Search PubMed⌕ Search

Biomedical subjects

G S Roubin

Publications and source records attributed to G S Roubin.

At least 55 records · Page 3Linked to original sources

Extracranial vertebral artery stent placement: in-hospital and follow-up results.

OBJECT: The authors summarize their experience with stent deployment in the treatment of vertebrobasilar artery (VBA) insufficiency. This is an underdiagnosed condition, and the incidence of significant vertebral artery (VA) stenosis has been underappreciated. Medical therapy has been the mainstay of treatment because of the high rate of morbidity associated with surgical correction of VA stenosis. Recently, some authors have reported acceptable results with the use of percutaneous transluminal angioplasty, but this technique has significant weaknesses such as elastic recoil and problems in achieving safe treatment of dissections. METHODS: The authors investigated the feasibility, safety, and outcome of VA stent placement in 50 patients in whom 55 vessels were treated using stents. Technical success was achieved in 54 (98%) of 55 vessels, with no procedure-related complications. However, one patient (2%) died of nonneurological causes, and one (2%) suffered a stroke that occurred within the 30-day postprocedural period and was related to a complicated coronary intervention. Clinical follow-up review performed at a mean of 25 +/- 10 months revealed two patients (4%) with recurrence of VBA symptoms. Six-month angiographic follow up was completed in 90% of eligible patients, with a 10% incidence of restenosis as defined by greater than 50% luminal narrowing. CONCLUSIONS: Vertebral artery stent placement is feasible in patients who have significant VA stenosis, with predictably good angiographically demonstrated and clinical results. The 6-month angiographically confirmed restenosis rate appears to be low, as does the clinical recurrence rate. This technique solves the problems of elastic recoil and the treatment of angioplasty-induced dissections. Further prospective comparison with medical preventive strategies is warranted.

Adult↗

A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.

OBJECTIVES: A new percutaneous collagen hemostasis device was compared with conventional compression techniques after diagnostic catheterization and angioplasty. Background. Peripheral vascular complications after diagnostic catheterization or more complex interventional procedures, as well as the discomfort of manual compression and prolonged bed rest, represent significant morbidity for invasive cardiac procedures. METHODS: A prospective, multicenter, randomized trial was designed to compare the hemostasis time in minutes and the incidence of vascular complications in patients receiving a vascular hemostasis device with those undergoing conventional compression techniques. RESULTS: After diagnostic catheterization, hemostasis time was significantly less with the vascular hemostasis device than with conventional manual compression (4.1 +/- 2.8 min [n=90 patients] vs. 17.6 +/- 9.2 min [n= 75], p < 0.0001). This difference was greater in patients undergoing angioplasty and was unrelated to the anticoagulation status (4.3 +/- 3.7 min [n = 71 not receiving the heparin], 7.6 +/- 11.6 min [n= 85 receiving heparin], 33.6 +/- 24.2 min [n= 134 control patients not receiving heparin], p < 0.0001 vs. control patients). The time from the start of the procedure to ambulation was slightly less after diagnostic catheterization in patients treated with the device (13.3 +/- 12.1 hours vs. 19.2 +/- 17.8 hours, p < 0.05). It was also less in patients who underwent angioplasty when the device was used after discontinuation of anticoagulation (23.0 +/- 11.1 hours, without heparin), as compared with control compression techniques (32.7 +/- 18.8 hours, p < 0.0001). Time to ambulation was even shorter (16.1 +/- 11.1 h, p < 0.0001) in patients in whom the device was placed immediately after angioplasty while they were still fully anticoagulated with a prolonged activated clotting time (336 +/- 85 s). There were no major complications (surgery or transfusion) after diagnostic catheterization and a low incidence of major complications in patients who underwent angioplasty (0.7% in control patients, 1.4% with the device without heparin, 1.2% with the device and heparin, p = NS). After angioplasty, there was a trend toward fewer hematomas when the device was used in the absence of heparin (4.2% vs. 9.7% in control patients, p = 0.14). CONCLUSION: A new vascular hemostasis device can significantly reduce the puncture site hemostasis time and the time to ambulation without significantly increasing the risk of peripheral vascular complications The role of this technology in reducing complications, length of hospital stay and cost remains to be determined.

Aged↗

In-hospital and late results of coronary stents versus conventional balloon angioplasty in acute myocardial infarction (GRAMI trial). Gianturco-Roubin in Acute Myocardial Infarction.

