Superficial femoral artery rupture after balloon angioplasty: treatment with implantation of a balloon-expandable endovascular graft.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G S Werner.
Explore the source record for details and available documents.
HISTORY AND CLINICAL FINDINGS: A 72-year old man was admitted because of increasing dyspnoea, failing fitness and weight loss. Physical examination was unremarkable except for decreased heart sounds. INVESTIGATIONS: He was anaemic (haemoglobin 11.7 g/dl), erythrocyte sedimentation rate was raised (80/90 mm) as was C-reactive protein (169 mg/dl). Chest radiogram showed tent-like widening of the cardiac silhouette and a 6 cm space-occupying lesion in the left hilus. Echocardiography revealed pericardial effusion of up to 2.3 cm (epi- to pericardium). TREATMENT AND COURSE: Because of an increase in dyspnoea and pericardial effusion a pericardiocentesis was performed. This fluid and needle biopsy of the space-occupying lesion revealed small-cell carcinoma. 6 days after the pericardiocentesis the dyspnoea further increased as did the pericardial effusion (to 3.9 cm). Percutaneous balloon pericardiotomy was uneventfully performed. During a follow-up period of 14 months there were no further pericardial effusions. CONCLUSION: Percutaneous balloon pericardiotomy can be undertaken as a minimally invasive treatment of symptomatic pericardial effusion. It should be considered as an alternative to surgical creation of a pericardial window, especially in very ill patients.
Transcatheter occlusion of cardiac defects has become an effective and less invasive alternative to open heart surgery. Thromboembolic complications are rare events, after both surgical and transcatheter closure of atrial septal defects [Galal et al.: Eur Heart J 15:1381-1384, 1994]. We report on a case of thrombus formation on the atrial septal defect occluder system (ASDOS) [Sievert et al.: Cathet Cardiovasc Diagn 36:232-240, 1995; Hausdorf et al.: Heart 75:83-88, 1996]. Two days after transcatheter occlusion, the patient suffered an acute stroke due to embolism despite anticoagulation with intravenous heparin. A coagulation disorder with reduced factor XII concentration was deduced as the likely cause. Repeated transesophageal echocardiographic (TEE) studies revealed an involution of the intracardial thrombus within weeks of subsequent anticoagulatory treatment. First off, this case shows that patients with factor XII deficiency are at risk for thromboembolism. Second, it again clarifies that even large amounts of intraartrial thrombotic material may not be seen by transthoracic echocardiography (TTE) and underscores the necessity of performing TEE. Screening patients for coagulation disorders (Quick's value (Q), partial thromboplastin time (PTT)) before they are selected for treatment with thrombogenic devices is indispensable. With regard to their personal history (earlier thromboembolism) and the result of this screening (e.g., prolongation of PTT), quantitative determination of coagulation factors is reasonable. If patients endangered by thromboembolic complications nevertheless undergo ASD occlusion procedures, anticoagulation monitoring requires exceptional attention. Furthermore, it is recommended that TEE should be carried out in these patients 2 days after treatment, since transthoracic echocardiography (TTE) might be unable to detect thrombus formation on the device.
