver variability improved (0% +/- 3%, 95% CI +/- 17% and 5% +/- 2%, 95% CI +/- 16% respectively). Aortic compliance can be measured using spin echo MR imaging with good reproducibility provided care is taken to obtain good quality images with high spatial resolution.

Adult↗

Dynamic range extension of cine velocity measurements using motion-registered spatiotemporal phase unwrapping.

A motion-registered spatiotemporal phase-unwrapping method for extending the dynamic range of cine magnetic resonance phase velocity measurements is presented. The interframe cardiac movement is estimated from the magnitude image derived from the velocity encoded raw data, which ensures that the phase signal is unwrapped in the temporal direction with reference to pixels belonging to the same anatomic flow region. An extra step of spatial phase correction is then used to further eliminate any residual errors. The combination of spatial and temporal information for phase unwrapping provides a robust way of extending the dynamic range of cine velocity data in the presence of large phase aliasing errors.

Algorithms↗

Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: the effects of age and coronary artery disease.

The objective was to investigate how the blood flows in the thoracic aorta, with special emphasis on flow reversal and flow into the coronary arteries. Three-directional MR velocity mapping was used to map multidirectional flow velocities in the aorta in 14 normal subjects and 14 patients with coronary artery disease. Dynamic flow vector maps and through-plane velocity maps were used. The flow reversed in all subjects in the upper ascending aorta and usually also in the distal aortic arch. Retrograde flow became antegrade again at various levels in the ascending aorta and in the coronary sinuses. Seven flow characteristics were investigated that, lumped together, were significantly different (P = .0005) in normal subjects compared with patients and in normal subjects 70 years of age and older compared with those younger than 70 years of age.

Adult↗

Hybrid ordered phase encoding (HOPE): an improved approach for respiratory artifact reduction.

Respiration causes continuous change in cardiac position, which leads to image degradation. Phase-encode reordering methods are often used to reduce these artifacts. An improved method for suppressing motion artifacts by reordering the acquisition of k space has been developed that is less sensitive to change of breathing patterns and bulk movement. We describe the theory behind the new approach and compare its results with those of existing methods by use of a phantom with simulated and actual acquired breathing patterns. The comparison was also made in vivo; cardiac scans were performed in 15 subjects with image planes that are known to be particularly susceptible to respiratory artifact. A significant improvement in image quality was achieved compared with conventional nonreordered and existing reordering methods.

Algorithms↗

Automatic enhancement, animation, and segmentation of flow in peripheral arteries from MR phase-shift velocity mapping.

The authors describe a technique for automatic enhancement, segmentation, and analysis of flow from MR phase shift velocity mapping. This method uses a specific flow related enhancement process to extract and localize the flow field within the image, followed by global flow analysis. By animation on low cost equipment (personal computers), this method can provide various ways of visualizing flow in vivo and its variation in different structures and lesions. Our preliminary results using this method for analyzing flow data in the aortic bifurcation of healthy volunteers are encouraging.

Aorta, Abdominal↗

Visualization of flow by vector analysis of multidirectional cine MR velocity mapping.

OBJECTIVE: We describe a noninvasive method for visualization of flow and demonstrate its application in a flow phantom and in the great vessels of healthy volunteers and patients with aortic and pulmonary arterial disease. The technique uses multidirectional MR velocity mapping acquired in selected planes. Maps of orthogonal velocity components were then processed into a graphic form immediately recognizable as flow. MATERIALS AND METHODS: Cine MR velocity maps of orthogonal velocity components in selected planes were acquired in a flow phantom, 10 healthy volunteers, and 13 patients with dilated great vessels. Velocities were presented by multiple computer-generated streaks whose orientation, length, and movement corresponded to velocity vectors in the chosen plane. RESULTS: The velocity vector maps allowed visualization of complex patterns of primary and secondary flow in the thoracic aorta and pulmonary arteries. The technique revealed coherent, helical forward blood movements in the normal thoracic aorta during midsystole and a reverse flow during early diastole. Abnormal flow patterns with secondary vortices were seen in patients with dilated arteries. CONCLUSION: The potential of MR velocity vector mapping for in vitro and in vivo visualization of flow patterns is demonstrated. Although this study was limited to two-directional flow in a single anatomical plane, the method provides information that might advance our understanding of the human vascular system in health and disease. Further developments to reduce the acquisition time and the handling and presenting of three-directional velocity data are required to enhance the capability of this method.