One hundred four patients presenting with acute myocardial infarction < 24 hours after onset were randomized to 2 groups: group I (n = 52) was treated with balloon angioplasty followed electively with Gianturco Roubin II stents, and group II was treated with conventional balloon angioplasty alone (n = 52). All lesions were suitable for stenting. Baseline clinical, demographic, and angiographic characteristics were similar in the 2 groups. Procedural success was defined as no laboratory death or emergent coronary bypass, Thrombolysis In Myocardial Infarction (TIMI) trial 2 or 3 flow after the procedure in a culprit vessel, and a residual stenosis < or = 30% for coronary angioplasty and < 20% for stent. Procedural success was 98% in group I versus 94.2% in group II, p = NS. Thirteen patients in group II (25%) had bailout stenting during the initial procedure. Adverse in-hospital events including either death, nonelective coronary bypass, recurrent ischemia, and reinfarction occurred in 3.8% in group I versus 19.2% in group II, p = 0.03. Repeat angiography performed routinely before hospital discharge revealed TIMI 3 flow in the infarct-related artery in 98% in group I versus 83% in group II, p < 0.03. At late follow-up, event-free survival was significantly better in the stent (83%) than in the coronary angioplasty (65%) group (p = 0.002). The procedural in-hospital and late outcomes of this randomized study demonstrate that balloon angioplasty followed electively by coronary stents can be used as the primary modality for patients undergoing coronary interventions for acute myocardial infarction, increasing TIMI 3 flow, reducing in-hospital adverse events, and improving late outcome compared with balloon angioplasty alone.

Adult↗

Elective carotid artery stenting in the presence of contralateral occlusion.

Significant carotid stenosis in the presence of an occluded contralateral artery has a poor prognosis with medical therapy alone. Carotid cross clamping during surgical endarterectomy results in critical flow reductions in patients with inadequate collateral flow, and represents a significant risk for procedural strokes. Carotid stenting is being evaluated as an alternative to endarterectomy. We describe the immediate and late outcome of a series of 26 patients treated with carotid stenting in the presence of contralateral carotid occlusion. The mean age of the patients in this group was 65 +/- 9 years, 23 (89%) were men and 10 (39%) were symptomatic from the vessel treated. The procedural success of carotid stenting in this group of patients was 96%. The mean diameter stenosis was reduced from 76 +/- 15% to 2.8 +/- 5%. There was 1 (3.8%) minor stroke in a patient who developed air embolism during baseline angiography. At late follow-up there was no neurologic event in any patient at a mean of 16 +/- 9.5 months after the procedure. Thus, carotid stenting of lesions with contralateral occlusion can be performed successfully with a low incidence of procedural neurologic complications and late stroke.

Aged↗

Predictors of stroke complicating carotid artery stenting.

BACKGROUND: The evolving technique of carotid stenting is being evaluated as an alternative to endarterectomy. Identification of the factors that predispose a patient to neurological complications would facilitate further refinement of the technique and optimize patient selection. METHODS AND RESULTS: We analyzed the impact of various clinical, morphological, and procedural determinants on the development of procedural strokes in 231 patients who underwent elective (primary) stenting of 271 extracranial carotid arteries. The mean age of the patients was 68.7+/-10 years, 165 (71%) were males, and 139 (60%) had symptoms attributed to the lesion treated. This series represented a high-risk subset with 164 patients (71%) having significant coronary artery disease, 91 (39%) having bilateral disease, and 28 (12%) having contralateral carotid occlusion. Of the treated vessels, 59 (22%) had prior carotid endarterectomy, 66 (24%) had ulcerated plaques, and 87 (32%) had calcified lesions. Only 37 treated vessels (14%) would have been eligible for inclusion in the North American Symptomatic Carotid Endarterectomy Trial (NASCET). There were 17 (6.2%) minor and 2 (0.7%) major strokes during and within 30 days of the procedure. NASCET-eligible patients had a low (2.7%) risk of procedural strokes after carotid stenting. The results of multivariate analysis revealed advanced age (P=.006) and presence of long or multiple stenoses (P=.006) as independent predictors of procedural strokes. CONCLUSIONS: During this procedural developmental phase of carotid stenting, neurological complications were highly dependent on patient selection. Advanced age and long or multiple stenoses were independent predictors of procedural stroke.

Aged↗

Current global status of carotid artery stent placement.

Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

Angioplasty, Balloon↗

Angioplasty of totally occluded old vein grafts with new interventional techniques: a long-term follow-up study.

The long-term patency of saphenous vein graft (SVG) lesions after intervention has been shown to be improved with new interventional techniques such as stents. Long-term outcome of patients undergoing successful angioplasty of totally occluded old SVGs with new devices is unknown. From July 1994 to June 1996, 19 patients with totally occluded old SVGs had successful angioplasty with new interventional techniques. Mean SVG age was 123 +/- 8 mo. Thrombolysis in myocardial infarction trial (TIMI) flow was 0 in all target lesions. TIMI 2 or 3 flow was restored after angioplasty in all patients. Intracoronary urokinase, transluminal extractional atherectomy, and stenting were used in 14, 12, and 6 patients, respectively. There was one in-hospital death due to ongoing myocardial infarction, no recurrent infarction, and no repeat angioplasty or bypass surgery in the hospital. At follow-up of 21 +/- 1 mo, there was one sudden death and one myocardial infarction. Five patients had repeat coronary bypass surgery, and 4 had repeat angioplasty. Thirteen patients remained asymptomatic, and 4 had angina. The long-term outcome of patients who had successful reopening of occluded old SVGs is encouraging in this small sample.

Aged↗

Simultaneous bilateral carotid stenting for restenosis after endarterectomy.

Carotid stenting may offer an alternative to surgery for recurrent carotid artery stenosis following endarterectomy. Five patients successfully underwent percutaneous simultaneous bilateral carotid artery stenting for restenosis after endarterectomy, without complications. Six months of clinical and imaging follow-up showed preserved patency of all vessels treated, with no neurologic events in any of the patients.

Aged↗

Relationship between oversizing of self-expanding stents and late loss index in carotid stenting.

Stenting of the internal carotid artery is facilitated by stenting across the carotid bifurcation and sizing the diameter of a self-expanding stent to the large common carotid segment. This usually results in marked oversizing of the self-expanding stent in the internal carotid segment. This study was done to determine the relationship between stent oversizing and late luminal loss index after stenting of the internal carotid artery. Between September 1995 and March 1997, there were 165 patients (189 vessels) who underwent successful carotid stenting with self-expanding stents. Fifty-nine patients (63 vessels) had six-month follow-up carotid angiograms and on-line quantitative angiographic analysis. The mean reference diameter of the internal carotid arteries was 4.93+/-1.31 mm. Nominal stent size was 5 mm in 4 patients, 6 mm in 6 patients, 8 mm in 106 patients, 10 mm in 77 patients, and 12 mm in 1 patient. The average stent/patient was 1.03+/-0.16. There were three patients who had more than 50% diameter renarrowing at follow-up. The mean late loss index was 0.25+/-0.41. By linear regression analysis, there was no clear linear relationship between stent oversizing and late loss index after stenting (correlation coefficient = -0.21, P = 0.09). When analysis of variance with linear contrast was used to analyze six groups of different stent/artery ratios (from 1.4 to > or = 2), late loss indexes are significantly lower in the groups of high stent/artery ratio than the groups of low stent/artery ratio (P = 0.01). The process of oversizing of self-expanding stents deployed in the internal carotid artery does not appear to be associated with late restenosis and high stent/artery ratio seems to be associated with low late loss index.

Adult↗

Quantitative coronary angiographic and intravascular ultrasound assessment of a new nonarticulated stent: report from the Advanced Cardiovascular Systems MultiLink stent pilot study.

OBJECTIVES: The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and 1-year clinical outcome for the Advanced Cardiovascular Systems (ACS) MultiLink stent. BACKGROUND: Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. METHODS: Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations. Clinical follow-up was obtained at 30 days and 1 year. RESULTS: All 49 patients had successful placement of a MultiLink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction. After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001). Minimal lumen cross-sectional area by IVUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm2, respectively, p < 0.001). However, only 64% of stents achieved a lumen/reference area ratio > or = 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery. CONCLUSIONS: Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices.

Aged↗

Abdominal aortic aneurysm repair via percutaneous endovascular stenting in the swine model.