Coronary stenting is the primary therapeutic option for many coronary lesions, after the risk of subacute stent thrombosis and bleeding complications has been reduced by antithrombotic regimens and improved stent expansion. It would be desirable to shorten the procedure and the duration of ischemia, and to reduce the risk of ischemic complications during balloon inflation by implanting the stent without previous dilatation of the lesion. This is not possible with the presently available stent delivery systems. This new therapeutic concept was tested with a specially designed balloon catheter, on which slotted-tube stents can be fixed between two conical radiopaque markers. Sixty-one patients eligible for angioplasty underwent direct stent implantation without predilatation. Four procedures were performed for acute myocardial infarction, and two as high-risk PTCA. Single slotted-tube stents (Palmaz-Schatz, NIR, or JOStent) of 14-16-mm length were mounted between the conical radiopaque markers of a special balloon which provided a fixation for the crimped stent. The direct implantation was successful in 80% of all patients, while in 10% the stent could be deployed after predilatation of the lesion. In 10% of lesions a stent could not be implanted with this and any other delivery system. When patients with successful direct stenting were compared with those with indirect (after predilatation) or unsuccessful stent deployment, the presence of angiographically visible calcification was higher in the unsuccessful cases (75% vs. 19%; P < 0.01), and the patients were older (72+/-8 vs. 61+/-12 years; P < 0.01). Radiation exposure time was only 8.7+/-5.1 min as compared with 12.6+/-7.6 min in conventional stent procedures with predilatation (P < 0.05). The number of balloons used per lesion was also lower than with conventional stenting. Stent dislocation was observed in 5%, and no embolization occurred. The new therapeutic approach of direct stenting without predilatation proved to be a safe and successful procedure in this initial series of coronary angioplasties. When calcified coronary lesions are avoided, it provides a way to rationalize stent implantation with shorter radiation exposure times, fewer balloons, and the potential advantage of fewer ischemic complications as no balloon predilatation is required.
Chronic coronary occlusions carry a high recurrence rate, and coronary stenting evolves as a preferred therapy of these complex lesions. Insight into the morphology of the occluded segment by intracoronary ultrasound may provide information which may help to improve the interventional strategy and the long-term outcome. After successful recanalization of chronic coronary occlusions (4 weeks to 33 months; median 3.2 months) in 59 patients, 29 patients were treated by balloon angioplasty alone, and 30 patients received one or more coronary stents because of complicated dissections or a high-grade residual stenosis after balloon dilatation. Intracoronary ultrasound was used to assess the lesion morphology and to quantify the angioplasty result. The luminal area, the total vessel area and the extent of the plaque burden were measured proximal and distal to the occlusion and at the narrowest site within the occlusion or the coronary stents, and the elastic recoil was calculated. Plaques in chronic occlusions were predominantly hypodense, and 44% were characterized by a multilayered plaque appearance. The elastic recoil was higher in multilayered plaques than in other plaques (46 +/- 19% vs. 34 +/- 15%; p < 0.05). Based on the quantitative ultrasound measurement after the initial balloon dilatation, it appeared that the initial balloon was undersized in 54%. The lumen area in patients with balloon angioplasty alone was increased from 4.02 +/- 1.34 mm2 to 5.49 +/- 1.47 mm2 and in the stented patients from 3.58 +/- 1.04 mm2 to 7.10 +/- 1.92 mm2. The recurrence rate in patients with balloon angioplasty was 48% with 24% reocclusions. Patients with recurrence had a slightly lower lesion area (3.97 +/- 1.41 mm2 vs. 4.71 +/- 1.44 mm2; n.s.) and minimum diameter (1.82 +/- 0.31 mm vs. 2.14 +/- 0.40 mm; p < 0.05) after dilatation. In stented patients the recurrence rate was 27% with two early stent thrombosis (6.7%) and no late reocclusion. In patients with recurrence the achieved stent area was significantly smaller than in those without restenosis (5.71 +/- 0.90 mm2 vs. 7.59 +/- 1.96 mm2; p < 0.01), and the degree of vascular remodelling at the site of the occlusion was less pronounced. Intracoronary ultrasound showed sonographic plaque characteristics in chronic occlusions which responded poorly to balloon dilatation alone. Stent implantation improved considerably the luminal area gain and could reduce the long-term outcome. To further improve the recurrence rate in stents, an optimized stent expansion should be achieved, and intracoronary ultrasound could provide an ideal tool for this purpose.
