Search PubMed⌕ Search

Biomedical subjects

G Pardi

Publications and source records attributed to G Pardi.

At least 37 records · Page 2Linked to original sources

Identifying the indications for laparoscopically assisted vaginal hysterectomy: a prospective, randomised comparison with abdominal hysterectomy in patients with symptomatic uterine fibroids.

OBJECTIVE: To compare laparoscopically assisted vaginal hysterectomy (LAVH) and total abdominal hysterectomy (TAH) in patients with uterine fibroids. DESIGN: A prospective randomised study. SETTING: The San Paolo Hospital, Milan. POPULATION: Sixty-two patients, who were not suitable for a vaginal hysterectomy, requiring treatment for uterine fibroids. METHODS: Randomisation between LAVH and TAH. Comparison of outcomes on the whole series, patients with uteri < or = 500 g (Group 1) and patients with uteri > 500 g (Group 2). MAIN OUTCOME MEASURES: To establish operating time, blood loss, complications, febrile morbidity, analgesics administration and hospital stay for both treatment approaches. RESULTS: Median uterine weight was 400 g in both LAVH and TAH group. Median operating time was longer for LAVH (135 min compared with 120 min for TAH; P = 0.001), but patients undergoing LAVH had less analgesics administration (23% compared with 77%, P < 0.001) and a shorter median hospital stay (3.8 compared with 5.8 days; P < 0.001). LAVH, when compared with TAH in the two weight subgroups, required a significantly longer operating time only in Group 2, significantly reduced analgesics administration only in Group 1, and significantly reduced hospital stay in both groups. Conversions of LAVH to laparotomy were significantly more frequent in Group 2 (3/11) than in Group 1 (0/20) (P = 0.04). CONCLUSIONS: Compared with TAH, LAVH has advantages in removing uteri weighing < or = 500 g, with comparable operating time, less post-operative pain and shorter recovery. Among uteri weighing > 500 g LAVH showed a shorter recovery, but longer operating time than TAH and a 27% rate of conversion to laparotomy.

Adult↗

Fetal plasma leptin concentrations: relationship with different intrauterine growth patterns from 19 weeks to term.

The relationship between in utero fetal growth and fetal leptin concentrations was investigated between 19 and 41 wk in 40 normal (appropriate for gestational age, AGA) fetuses, in 25 intrauterine growth-restricted (IUGR) fetuses, and in 18 fetuses from gestational diabetic mothers (GDM), representing different intrauterine growth patterns. Umbilical venous plasma leptin concentrations were determined at the time of either in utero fetal blood sampling or delivery. Plasma leptin was measurable as early as 19 wk of gestation. A significant difference was observed between umbilical venous and arterial plasma leptin concentrations (0.6+/-0.6 ng/mL; p<0.01). In AGA and in IUGR fetuses, significant positive relationships were found between fetal leptin concentrations and both gestational age (p<0.001) and fetal weight (p<0.001). Leptin concentrations were significantly higher in AGA than IUGR only after 34 wk (p<0.05), but leptin per kilogram fetal weight (leptin/kg) was not significantly different. In IUGR with abnormal umbilical arterial Doppler velocimetry and fetal heart rate, leptin/kg significantly higher than in IUGR with normal biophysical and biochemical parameters was found (p<0.05). Both circulating plasma leptin and leptin/kg were significantly higher in GDM than in normal fetuses (p<0.001) and correlated with abdominal fat mass measured by ultrasound. No gender differences were observed in any group of fetuses. These findings indicate a clear relationship between fetal leptin concentrations and fetal fat mass. Data in severe IUGR suggest the presence of increased leptin concentrations associated with in utero signs of fetal distress.

Diabetes, Gestational↗

Sonographic measurements of subcutaneous fetal fat in pregnancies complicated by gestational diabetes and in normal pregnancies.

AIM: To compare sonographic measurements of fetal fat tissue in pregnancies complicated by gestational diabetes (GD), with patients undergoing either a diet only or a combined diet and insulin treatment, to those obtained in pregnancies with a normal glucose challenge test. METHODS: Forty-five singleton pregnancies complicated by GD but free of any other maternal disease known to affect fetal growth were recruited. GD was diagnosed by a 3-hour OGTT, and treatment was differentiated according to the glycemic profile. GD mothers were divided into two treatment groups: glycemic profile normalized by diet only treatment (n=16) and by combined diet and insulin treatment (n=29). Fetal biometry and subcutaneous fat tissue thickness of the anterior abdominal wall were sonographically evaluated at the time of diagnosis and every 4 weeks afterwards in both GD and normal glucose challenge test group (n=25). RESULTS: No differences were found in neonatal outcomes between combined diet and insulin treatment group and normal cases, whereas neonatal weight showed a statistically significant difference between diet only treatment group and healthy population. Abdominal circumference in fetuses from GD mothers and normal fetuses was similar, but there was a difference in the fetal fat tissue thickness at the time of diagnosis. CONCLUSION: Increased fetal fat tissue thickness in GD mothers at recruitment and its growth rate reduction during adequate treatment may be a new criterion for direct estimation of fetal metabolic status instead of the traditional indirect evaluation based on maternal glucose concentrations.

