Search PubMedSearch

Biomedical subjects

G V Heller

Publications and source records attributed to G V Heller.

At least 19 recordsLinked to original sources

Functional assessment with electrocardiographic gated single-photon emission computed tomography improves the ability of technetium-99m sestamibi myocardial perfusion imaging to predict myocardial viability in patients undergoing revascularization.

This study evaluates the use of electrocardiographic (ECG) gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging for the prediction of viability in patients undergoing revascularization, who have coronary disease and left ventricular dysfunction. Fifty patients underwent technectium-99m (Tc-99m) sestamibi ECG gated SPECT imaging preoperatively at rest and 1 week after revascularization, whereas 36 (72%) also underwent imaging 6 weeks after revascularization. Images were interpreted by the consensus of 3 experienced readers without knowledge of patient identity or time of imaging (pre- or postrevascularization) for perfusion and wall motion using a 17-segment model. Results of perfusion alone were compared with perfusion and wall motion combined. One hundred five coronary artery territories were revascularized, 96 of which were viable and 9 nonviable. Perfusion alone predicted 87 to be viable and 18 nonviable (sensitivity 86%, specificity 55%, positive predictive value 95%, negative predictive value 28%, and overall accuracy 85%). Perfusion and wall motion combined identified 95 territories to be viable (sensitivity 95%; p <0.025; specificity 55%, positive predictive value 96%, negative predictive value 50%, and overall accuracy 91%; p <0.05). Thus, Tc-99m sestamibi ECG gated SPECT myocardial perfusion imaging at rest allows assessment of both perfusion and wall motion, which significantly improves the sensitivity and overall accuracy for determination of viability in comparison with perfusion alone.

Aged

The economic consequences of available diagnostic and prognostic strategies for the evaluation of stable angina patients: an observational assessment of the value of precatheterization ischemia. Economics of Noninvasive Diagnosis (END) Multicenter Study Group.

OBJECTIVES: The study aim was to determine observational differences in costs of care by the coronary disease diagnostic test modality. BACKGROUND: A number of diagnostic strategies are available with few data to compare the cost implications of the initial test choice. METHODS: We prospectively enrolled 11,372 consecutive stable angina patients who were referred for stress myocardial perfusion tomography or cardiac catheterization. Stress imaging patients were matched by their pretest clinical risk of coronary disease to a series of patients referred to cardiac catheterization. Composite 3-year costs of care were compared for two patients management strategies: 1) direct cardiac catheterization (aggressive) and 2) initial stress myocardial perfusion tomography and selective catheterization of high risk patients (conservative). Analysis of variance techniques were used to compare costs, adjusting for treatment propensity and pretest risk. RESULTS: Observational comparisons of aggressive as compared with conservative testing strategies reveal that costs of care were higher for direct cardiac catheterization in all clinical risk subsets (range: $2,878 to $4,579), as compared with stress myocardial perfusion imaging plus selective catheterization (range: $2,387 to $3,010, p < 0.0001). Coronary revascularization rates were higher for low, intermediate and high risk direct catheterization patients as compared with the initial stress perfusion imaging cohort (13% to 50%, p < 0.0001); cardiac death or myocardial infarction rates were similar (p > 0.20). CONCLUSIONS: Observational assessments reveal that stable chest pain patients who undergo a more aggressive diagnostic strategy have higher diagnostic costs and greater rates of intervention and follow-up costs. Cost differences may reflect a diminished necessity for resource consumption for patients with normal test results.

Angina Pectoris

Combined assessment of myocardial perfusion and left ventricular function with exercise technetium-99m sestamibi gated single-photon emission computed tomography can differentiate between ischemic and nonischemic dilated cardiomyopathy.

