Computer-controlled instrument system for sequential chemical testing III. Application to liver assessment.

We used the previously described [Clin. Chem. 19, 1114 (1973)] and evaluated [Clin. Chem. 19, 1122 (1973)] computer-controlled instrument system for sequential chemical testing to select and perform tests of hepatic status, to aid the clinician in the diagnosis of liver disease. Results for total bilirubin, aspartate aminotransferase, and alkaline phosphatase obtained from the continuous-flow analysis (SMA 12/60) admission screen were used by the instrument system to determine selectively the values for gamma-glutamyltransferase, alanine aminotransferase, creatine kinase, and total and direct bilirubin. Kit methods for the latter four tests were evaluated on the system; results were similar to manual procedures. A software, enzymatic ratemeter was found to be better than the previously described hardware ratemeter. The follow-up tests of serum prescribed by the system are compared to clinician-prescribed follow-up tests and discharge diagnoses. In 10 of 19 cases, the system and clinician ordered similar follow-up tests; in three cases follow-up differed, and in six cases, the system ordered follow-up tests and the clinician ordered none.

Adult↗

Computer-assisted differential diagnosis of laboratory abnormalities and follow-up testing. Evaluation of the accuracy of a computer program.

An evaluation is made of a computer program which generates a differential diagnostic list given a set of input data obtained from an admission chemistry screening profile. The program is tested by supplying input data on patients for whom diseases are known. The laboratory data from 367 patients are examined. Accurate computer diagnosis is obtained in many disease categories. The original computer program is modified to suggest the follow-up tests indicated based on the diagnoses it makes. By using this program and some additional clinical input from the physician, the clinical pathologist can select the most appropriate computer diagnosis and begin the follow-up testing. Accelerated diagnosis and patient care should result.

Aged↗

A versatile temperature-controlled reaction cuvet.

A thermostatted reaction cuvet, operating under computerized or manual temperature control in the ultraviolet or visible region, is described and evaluated. The cell was designed for use with the automated chemistry system described earlier [Clin. Chem. 19, 1114 (1973)], but can readily be adapted for other applications. The entire 3-ml cuvet assembly warms from ambient temperature to 37 degrees C in less than 10 min, with plus or minus 0.15 degrees C stability; the long-term stability is plus or minus 0.05 degrees C; temperature recovery time after washing or reagent addition is less than 3 min. The optical pathlength is 10.00 mm and the carryover volume is 18 mu-l.

Alanine Transaminase↗

Trend detection in control data: optimization and interpretation of Trigg's technique for trend analysis.

A method for trend detection, Trigg's technique [Oper. Res. Q. 15, 271 (1964)], has been investigated for use in monitoring trends in control data produced by multitest continuous-flow analyzers. Simulated trend data were used to optimize the method. Actual control data were analyzed retrospectively to determine the frequency of trends and the accuracy of several parameters obtained from Trigg's method. The prospective use of the technique has successfully uncovered important trends. Criteria for the interpretation of the Trigg's trend data are suggested and an algorithm for the computer implementation of Trigg's calculations is included.

Autoanalysis↗

Identifying variables associated with inaccurate self-monitoring of blood glucose: proposed guidelines to improve accuracy.

PURPOSE: This study was conducted to evaluate patients' proficiency in self-monitoring of blood glucose (SMBG). METHODS: Diabetes nurse educators in 4 suburban Minneapolis clinic sites surveyed the SMBG training/cure practices of 280 patients with type 1 and type 2 diabetes. Participant SMBG technique was measured by direct observation. Participants performed a finger puncture and used their own meters to measure the first blood sample. A second sample was measured on the HemoCue B Glucose analyzer, and a third sample was used to measure hemoglobin. The series of tests were then repeated. If either of the 2 glucose tests was more than 15% from the HemoCue value, participants were reeducated about the manufacturer's suggested procedure. RESULTS: Of the 280 participants, 19% had blood glucose test results greater than the 15% limit for meter accuracy. After reeducation, 69% of those who had initially failed achieved acceptable results. The most significant problems were lack of periodic meter technique evaluation, difficulty using wipe meters, incorrect use of control solutions, lack of hand washing even when observed, and unclean meters. CONCLUSIONS: As a result of the study, guidelines were subsequently developed to evaluate meter accuracy in an outpatient setting. Further effort is needed to establish standards for evaluating SMBG.

Algorithms↗