Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer.

The goal of this study was to identify the parameters that must be controlled during in vivo resonance frequency measurements with a custom Osstell transducer for custom implants in the guinea pig animal model. A numerical study and in vitro measurements were performed to determine the influence of the boundary conditions as well as the transducer orientation on the resonance frequency measured by the custom Osstell transducer. In the reported guinea pig model, the type of boundary condition, the orientation of the transducer (parallel or perpendicular to the long axis of the bone) and the length of the modelled bone have a large influence on the resonance frequency values. This implies that a follow-up in time of the stability of an implant requires the boundary conditions applied to the bone in which the implant is installed as well as the orientation of the transducer to be highly repeatable. Applying controlled boundary conditions during in vivo measurements had a highly positive influence on the repeatability of the Osstell measurements. This improves the possibility of the technique to measure changes in the implant-bone interface during healing of the implant.

Animals↗

The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approach.

The purpose of this study was to evaluate the modal behaviour of the bone-implant-transducer (Osstell) system by means of finite element analyses. The influence of different parameters was determined: (1) the type of implant anchorage being trabecular, cortical, uni-cortical, or bi-cortical, (2) the implant diameter, (3) the length of the implant embedded in the bone, and (4) the bone stiffness. The type of anchorage determines the resulting modal behaviour of the implant-transducer system. A rigid body behaviour was found for a uni-cortical anchoring and for a homogeneous anchoring with low bone stiffness (< or =1000 MPa), whereas a bending behaviour was found for a homogeneous anchoring with a high bone stiffness (> or =5000 MPa) and for a bi-cortical anchorage. The implant dimensions influence the values for the resonance frequencies. Generally, an increase in implant diameter or implant length (in bone) results in higher resonance frequencies. This study also showed that resonance frequencies in case of rigid body behaviour of the implant-transducer system are more sensitive to changes in bone stiffness than resonance frequencies in case of bending behaviour. In conclusion, it seems that the Osstell transducer is suited for the follow-up in time of the stability of an implant, but not for the quantitative comparison of the stability of implants.

Anisotropy↗

A 3D active shape model for the evaluation of the alignment of the spine during sleeping.

This paper explains how the shape of the spine can be evaluated from back surface measurements in a recumbent position, by using point distribution models (PDM) and typical shape variability of the spine in a lateral sleeping position. CT-scans of 12 volunteers were taken in this posture on a firm and a soft sleeping system to provide a training set for the PDM. Active shape models (ASM) were used to enhance the accuracy of the spinal reconstruction from measurements by limiting the shape of the spine to characteristic shapes from a biomechanical and/or clinical point of view. A comparison was made between calculated shapes, obtained from surface measurements, and those measured vertebral body centres (from CT-scans). An RMS accuracy of 2.6mm was obtained in 3D, and 1.8mm in frontal view, which was sufficient to compare spinal deformations of a subject on different sleeping systems.

Adult↗

A three-dimensional active shape model for the detection of anatomical landmarks on the back surface.

In this study relations between anatomical landmarks on the dorsal surface of the human torso corresponding to underlying skeletal structures are established. By examining the statistics of the positions of the landmarks in a training set of subjects a point distribution model is derived. Rotations of the pelvis are simulated in order to show that the main mode shapes of variation are consistent with rotations of the pelvis relative to the trunk. The parameters of these mode shapes can therefore be used as independent measures of clinical parameters such as pelvic inclination, pelvic tilt, etc. The point distribution model is further applied to improve reliability and robustness for an automatic and objective detection of the anatomical landmarks on the back surface (active shape model). The results show that it is possible to replace radiographs by surface measurements in order to measure position and orientation of the pelvis, which is particularly valuable in the case of functional examinations that normally involve a large number of radiographs (e.g. to measure the position of the pelvis in a scoliosis).

Adolescent↗

A semi-active milling procedure in view of preparing implantation beds in robot-assisted orthopaedic surgery.

Bone cutting in total joint reconstructions requires a high accuracy to obtain a well-functioning and long-lasting prosthesis. Hence robot assistance can be useful to increase the precision of the surgical actions. A drawback of current robot systems is that they autonomously machine the bone, in that way ignoring the surgeon's experience and introducing a safety risk. This paper presents a semi-active milling procedure to overcome that drawback. In this procedure the surgeon controls robot motion by exerting forces on a force-controlled lever that is attached to the robot end effector. Meanwhile the robot constrains tool motion to the planned motion and generates a tool feed determined by the feed force that the surgeon executes. As a case study the presented milling procedure has been implemented on a laboratory set-up for robot-assisted preparation of the acetabulum in total hip arthroplasty. Two machining methods have been considered. In the first method the surgeon determines both milling trajectory and feed by the forces that he/she executes on the force-controlled lever. In the second method the cavity is machined contour by contour, and the surgeon only provides the feed. Machining experiments have shown that the first method results in large surface irregularities and is not useful. The second method, however, results in accurate cavity preparation and has therefore potential to be implemented in future robot systems.