The purpose of this study was to determine whether exercise technetium-99m sestamibi gated single-photon emission computed tomography (SPECT) accurately distinguishes between patients with ischemic cardiomyopathy and patients with nonischemic left ventricular systolic dysfunction. Noninvasive tests have previously failed to accurately separate patients with ischemic cardiomyopathy from those with nonischemic cardiomyopathy. Technetium-99m gated SPECT imaging offers advantages that have the potential to overcome the limitations of previous studies. Thirty-seven adults with a left ventricular ejection fraction < or = 35%, including 24 patients with nonischemic cardiomyopathy and 13 patients with ischemic cardiomyopathy, were prospectively evaluated using symptom-limited metabolic exercise treadmill testing with technetium-99m sestamibi gated SPECT imaging. Interpretation of myocardial perfusion and regional wall motion was performed, using a 17-segment model. Summed stress, rest, and reversibility perfusion defect scores were determined, and the variance of segmental wall motion scores was computed. Summed stress, rest, and reversibility perfusion defect scores were significantly lower in nonischemic cardiomyopathy patients, compared with those with ischemic cardiomyopathy (summed stress defect score: 6.9 +/- 3.8 vs 32.9 +/- 7.7, respectively, p <0.001). Variability in segmental wall motion was also significantly lower in patients with nonischemic cardiomyopathy compared with those with ischemic cardiomyopathy (variance: 0.3 +/- 0.3 vs 1.2 +/- 0.8, respectively, p <0.001). Thus, assessment of myocardial perfusion and regional ventricular function with exercise technetium-99m sestamibi gated SPECT imaging can reliably distinguish between patients with ischemic cardiomyopathy and patients with nonischemic dilated cardiomyopathy.

Adult

Dipyridamole-dobutamine stress with Tc-99m sestamibi tomographic myocardial perfusion imaging.

In 66 patients unable to exercise referred for pharmacologic stress single-photon emission computed tomographic myocardial perfusion imaging, a moderate dose of dobutamine was combined with intravenous dipyridamole and the results were compared with standard intravenous dipyridamole stress. The combined stress protocol resulted in increased defect size and reversibility with technetium-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging.

Aged

Influence of race on the prediction of cardiac events with stress technetium-99m sestamibi tomographic imaging in patients with stable angina pectoris.

The prognostic value of myocardial perfusion imaging in African-Americans is unknown. This study compared the prediction of cardiac events of stress technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) imaging in symptomatic Caucasian and African-American patients. Prospectively collected stress Tc-99m sestamibi tomographic imaging data from 4 medical centers, with follow-up information in 1,086 Caucasian and African-American patients, were analyzed in a core statistical laboratory. Primary events of cardiac death and nonfatal myocardial infarction and secondary events of all-cause mortality were analyzed using Kaplan-Meier survival analysis and Cox proportional-hazards multivariable model. Normal images in both African-Americans and Caucasians were associated with a low-annual cardiac event rate, whereas abnormal images were significantly associated with a higher cardiac event rate. The highest predictor of cardiac events was multivessel abnormality in both races. Use of this technique could identify patients at high risk and potentially reduce the high-cardiac event rate in African-Americans by utilizing appropriate therapies.

Aged

Clinical value of acute rest technetium-99m tetrofosmin tomographic myocardial perfusion imaging in patients with acute chest pain and nondiagnostic electrocardiograms.

OBJECTIVES: We sought to evaluate the clinical use and cost-analysis of acute rest technetium-99m (Tc-99m) tetrofosmin single-photon emission computed tomographic (SPECT) myocardial perfusion imaging in patients with chest pain and a normal electrocardiogram (ECG). BACKGROUND: Current approaches used in emergency departments (EDs) for treating patients presenting with chest pain and a nondiagnostic ECG result in poor resource utilization. METHODS: Three hundred fifty-seven patients presenting to six centers with symptoms suggestive of myocardial ischemia and a nondiagnostic ECG underwent Tc-99m tetrofosmin SPECT during or within 6 h of symptoms. Follow-up evaluation was performed during the hospital period and 30 days after discharge. All entry ECGs, SPECT images and cardiac events were reviewed in blinded manner and were not available to the admitting physicians. RESULTS: By consensus interpretation, 204 images (57%) were normal, and 153 were abnormal (43%). Of 20 patients (6%) with an acute myocardial infarction (MI) during the hospital period, 18 had abnormal images (sensitivity 90%), whereas only 2 had normal images (negative predictive value 99%). Multiple logistic regression analysis demonstrated abnormal SPECT imaging to be the best predictor of MI and significantly better than clinical data. Using a normal SPECT image as a criterion not to admit patients would result in a 57% reduction in hospital admissions, with a mean cost savings per patient of $4,258. CONCLUSIONS: Abnormal rest Tc-99m tetrofosmin SPECT imaging accurately predicts acute MI in patients with symptoms and a nondiagnostic ECG, whereas a normal study is associated with a very low cardiac event rate. The use of acute rest SPECT imaging in the ED can substantially and safely reduce the number of unnecessary hospital admissions.

