Search PubMed⌕ Search

Biomedical subjects

G T Kondos

Publications and source records attributed to G T Kondos.

21 records · Page 2Linked to original sources

Comparative angiographic right and left ventricular volumes.

Comparative angiographic right and left ventricular volumes and right and left ventricular ejection fractions have been reported in the same normal infants and children. This relationship was assessed in adult patients to determine if these pediatric observations persist in later life. Seventeen adults, who had both right and left ventricular angiograms and who had no demonstrable organic heart disease, were studied. Right ventricular end-diastolic volume ranged from 54 to 98 (76 +/- 14, mean +/- SD) cc/m2 and left ventricular end-diastolic volume ranged from 48 to 90 (70 +/- 12) cc/m2; p less than 0.03. Right ventricular end-systolic volume ranged from 22 to 47 (33 +/- 8.0) cc/m2 and left ventricular end-systolic volume ranged from 13 to 34 (22 +/- 5.3) cc/m2; p less than 0.00005. Calculated right ventricular stroke volume ranged from 31 to 60 (43 +/- 8.3) cc/m2 and left ventricular stroke volume ranged from 29 to 70 (48 +/- 11) cc/m2; p = NS. Calculated right ventricular ejection fraction ranged from 0.48 to 0.62 (0.57 +/- 0.04) and the left ventricular ejection fraction ranged from 0.57 to 0.84 (0.68 +/- 0.07; p less than 0.00005. Both right ventricular end-systolic and end-diastolic volumes were greater than left ventricular end-systolic and end-diastolic volumes. This resulted in decreased right ventricular ejection fraction compared to left ventricular ejection fraction. The difference between the two ventricles may be due to compliance, muscle mass, and anatomic configuration with a net result of one chamber more completely emptying than the other. Thus it appears that the relationships between right and left ventricular volumes noted in infancy and childhood persist in adult life.

Adolescent↗

Determination of left ventricular ejection fraction by visual estimation during real-time two-dimensional echocardiography.

It has been shown that the measured reduction in the cross-sectional area of the left ventricle (LV), as viewed in the short axis, closely approximates its ejection fraction (EF). We assessed the reliability of using two-dimensional echocardiography (2DE) to visually estimate the EF during real-time viewing, without the need of digitizers, planimetry, or calculations. Twenty-five adult hospitalized patients with either suspected or known cardiac disease were evaluated prospectively. Each patient also had gated nuclear angiography during the same admission, and 14 had cardiac catheterization with left ventriculography. The EF was determined by 2DE using a visual estimate of the percent area reduction of the LV cavity in the short-axis view at the level of the papillary muscles. All 2 DE studies were read by two or more blinded reviewers, with a value for the EF to the nearest 2.5% determined by consensus. These values correlated closely to the values determined in all 25 patients with gated nuclear angiography (r = 0.927) and the 14 patients who had left ventriculography (r = 0.935). We believe that this method of visually estimating the LVEF will enable echocardiographers to easily use 2 DE for a reliable and instantaneous assessment of ventricular function, without the need of sophisticated analytical equipment.

Adult↗

Quantitative validation of cineangiographic axial oblique biplane left ventricular volume measurement.

Axial oblique left ventriculography allows unique visualization of acquired and congenital cardiac lesions. However, validation of the accuracy of left ventricular (LV) volume with axial oblique projections is limited and clouded by orthogonal violations between biplane projections. Biplane cineradiographic volume measurement of 17 LV casts employing the axial projection 35 degrees right anterior oblique/55 degrees left anterior oblique/30 degrees cranial (35 degrees RAO/55 degrees LAO/30 degrees Cr) was performed and compared to the conventional postero-anterior/lateral (PA/Lat) and 30 degrees right anterior oblique/60 degrees left anterior oblique (30 degrees RAO/60 degrees LAO) views. LV volume was calculated from biplane cineradiograms by area length and Simpson's rule method. True LV volume by water displacement was 33 +/- 28 (mean +/- S.D.), range 15 to 112 ml. LV cast volume calculated by the area length method from cineradiograms was overestimated (p less than 0.002) but no different by Simpson's rule method (pNS). The ideal correlation was best approximated by the 35 degrees RAO/55 degrees LAO/30 degrees Cr biplane view calculated by Simpson's rule, r = 0.99, y = 3.5 + 0.9x, and standard error of estimate (SEE) = 4.3 ml. Biplane LV angiography with the axial projection permitted accurate LV volume measurement, and Simpson's rule provided the best representation of true volume.

Animals↗