Percutaneous closure of a ventricular septal defect after surgical treatment of hypertrophic cardiomyopathy.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G Van Nooten.
Explore the source record for details and available documents.
The feasibility of an anaesthetic protocol developed for surgery during right heart bypass in sheep is reported. Seven female Suffolk sheep, weighing 25-35 kg, were selected for the study. Premedication consisted of midazolam and methadone (both 0.1 mg kg(-1) intravenously). Anaesthesia was induced with propofol (2-4 mg kg(-1)) and maintained with isoflurane in oxygen and continuous rate infusions of propofol (5-7 mg kg(-1 )h(-1)) and fentanyl (5 microg kg(-1) bolus, 5 microg kg(-1) h(-1)). Cisatracurium (0.2 mg kg(-1)) provided muscle relaxation. A standard roller pump was used for the extracorporeal circulation. Drugs administered to maintain blood pressure and heart rate within acceptable levels included phenylephrine (3-4 microg kg(-1)), ephedrine (0.1-0.2 mg kg(-1)), nitroglycerine (50-150 microg kg(-1) h(-1)) and metoprolol succinate (30-80 microg kg(-1)). Electrolytes were infused as needed. Postoperative analgesia was provided by an intercostal block (15 mL 0.5% bupivacaine + epinephrine), carprofen (4 mg kg(-1)) and an opioid (methadone 0.1 mg kg(-1) or buprenorphine 0.01 mg kg(-1)). One sheep became hypoxic during the bypass (PaO(2) 47.7 mmHg). Irregularities of the electrocardiogram were observed during manipulation of the heart in all animals. During the initial phase of the bypass, blood pressure decreased in all sheep, accompanied by dilatation of the heart and large intrathoracic veins in five sheep. With appropriate treatment, blood pressure was restored and easily maintained until the end of the bypass. Weaning from the bypass, using an infusion of nitrates, was smooth. One sheep required a blood transfusion because of severe blood loss and another sheep died postoperatively from respiratory complications. Minor irregularities of the electrocardiogram observed during manipulation of the heart were not life threatening and required no treatment. Decreases in blood pressure at the beginning of the bypass can be expected and require treatment. Nitrates are useful in avoiding volume overload during weaning. The anaesthetic protocol is acceptable for surgery under right heart bypass in sheep.
We compared the cerebrovascular response to various cognitive tasks of cardiovascular patients and healthy controls by using transcranial Doppler ultrasonography (TCD). Cognitive task-induced cerebral blood flow velocity (BFV) changes in 66 candidates for coronary artery bypass graft surgery (mean age 59.4 +/- 7.5) were compared with the functional BFV measurement of 60 healthy controls (mean age 58 +/- 7). Absolute BFV values during baseline and activation were monitored with TCD. Relative increase of the BFV was calculated from the immediately preceding rest period to the following activation. A manova with group (patients versus controls) as between-subjects factor showed no differences in absolute BFV during the rest period. For absolute BFV during activation, a significant difference between the two groups was found. Although for each test the percentage change was smaller in the cardiac group, the difference just failed to reach significance. An explorative multivariate linear regression analysis with the absolute activation and percentage change as dependent variables and coronary risk factors as independent variables revealed no significant predictors. Using functional TCD we found that BFV values during activation were significantly lower in cardiac patients compared with healthy controls. Future research should focus on the possible explanations of this phenomenon.
BACKGROUND: to determine the advantages and/or risks of minimal access aortic valve replacement compared to standard sternotomy procedure. METHODS: from January 1997 to December 2001, 271 consecutive adult patients underwent isolated aortic valve replacement of which 174 underwent a minimal access procedure (Group 1) and 97 a standard procedure (Group 2). The preoperative variables of both groups were comparable. Retrospective analysis of postoperative outcome was performed. RESULTS: follow-up was complete and ranged from 6 months to 4 years. Overall in-hospital mortality was 3.3% (respectively 2.8 and 4.1%). No statistical difference was noted regarding operative time variables, mortality rate and hospital stay. There was a significant higher incidence of revision (p = 0.018) and late pericardial effusion (p = 0.022) in the minimal access group. Also trends were in favour of the standard group for incidence of postoperative pneumothorax and pericarditis constrictiva. CONCLUSIONS: minimal access aortic valve replacement is a safe and reliable technique, but carries the risk of incision-related morbidity. Proper patient selection and perioperative management is mandatory.