Electrocardiography

The pharmacokinetics of intravenous testosterone in elderly men with coronary artery disease.

Intracoronary testosterone injections have recently been shown to possess coronary vasodilating effects. The same may be true for intravenous testosterone, but the pharmacokinetic and hemodynamic aspects need exploration before pharmacologic studies can begin. This trial determined the pharmacokinetic and hemodynamic properties of 300 microg of testosterone given intravenously. Degree of testosterone aromatization to 17-beta estradiol after exogenous administration and overall patient tolerability also were evaluated. Eleven elderly men with coronary artery disease participated in the study and were given 300 microg of testosterone intravenously over 10 minutes. Serum blood concentrations of testosterone and 17-beta estradiol were measured at baseline and then periodically. Testosterone serum concentrations were stripped and fit to a two-compartment model for all patients. The volume of distribution (Vdarea) was 80.36 +/- 24.51 L, and the elimination half-life was 55.93 +/- 23.06 minutes. No hemodynamic differences or side effects were noted. The serum concentrations of 17-beta estradiol were significantly increased from baseline beginning 5 minutes after infusion to the end of the study (180 minutes after infusion).

Aged

Effect of time on liver clearance of technetium-99m-tetrofosmin in patients with acute chest pain: when should imaging begin?

OBJECTIVE: Due to stable myocardial retention and technetium imaging characteristics, 99mTc-tetrofosmin has been considered potentially useful for acute chest pain imaging. Tetrofosmin also has favorable biokinetics with reported rapid liver clearance, 5 min poststress and 30-45 min post-rest injection. Since comparable data are not available, the effect of time on liver clearance was evaluated in patients with acute chest pain. METHODS: One hundred six patients received an intravenous injection of 25-30 mCi 99mTc-tetrofosmin to evaluate acute chest pain. SPECT imaging was performed 15-120 min after injection of the tracer. Patient images were grouped according to the time of acquisition after acute injection: 15-30 min, 31-45 min, 46-60 min, 61-90 min and > 90 min. Quantitative analysis was performed of a similar anterior projection for each patient consisting of 6 X 6-pixel region of interest over the myocardium and adjacent liver. Average counts per pixel were determined and a heart/liver (H/Li) ratio was calculated. RESULTS: The mean H/Li ratio was < 1.0 for patient images acquired 15-45 min after injection, and > 1.0 for patient images acquired after 45 min. The difference was statistically significant (p < 0.05). CONCLUSION: Quantitative analysis suggests that the optimal imaging time should be at least 45 min after the injection of 99mTc-tetrofosmin to allow adequate liver clearance before image acquisition of acute chest pain syndromes.

Aged

Fasting and nonfasting iodine-123-idophenylpentadecanoic acid myocardial SPECT imaging in coronary artery disease.

UNLABELLED: Iodine-123-labeled idophenylpentadecanoic acid (IPPA) metabolic imaging has been shown to be clinically useful for the identification of myocardial viability in patients with coronary artery disease and left ventricular dysfunction. Imaging is usually performed under fasting conditions since nonfasting conditions may affect myocardial uptake of 123I-IPPA. The purpose of this study was to examine the impact of dietary condition on 123I-IPPA metabolic imaging. METHODS: Forty patients with stable coronary artery disease underwent, in randomized order and on separate days, 123I-IPPA SPECT myocardial imaging under fasting and nonfasting conditions. Patients were injected with 123I-IPPA (4-5 mCi) at rest with imaging performed at 4 (initial) and 30 (delay) min. For each image (initial and delay images), 10 segments were analyzed by three experienced observers without knowledge of patient identity or dietary condition using a 5-point grading system (O = no uptake to 4 = normal uptake). A summed global score was obtained for each image by adding the scores for all 10 segments. Image quality was assessed using a 3-point grading system. RESULTS: Visual agreement for normal and abnormal segments between fasting and nonfasting conditions was 82% (kappa = 0.63). There were no significant differences in the summed global scores for both conditions. Image quality was equivalent for both conditions in 65% of cases and superior under the nonfasting condition in 25% of cases. CONCLUSION: Image quality as well as the presence, location and severity of defects are similar under fasting and nonfasting conditions with 123I-IPPA. Therefore, fasting is not necessary before 123I-IPPA SPECT imaging for the assessment of myocardial viability.