Acetabulum↗

Three-dimensional mathematical reconstruction of the spinal shape, based on active contours.

To reduce the amount of radiographs needed for patients with a scoliosis, a radiation-free method based on topographic images of the back was developed. An active contour model simulating spinal stiffness has been applied to video rasterstereographic (VRS) data. The aim of the present study is (a) to evaluate the applicability of active contours to improve the accuracy and the reliability of the three-dimensional (3D) spinal midline reconstruction from back surface data and (b) to design a more robust method to detect the spinal midline. To evaluate the reliability and accuracy, the active contour-based method is compared to a conventional procedure, which has been specifically developed for scoliosis; both methods produce a 3D curve of the spinal midline. The frontal projections and surface rotations of these spinal midlines are compared; r.m.s. deviations of 0.9 mm between the frontal curves and 0.4 degrees between the surface rotations were obtained. Applying the active contour-based method does therefore not result in a substantial difference in accuracy to the conventional procedure. As a conclusion the active contour method is a valuable mathematical method that can accurately reconstruct the spinal midline based on back surface data. In addition, the method can be applied to various postures.

Algorithms↗

On the assets of CAD planning for craniosynostosis surgery.

SkullWiz is a computer-aided design program that transforms computer tomographic data of the neurocranium into a mathematical model that can be interactively manipulated to plan craniosynostosis surgery. Proper planning of this type of surgery involves reference to the underlying viscerocranium and to normal neurocranial dimensions, simulation of all basic surgical actions (closed and open osteotomy, translation, rotation, bending, removal, burring), and reference to the mechanical properties of calvarial bone at a given age. With SkullWiz, infinite trials are possible to develop a surgical plan that combines minimal action with maximum morphologic result. In contrast, physical models, e.g., foam milled or stereolitographic, provide just a single (or double, after gluing) opportunity to visualize three-dimensional morphology and simulate a treatment plan, without reference support. Validation of SkullWiz is difficult due to parameter variability. Its assets are therefore graphically exemplified in two common types of nonsyndromatic single-suture craniosynostosis-trigonocephaly and anterior plagiocephaly. SkullWiz is one of the most accurate planning tools currently available for craniosynostosis surgery. Accurate transfer of the planning by aluminium templates results in efficient and precise surgery by avoiding per-operative "chipping and fitting."

Age Factors↗

Structural and radiological parameters for the nondestructive characterization of trabecular bone.

Trabecular bone is characterized by compositional and organizational factors. The former include porosity at microlevel and mineralization. The latter refer to the trabecular architecture. Both determine the mechanical properties of the trabecular bone. The aim of this study is to investigate the relationship between the mechanical properties and the local HU value, the bone mineral density, the in vitro histomorphometric properties assessed by means of microcomputed tomography, and the Young's modulus determined by ultrasound measurement. Also the correlation between local HU values based on CT data of the full bone and HU values based on CT data of excised trabecular bone cylinders is investigated. Therefore density and strength related parameters of 22 trabecular bone cylinders retrieved from a fresh cadaver femur were measured by using different techniques. The mean HU value of the excised bone samples is very highly correlated with the pQCT density (R2=0.95) and the microCT-based morphometric parameter BV/TV (R2=0.95). The mean HU values, determined from the CT images of the planned and excised bone samples, are less highly correlated (R2=0.75). The Young's modulus E(US) determined from the ultrasound measurement is highly correlated with the maximal stress sigmamax (R2 = 0.88) but not with the mechanically determined Young's modulus Emech (R2 = 0.67). The maximal stress sigmamax correlates well with the density parameters (R2 varies between 0.76 and 0.86). On the contrary the mechanically determined Young's modulus Emech does not correlate well with the density parameters (R2 varies between 0.52 and 0.56). The absorbed energy Eabs during the deformation is only highly correlated with the maximal stress sigmamax (R2 = 0.83). The inclusion of structural parameters besides a density related parameter did improve the prediction of the Young's modulus and the maximal stress. In conclusion, it seems that the HU value from clinical CT scanning is a good predictor of the local bone density and volume fraction. A combination of local density and a measure of the structural anisotropy is clearly needed to achieve good predictions of bone mechanics.

Bone and Bones↗

Use of microfocus computerized tomography as a new technique for characterizing bone tissue around oral implants.