Abdominal aortic aneurysms (AAAs) are the 13th leading cause of death in the United States. Endovascular stent grafts are currently being investigated in clinical trials as an alternative method for treatment of AAA. Twelve pigs underwent creation of AAA using the abdominus rectus fascia. Postoperatively, all 12 animals underwent angiography, which demonstrated turbulent flow within the created aneurysms. Four of the animals were not stented and served as controls. Eight animals underwent subsequent percutaneous placement of a covered endovascular stent via a right femoral sheath, and the stents were deployed between the renal arteries and the aortic bifurcation. The animals were maintained for 120 days before sacrifice and necropsy. Unstented animals (4) died within 6 days, 3 from rupture. Eight animals underwent endovascular stenting: 5 survived without complications, 3 deaths within 2 days were related to technical complications. The 5 surviving animals were sacrificed at 120 days, and necropsy was conducted with in situ dissections of the aorta and intact stent: 3 experimental animals had correct anatomic positioning of the stent, and 2 had inexact stent placement but survived 120 days with AAA thrombosis. Treatment of AAA in this swine model has been demonstrated via placement of a percutaneous covered stent.

Animals↗

Influence of gender on in-hospital clinical and angiographic outcomes and on one-year follow-up in the New Approaches to Coronary Intervention (NACI) registry.

Higher complication rates and lower success rates for treatment of women compared with men have been reported in prior studies of coronary angioplasty and in most early reports of outcome with new coronary interventional devices. In multivariate analysis this has been attributed largely to older age and other unfavorable clinical characteristics. These results are reflected in the current guidelines for coronary angioplasty. Women in prior studies have also had different distributions of vessel and lesion characteristics, but the influence of these differences on the outcome of new-device interventions have not been adequately evaluated. This article evaluates the influence of gender on clinical and angiographic characteristics, interventional procedure and complications, angiographic success, and clinical outcomes at hospital discharge and 1-year follow-up, as observed in the New Approaches to Coronary Intervention (NACI) registry. The NACI registry methodology has been reported in detail elsewhere in this supplement. This study focuses on the 90% of patients-975 women and 1,880 men-who had planned procedures with a single new device and also had angiographic core laboratory readings. Women compared with men were older, had more recent onset of coronary ischemic pain that was more severe and unstable, and had more frequent histories of other adverse clinical conditions. The distributions of several but not all angiographic characteristics before intervention were considered more favorable to angioplasty outcome in women. Differences were observed in device use and procedure staging. Angiographically determined average gain in lumen diameter after new-device intervention, with or without balloon angioplasty, was significantly less in women (1.38 mm) than in men (1.53 mm; p < 0.001); this 0.15 mm difference is consistent with the 0.16-mm smaller reference vessel lumen diameter of women. However, final percent diameter stenoses and TIMI flow and lesion compliance characteristics were similar. Among procedural complications, only treatment for hypotension, blood transfusion, and vascular repair occurred more often in women. More women than men were clinically unstable (2.1% vs 1.1%) or went directly to emergent coronary artery bypass graft surgery (CABG; 1.2% vs 0.6%) on leaving the interventional laboratory. However, in-hospital death (1.4% vs 1.1%), Q-wave myocardial infarction (MI) (0.9% vs 1.1%), and emergent CABG (1.5% vs 1.0%, for women and men, respectively) were not significantly different. Nonemergent CABG was more frequent in women (1.8% vs 0.9%; p < 0.05) and length of hospital stay after device intervention was longer (4.4 days vs 3.8 days in men; p < 0.01). In both univariate and multivariate analyses gender did not emerge as a significant variable in relation to the combined endpoint, death, Q-wave MI, or emergent CABG at hospital discharge. At 1-year follow-up more women than men reported improvement in angina (70% vs 62%) and fewer women than men had had repeat revascularization (32% vs 36%). Similar proportions were alive and free of angina, Q-wave MI and repeat revascularization (46% of women vs 45% of men). Although several procedure-related complications were more frequent in women than men after coronary interventions with new devices, no important disadvantages were observed for women in the rates of major clinical events at hospital discharge and at 1-year clinical follow-up. Additional studies are needed to evaluate the complex interplay of clinical, vessel, and lesion characteristics on success and complications of specific interventional techniques and to determine whether gender, per se, is a risk factor and whether gender specific interventional strategies may be beneficial.

Aged↗

Directional coronary atherectomy (DCA): a report from the New Approaches to Coronary Intervention (NACI) registry.