Adult

Evaluation of technetium-99m red blood cell labeling efficiency in adults receiving chemotherapy and the clinical impact on pediatric oncology patients.

OBJECTIVE: Technetium-99m-labeled RBCs are used to evaluate ventricular function and are the preferred method for monitoring the cardiac function of patients receiving chemotherapy. Optimal imaging quality is critical for monitoring small but important changes in ventricular function. The labeling efficiency of three products from two manufacturers and images from 30 patients (21 men, 9 women; age 60.3 +/- 11.9 yr) referred for clinical radionuclide ventriculograms before chemotherapy were evaluated to determine the best labeling technique. METHODS: Patients received RBCs labeled in one of three ways. Two pyrophosphate methods used a modified in vitro method and the manufacturer's instructions were used for the in vitro method. Imaging was performed and, upon completion (42.1 +/- 9.6 min), blood samples were drawn, separated and counted to determine labeling efficiency. RESULTS: The labeling efficiencies were: (a) 88.1% +/- 4.2% and (b) 88.4% +/- 4.8% for the two modified in vitro methods; and (c) 95.3% +/- 1.7% for the in vitro method. The difference between the methods was statistically significant (p = 0.019). Twenty pediatric oncology patients (6.4 +/- 5.2 yr) received in vitro labeled RBCs through their Hickman catheters. All 20 pediatric studies were of high quality. CONCLUSION: In vitro labeling demonstrated a higher labeling efficiency than the modified in vitro methods. In vitro labeling also yielded high-quality images when the labeled RBCs were injected through existing chronic in-dwelling catheters.

Aged

Direct comparison of arbutamine and dobutamine stress testing with myocardial perfusion imaging and echocardiography in patients with coronary artery disease.

Arbutamine, a new sympathomimetic compound, appears to elicit a more balanced inotropic and chronotropic response than dobutamine, currently used as a pharmacologic stress agent. The present study was performed to compare standard dobutamine stress testing with arbutamine for the detection of myocardial ischemia with technetium (Tc)-99m sestamibi tomographic imaging and 2-dimensional echocardiography in patients with coronary artery disease. Twenty-six patients with evidence of coronary artery disease underwent dobutamine infusion of 5 to 40 microg/kg/min in 3-minute stages. On a separate day, arbutamine was administered by an automated, computerized, closed-loop device monitoring both heart rate and blood pressure. Both infusions were terminated upon achievement of target heart rate, completion of maximal infusion dose (dobutamine), heart rate saturation (arbutamine), or standard clinical end points. Tc-99m sestamibi was injected before termination of both infusions followed by tomographic myocardial perfusion imaging, whereas echocardiography was performed at baseline and throughout the infusions. There were no significant differences in maximal heart rate, blood pressure, and rate-pressure product as well as in the development of anginal symptoms or electrocardiographic changes during both infusions. The location and severity of myocardial perfusion defects and echocardiographic wall motion abnormalities were similar between both agents. It is concluded that arbutamine produces similar imaging results compared with standard dobutamine stress with both Tc-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging and 2-dimensional echocardiography.

Adult

Impact of acute propranolol administration on dobutamine-induced myocardial ischemia as evaluated by myocardial perfusion imaging and echocardiography.