Adipose Tissue↗

Relationship of umbilical vein blood flow to growth parameters in the human fetus.

OBJECTIVE: Our purposes were to determine the relationship of the growth of umbilical blood flow to growth in body measurements of human fetuses in uncomplicated pregnancies. The study also aimed to assess the relative contributions of growth in umbilical vein diameter and of increased velocity to the increase in umbilical blood flow. STUDY DESIGN: An animal study was conducted to assess the accuracy of umbilical vein blood flow measurements obtained by triplex mode ultrasonography. Seven pregnant ewes underwent triplex mode umbilical vein flow determination. These results were compared with historical flow data obtained by a steady-state diffusion technique in 34 ewes matched for gestational age and weight. In a separate study performed on human beings, reproducibility and precision of triplex mode flow determination were assessed, as were the relationships between umbilical vein flow and gestational age and head and abdominal circumferences. This cross-sectional study was performed with 70 healthy fetuses ranging from 20 weeks' gestation to term. Best-fit interpolating equations and confidence limits were calculated for blood flow measurements versus gestational age and head and abdominal circumferences. RESULTS: In the validation study performed on sheep there were no significant differences between triplex mode and steady-state measurement groups with respect to gestational age or weight. The umbilical vein flows were similar between triplex mode and steady-state measurement groups (P =.881). In the human study the intraobserver and interobserver coefficients of variation for the vein diameter, mean velocity, and absolute umbilical vein blood flow varied from 2.9% to 12.7%. The mean duration of examination was 3 +/- 1 minutes. The umbilical vein diameter and mean velocity increased throughout pregnancy. The absolute umbilical vein flow increased exponentially from 97.3 mL/min at midgestation to 529.1 mL/min at 38 weeks' gestation, whereas umbilical vein flow per kilogram of fetal weight did not change significantly with gestational age. There was a strong correlation between absolute umbilical vein flow and the fetal head and abdominal circumferences. CONCLUSIONS: The triplex mode ultrasonographic technique can play an innovative role in obtaining quick and reproducible measurements of umbilical vein blood flow. The approach was validated with a sheep model. Umbilical vein blood normalized for fetal weight (milliliters per minute per kilogram of fetal weight) and absolute flow (in milliliters per minute) are consistent with previous human studies. We have established new reference values of umbilical vein blood flow relative to head and abdominal circumferences. The growth of umbilical venous diameter accounted for most of the growth in umbilical vein flow.

Animals↗

Umbilical amino acid uptake at increasing maternal amino acid concentrations: effect of a maternal amino acid infusate.

OBJECTIVE: Our purpose was to establish whether, in normal human pregnancies, the maternal intravenous infusion of amino acids can increase fetal amino acid uptake and amino acid concentrations. STUDY DESIGN: Twenty-six normal pregnancies were studied at the time of cesarean delivery (38-40 weeks' gestation). In 10 cases an amino acid formulation (Freamine 8.5% III, Baxter) was infused into a maternal vein before cesarean delivery. Maternal blood samples were obtained during the course of the study. Umbilical venous and arterial samples were obtained from the clamped segment of the cord. There were no differences between the 2 groups for fetal and placental weights and for fetal oxygenation and acid-base balance. RESULTS: Maternal amino acid concentrations increased significantly in the group receiving infusions. Significant increases in umbilical venous concentrations were observed for most amino acids, except for histidine and threonine. The amino acid umbilical arteriovenous differences per mole of oxygen (AA/O(2) ratio) increased significantly for leucine, isoleucine, valine, methionine, phenylalanine, arginine, glycine, serine, alanine, and proline. There were no significant increases for lysine, histidine, and threonine. CONCLUSION: An increase in maternal concentrations leads to an increase in the delivery of most amino acids to the fetus.

Adult↗

Congenital malformations due to antiepileptic drugs.

To identify the major risk factors for the increased incidence of congenital malformations in offspring of mothers being treated for epilepsy with antiepileptic drugs (AEDs) during pregnancy and, to determine the relative teratogenic risk of AEDs, we prospectively analyzed 983 offspring born in Japan, Italy, and Canada. The incidence of congenital malformations in offspring without drug exposure was 3.1%, versus an incidence with drug exposure of 9.0%. The highest incidence in offspring exposed to a single AED occurred with primidone (PRM; 14.3%), which was followed by valproate (VPA; 11.1%), phenytoin (PHT; 9.1%), carbamazepine (CBZ; 5.7%), and phenobarbital (PB; 5.1%). The VPA dose and level positively correlated with the incidence of malformations. This study first determined a cut-off value of VPA dose and level at 1000 mg/day and 70 microg/ml, respectively, to avoid the occurrence of malformations. The incidence of malformations increases as the number of drugs increases, and as the total daily dose increases. Specific combinations of AEDs such as VPA + CBZ and PHT + PRM + PB produced a higher incidence of congenital malformations. The incidence of malformations was not associated with any background factors studied except for the presence of malformations in siblings. These results indicate that the increased incidence of congenital malformations was caused primarily by AEDs, suggesting that malformations can be prevented by improvements in drug regimen, and by avoiding polypharmacy and high levels of VPA (more than 70 microg/ml) in the treatment of epileptic women of childbearimg age.