BACKGROUND: In the era of coronary stenting with high-pressure expansion, stent thrombosis remains a major life-threatening risk. Because of its superior imaging mode, intracoronary ultrasound could provide insight into potential risk factors for stent thrombosis. PATIENTS AND METHODS: In 215 patients with stent implantations controlled by intracoronary ultrasound, four occurrences of subacute stent thrombosis, two complete acute thrombotic occlusions, and four occurrences of incomplete acute thrombosis were observed. All stents were expanded with inflation pressures of at least 14 atm ( 17+/-3 atm). The clinical data and the qualitative and quantitative ultrasound information were compared between stents with thrombosis and stents without thrombosis. The luminal area and the plaque border of the reference segments, and of the smallest and largest site of the stented segment after the initial and final expansion, were measured. RESULTS: Stents in the left anterior descending artery were more often involved in stent thrombosis than other vessels, but the vessel dimensions in this target vessel were smaller than in the right coronary artery. The plaque burden was considerably larger after stent implantation with subsequent thrombosis compared with no thrombosis (74.1+/-8.8% vs 63.6+/-8.0%; p < 0.001), and the stent area was smaller (4.80%+/-1.33 mm2 vs 6.86+/-2.08 mm2; p < 0.01 ). In stents with thrombosis the plaque burden of the stent site with the smallest and largest lumen differed by 15.2%, whereas the difference in plaque burden in stents without thrombosis was 2.7%. Intracoronary ultrasound showed that the best risk predictor of thrombosis was the residual plaque burden of the stented segment (odds ratio 15.7 [confidence interval 2.4 to 104.7]), and a small stent area after implantation (odds ratio 6.8 [confidence interval 1.9 to 24.3]). CONCLUSION: In a multivariate risk analysis plaque burden was the strongest independent risk factor for stent thrombosis. The amount of residual plaque mass around the stent might be a potential trigger for thrombus formation.
Prosthetic valve endocarditis is a serious complication after valve replacement with an incidence of 0.8% for both mechanical and bioprosthetic valves. The new Toronto stentless porcine valve (SPV) for aortic replacement offers promising early results in hemodynamics and a low incidence of valve-related complications. The yearly incidence of bacterial endocarditis was reported to be 1% to 1.5%. Though complications such as a perivalvular abscess or anular dehiscence require immediate surgery, a conservative management of infective endocarditis may be possible in carefully selected cases. This is the case of a patient with late prosthetic valve endocarditis of a Toronto SPV bioprosthesis, who, in spite of large vegetations on all three valve cusps, responded well to conservative treatment. This response was monitored through repeated transesophageal echocardiographic studies (TEE), which documented complete functional recovery of the valve.
AIMS: The aim of this study was to assess the risk of intra-aortic balloon counterpulsation and to identify clinical and procedural variables that would predict complications. METHODS AND RESULTS: We analysed 381 consecutive patients who were treated between 1977 and 1995 at our catheterization laboratory and/or medical intensive care unit. The complications considered relevant were limb ischaemia requiring catheter removal, vascular injury, bleeding requiring transfusion, embolic events, and infection. In eight patients the balloon could not be inserted. The rate of complications for the remaining 373 patients was 12.9%. Between 1977 and 1980, surgical insertion was performed using a 12 French catheter with a complication rate of 30.4% (seven of 23 patients). Percutaneous implantation, performed after 1981, had an overall complication rate of 11.7% (41 of 350 patients). Using thinner catheters for percutaneous placement was associated with a reduction in the rate of complications, from 20.7% (17 of 82 patients) for 12 French catheters to 9.9% (10 of 101 patients) for 10.5 French catheters (P = 0.04), and 8.4% (14 of 167 patients) for 9.5 French catheters (P = 0.006). Multivariate logistic regression analysis identified duration of counterpulsation > 48 h (odds ratio 3.6), catheter size (odds ratio 3.4 for 12 French catheters), peripheral vascular disease (odds ratio 2.7), and shock (odds ratio 2.0) as independent risk factors for counterpulsation-associated complications. When considering 9.5 French catheters only (167 patients, all after 1992), the sole remaining independent risk factor was duration of counterpulsation > 48 h (odds ratio 3.8). Those patients with 9.5 French catheters in whom counterpulsation did not exceed 48 h had a low complication rate of 3.9%. CONCLUSION: The rate of percutaneous intra-aortic balloon counterpulsation complications was thus significantly reduced by employing thinner catheters. It was at an acceptable level for 9.5 French catheters, where a long duration of counterpulsation emerged as the most significant factor associated with complications. Whether using even thinner catheters in combination with a sheathless implantation technique further minimizes the risk of counterpulsation remains to be seen.