OBJECTIVE: In a retrospective study, we compared two groups of consecutive patients operated by the same team during the year 2000 for coronary artery disease with the use of extracorporeal circulation (group 1, n=230) or on the beating heart using the Octopus II plus stabiliser (group 2, n=228). High-risk patients were identified by a EuroSCORE plus 6. EuroSCORE definitions and predicted risk models were utilized to compare the variables of the groups. METHODS: There were no significant differences between the preoperative variables of the groups in age, gender, left ventricular function, diabetes and peripheral vascular and renal disease as is indicated by the Euroscore (resp. 4.7/5.1 p=0.107). Calcification of the ascending aorta and chronic obstructive lung disease were statistically significant more prevalent in the beating heart group. No differences in preoperative variables in the high-risk patients group (Euroscore 8.5/8.1 p=0.356) except for calcification of the ascending aorta. RESULTS: All patients underwent a full revascularisation through a midline sternotomy. Significant more distal anastomoses were performed in group 1 (3.7 per patient (1-6)) with regard to group 2 (2.9 per patient (1-6)). Anesthesia, postoperative treatment and follow up were equal for both groups. A significant lower incidence of atrial fibrillation (p=0.010), shorter ICU stay (p=0.031) and renal insufficiency (p=0.033) was reported in group 2. In the low risk group, we could not diagnose any difference between the two groups, except for atrial fibrillation. The benefits of the beating heart surgery however were more pronounced in the high-risk patient as is indicated by a significant reduction of the ICU stay by 1 day (3.5d/2.5d (p=0.028)), better preservation of the renal function (p=0.017) and a significant reduction of the length of hospital stay by more than two days (p=0.040). A lower incidence of atrial fibrillation, however not significant. CONCLUSION: In our experience, beating heart surgery is a safe alternative for conventional coronary heart surgery. High-risk patients do benefit most from this technique. It became our first choice in the elderly patient and patients presenting with higher co-morbidities.
OBJECTIVE: The aim of the study is to explore the feasibility and mid-term patency of an easier anastomotic technique for Minimally Invasive Direct Coronary Bypass Grafting (MIDCAB). METHODS: Eight mongrel dogs (+/-15 kg) underwent direct anastomosis between the left internal thoracic artery (LITA) and the left anterior descending coronary artery (LAD) via inferior sternotomy on the beating heart. After positioning the graft, the distal part of the LAD was opened to allow retrograde filling of the LITA-graft. The anastomosis was secured by the use of biological glue (BioGlue, Cryolife, Marietta, GA, USA). No intravascular suture material was used. Ischemic time averaged 6 min. The proximal LAD was occluded upstream the arteriotomy. All survivors were angiographically controlled for patency after 6-8 weeks. Consequently, four dogs were sacrificed after 6 weeks and the remaining after 3 months for anatomo-pathological and histological examination by light and electron microscopy of the anastomotic site. RESULTS: All procedures were successful except for one animal that died of uncontrollable bleeding at the anastomotic site. Another sustained post-operative transmural anterior myocardial infarction due to a late graft occlusion. All angiographically controlled grafts were patent with two vascular strings near the anastomotic site. Histology showed early macrophage infiltration into the glue. At post-mortem examination, new endothelialization was noticed in 80% of the cases. However, ultrastructural examination detected marked differences in endothelial fibroblastic lining compared to normal histology. CONCLUSIONS: Good mid-term permeability of the LITA grafts was observed in this new anastomotic technique for MIDCAB in the canine model. Although neo-endothelialization was present in most cases, ultrastructural differences were noticed after 3 months in the neo-intima compared to normal.
Explore the source record for details and available documents.
OBJECTIVE: This study investigates the influence of foreign material and blood aspirated from nonvascular structures on activation of coagulation, hemolysis, and blood loss. METHODS: The series comprises 3 randomized groups (groups C, S, and S+P) of 10 patients undergoing routine coronary artery bypass grafting with cardiopulmonary bypass. In group C, the control group, all aspirated blood was returned into the circulation. In group S suction blood was discarded, whereas group S+P was identical to group S, with surfaces coated with phosphorylcholine. Plasma concentrations of beta-thromboglobulin, thrombin generation, haptoglobin, and free hemoglobin, as well as blood loss, were measured. RESULTS: A steady increase in free plasma hemoglobin, as well as an increased generation of thrombin, was noticed in group C. Moreover, a close correlation (r = 0.916) between the generation of thrombin and its inhibition (thrombin-antithrombin complexes) was observed. Platelets were clearly activated in group C and, to a lesser extent, in group S. In contrast, platelet activation in group S+P was negligible, resulting in a 30% decrease in blood loss (P =.05). CONCLUSIONS: Aspirated blood contaminated by tissue contact is the most important activator of the coagulation system and the principal cause of hemolysis during cardiopulmonary bypass. Contact with a foreign surface is not a main variable in the procoagulant effect of bypass. Mimicking the outer cell membrane structure resulted in decreased platelet activation and decreased blood loss.