Adolescent↗

Vortical flow feature recognition: a topological study of in vivo flow patterns using MR velocity mapping.

PURPOSE: To describe an automatic method for studying vortical flow features using multidirectional magnetic resonance velocity imaging. METHODS: The technique relied on the use of linear differential equations to provide local approximation to the acquired MR velocity data and to identify vortical flow patterns that were characterised by their circular or swirling motion. Two directional MR velocity images were acquired on a 0.5 T system with a TE of 14 ms, slice thickness of 10 mm, and field of view of 30-40 cm. RESULTS: The method was validated using numerical simulation, and the potential of this technique for studying blood flow features was demonstrated in the ascending aorta of a healthy volunteer and that of a patient with Marfan's syndrome. The difference in vortex flow dynamics of the left ventricle between a normal subject and a patient with dilated ventricle was also compared. CONCLUSION: The approach of detecting critical flow features prior to analysing dynamical indices of the fluid is suited to the topological study of complex flow patterns depicted by MR velocity mapping techniques.

Algorithms↗

A comparison of methods for enhancing the detection of areas of decreased attenuation on CT caused by airways disease.

PURPOSE: The purpose of this work was to investigate thin section CT image enhancement of subtle areas of decreased attenuation of the lung parenchyma in suspected airways disease. METHOD: Forty-seven consecutive patients with chronic sputum production underwent pulmonary function tests and high resolution CT (HRCT). Single section inspiratory (INSP), expiratory (EXP), and minimum intensity projection (MINIP) images through the lower lobes were acquired. A histogram stretch was applied to the INSP and MINIP images, generating two further image formats. The five image types were compared for the extent of decreased attenuation, observer confidence, and correlations with pulmonary function tests. RESULTS: Interobserver variation was lowest with MINIP images (mean weighted K: MINIP 0.70, INSP sections 0.65, other image formats < or =0.48). Observers were most confident with EXP and MINIP images. EXP sections identified more disease than MINIP images (p<0.001). Correlations with pulmonary function tests were similar for each image format. CONCLUSION: The HRCT changes of small airways disease are enhanced with image postprocessing. MINIP images are associated with increased observer confidence and agreement as compared with HRCT alone.

Adult↗

Gradient correction and classification of CT lung images for the automated quantification of mosaic attenuation pattern.

PURPOSE: The detection of density differences, or "mosaic attenuation pattern," on CT images may be difficult when the regional inhomogeneity of the density of the lung parenchyma is subtle. The purpose of this work was to develop a fully automated method for the reproducible quantification of the underattenuated areas of the lung parenchyma. This technique may be useful in increasing the precision of investigation of structure/function relationships. METHOD: Anatomical segmentation was achieved by a structure-filtering operator based on mathematical morphology. To compensate for the density gradient visible on lung CT scans, a model-based iterative deconvolution filter and an adaptive clustering algorithm were developed. Validation was performed with CT images from a lung phantom, 15 patients with constrictive obliterative bronchiolitis, and 8 normal subjects. RESULTS: The accuracy of the estimate of the density gradient on phantom studies was 93.3%. The automated quantification of the areas of decreased attenuation on scans of constrictive obliterative bronchiolitis was within 8.2% from the average scoring of two experienced observers. CONCLUSION: The proposed technique is fully automated and can accurately correct for density gradient and classify areas of decreased attenuation on lung CT images.

Bronchiolitis Obliterans↗