BACKGROUND AND OBJECTIVE: Spectroscopic guidance of laser angioplasty has been attempted using a diagnostic He-Cd laser in addition to the therapeutic laser system. This study evaluated a single-laser approach for simultaneous ablation and fluorescence excitation. STUDY DESIGN/MATERIALS AND METHODS: A spectroscopy system was coupled to a clinical XeCl excimer laser. Ablation of 162 human aortic samples in saline and blood with 45 mJ/mm2 per pulse yielded 676 fluorescence spectra validated histologically. The same equipment was used in 16 patients for angioplasty of 18 coronary stenoses applying 500 to 1,725 pulses with 45 to 60 mJ/mm2 under saline flushing. A total of 783 spectra were recorded and validated by intracoronary ultrasound (categories: atheroma, fibrous plaque, calcified lesion). RESULTS: In vitro, 5 types of spectra could be differentiated: (1) atheroma, (2) fibrous plaque, (3) calcified lesion in saline, (4) media, and (5) calcified lesion in blood. Discriminant analysis prospectively classified 576 validation spectra with the following sensitivity and specificity for each type: (1) 83.5 and 97.1%, (2) 85.7 and 96.8% (3) 100 and 98.5%, (4) 98.1 and 99.3%, (5) 98.9 and 100%, respectively. In vivo type 1, 2, 3, and 5 spectra were also observed, but not the media spectrum. The predominant sonographic category also prevailed in spectroscopy. Calcified lesions yielded type 3 and 5 as well as mixed spectra. CONCLUSIONS: Using an excimer laser for angioplasty allows combining ablation and fluorescence excitation without a diagnostic laser. Principal types of atherosclerotic lesions and the media can be differentiated spectroscopically with this approach.
A frequent cause of failure of the recanalization of a total coronary occlusion is a subintimal pathway of the guide wire. Three cases of occluded right coronary arteries are presented in which a distal reentry into the true vessel lumen was achieved. Intravascular ultrasound was used to locate the exit and reentry of the guide wire, and to plan the position of multiple stents for the coverage of this subintimal pathway. In all cases antegrade flow to the distal coronary bed was restored.
The aim of this study was to assess whether active coronary perfusion catheters (APC) can provide a sufficient coronary flow in large caliber vessels during balloon inflation. To prevent myocardial ischemia during PTCA, these APC may be employed. However, it is as yet unknown whether the active flow rate of these devices approaches the flow rate prior to PTCA during balloon inflation. Therefore, we measured the efficacy of the APC during balloon inflation in vessels supplying a large amount of myocardium. In 12 patients (1 female, 11 males, 53 +/- 12.6 yr) with stenosed vessels (average diameter 3.4 +/- 0.26 mm), the coronary flow velocity was measured using a 0.014" Doppler guidewire, which was placed distally bypassing the balloon of the APC. The active perfusion balloon catheter was advanced through a 7F guiding catheter along a 0.014" guidewire. After removal of the guidewire, arterial blood being withdrawn from the side port of the femoral angioplasty sheath was pumped through the catheter to the distal coronary vessel. The perfusion volumes of the pump were set to different levels between 30 to 60 ml/min. Intracoronary flow rate was calculated by the angiographically assessed vessel luminal area [symbol: see text] average peak velocity [symbol: see text] 0.5. The mean coronary flow rate prior to PTCA was 43 +/- 17.7 ml/min. Maximum flow during PTCA was 55 +/- 19.6 ml/min. We found a good correlation between the preset external pump rate and the coronary flow in situ (r = 0.92). Pre-PTCA flow rates were achieved in 11 of 12 patients (92%) during balloon inflation. No relevant decrease in the arterial pressure occurred during dilation times of 4.6 +/- 1.63 min. Only two patients showed significant ECG changes during these balloon inflations. After an average follow-up period of 13 +/- 6.3 mo, only one patient (8%) had a significant re-stenosis requiring the implantation of a stent. The combination of intravascular Doppler velocity measurements with quantitative coronary angiography offers the opportunity of exact online flow registration during angioplasty. Using APC, It is possible to maintain a sufficient coronary flow in the distal vessel during balloon inflation even in large vessels. Therefore, as compared with mechanical circulatory assist devices, coronary assist by APC is a little invasive, but according to our measurements it might be a sufficient tool for performing PTCA also in high-risk patients.
