Search PubMed⌕ Search

Biomedical subjects

G Weisser

Publications and source records attributed to G Weisser.

At least 19 recordsLinked to original sources

Teleradiology applications with DICOM-e-mail.

For the connection of several partners to a Dicom-e-mail based teleradiology network concepts were developed to allow the integration of different teleradiology applications. The organisational and technical needs for such an integration were analysed. More than 60 institutions including 23 hospitals in the Rhein-Neckar-Region, Germany were connected. The needed functionality was grouped in six teleradiology applications (emergency consultation, tele-guided examinations, expert consultations, cooperative work, scientific cooperations and homework with on call services) and their technical and organisational needs according to availability, speed of transfer, workflow definitions and data security needs was analysed. For the local integration of teleradiology services the setup and workflow is presented for a standalone teleradiology workstation and a server based teleradiology gateway. The line type needed for different groups of applications and users is defined. The security concept and fallback strategies are laid out, potential security problems and sources of errors are discussed. The specialties for the emergency teleradiology application are presented. The DICOM-e-mail protocol is a flexible and powerful protocol that can be used for a variety of teleradiology applications. It can meet the conditions for emergency applications but is limited if synchronous applications like teleconferences are needed.

Computer Security↗

Standardization of teleradiology using Dicom e-mail: recommendations of the German Radiology Society.

Until recently there has been no standard for an interoperable and manufacturer-independent protocol for secure teleradiology connections. This was one of the main reasons for the limited use of teleradiology in Germany. Various teleradiology solutions have been developed in the past, but the vast majority have not been interoperable. Therefore an ad hoc teleradiology connection was impossible even between partners who were already equipped with teleradiology workstations. Based on the evaluation of vendor-independent protocols in recent years the IT Working Group (AGIT) of the German Radiology Society set up an initiative to standardize basic teleradiology. An e-mail based solution using the Dicom standard for e-mail attachments with additional encryption according to the OpenPGP standard was found to be the common denominator. This protocol is easy to implement and safe for personalized patient data and fulfills the legal requirements for teleradiology in Germany and other countries. The first version of the recommendation was presented at the 85th German Radiology Convention in 2004. Eight commercial and three open-source implementations of the protocol are currently available; the protocol is in daily use in over 50 hospitals and institutions.

Computer Communication Networks↗

[Teleradiology with DICOM e-mail: recommendations of @GIT].

E-mail is ideal for ad-hoc connections in teleradiology. The DICOM standard offers the possibility to append DICOM data types as a MIME attachment to any e-mail, thus ensuring the transmission of the original DICOM data. Nevertheless, there are additional requirements (e.g. protection of data privacy) which must be obeyed. Because of the lack of given standards which would grant interoperability as well as manufacturer independence, teleradiology has not been established in Germany until today. Therefore, the IT-Team (Arbeitsgemeinschaft fur Informationstechnologie, @GIT) of the Radiological Society of Germany (Deutsche Rontgengesellschaft, DRG) set up an initiative to standardise telemedicine by using e-mail. Its members agreed that an e-mail-based variant would be the most practicable way to a communication solution -- as easy to implement as to use. In their opinion, e-mail represents the smallest common denominator for a safe data interchange that would fulfill the legal advantages for telemedicine in Germany.

Computer Communication Networks↗

[Value of electron beam tomography (EBT)].