Qualitative and quantitative analysis of peri-implant tissues around retrieved oral implants is typically done by means of light microscopy on thin histological sections containing the metal surface and the undecalcified bone. It remains, however, a labor-intensive and thus time-consuming job. Moreover, it is a destructive technique that allows tissue quantification in only a limited number of two-dimensional sections. As an alternative, we evaluated the bone structure around screw-shaped titanium implants by means of microfocus computerized tomography (micro-CT) because it presents a number of advantages compared to conventional sectioning techniques: micro-CT is nondestructive, fast, and allows a fully three-dimensional characterization of the bone structure around the implant. Images can be reconstructed in an arbitrary plane, and three-dimensional reconstructions are also possible. Because of its high resolution, individual trabeculae can be visualized. The accuracy of micro-CT was qualitatively evaluated by comparing histological sections with the corresponding CT slices for the same specimen. The overall trabecular structure is very similar according to both techniques. Even very close to the interface, the titanium implant does not seem to produce significant artifacts. Furthermore, because the complete digital data on the trabecular bone structure around the implant is available, it is possible to create finite-element models of the bone-implant system that model the trabeculae in detail so that mechanical stress transfer at the interface can be studied at the level of individual trabeculae. Therefore, micro-CT seems to be very promising for the in vitro assessment of the three-dimensional bone structure around oral implants. Further research will be needed to evaluate its accuracy in a more quantitative way.

Animals↗

Computer-aided craniofacial surgical planning implemented in CAD software.

Accurate presurgical planning is imperative for successful cranial surgery. This article introduces a simulation program developed in a computer-aided design environment. The neurocranium is introduced as a mathematical surface, since this is the part on which the actual operation will be performed. The viscerocranium, which serves as reference, is visualized using small triangular surfaces. The development of the program commenced with a classification of the different surgical techniques mentioned in the literature into six basic actions. The use of mathematically described surfaces has the advantage that the program can simulate actions which change the shape of a surface and perform an on-line estimation of the fracture risk during bending. Three-point bending tests were carried out to provide the necessary data to perform the mathematical check, as these data are not available in the literature. A database with reference distances was introduced to guide the surgeon to obtain the best possible results. During one clinical trial, the computer was taken into the operating room so that the surgical plan developed with the simulation program could be applied to the actual operation.

Brain↗

Lipoatrophia semicircularis and the relation with office work.

The relation between lipoatrophia semicircularis (LS--band-like circular depressions and isolated atrophy of the subcutaneous fatty tissue on the anterior thighs and sitting posture or pressure on the seat surface of office chairs was investigated in an office environment. A questionnaire was presented to 21 subjects and electromyographic measurements, video analysis and pressure measurements were performed. Remarkable posture differences between the LS group and the group without LS were found: less use of the lumbar support of the chair, static sitting postures and a too high seat surface of the office chair were characteristics of the subjects with LS. These observations were confirmed by higher pressure measurements for the subjects with LS. In addition, highly significant pressure differences were found between different chairs.

Adipose Tissue↗

Machining and accuracy studies for a tibial knee implant using a force-controlled robot.

Total knee arthroplasty requires accurate preparation of the bone surfaces to maximize bone implant contact area in cementless surgery and to obtain proper joint kinematics and ligament balancing. Robots can make the cuts with the necessary high precision. The purpose of this article is threefold: to propose an alternative method for intraoperative registration using an intramedullary rod and an alternative method for force control using the hybrid force-velocity control scheme; to demonstrate that the accuracy and the surface flatness of the cuts machined by a robot are better than in a conventional operation; and to monitor the machining process and to try to derive some information about the local bone quality from it. The results of the laboratory study are promising: the surface flatness of the tibial plateau, calculated using a least squares method, is 0.1-0.2 mm, which is significantly better than in conventional surgery; and the high angular accuracy of the robot allows the bone cuts to be located precisely. Further, an exponential relation between milling forces and local bone density was established, so measurements of the milling forces can provide the surgeon with on-line information about the local bone quality.

Animals↗

Materials selection and design for orthopaedic implants with improved long-term performance.

Design and materials selection are equally important in the development of orthopaedic implants. Two case studies are presented to illustrate this: the development of a femoral component of a total hip prosthesis and the study of alternative designs of a tibial component of a total knee prosthesis. Bioactive surface coatings may be applied to enhance the stability of fixation of the implant, even in difficult clinical cases. It is argued that an improved long-term performance of an implant can only be achieved by considering the biomechanics and biomaterials aspects of joint replacement together, and at the same time guaranteeing the quality of surgery by providing the surgeon with better pre-surgical planning systems and advanced surgical tools.

Biocompatible Materials↗

The influence of bone mechanical properties and implant fixation upon bone loading around oral implants.