Beta-blocker therapy may delay or completely prevent myocardial ischemia during exercise testing, as assessed by ST-segment shifts, myocardial perfusion defects, or echocardiographic wall motion abnormalities. However, the impact of beta-blocker therapy on these end points during dobutamine stress testing has not been well established. The purpose of this study was to determine the impact of propranolol on dobutamine stress testing with ST-segment monitoring, technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) imaging, and echocardiography. In 17 patients with known reversible perfusion defects, dobutamine stress tests with and without propranolol were performed in randomized order and on separate days, following discontinuation of oral beta blockers and calcium antagonists. Propronolol was administered intravenously to a cumulative dose of 8 mg or to a maximum heart rate reduction of 25% and dobutamine was infused in graded doses in 3 minute stages until a standard clinical end point or the maximum dose of 40 microg/kg/min was achieved. The dobutamine stress test after propranolol was associated with a lower maximum heart rate (83 +/- 18 vs 125 +/- 17, p <0.001) and rate pressure product (14,169 +/- 4,248 vs 19,894 +/- 3,985, p <0.001) despite a higher infusion dose. The SPECT myocardial ischemia score was also lower (6.9 +/- 5.8 vs 10.1 +/- 7.1, p = 0.047) and fewer echocardiographic segments were abnormal (3.4 +/- 3.0 vs 4.6 +/- 3.4, p = 0.042). In 4 of 17 patients, reversible perfusion defects and echocardiographic wall motion abnormalities were detected during the control but not during the propranolol test. Thus, during dobutamine stress testing, beta-blocker therapy attenuates, and in some cases eliminates, evidence of myocardial ischemia.

Aged

Prognostic importance of scintigraphic left ventricular cavity dilation during intravenous dipyridamole technetium-99m sestamibi myocardial tomographic imaging in predicting coronary events.

Left ventricular (LV) cavity dilation during stress myocardial perfusion imaging has been associated with multivessel disease, and may be an independent prognostic marker in addition to perfusion defects. The present study examines the predictive value for future cardiac events of transient or fixed LV dilation during dipyridamole technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) imaging. The study included 512 consecutive patients who underwent SPECT imaging with Tc-99m sestamibi after dipyridamole infusion. Transient LV dilation was seen in 70 patients (14%) and 74 had fixed cavity dilation (14%); cavity size was normal in 368 patients (72%). Each perfusion scan was classified as normal or abnormal, and if abnormal, defects were categorized as transient or fixed, and as small, medium, or large (depending upon the number of abnormal vascular territories). Events during a mean follow-up of 12.8 +/- 6.8 months were tabulated by direct review of hospital charts and death certificates. The cardiac event rate (cardiac death or nonfatal infarction) was 1.9% in patients with normal cavity size, 11.4% with transient LV dilation, and 13.5% with fixed LV dilation (p < 0.01). Compared with patients with normal cavity size, those with transient LV dilation were more likely to sustain a myocardial infarction (p < 0.01) and those with fixed dilation more frequently suffered cardiac death (p < 0.01) and hospitalization for heart failure (p < 0.01). The group with the highest risk had both a large perfusion defect and cavity dilation. By Cox proportional hazard regression analysis, both transient and fixed LV dilation were strong independent predictors of cardiac events. Transient or fixed LV dilation are commonly seen during dipyridamole Tc-99m sestamibi SPECT imaging (14% incidence for each) and are useful predictors of cardiac events.

Aged

Relation of gender to physician use of test results and to the prognostic value of stress technetium 99m sestamibi myocardial single-photon emission computed tomography scintigraphy.

We analyzed potential gender differences in the use and prognostic value of stress technetium 99m sestamibi tomography, image results, and cardiac event rates over a period of 15 +/- 8 months in 1226 men and 1151 women. Men had more abnormal tomographic images, but referral for catheterization and revascularization similarly increased in relation to the number of defects. Men and women with abnormal images had similar event rates, 19.6% and 18.2%, respectively, although men more often had myocardial infarction or cardiac death (7.6% vs 4.1 %, p < 0.05), whereas women had an increased likelihood of unstable angina or congestive heart failure (11.5% vs 7.6%, p < 0.05). Normal images predicted a low yearly rate of myocardial infarction or death: 1.7% for men and 0.8% for women. Image findings, particularly defect extent, were independent predictors of events in both groups. Thus, after stress Tc-99m sestamibi single-photon emission computed tomography perfusion imaging, there was no gender bias in referral for invasive procedures, and for both men and women image findings were strongly associated with prognostic outcome.