Electron beam tomography (EBT) has been scientifically evaluated to a much lesser degree for non-cardiac indications than for cardiac purposes. Therefore, four groups of investigators in Berlin (2), Mannheim and Munchen, which were supported by the Deutsche Forschungsgemeinschaft (DFG), included applications outside the heart in their evaluation of EBT technology. EBT has proven useful to look for pulmonary embolism and to assess other vessels (aorta, aortic branches, and intracranial arteries). Imaging of the lung parenchyma benefits from its intrinsic high contrast and from the fast data acquisition of EBT. Limited photon efficiency, higher radiation exposure, increased noise levels and other artifacts, however, markedly reduce the value of EBT for imaging of low contrast objects compared to conventional spiral CT and multislice CT (MSCT), compromising, in particular, the morphologic depiction of parenchymal abdominal organs and the brain. Consequently, scientific studies to further evaluate EBT for scanning of the brain and parenchymal abdominal organs were not pursued. Radiation exposure for non-cardiac EBT studies is up to three times higher than that for respective spiral CT studies, and in children EBT can only be advocated in select cases. Radiation exposure for the various prospectively triggered cardiac examination protocols of EBT is lower than that for conventional coronary angiography. Radiation exposure in cardiac multislice CT exceeds severalfold that of EBT, but the dose efficiency of EBT and MSCT are similar due to higher spatial resolution and less image noise of MSCT. In addition, modifications of MSCT (ECG pulsing) can further reduce radiation exposure to the level of EBT. Technical improvements of the EBT successor scanner "e-Speed" enable faster data acquisition at higher spatial resolution. Within comparative studies, the "e-Speed" will have to prove its value and competitiveness, particularly in comparison with multislice CT. After profound scientific assessment in a multicenter evaluation supported by the Deutsche Forschungsgemeinschaft (DFG) and regardless of the specific suitability of electron beam tomography for various cardiac and some non-cardiac indications, the investigators unanimously find the electron beam tomograph Evolution C150 XP not suitable as a whole body CT scanner.

Age Factors↗

[Diagnostic value of electron-beam computed tomography (EBT). I. Cardiac applications].

Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages, not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart.

Adult↗

Effects of end-inspiratory and end-expiratory pressures on alveolar recruitment and derecruitment in saline-washout-induced lung injury -- a computed tomography study.

BACKGROUND: Lung protective ventilation using low end-inspiratory pressures and tidal volumes (VT) has been shown to impair alveolar recruitment and to promote derecruitment in acute lung injury. The aim of the present study was to compare the effects of two different end-inspiratory pressure levels on alveolar recruitment, alveolar derecruitment and potential overdistention at incremental levels of positive end-expiratory pressure. METHODS: Sixteen adult sheep were randomized to be ventilated with a peak inspiratory pressure of either 35 cm H2O (P35, low VT) or 45 cm H2O (P45, high VT) after saline washout-induced lung injury. Positive end-expiratory pressure (PEEP) was increased in a stepwise manner from zero (ZEEP) to 7, 14 and 21 cm of H2O in hourly intervals. Tidal volume, initially set to 12 ml kg(-1), was reduced according to the pressure limits. Computed tomographic scans during end-expiratory and end-inspiratory hold were performed along with hemodynamic and respiratory measurements at each level of PEEP. RESULTS: Tidal volumes for the two groups (P35/P45) were: 7.7 +/- 0.9/11.2 +/- 1.3 ml kg(-1) (ZEEP), 7.9 +/- 2.1/11.3 +/- 1.3 ml kg(-1) (PEEP 7 cm H2O), 8.3 +/- 2.5/11.6 +/- 1.4 ml kg(-1) (PEEP 14 cm H2O) and 6.5 +/- 1.7/11.0 +/- 1.6 ml kg(-1) (PEEP 21 cm H2O); P < 0.001 for differences between the two groups. Absolute nonaerated lung volumes during end-expiration and end-inspiration showed no difference between the two groups for given levels of PEEP, while tidal-induced changes in nonaerated lung volume (termed cyclic alveolar instability, CAI) were larger in the P45 group at low levels of PEEP. The decrease in nonaerated lung volume was significant for PEEP 14 and 21 cm H2O in both groups compared with ZEEP (P < 0.005). Over-inflated lung volumes, although small, were significantly higher in the P45 group. Significant respiratory acidosis was noted in the P35 group despite increases in the respiratory rate. CONCLUSION: Limiting peak inspiratory pressure and VT does not impair alveolar recruitment or promote derecruitment when using sufficient levels of PEEP.

Animals↗

[Quality assurance with teleradiology].