Finite element models were created to study the stress and strain distribution around a solitary Brånemark implant. The influence of a number of clinically relevant parameters was examined: bone-implant interface (fixed bond versus frictionless free contact), bone elastic properties, unicortical versus bicortical implant fixation and the presence of a lamina dura. Bone loading patterns in the vicinity of the implant seem to be very sensitive to these parameters. Hence they should be integrated correctly in numerical models of in vivo behaviour of oral implants. This necessitates the creation of patient-dependent finite element models.

Biomechanical Phenomena↗

Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog.

The influence of axial and non-axial occlusal loads on the bone remodelling phenomena around oral implants in an animal experiment is simulated in a finite element analysis. The axial and non-axial loading conditions were introduced by inserting a bilaterally supported fixed partial prosthesis and a cantilever fixed partial prosthesis on two IMZ implants in the mandible of beagle dogs. Earlier quantitative and qualitative histological analyses revealed a statistically significant different remodelling response between both loading conditions. Two-dimensional and three-dimensional models are built to analyse and compare von Mises equivalent stress, maximum principal stress, maximum principal strain and strain energy density distributions, first around a free-standing implant and subsequently around the implants of the two prosthesis designs under the respective resultant in vivo loads. Strong correlations between the calculated stress distributions in the surrounding bone tissue and the remodelling phenomena in the comparative animal model are observed. It is concluded that the highest bone remodelling events coincide with the regions of highest equivalent stress and that the major remodelling differences between axial and non-axial loading are largely determined by the horizontal stress component of the engendered stresses.

Alveolar Process↗

Prediction of vertebral and femoral strength in vitro by bone mineral density measured at different skeletal sites.

The aim of the present study was to investigate the prediction of vertebral and femoral strength in vitro by bone mineral density (BMD) measured at different skeletal sites. The third lumbar vertebral body, the right proximal femur, and the right calcaneus were removed from 38 male and 32 female cadavers (mean age 69 years, range 23-92 years). Areal BMD of all bone specimens was determined by dual-energy X-ray absorptiometry (DXA). The failure load of the vertebral body and the femur was determined by mechanical testing. Vertebral and femoral strength were both greater in males than females (p < 0.01), as was BMD at all sites (p < 0.01). Vertebral strength correlated well with vertebral BMD (r2 = 0.64) but was only moderately correlated with BMD measured at the femur (r2 = 0.36) or the calcaneus (r2 = 0.18). Femoral strength showed the highest correlations with femoral BMD (r2 = 0.88) and somewhat weaker relationships with BMD at the vertebra (r2 = 0.50) and the calcaneus (r2 = 0.54). BMD values at the vertebra, femur, and calcaneus were only moderately interrelated (r2 = 0.31-0.65), and vertebral strength correlated only modestly with the strength of the femur (r2 = 0.36). These in vitro results support the concept that optimal prediction of vertebral or femoral strength by DXA requires site-specific assessments.

Absorptiometry, Photon↗

Structural and material mechanical properties of human vertebral cancellous bone.

The structural Young's modulus (i.e. that of the cancellous framework) was determined by non-destructive compressive mechanical testing in the three orthogonal axes of 48 vertebral bone cubes. In addition, the material Young's modulus (i.e. of the trabeculae themselves) was estimated using an ultrasonic technique. Apparent and true density were determined by direct physical measurements. Significant mechanical anisotropy was observed: mean structural Young's modulus varied from 165 MPa in the supero-inferior direction to 43 MPa in the lateral direction. Structural Young's modulus correlated with apparent density, with power-law regression models giving the best correlations (r2 = 0.52-0.88). Mechanical anisotropy increased as a function of decreasing apparent density (p < 0.001). Material Young's modulus was 10.0 +/- 1.3 GPa, and was negatively correlated with apparent density (p < 0.001). In multiple regression models, material Young's modulus was a significant independent predictor of structural Young's modulus only in the supero-inferior direction. The data suggest the presence of two effects in vertebral bone associated with decreasing apparent density and, by implication, bone loss in general: (a) increased mechanical anisotropy, such that there is relative conservation of stiffness in the axial direction compared with the transverse directions; and (b) increased stiffness of the trabeculae themselves.

Adult↗

The use of an advanced reciprocating gait orthosis by paraplegic individuals: a follow-up study.

This article describes the results of a follow-up study of 14 paraplegic individuals who were fitted with the ARGO (Advanced Reciprocating Gait Orthosis--STEEPER) at least 1 year previously. It was found that 85% were still using the apparatus on a regular basis. The general satisfaction of the users was high, although the functional use was limited. Therapeutic reasons appeared to be the main reason for wearing the ARGO. The points that were most appreciated were the psychological and physiological benefits of standing and walking. Discussion with the users who were paraplegic provided valuable information concerning possible technical improvements to the ARGO.

Adolescent↗