Angina Pectoris

Safety of early intravenous dipyridamole technetium 99m sestamibi SPECT myocardial perfusion imaging after uncomplicated first myocardial infarction. Early Post MI IV Dipyridamole Study (EPIDS).

We assessed the safety of early (2 to 4 days) intravenous dipyridamole infusion in conjunction with technetium 99m sestamibi tomographic myocardial perfusion imaging in patients with first myocardial infarction (MI). Early risk stratification with myocardial perfusion imaging of patients after acute MI may be useful to identify patients who either require further evaluation or may be safely discharged. Because of minimal hemodynamic effects, intravenous dipyridamole may be a safe means of producing hyperemia for myocardial perfusion imaging. Stable patients with first acute MI who met entry criteria were randomized (3:1) to either intravenous dipyridamole infusion (0.56 mg/kg over a 4-minute period) 48 to 96 hours after onset of symptoms or a control (no test) group. Adverse cardiac events (unstable angina, recurrent MI, or cardiac death) were evaluated during and 24 hours after the dipyridamole infusion and during the corresponding 24 hours for the control group. Two hundred eighty-four patients received dipyridamole infusion a mean time of 3.3 +/- 0.7 days after MI. There were no adverse clinical events either during or immediately after the infusion. During the 24 hours after infusion, three patients had symptoms of unstable angina pectoris, one patient had a recurrent MI, and no patients died. The earliest event occurred 4.2 hours after the dipyridamole infusion. Three patients had unstable angina pectoris, whereas no patients had either recurrent MI or died in the control group. There were no statistically significant differences between the two groups. In a multicenter trial, dipyridamole infusion administered early after the first acute MI resulted in no increased evidence of cardiac events either immediately or 24 hours after the procedure compared with a control group. Therefore intravenous dipyridamole can be safely used as a pharmacologic vasodilator for myocardial perfusion imaging soon after uncomplicated MI.

Angina, Unstable

Recent developments in the prognostic use of myocardial perfusion imaging.

Stress myocardial perfusion imaging has become a mainstay in the noninvasive assessment of patients with known or suspected coronary artery disease for several compelling reasons. Radionuclide myocardial perfusion imaging can be performed using a variety of stressors, including exercise, pharmacologic stress (including dipyridamole, adenosine, dobutamine, and arbutamine), or a combination of exercise and pharmacologic stress. The combination of exercise and pharmacologic stress allows an assessment of the patient's exercise tolerance, to be performed while adequately stressing him or her pharmacologically. Radiopharmaceutical choice has been expanded to include not only thallium-201 but also technetium-based imaging agents such as sestamibi and tetrofosmin. The use of technetium imaging agents has recently been enhanced by the ability to assess ventricular function using gated single-photon emission computed tomography (SPECT) imaging techniques. Finally, the ability to provide prognostic information in the same patients has led to incremental clinical use.

Clinical Trials as Topic

Clinical comparison of circular versus noncircular acquisition using technetium-99m myocardial perfusion SPECT imaging.

UNLABELLED: The optimal orbit for myocardial SPECT imaging has not yet been determined. In order to evaluate differences in image quality and reader interpretation between orbiting methods, 50 patients scheduled for routine stress/rest 99mTc-sestamibi imaging had both a circular and a noncircular study using an ADAC Vertex dual-head imaging system. METHODS: Each study was acquired using a 64 x 64 matrix, 64 stops at 25 sec per stop. Images were processed using a Butterworth filter with a frequency cutoff of 0.6 and an order of 5.0. Studies were interpreted by three experienced readers without knowledge of patient name or orbiting technique for normal and abnormal segments and overall image quality. RESULTS: There was no significant difference in the semi-quantitative assessment of either defect extent or reversibility or in the quantitative assessment of defect size between the two types of orbits. However, while all 50 noncircular studies were read as good or fair quality, 23 circular studies were read as fair or poor (p = < 0.0002). CONCLUSION: Qualitative and quantitative analysis revealed similar size and extent of perfusion defects using either circular or noncircular orbit, but images with the noncircular orbit were of significantly better image quality and may be preferable to a circular orbit with 99mTc-sestamibi.

Adrenergic beta-Agonists