Directional coronary atherectomy (DCA) with the Simpson coronary atherocath seeks to debulk rather than simply displace obstructive tissue and is a means of enlarging the stenotic coronary lumen. This report from the New Approaches to Coronary Intervention (NACI) registry describes the experience of 1,196 patients who underwent DCA as the sole treatment for either native vessel or vein graft lesions. Device success (post-DCA residual stenosis <50% and > or =20% improvement) was achieved in 87.8%, with a lesion success rate (postprocedural residual stenosis <50% and > or =20% improvement) of 94.0%. The mean resultant stenosis after all interventions (by core laboratory) was 19%. Significant in-hospital complications occurred in 2.8% of patients with DCA attempts, including death 0.6%, Q-wave myocardial infarction (MI) 1.5%, and emergent coronary artery bypass graft surgery (CABG) 2.8%. At 1-year follow-up, cumulative mortality was 3.6%, with repeat revascularization in 28% (repeat percutaneous transluminal coronary angioplasty, 20.1%; CABG, 10.6%). This reflected percutaneous or surgical revascularization of the original lesion (target lesion revascularization) in 22.6% of patients. Subgroup analysis showed a lower lesion success rate and an increased complication rate for unplanned use, vein graft treatment, and treatment of a de novo (vs a restenotic) lesion. Multivariate analysis shows that diabetes mellitus, unstable angina, treatment of a restenotic lesion, and greater residual stenosis after the initial procedure were independent predictors of the composite endpoint of death/Q-wave MI/target lesion revascularization by 1-year follow-up. Among these generally favorable acute and 1-year results, the NACI directional atherectomy data confirm the "bigger is better" hypothesis: that lesions with a lower residual stenosis after a successful procedure had significantly fewer target lesion revascularizations between 30 days and 1 year, with no increase in major adverse events.

Atherectomy, Coronary↗

The use of the Gianturco-Roubin intracoronary stent: the New Approaches to Coronary Intervention (NACI) registry experience.

The objective of this study is to compare the in-hospital and follow-up outcome in patients receiving the Gianturco-Roubin stent (GRS) who were enrolled in the New Approaches to Coronary Intervention (NACI) registry. The GRS was approved by the US Food and Drug Administration (FDA) in August 1992 for the treatment of acute or threatened closure after a percutaneous intervention. The application of intracoronary stenting has broadened substantially in the last few years, but less is known about the use of this device for other indications. Since the NACI registry includes patients stented for other indications, a comparison of these groups with patients being stented for acute or threatened closure was undertaken. A GRS was deployed in 497 NACI registry patients. Of these, 466 patients received a GRS in 1 of 3 of the following ways: (1) 351 unplanned stenting after conventional angioplasty of the same lesion; (2) 54 after failed/suboptimal use of a new device in the same lesion; and (3) 61 in planned stenting procedures. This analysis focuses on these 3 patient subgroups and compares their in-hospital outcome and subsequent follow-up to 1 year. There were 520 stented segments in the 466 patients. The group with stenting after failed/suboptimal new-device use had a higher incidence of myocardial infarction (MI) and cardiogenic shock than either the patients with unplanned stenting after percutaneous transluminal coronary angioplasty (PTCA) or planned stenting (MI 22.2% vs 12.0% vs 0%, respectively, and cardiogenic shock 5.6% vs 0.9% vs 0%, respectively; p < 0.05). This group also had significantly lower procedural success (58.7% vs 75.3% vs 81.5%, respectively; p < 0.05). Although not statistically significant, the requirement for transfusion was higher in the unplanned and new-device stented groups than in the planned group (10.5% vs 16.7% vs 1.6%, respectively). Likewise, the incidence of Q-wave MI was higher in the new-device group (22.2% vs 12% vs 0%, respectively; p < 0.05). Despite a higher, in-hospital complication rate in the unplanned groups, follow-up from discharge to 1 year showed similar outcome. In particular, percutaneous reintervention of the stented segment occurred in: 13.0% in the unplanned after new device; 17.4% in the unplanned after PTCA; and 26.2% in the planned group. Although not statistically significant, the higher incidence of percutaneous target lesion revascularization in the planned group probably represents the greater incidence of restenotic lesions in this cohort. In this very heterogeneous group of patients, including those with failure of another new device, the use of the GRS is associated with acceptable in-hospital and follow-up complication rates, although complications were clearly greater when unplanned use of the stent was needed, particularly after failure of another new device. Although the experience is small, patients having the GRS placed in an elective fashion, i.e., the planned group, appear to experience lower in-hospital complication rates, although they have a higher rate of subsequent target lesion revascularization, in this group of predominantly restenotic lesions.