Teleradiology offers many applications for quality assurance in medicine. The spectrum reaches from electronic consultations in emergency or special cases and double reading--along with new models of cooperative work and medical networks--to technical quality assurance and integration into interinstitutional and patient controlled health records. Regional teleradiology networks based on server concepts can fulfill the developing technical and organisational requirements. The increasing mobility arising from smaller radiological equipment and improved accessibility to experts with minimized visualisation and reporting systems will change the radiological world of tomorrow, especially in combination with the usage of knowledge based systems in reference data bases and computer assisted diagnosis (CAD). Teleradiology by itself must be liable to quality assurance measurements to prevent unnecessary radiation exposure or danger to the doctor patient relation.

Computer Communication Networks↗

[The future of teleradiology: results of Teleradiology Expert Meeting of the Health Network Congress 2001].

Legal prerequisites have substantial influence on the development of teleradiology. At an expert meeting (Mannheim, 8.6.2001) a proposal for a teleradiology article in the new German x-ray ordinance has been set up. An exception of the demand for a doctor trained in radiation protection at the point of examination shall be established for emergency cases. To realize the intended improvement of patient care measurements for quality assurance concerning the medical personnel and processes are necessary. Along with other current developments the basis of secure regional teleradiology networks is now built up.

Forecasting↗

[New concepts in teleradiology with Dicom e-mail].

UNLABELLED: The recently published Dicom supplement 54 (dicom e-mail) defines a connection between the internet and the medical communication inside hospitals. Up to now vendor specific dicom protocol additions were needed to realize certain teleradiology solutions. The new concept relies on vendor independent standard protocols without specific additions. MAIN FEATURES: client-server solution using the internet designed for emergency medicine integration of various clinical informations approved security concept modularized architecture The concept was realized within the scope of a teleradiology project of the state of Rheinland-Pfalz, Germany. It will be expanded to the state of Baden-Wuerttemberg. Germany in 2002 with over 20 hospitals included.

Computer Systems↗

Teleradiology requirements and aims in Germany and Europe: status at the beginning of 2000.

Specific radiological requirements have to be considered for realization of telemedicine. In this article the goals and requirements for an extensive implementation of teleradiology are defined from the radiological user's point of view. Necessary medical, legal and professional prerequisites for teleradiology are presented. Superior requirements, such as data security and privacy or standardization of communication, must be realized. Application specific requirements, e. g. quality and extent of teleradiological functions as well as technological alternatives, are discussed. Each project must be carefully planned in relation to one's own needs, extent of functions and system selection. Topics like legal acceptance of electronic documentation, reimbursement of teleradiology and liability must be clarified in the future.

Europe↗

First results of computerised tomographic angiography using electron beam tomography.

The aim of this study was to evaluate the suitability of electron beam tomography (EBT) with fast continuous volume scanning for CT angiography (CTA) in chest and abdomen. An Evolution XP EBT scanner with a new software version (12.34) was used. One hundred forty images per study can be acquired in 17 s using 3-mm collimation and overlapping image reconstruction. Study protocols for five different clinical applications of EBT CTA were established and evaluated. The EBT CTA technique was performed in 155 patients. High- and homogeneous density values were achieved along the whole course of the vessels; the mean density in the aorta was > 240 HU. Coeliac axis, superior and inferior mesenteric artery, renal and lumbar arteries were visualised in all cases. Maximum intensity projection and shaded surface display reconstruction demonstrated the relation between aneurysm and aortic branches very well due to an excellent resolution along the z-axis. In large scan volumes overlapping image reconstruction demonstrated better resolution along the z-axis than is available with helical CT. The EBT CTA technique proved to be very well suited excellent suitability for evaluation of pulmonary vessels. Compared with helical CT, EBT CTA offers a shorter scan time, which allows higher contrast enhancement in pulmonary vessels. The identification of intraluminal emboli and mural thrombi has improved. The EBT CTA technique is a very reliable tool for evaluation of aortic disease and pulmonary vessels.

Angiography↗

[The role of electron beam CT in the diagnosis of acute pulmonary embolism--presenting a new examination protocol].