Embolic complications are a major prognostic determinant in the clinical course of infective endocarditis (IE) with an incidence of about 30-50%. In order to analyze risk factors leading to embolism in native (NVE) and prosthetic valve endocarditis (PVE), we reviewed 177 consecutive patients; 43% were female, 57% male, PVE occurred in 24% of all patients all left-sided, among the NVE were 11% right-sided IE. Major embolic complications occurred in 40% of all patients. In NVE, a higher rate of embolic events (45% vs. 26%; p < 0.05), and a larger vegetation size compared to PVE was observed (14 +/- 6 mm vs. 11 +/- 5 mm; p < 0.05). The most important risk factor for embolic complications in NVE was Staphylococcus aureus (odds ratio 6.4). Furthermore, double valve endocarditis, fever, and mitral valve endocarditis were associated with the risk for embolism. In case of severe regurgitation the rate of embolic complications was reduced (54% vs. 77%; p < 0.05). In PVE, fever was a risk factor for embolic events. Staphylococcus aureus was also a frequent microorganism in embolism (45% vs. 22%). The in-hospital mortality was significantly increased in case of embolism (NVE 40% vs. 11%; p < 0.001; PVE 36% vs. 9% p < 0.05). About 50% of all embolic events occurred before admission. In NVE, due to high in-hospital mortality, the rate of patients with embolism undergoing surgery was lower (57% vs. 72%; p < 0.05); whereas in PVE no significant difference was observed. In patients with NVE, aspirin therapy because of coronary artery disease appeared to reduce the rate of embolic complications (11% vs. 47%). However, the low number of patients on aspirin (9%) does not allow recommendations regarding a potential benefit. In conclusion, identification of risk factors leading to embolism in IE may be useful in considering early surgical therapy. However, the high rate of embolic complications before hospital admission indicates a need for improving the diagnostic delay in the prehospital phase.
Coronary angioplasty is gaining increased importance as a primary treatment of acute myocardial infarction, but the complication rate of the procedure is higher than in stable coronary artery disease. In a consecutive series of 110 coronary angioplasties in patients with acute myocardial infarction, the cause of initially failed procedures was studied by intravascular ultrasound. The balloon angioplasty was immediately successful in 66%. In those cases with crossing of the lesion but a dissatisfying dilatation result (persistent occlusion, reocclusion, or dissection) an intravascular ultrasound probe could be advanced to 32 of 34 lesions. The information provided by ultrasound guided the subsequent bailout therapy. Persistent occlusions were caused by extensive thrombosis in 4.5% of all cases, subsequently treated by local thrombolysis for 12 to 16 hours, and in 1.8% by a ruptured plaque, which was treated by stenting. In cases with Thrombolysis in Myocardial Infarction (TIMI) flow II, angiography suggested a thrombus in 9.1%, but intravascular ultrasound could detect dissections instead of a thrombus in half the cases. In cases of dissection, stenting was performed. Dissections were observed by angiography in 15.5%, and all cases were confirmed by ultrasound. In vessels >2.5 mm the dissection was treated by stenting. Overall, in 20 of 21 lesions stents were successfully implanted. No stent thrombosis was observed. With the assistance of intravascular ultrasound during bailout therapy, the success of coronary angioplasty to achieve TIMI flow III without residual stenosis in an unselected consecutive patient cohort with acute myocardial infarction was 96%. In direct angioplasty for acute myocardial infarction the procedure is frequently complicated by events such as plaque rupture and extensive vascular thrombosis, which are uncommon in coronary angioplasty for stable angina. Intravascular ultrasound provided insight into the underlying morphologic characteristics of failed angioplasty that enhanced the information provided by coronary angiography and assisted in the selection of the bailout therapy.