The aim of this study was to perform combined hydrodynamic and Doppler echocardiographic tests of the Omnicarbon 21 mm cardiac valve in aortic position in our Pulse Duplicator System for simultaneous assessment of valve performance and valve leakage data. During forward flow conditions, measured mean pressure gradients are between 4.5 and 20.2 mmHg (11.9 +/- 4.4 mmHg) for cardiac outputs between 3.6 and 5.3 /min (4.5 +/- 0.4 /min). Doppler-derived mean pressure gradients are between 2.0 and 170 mmHg (9.3 +/- 3.9 mmHg) for the same flow conditions. Effective Orifice area is 1.31 +/- 0.08 cm2 and the performance index is 0.74 +/- 0.04, using the actual geometric orifice area, and 0.38 +/- 0.02, using the tissue annulus diameter, for a cardiac output of 4.5 +/- 0.4 l/min. Regurgitation volumes are below 3 ml. There is a trend to an effect of valve orientation on hemodynamics.
Six different commercially available paediatric venous cannulae, together with a specially constructed cannula, were tested in vitro for their pressure-flow relationship. With the cannulae placed in an open reservoir, flow increased with larger diameters and higher pressures. At a pressure of 30 cm H2O, flows were 219 +/- 20, 285 +/- 13, 422 +/- 11 and 728 +/- 4 ml/min for the 12, 13.2, 14 and 16 French, respectively. No differences were found between angled and straight cannulae. When the cannulae were tested in a latex model simulating the right atrium and vena cavae, the highest flow obtained by gravity was 164 ml/min using an angled 14-French cannula. When vacuum was applied to augment venous return, a maximum flow of 179 ml/min was measured using an angled 14-French cannula. Collapse can occur when the pressure difference becomes too high in the test system. This is important, since most children are selectively cannulated in both major veins. Monitoring of the intravascular pressure might help to prevent collapse. A larger-diameter venous cannula does not always produce the highest flow when placed in a vein. This is most obvious when augmenting venous return. The design of the cannula tip, in combination with VAVD, can affect the venous return.
BACKGROUND: Redo-CABG surgery remains extremely hazardous in the presence of open bypass grafts. In our patients with mitral valve pathology with open and well-functioning bypass grafts, we explored alternative approaches in order to avoid damage to the grafts by extensive dissection and direct clamping of the ascending aorta. The "Estech procedure," which uses the Estech remote access perfusion (RAP) endoclamp catheter (Estech Inc., Danville, CA), was selected for these patients. METHODS: From January 1998 to January 2000, 10 patients underwent an Estech procedure for redo mitral surgery. All patients had previous cardiac operations such as coronary artery bypass grafting (CABG) and/or mitral valve procedures. The Estech procedure consisted of an anterior left thoracotomy and peripheral cannulation at femoral site using the Estech endovascular balloon technique. The series was comprised of seven mitral valve replacements, two valve reconstructions, and one closure of a paravalvular leak. One procedure had to be converted to a standard re-sternotomy due to extreme arteriosclerosis of the descending aorta with plaque dislocation at the time of catheter insertion. However, no damage was inflicted to the open bypass grafts. RESULTS: The follow-up period ranged from six to 30 months and was 100% complete. We encountered one hospital death in our group, which was due to a late post-operative intestinal infarction and multiple organ failure (MOF), and was not procedure related. As expected, morbidity was high in this compromised cohort, but no late death has occurred prior to submission of this article. All survivors progressed to an acceptable NYHA functional class. CONCLUSION: The excellent results in this complex patient group inspired us to use the Estech procedure as a standard approach for redo mitral surgery.