PURPOSE: To evaluate electron beam tomography in the detection of acute pulmonary embolism using a new acquisition protocol. MATERIALS AND METHODS: 65 patients underwent electron beam tomography (EBT) and v./p. scintigraphy. According to the inclusion criteria 46 patients participated in the study. Contrast enhancement and detectability of pulmonary arteries were scored on a 4 step scale for image quality. The results of prospective detection of pulmonary embolism were compared for both modalities (blinded reading). "Embolism", "questionable embolism" and "no embolism" were used as categories. RESULTS: 22/46 patients (48%) showed acute pulmonary embolism. EBT and scintigraphy were discordant in 24% of patients. In EBT 1 false positive and 1 false negative case occurred, scintigraphy demonstrated 2 false negative and 3 false positive cases. 6/9 patients with questionable findings in scintigraphy were correctly classified by EBT to a category "embolism" or "no embolism" as "suspected embolism", EBT displayed a sensitivity of 96.3% and a specificity of 94.7%. Scintigraphy evidenced a sensitivity of 93.7% and a specificity of 84.4%. CONCLUSIONS: EBT shows better results than scintigraphy for the detection of acute pulmonary emboli. The evaluated new acquisition protocol for EBT seems to be well suited. High vessel contrast and thin slices allow a reliable detection of segmental and subsegmental pulmonary arteries.

Acute Disease↗

Dose and image quality of electron-beam CT compared with spiral CT.

RATIONALE AND OBJECTIVES: To examine dose and image quality of electron-beam CT (EBCT) with continuous volume scan versus spiral CT. METHODS: An EBCT scanner was compared with a spiral CT (SCT) scanner. Three phantoms were used to measure low-contrast resolution, high-contrast resolution, slice width, and dose. RESULTS: The EBCT scans showed 30% lower high-contrast resolution for most settings. The dose was comparable to that of spiral CT with 3 mm collimation and 76%/106% higher with EBCT for 1.5 mm/6 mm collimation. Low-contrast resolution was comparable to that of spiral CT using 3 mm collimation, slightly worse for 1.5 mm, and bad for 6 mm EBCT collimation (four times higher dose to reach comparable contrast-to-noise ratio). CONCLUSIONS: Significant restrictions were found using EBCT with continuous volume scan. The authors found that 3 mm collimation can yield acceptable high-contrast resolution and good low-contrast resolution compared with spiral CT. The use of 6 mm or 1.5 mm collimation needs to be restricted to selected cases.

Evaluation Studies as Topic↗

[Performance of electron-beam CT: continuous-volume-scan compared to spiral CT].

To compare patient dose and image quality of electron-beam-CT vs. spiral-CT by means of phantom measurements. An EBCT scanner (C-150 XP) and a spiral-CT scanner (GE HiSpeed Advantage) were used to scan three different phantoms. Administered dose, high contrast (HC) resolution, low contrast (LC) lesion detectability and the width of the radiation beams were measured. EBCT showed 25-35% lower HC resolution in comparison to spiral-CT. LC lesion detectability showed equivalent results for S/N vs. patient dose using 3 mm collimation with EBCT and spiral-CT, whereas spiral-CT was superior for 1.5 and 6 mm collimation. Dose measurements revealed a 2 fold higher patient dose using EBCT with 1.5 mm or 6 mm collimation compared to spiral-CT using equivalent scan parameters. No differences were seen using 3 mm collimation. Differences were due to insufficient beamside collimation of the EBCT. The use of EBCT with 6 mm collimation should be avoided, because of impaired performance. Using 3 mm collimation, EBCT showed comparable performance like state of the art spiral-CT despite lower HC resolution.

Algorithms↗

[Electron-beam CT-angiography in abdominal aortic aneurysms. Initial results].

