Measurement of beam current and evaluation of scatter production in an 18-MeV accelerator.

Measurements of dose rate in a 10-MV x-ray beam may indicate considerable variation with collimator setting. This variation is observed even when the peak scatter factor is fixed by holding the field size at the phantom surface constant. The resulting output factor variation may be due to radiation backscattered from the collimators into the monitor chamber. Measurements of charge deposited in the accelerator target were compared with ionization readings for several field sizes. Evaluation of the data indicates that radiation backscattered into the monitor chamber contributes only a small amount to the output factor.

Humans↗

Assessment of the accuracy of stereotactic radiosurgery using Fricke-infused gels and MRI.

The treatment plans for stereotactic radiosurgery employ small, circular, noncoplanar fields applied in a series of arcs, or with synchronous rotation of the accelerator gantry and patient support assembly. Primary or metastatic brain tumors and arterial-venous malformations are localized in relation to a stereotactic head frame using CT, MRI, and angiography. As x-ray doses in the range of 20-40 Gy are delivered in a single treatment, it is critical that the dose distribution produced by the accelerator accurately reflect the one developed by the treatment planning computer. Until the advent of Fricke-infused gels, whose NMR characteristics are changed by irradiation, there was no practical method for assessing the accuracy of x-ray beam positioning on a target that was localized by both CT and MRI. A stereotactic head frame was attached to a hollow glass head filled with a Fricke-infused gel. A 2-mm target point at approximately the center of this manikin was localized by CT and MRI. The head frame was then mounted to the patient support assembly of a linear accelerator, and given a dose of 40 Gy to the isocenter from 6-MV x rays using a modified version of the dynamic stereotactic radiosurgery plan developed in Montreal. Subsequent MRI showed the target point at the center of the dose distribution, thus confirming the accuracy of the stereotactic radiosurgery procedure. This demonstrated the unique characteristics of the Fricke-infused gel for the simultaneous localization of x-ray beams in three dimensions.

Gels↗

Reproduction of radiologic images on plain paper.

Skyrocketing health care costs and pressures from managed care have combined to promote cost-cutting strategies in radiology and radiation oncology departments. A study was conducted to evaluate the use of a high-resolution laser printer for printing plain-paper images as substitutes for both original and duplicate radiologic film images. A variety of radiologic images were used to evaluate the image reproduction capabilities of the printer in terms of linearity, detail, and contrast. In many cases, printed images had a quality comparable to that of the original images. Six computed tomographic (CT) scans and six radiation therapy simulator radiographs were compared with printed reproductions by each of seven board-certified radiation oncologists, who rated the reproductions as acceptable for documentation, acceptable for diagnostic purposes (CT scans only), or unacceptable. Ninety-five percent of printed CT images and 90% of printed simulation images were rated acceptable for documentation. The quality of printed images of radiation therapy port films was not quantitatively measured but was improved by adjusting image contrast and brightness and using various image enhancement techniques. The use of printed images is less expensive than that of processed film and eliminates the environmental, time, storage, and delivery problems associated with film. Technologic advances in imaging, networking, and printing have made possible the inexpensive duplication of medical images.

Copying Processes↗