OBJECTIVE: The aim of this study is to evaluate the use of a new coating, mimicking the outer cell membrane, in paediatric cardiac surgery. METHODS: Two groups of ten patients with a body weight below 8 kg, undergoing elective cardiac operations for different congenital anomalies, were prospectively enrolled in this study. In one group the whole extracorporeal circuit, including the cannulas, was coated with phosphorylcholine (PC). In the second group the same circuit was used without coating. Platelet activation (thromboxane B2 (TXB2), beta-thromboglobulin (betaTG)), activation of the coagulation system (F1+2), leukocyte activation (CD11b/CD18) and terminal complement activation (TCC) were analyzed pre-cardiopulmonary bypass (CPB), at 15, 60 min of CPB, at the end of CPB, 20 min post CPB and at postoperative day 1 and 6. RESULTS: No statistical differences were found for F1+2 and CD11b/CD18. After onset of CPB mean levels of TCC remained stable in the PC group whereas an increase was observed in the control group. During CPB betaTG values in both groups increased to a maximum at the end of CPB. Within groups the increase in betaTG levels during CPB was statistically significant (P<0.05) from baseline in the control group starting from 60 min of CPB whereas no statistical difference was observed in the PC group. After the start of CPB TXB2 mean levels increased to 405+/-249 pg/ml in the PC group vs. 535+/-224 pg/ml in the control group. After this initial increase there was a small decline in the PC group with further increase. This was in contrast to the control group were TXB2 levels further increased up to a mean of 718+/-333 pg/ml at the end of CPB (P=0.016). CONCLUSIONS: Phosphorylcholine coating had a favourable effect on blood platelets, which is most obvious after studying the changes during cardiopulmonary bypass. A steady increase of TXB2 and betaTG was observed in the control group, whereas plateau formation was observed in the phosphorylcholine group. Clinically, this effect may contribute to reduced blood loss and less thromboembolic complications. Complement activation is lower in the coated group.
OBJECTIVES: Correct assessment of contractility by conventional methods during manipulation of afterload is often disappointing. To this purpose, the stress-velocity relationship offers assessment of contractility at different levels of afterload. We decided to study the influence of afterload on the nature of the stress-velocity relation. BACKGROUND: Although linear at baseline conditions in a population older than two years, data in newborns or after administration of low-dose dobutamine suggest a different nature of this relationship at low afterload. METHODS: Ten healthy piglets (five to six weeks; 11 to 13 kg) were studied. End-systolic meridional wall stress (ESWS) and rate-corrected velocity of circumferential fiber shortening (VcFc) were measured in these piglets at baseline, after balloon occlusion of the descending aorta, and at nitroprusside infusion rates of 1, 2 and 5 microg/kg/min. To eliminate inotropic influences mediated by reflex tachycardia, we subsequently studied five piglets and six adult pigs after bilateral cervical vagotomy. RESULTS: The ESWS changed from a baseline mean of 50 g/cm2 to 137 g/cm2 after balloon occlusion and to 19 g/cm2 at 5 microg/kg/min of nitroprusside. The VcFc changed from 1.19 c/s (circumference/second) to values of 0.9 c/s and 1.73 c/s, respectively. The ensuing stress-velocity regression line proved to be curvilinear instead of linear. The steeper slope at low afterload could suggest enhanced contractility compared to expected values had the relationship been linear. CONCLUSIONS: Data from young piglets and adult pigs suggest a curvilinear relationship of the stress-velocity relationship. This could probably explain some of the "hypercontractile states" encountered in conditions with low afterload.
OBJECTIVE: To assess differences in indication and mid-term results between stentless and stented procedures in elderly patients, we followed aortic valve patients over a period of 5 years. METHODS: In a consecutive series of 154 elderly aortic patients in regular sinus rhythm from 1992 to 1997, we inserted 103 stentless (Toronto SPVTM, St Jude Medical Inc., St Paul, Minneapolis, MN) and 51 stented (Carpentier-Edwards supra annular porcine, Baxter Inc., Irvine, CA) bioprostheses in the aortic position. RESULTS: All 154 patients seemed preoperatively eligible for a stentless procedure. Mean age was 74.8 years (range 67-86 years) with a majority of female patients. The surgeon's (in)experience, major dilatation or calcifications of the ascending aorta and aberrant coronary anatomy were the most common reasons for drawback from the stentless procedure (51/154 patients). Aortic clamp time was significantly higher in the stentless vs. stented group (70 vs. 57 min, P < 0.0001). The large average 25.3 mm size of the stentless prostheses (vs. 23.7 mm stented) stands in full contrast with the low mean body surface area of 1.68 m2 (vs. 1.70 m2) of the patients. We encountered. respectively. 5 and 2 hospital-deaths (P = n.s.). The follow-up period ranged from 6 to 66 months and was 97% complete, yielding, respectively, 302 and 139 patient-years. Survival (Kaplan-Meier method) was statistically higher in favor of the stentless procedures (log rank: P = 0.03). All survivors progressed markedly to a mean postoperative NYHA class 1.3 respectively, 1.4 (vs. preop. 3.3 and 3.2). Echocardiographic transvalvular gradients compared favorable for the stentless group in the small under 25 mm valves (P = 0.02 for 23 mm sized valves between groups) with improved left ventricular function and a significant decrease of left ventricular end diastolic diameter (LVEDD 48.0 vs. 56.5 mm) at 1 year follow-up. Cusp calcifications on control echocardiography were detected earlier (beyond 3 years) in the stented group, without signs of early significant regurgitation or dysfunction in both groups, except for one patient necessitating re-operation. CONCLUSION: Although the implantation technique is much more demanding for stentless procedures, reflected by a longer aortic clamp-time, and remains impossible in some cases, elderly, small sized patients take full benefit of their large, non-obstructive prostheses.