PURPOSE: To evaluate the suitability of ultrafast electron-beam tomography (EBT) for the investigation of abdominal aortic aneurysms using CTA. METHODS: Thirty-one patients with suspected abdominal aortic aneurysm were investigated with EBT using an Evolution XP scanner (Siemens, Erlangen) with the newest software version 12.34 with continuous volume scanning of 140 images in 17 s. Collimation was 3 mm, table increment 4 mm with overlapping image reconstruction every 2 mm, exposure time 200 ms (124 mAs), resulting in a scan-range of 28 cm. A quantity of 80 ml contrast material was administered (flow 4 ml/s). Visualization of the abdominal aorta and its branches was performed with MIPs and shaded surface display. Evaluation of image quality was based on a four-step classification scale (1 = good, 4 = insufficient) for the demonstration of the abdominal aorta and the visceral, renal and iliac arteries. RESULTS: All EBT examinations demonstrated high and homogeneous density values along the whole vessel course with a mean density value of 258.7 +/- 47.3 HU for the abdominal aorta and the iliac arteries. Quality evaluation for the vessel demonstration showed mean values between 1.22 and 1.57 for the abdominal aorta and the visceral, renal and iliac arteries. CONCLUSIONS: EBT with 140 slices and slice reconstruction every 2 mm offers a high z-axis resolution resulting in high-quality CT angiographies of the whole abdominal aorta and its branches.

Aged↗

[Clinical use of a new analytical method for the determination of bone density by means of quantitative computer tomography].

AIM: Evaluation of the clinical suitability of a new analytical method for the determination of bone mineral density (BMD) by means of SEQCT as well as a comparison with the established method. METHODS: In order to verify the stability of both systems, phantom measurements were performed on a lumbal spine torso as well as on 78 patients. 44 patients were examined by means of the established method and 34 according to the new method. Parallel measurements were possible in 15 patients. RESULTS: The phantom measurements proved a high stability of both methods. Regarding the absolute BMD the new method resulted in higher BMD values. This result was confirmed by parallel measurements in 15 patients. The new method demonstrated increased suitability due to less time consuming preparations. Dose reduced scan parameters could not be achieved in all patients, so that the time saving effect could not be considered. In these cases manual settings were required. CONCLUSION: A substitution of the established method for BMD measurement by means of SEQCT with the new method seems to be possible. However, the results will have to be corrected by the percentage of deviation from the default value of the quality phantom.

Absorptiometry, Photon↗

Quantification of color Doppler for the evaluation of tissue vascularization.

Assessment of tissue vascularization with color Doppler (CD) can improve differential diagnosis of tumors. Until now, measurement of flow velocities is restricted to conventional duplex ultrasound of single vessels or semiquantitative scoring of the vessel distribution in CD. We developed a new method for quantification of CD data in organs or tumors by statistical image analysis. Based on standardized image recording, data is acquired from the video output of any ultrasound scanner using a 24-bit color framegrabber in a personal computer. The digitized colors are recognized according to their position in the CD palette bar resulting in an 8-bit color image (number of identified pixels > 99.9%). Within the region of interest, statistics of the detected flow patterns are calculated. The color pixel density and the mean color value varies between recordings of the same image during subsequent systolic peaks with a SD of 10% and 2%, respectively, and within different sections of the same organ or tumor with 25% and 10-50%. This analysis can be used for comparative or longitudinal studies and an objective evaluation of CD in complex vascular formations such as tumors. Its diagnostic impact has already been demonstrated in clinical studies.

Blood Flow Velocity↗

3D MPRAGE evaluation of lesions in the posterior cranial fossa.

Standard spin-echo images of the posterior cranial fossa are usually impaired by pulsation artifacts. We evaluated a heavily T1 weighted MPRAGE sequence (TR/TE/alpha/TI = 10/4/10-15 degrees/200-350) for detection of intracerebral lesions in the posterior fossa in 11 patients. Overall quality of the MPRAGE images was superior due to the lack of pulsation artifacts, high S/N and excellent gray-white matter contrast. Lesion detection was better in one patient, equal in six and inferior in four patients compared to SE technique. A cerebellar metastasis (8 mm) in one patient was completely blurred from pulsation artifacts on the SE images. Whereas multiple small lesions (< or = 4 mm) with discrete contrast enhancement were missed on the MPRAGE images in three patients. We conclude, that the MPRAGE sequence yields high quality images with isotropic spatial resolution in a reasonable time. But MPRAGE with these parameters can not replace standard SE images in screening the posterior fossa, because of a decreased sensitivity in the detection of small contrast-enhancing lesions.

Adolescent↗