Two strategies to achieve optimal expansion of Wiktor stents in coronary arteries, oversizing at normal balloon pressures (group 1) and high-pressure dilatation (group 2), were compared. We randomly assigned 20 symptomatic patients with de novo coronary artery stenoses of <15 mm length to one of the two treatment groups. Intracoronary ultrasound catheter pull-backs after stent implantation showed incomplete stent attachment with one or two struts protruding into the vessel lumen in 3 of 10 patients in group 1 but in no patient after high-pressure dilatation in group 2 (p<0.01). Recross and high-pressure dilatation of the 3 stents in group 1 achieved complete attachment of all stents. Minimal luminal diameter was comparable between the groups (2.61 +/- 0.34 mm in group 1 after stent delivery, and 2.68 +/- 0.45 mm in group 2 after high-pressure dilatation). Minimal luminal area (expressed as a percentage of the reference cross-sectional area) was slightly but insignificantly greater in the high-pressure group (91.1% +/- 25.6% vs 85.5% +/- 15.1%). We conclude that implantation of Wiktor stents at normal inflation pressures does not reliably result in complete attachment of all struts to the vessel wall.
BACKGROUND: The therapeutic benefit of an angiotensin-converting enzyme (ACE) inhibitor in combination with a different type of vasodilator is unknown. METHODS AND RESULTS: To evaluate the effects of a combined therapy on quality of life, exercise tolerance, and hemodynamic parameters, patients with severe heart failure (New York Heart Association classes III and IV, ejection fraction below 35%) who were on ACE inhibitor therapy were randomly assigned to additional double-blind treatment with urapidil (60-120 mg/d) or placebo for 12 weeks. After enrollment of 36 patients, the study was terminated early because no beneficial effects on exercise tolerance and hemodynamic parameters could be shown for the urapidil treatment, and a trend toward increased mortality of the urapidil group was observed (odds ratio, 4.92 [0.49-49.6]; P = .167). CONCLUSION: The combination of urapidil with an ACE inhibitor in the treatment of severe chronic congestive heart failure does not seem to offer any advantages over therapy with an ACE inhibitor alone and may have potentially harmful effects.