Explore the source record for details and available documents.
BACKGROUND: Our study evaluated the efficacy and feasibility of a pumpless respiratory assist device and determined its capacity for carbon dioxide removal. METHODS: In five adult pigs the left femoral vein and artery were cannulated with a 20F cannula and connected to a low-pressure hollow-fiber artificial lung. After we had obtained baseline values of mean arterial pressure, cardiac output, and blood flow across the artificial lung, the mean arterial pressure was reduced 20% and 40% relative to baseline; in a second phase, it was raised 20% and 40. Cardiac output and artificial lung flow were simultaneously recorded. We determined the carbon dioxide removal capacity of the artificial lung by gradually increasing the arterial partial carbon dioxide tension of the animal. RESULTS: An increase of 10 mm Hg in mean arterial pressure resulted in an increase of flow of 0.14 L/min. The mean pressure drop across the artificial lung was measured at 17 +/- 9 mm Hg. The shunt flow over the artificial lung varied between 14 and 25% of the cardiac output of the animal. Depending on inlet conditions, carbon dioxide removal by the artificial lung was between 62 +/- 22 mL/L/min and 104 +/- 25 mL/L/min. CONCLUSIONS: A pumpless respiratory assist device can remove a significant proportion of the metabolic carbon dioxide production. However, adequate mean arterial pressure is mandatory to maintain sufficient flow across the device. The technique seems attractive because of its simplicity and can be used in acute lung injury in conjunction of apneic oxygenation for prolonged respiratory support.
BACKGROUND: Propofol's unique pharmacokinetic profile offers advantages for titration and rapid emergence in patients after coronary artery bypass graft (CABG) surgery, but concern for negative inotropic properties potentially limits its use in these patients. The current study analyzed the effect of various propofol plasma concentrations on left ventricular (LV) contractility by means of a single-beat contractile index based on LV maximal power (PWR(max)). METHODS: The study was conducted in 30 patients after CABG surgery. Immediately after admission to the intensive care unit (ICU), four different plasma concentrations of propofol 0.65, 1.30, 1.95, and 2.60 microg/ml were established. At each concentration level, the cardiac and vascular effects of propofol were studied by combining echocardiographic data with invasively derived aortic root pressure. Preload was characterized by LV end-diastolic dimensions. Afterload was indicated in terms of indexed systemic vascular resistance (SVRI), LV end-systolic meridional wall stress (LV-ESWS), and arterial elastance (Ea). Quantification of effects on contractility was achieved by preload-adjusted PWRmax. RESULTS: Myocardial contractility did not change during a fourfold increase in propofol plasma concentration. Preload-adjusted PWRmax amounted to 3.90+/-1.75 W x ml(-2) x 10(4), 3.98+/-1.69, 3.94+/-1.70, and 3.88+/-1.72, respectively (mean+/-SD). With respect to ventricular loading conditions, propofol caused a significant reduction in both pre- and afterload. CONCLUSIONS: The current results strongly suggest that propofol lacks direct cardiac depressant effects. Nevertheless, meaningful vascular actions of propofol could be demonstrated. Significant decreases in ventricular loading conditions accounted for a marked decrease in arterial blood pressure and supported the concept that propofol in clinically relevant concentration is a vasodilator.
We have evaluated the effect of nitric oxide (NO) on the pressure drop across a membrane oxygenator in one in vitro model and two in vivo models (using four dogs and five pigs). In all the experiments sodium nitroprusside (SNP) was used as a NO source, whereas gaseous NO was only used in the in vitro model. The drugs were given when the pressure drop or resistance across the device increased to at least twice the baseline values. In the in vitro model, both SNP and gaseous NO decreased the pressure drop to 75% of its peak value after 10 min and to 67% after 20 min. In the dog model, resistance decreased from 390 to 153 mmHg/l/min after 5 min and to 85 mmHg/l/min after 20 min for a baseline value of 75 mmHg/l/min. The initial resistance across the membrane oxygenator in the pig model increased from 6.6+/-1.3 to 74+/-38 mmHg/l/min. An infusion of 10 microg/kg/min SNP reduced the resistance to 16+/-5 mmHg/l/min.