Search PubMed⌕ Search

Biomedical subjects

G Slama

Publications and source records attributed to G Slama.

At least 181 records · Page 10Linked to original sources

Intraperitoneal insulin in uraemic diabetics undergoing continuous ambulatory peritoneal dialysis.

The kinetics of absorption of intraperitoneally administered insulin were studied in nine uraemic insulin-dependent diabetics undergoing continuous ambulatory peritoneal dialysis (CAPD). In each of three studies 20 U of regular insulin was directly injected as a bolus into the peritoneal cavity through an indwelling Tenckhoff catheter. In two procedures the insulin injection was followed by the instillation of either 2 litres of 1.5% dextrose dialysates or 2 litres of 4.5% dextrose dialysate. In the third 20 ml of saline was used to flush the tubing. Plasma free insulin values rose more rapidly and reached significantly higher concentrations (55.6 +/- 18.8 mU/l) when the insulin had been injected into an empty peritoneal cavity than when it was followed by dialysate. These differences were observed despite the fact that most of the insulin injected was retained by the patients. Since the plasma insulin values did not differ after instillations of dialysate containing 1.5% and 4.5% dextrose, the osmolality of the dialysate seemed not to affect insulin absorption, and the dilution of the insulin probably delayed its transfer through the peritoneum. These findings suggest that insulin given intraperitoneally to patients undergoing CAPD will be most effective if it is given into an empty peritoneal cavity at least 30 minutes before the dialysate is instilled.

Blood Glucose↗

[Rapid control of glycaemia with reactive sticks. A comparative study of 5 methods (author's transl)].

Self-monitoring of glycaemia is becoming increasingly popular. The authors have tested two sticks, Dextrostix and Haemoglukotest 20-800, and three colorimeters used in conjunction with the sticks, Dextrometer, Hypocount and Glucochek, in a range of blood glucose levels comprised between 0.45 and 2.20 g/l. These methods are reliable but not as accurate as laboratory measurements. However, provided they are not used alone, sticks are accurate enough for the control of glycaemia in diabetic patients. Haemoglukotest 20-800 appears to be the simplest and most precise method. Colorimeters seem to be useful but not indispensable, at least for trained users.

Blood Glucose↗

Correlation between the nature and amount of carbohydrate in meal intake and insulin delivery by the artificial pancreas in 24 insulin-dependent diabetics.

We have studied the effects of mixed meals and dextrose intake on blood glucose and insulin delivery by the artificial pancreas in 24 insulin-dependent diabetics. A group of 12 patients had 3 mixed meals containing at random 20, 40, and 60 g of complex carbohydrate along with protein and fat; another group of 12 diabetics, comparable in weight, age, and duration of diabetes, received at random 20, 40, and 60 g of dextrose. Dextrose ingestion led to a higher initial blood glucose increase than did the mixed meal, but the duration of blood glucose increase lasted significantly longer after the mixed meal than after the dextrose load. The areas under the curves of hyperglycemia were not significantly different. There was a high (but not linear) correlation between the total amount of insulin delivered in order to restore initial blood glucose values and the amount of CHO consumed. There was no correlation with age, body weight, duration of diabetes, nor with the nature and order of administration of the CHO load; 5.1 +/- 1.6 to 13.7 +/- 2.1 units of insulin were needed for a period of 94 +/- 11 to 132 +/- 11 min. It is suggested that some of the data obtained in this study might be useful in the programming of an open-loop insulin infusion system.

Adult↗

[Flat curves of oral glucose tolerance tests (author's transl)].

Patients are often referred to diabetologists on account of a flat curve of oral glucose tolerance test. This abnormality, however, is virtually never associated with a serious metabolic disorder and in any case, it never points to a disease that cannot be diagnosed by questioning or by straightforward clinical examination, nor confirmed by a more specific laboratory test. The curve may be flat for technical reasons (e.g. rejection of the glucose administered, timing of blood withdrawals and assays), for physiological reasons (differences between venous and arteriolo-capillary blood), or for pathological reasons (interaction with drugs, pituitary, thyroid or adrenal insufficiency, digestive malabsorption) but it never implies organic hypoglycaemia nor diabetes mellitus.

Adrenal Insufficiency↗

A sophisticated programmable miniaturised pump for insulin delivery.

We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.

Computers↗

The use of the artificial pancreas in uremic diabetic patients.

Maintenance hemodialysis and renal transplantation are increasingly used for treating diabetic patients with end-stage renal failure. The use of the artificial pancreas is able to prevent large blood glucose fluctuations in these patients with atherosclerosis, advanced retinopathy or neuropathy in which hyper- and hypoglycemia are potentially deleterious. For this purpose, we have developed and are utilizing an artificial pancreas easily utilizable without special training by the staff of a dialysis unit. This artificial pancreas uses a polarographic glucose electrode with a fast response time (45 to 90 seconds), a terminal display for operator communication, and a continuous digital and analogyl display for control of the running operation. There is also a printer to display in tabular and graphical form the values at any time during the operation. In this preliminary study, 7 patients have been studied: five under repetitive hemodialysis for four hours, 3 times a week; one treated by peritoneal dialysis for 12 hours, twice a week and one controlled during, and 48 hours after, renal transplantation. The macroscopic pancreas normalizes blood glucose under these circumstances, helps in a better understanding of blood glucose homeostasis in uremic patients under dialysis, leads to a more precise evaluation of insulin needs, may help to improve the nutritional status of the patients, and has an educational value for the patient and the medical staff.

Artificial Organs↗

Double blind clinical trial of mazindol on weight loss blood glucose, plasma insulin and serum lipids in overweight diabetic patients.

Mazindol, a drug with tricyclic structure unrelated to amphetamine and other anorectic drugs, has been used as an anorectic agent in a double blind clinical trial at a dose of 2 mg/day for 12 week (mazindol v. s. placebo), associated with a 1000 calorie diet on 46 obese diabetic patients. Thirty seven patients completed the trial with no significant difference between the two groups in the drop-out population; mazindol was well tolerated. In the mazindol-treated group the mean weight loss was 13.5 kg (22.3%) which was significantly greater (p less than 0.001) than in the placebo treated group where the mean weight loss was 4.2 kg (9.8%). Comparing the two groups after the 12 week trial, decrease in fasting blood glucose, serum insulin and triglycerides was not significant. In the mazindol-treated group a significant decrease of serum cholesterol, triglycerides and of the mean area under the curve of insulinemia during the OGTT has been observed. In the placebo treated group only serum triglycerides decreased significantly. The variations of plasma insulin and serum cholesterol were found to be correlated to the magnitude of weight loss. In conclusion mazindol is an effective drug for weight loss on the whole well tolerated but without specific properties on metabolism.

Blood Glucose↗