AIMS: Studies by intravascular ultrasound demonstrated inadequate expansion in a large number of stents, which lead to the increase of inflation pressure for stenting. The present study examined whether routine use of high-pressure inflation would be sufficient for an optimum stent expansion without sonographic guidance. METHODS AND RESULTS: Two types of single coronary stents (Palmaz-Schatz in 54, and Wiktor in 25) were implanted with inflation pressures of 16-20 atm in 79 nonocclusive coronary lesions. IVUS before stenting was used in 78% to select the adequate stent size. Intravascular ultrasound after stenting was used to asses the minimum stent are and diameter, the reference areas, and the strut apposition to the vessel wall. The difference between the area of the expanding balloon and the stent area was calculated as the luminal deficit of the stent. Completeness of stent expansion required full strut apposition and lesion coverage, and a minimum stent area that was larger than the distal reference, and larger than 60% of the proximal reference. Intravascular ultrasound before stenting lead to an increase of the stent size in 47%. After high-pressure expansion, even with the optimized balloon size, 8% of stents had struts protruding into the lumen. The stent area (6.87 +/- 1.93 mm2) was significantly smaller than both the proximal (9.59 +/- 2.91 mm2; p < 0.001) and distal reference area (8.23 +/- 3.03 mm2; p < 0.001). The criteria for complete expansion were met in 48%. The expansion with a larger high-pressure balloon in 28 stents lead to an increase of the stent area by 19% (8.19 +/- 2.24; p < 0.001), and full stent apposition in all cases. The criteria of stent expansion were met in 82%. A wide range of the luminal deficit upto 48% was observed, which was not related to sonographic lesion characteristics, except in lesions with complete circumferential calcifications. The different stent designs were characterized by a slightly lower luminal deficit in slotted-tube stents (23 +/- 13% vs. 28 +/- 12%; p = 0.11) and a better index of stent symmetry as compared with the coil stent (0.87 +/- 0.08 vs. 0.82 +/- 0.09; p < 0.05). CONCLUSION: Routine use of high-pressure stent expansion did not lead to a sufficient stent expansion, even when the initial stent size had been guided by intravascular ultrasound. Further stent dilatation with larger balloons under ultrasound guidance would be required to optimize the luminal area gain.
OBJECTIVES: Balloon angioplasty of chronic coronary occlusions has a low procedural success and a high recurrence rate. Better tomographic insights into the lesion morphology may improve the interventional strategy and results. METHODS: Intracoronary ultrasound was used during the recanalizaton procedure of 45 chronic coronary occlusions (2 weeks to 14 months; average 3.4 months) to determine the lesion morphology and to assess the angioplasty result. The luminal area and the plaque burden were measured proximal and distal to the occlusion, and within the occlusion. The ultrasonographic characteristics of the occlusive lesions were compared to 45 nonocclusive lesions of age-matched patients with stable angina pectoris. RESULTS: Occlusive lesions were more often echodense as compared to nonocclusive lesions (35% vs. 20%; p = 0.10). In chronic occlusions a multi-layered plaque morphology was observed in 22%, and this morphology was not found in nonocclusive lesions. Angiographic characteristics were not related to the ultrasonographic morphology of the lesion. Despite similar vessel areas in occlusive and nonocclusive lesions, the balloon size selected according to the angiographic image was underestimated in occlusive lesions. Based on the quantitative ultrasound measurement the balloon size was increased from 2.6 +/- 0.3 mm to 3.3 +/- 0.5 mm in 53% of the lesions. This resulted in an increase of the luminal area from 3.51 +/- 0.92 to 5.08 +/- 1.43 mm2 (p < 0.001). The acute recoil after balloon angioplasty was similar (34 +/- 18%) in hypodense and echodense plaques, but was significantly higher in lesions with a multi-layered plaque morphology (49 +/- 22%; p < 0.05). In 19 patients with severe dissections or extreme acute recoil (residual stenosis > 50%) the use of a stent increased the luminal area from 3.94 +/- 0.81 to 7.51 +/- 1.71 mm2 (p < 0.001). CONCLUSIONS: Intracoronary ultrasound demonstrated a multi-layered plaque morphology in one fourth of the chronic occlusions. This type of plaque was associated with a significant acute recoil. The presence of diffuse atherosclerosis in neighbouring segments of chronic coronary occlusions leads to underestimation of the balloon size. Quantitative assessment by intracoronary ultrasound helped to optimize the balloon size leading to a significant luminal area gain. The detection of excessive acute recoil should be considered an indication for stent deployment.
We describe the clinical course of a 58-year-old man who died from acute papillary muscle rupture as a complication of clostridial sepsis. There was no evidence for myocardial infarction, infective endocarditis, prior chest trauma or other known causes of papillary muscle rupture. Histological specimens taken at autopsy demonstrated clostridial infection of the heart. To our knowledge the occurrence of papillary muscle rupture in the setting of clostridial sepsis has not yet been reported in the literature.