Aged↗

Excimer laser coronary angioplasty: the New Approaches to Coronary Intervention (NACI) experience.

In the New Approaches to Coronary Intervention (NACI) registry, 887 patients were electively treated with excimer laser coronary angioplasty (ELCA) for coronary artery disease. The Advanced Interventional System (AIS) system was used in 487 cases; the Spectranetics system, in 400. The mean age was 63.4 years. Most patients had unstable angina (60.3%); 43.7% had a prior myocardial infarction; and 18.6% were high risk or inoperable patients. Mean ejection fraction was 55.4%. A total of 1,000 lesions were treated in the 887 patients. Of the 1,000 lesions treated with ELCA in the 887 patients, 36% were in the right coronary artery; 33%, left anterior descending; 13%, circumflex; 3%, left main; and 16.6%, vein graft. By angiographic core laboratory analysis available for 752 (85%) patients with 839 lesions, lesions were 12.76 mm long. The minimum lumen diameter increased to 1.29 mm after the laser and finally to 1.95 mm after adjunctive percutaneous transluminal coronary angioplasty (PTCA) (which was performed in 93% of all lesions), with a final residual stenosis of 32.1% and Thrombolysis in Myocardial Infarction (TIMI) grade 3 flow in 95%. Dissections of grades B, C, or D were seen after 22.0% of initial laser attempts, and postlaser perforations were noted in 2.6%. Additional such dissections accumulated after adjunctive PTCA but the perforation rate remained low. Procedural success was achieved in 84% of patients, but 1.2% died, 0.7% experienced Q-wave myocardial infarction (MI), and 2.7% required emergency bypass surgery. Multiple logistic regression analysis could not identify any independent predictors of these in-hospital complications. One-year mortality was 5.7% and the cumulative incidence of Q-wave MI was 1.5%. Coronary artery bypass graft (CABG) surgery was performed in 15.0% of patients whereas 25.5% required repeat percutaneous intervention with a target lesion revascularization rate of 31%. Independent predictors of death, Q-wave MI, or target lesion revascularization (which, combined, occurred in 35.6% of patients) were the absence of prior MI, ELCA in the circumflex, perforation after the procedure, and small (<2 mm) final minimal lumen diameter. Considering the large number of patients with high-risk lesions, laser angioplasty was performed with excellent procedural success rates and a reasonable incidence of major complications.

Aged↗

Local delivery of ethanol inhibits intimal hyperplasia in pig coronary arteries after balloon injury.

BACKGROUND: Smooth muscle cell (SMC) hyperplasia is an important mechanism of restenosis after coronary angioplasty and the primary mechanism of restenosis within coronary stents. Ethanol has been shown to reduce the response of SMCs to local growth stimulants in vitro. This study was carried out to determine whether local delivery of ethanol solution could reduce intimal hyperplasia induced by balloon injury. METHODS AND RESULTS: Three groups of juvenile domestic pigs underwent oversized balloon dilation injury of the left anterior descending and left circumflex coronary arteries. Immediately after the balloon injury, one of the arteries was randomized to local delivery of 15% ethanol with a local delivery balloon catheter, and the other received no further treatment. Histological and morphometric studies were carried out at 2 weeks in group 1 (n=16) and at 4 weeks in group 2 (n=10). In the third group (n=15), animals were killed at days 4, 8, and 14 after balloon injury, and coronary artery segments were studied by immunohistochemical staining against proliferating cell nuclear antigen (PCNA) and bromodeoxyuridine (BrdU). Histological injury scores were not different between the ethanol-treated and untreated arterial segments in either group 1 or 2. The neointimal areas were significantly smaller in the ethanol-treated arterial segments than in the untreated segments (0.25+/-0.08 versus 0.57+/-0.08 mm2, P=.004, at 2 weeks; 0.33+/-0.05 versus 0.54+/-0.07 mm2, P=.03, at 4 weeks). SMC proliferative activity was significantly lower in ethanol-treated arteries than in untreated arteries at 4 and 8 days after injury by BrdU and PCNA staining. CONCLUSIONS: Local delivery of 15% ethanol solution to pig coronary arteries significantly decreased the SMC proliferative activity and neointimal formation induced by balloon dilation injury.

Angioplasty, Balloon↗