Comparative levels and types of microbial contamination detected in industrial clean rooms.

The primary objective of this study was to determine quantitatively and qualitatively the predominant types of microbial contamination occurring in conventional and laminar flow clean rooms. One horizontal laminar flow, three conventional industrial clean rooms, and three open factory areas were selected for microbiological tests. The results showed that as the environment and personnel of a clean room were controlled in a more positive manner with respect to the reduction of particulate contamination, the levels of airborne and surface microbial contaminants were reduced accordingly. The chief sources of microbial contamination were associated with the density and activity of clean room personnel. In addition, the majority of microorganisms isolated from the intramural air by air samplers were those indigenous to humans. Studies on the fallout and accumulation of airborne microorganisms on stainless-steel surfaces showed that, although there were no significant differences in the levels of microbial contamination among the conventional clean rooms, the type of microorganism detected on stainless-steel surfaces was consistently and significantly different. In addition, the "plateau phenomenon" occurred in all environments studied. It was concluded that the stainless-steel strip method for detecting microbial accumulation on surfaces is efficient and sensitive in ultra-clean environments and is the most reliable and practical method for monitoring microbial contamination in future class 100 clean rooms to be used for the assembly of spacecraft which will be sterilized.

Air Microbiology↗

Effect of chemical germicides on the integrity of hemodialyzer membranes.

Epidemiologic investigations of bacteremia in dialysis patients by the Centers for Disease Control (CDC) identified an association with the use of dialyzers disinfected with a specific chemical germicide. A collaborative study by the CDC and the Food and Drug Administration (FDA) was conducted to determine the effect of dialyzer disinfectants on five types of dialyzer membranes: three cellulosic (Cuprophan, cellulose acetate, cuprammonium rayon); and two synthetic (polysulfone, polyacrylonitrile). The disinfectants tested were: 4% formaldehyde; Renalin; Cidex Dialyzer; Sporicidin HO; Warexin; and RenNew-D. Water was the control. Dialyzers were reprocessed up to 15 times. Each reprocessing consisted of rinsing, air-leak testing, filling with fresh disinfectant, and storing for 2 to 4 days. After 15 reprocessings or air-leak failure, each dialyzer was microbiologically challenged for membrane integrity. Membranes exposed to Renalin, Cidex Dialyzer, and water passed all tests. Cellulosic membranes exposed to Warexin failed all tests after 2 to 9 reprocessings. Cellulose acetate membranes exposed to Sporicidin HD failed microbiologic testing. One polysulfone dialyzer exposed to RenNew-D and one exposed to 4% formaldehyde failed microbiologic testing. These results and those obtained from epidemiologic studies suggest that membrane integrity testing (e.g. an air-leak test) should be an integral part of dialyzer reprocessing.

Biocompatible Materials↗