Abnormalities, Drug-Induced↗

Intrauterine growth in the offspring of epileptic women: a prospective multicenter study.

The aim of the present study was to evaluate the risk of intrauterine growth delay in the offspring of epileptic mothers and to quantify the risks of intrauterine exposure to antiepileptic drugs (AEDs). Data concerning 870 newborns, prospectively collected in Canada, Japan and Italy, using the same study design, were pooled and analyzed. The overall proportion of newborns whose body weight (7.8%) or head circumference (11.1%) at birth were below the 10th percentile was not increased. However, logistic regression analysis showed that the risk of small head circumference was significantly higher in Italian than in Japanese (RR 4.2; 95% CI: 2.2-8.0) or Canadian children (RR 2.6; 95% CI: 1.1-6.5), and in children exposed to polytherapy (RR 2.7; 95% CI: 1.2-6.3), phenobarbital (PB) (RR 3.6; 95% CI: 1.4-9.4) and primidone (PRM) (RR 4.5; 95% CI: 1.5-13.8). Country was also the only factor affecting low body weight, with Italian children having a higher risk than Japanese (RR 5.2; 95% CI: 2.6-10.4) or Canadian (RR 8.8; 95% CI: 2.0-38.1) children. Due to the small categories, the influence of AED doses and plasma concentrations was studied for each individual AED, without adjustment for the other potential confounding factors. A clear dose-dependent effect was found for PB and PRM in terms of both small head circumference and low body weight, and a concentration-dependent effect for PB in terms of small head circumferences. The size of the difference between the Italian and the other two populations, which is only partially explained by differences in therapeutic regimens, suggests that genetic, environmental and ethnic factors also need to be taken into account when considering possible explanations.

Anticonvulsants↗

Malformations in offspring of women with epilepsy: a prospective study.

PURPOSE: The incidence of malformations among infants of mothers with epilepsy treated with antiepileptic drugs (AEDs) during pregnancy is higher than that found in the general population. The aim of this study was to contribute to providing a definition of the rate of congenital anomalies in the offspring of mothers with epilepsy and to detect possible risk factors. METHODS: Since 1977, 517 pregnancies were followed up at the San Paolo Hospital in Milan by a team of epileptologists and obstetricians. The patients received monthly obstetric and neurologic examinations, and the blood levels of AEDs were tested monthly. During pregnancy the patients underwent ultrasound investigations to evaluate fetal morphology and development. At the time of delivery, the infants were submitted to a standardized examination by a pediatrician, and a more detailed clinical examination was performed on day 5. Malformations were classified as (a) genetic and chromosomic, (b) severe and mild malformations, and (c) deformities. RESULTS: The overall rate of malformations was 9.7%: of these, 5.3% were structurally severe, 2.2% were mild, 0.4% were chromosomic-genetic, and 1.8% were deformities. No malformation was detected in the 25 untreated patients. CONCLUSIONS: The risks of teratogenicity have been regarded as multifactorial, involving such factors as genetic predisposition, although most prospective studies show that AED-related factors are the primary risk factors for an increased incidence of congenital malformations.

Abnormalities, Drug-Induced↗

Steady state maternal-fetal leucine enrichments in normal and intrauterine growth-restricted pregnancies.

The aim of this study was to compare the fetal/maternal (F/M) leucine-enrichment ratio in normal (AGA) and intrauterine growth-restricted (IUGR) pregnancies at the time of fetal blood sampling (FBS). A maternal primed-constant infusion of L-[1-13C]-leucine was given in six AGA and 14 IUGR pregnancies, divided into three groups according to the pulsatility index (PI) of the umbilical artery and to fetal heart rate (FHR): group 1 (normal FHR and PI, four cases); group 2 (normal FHR and abnormal PI, five cases); and group 3 (abnormal FHR and PI, five cases). Maternal arterialized samples were taken at time zero and every 20 min for 125+/-7 min. Umbilical venous samples were obtained after 114+/-42 min of infusion. Under steady state conditions, there was a significant linear relationship between maternal leucine disposal rate and maternal leucine concentration. The comparison of fetal to maternal leucine enrichment showed a progressive dilution of the fetal enrichment relative to the mother between AGA and IUGR of group 1 (0.89 versus 0.78, p < 0.02), group 2 (0.71, p < 0.001), and group 3 (0.62, p < 0.001), and also among the three IUGR groups. The F/M leucine molar percent enrichment (MPE) ratio showed a positive correlation with the umbilical venous oxygen content and an inverse correlation with fetal lactate concentration. We conclude that the dilution in the fetal/maternal leucine-enrichment ratio correlates with the severity of growth restriction and reflects decreased transplacental leucine flux and/or increased protein breakdown within the fetoplacental compartments.

Adult↗

[Frequency and practice of prescribing prenatal HIV tests during pregnancy].

BACKGROUND: To assess frequency and practices of antenatal HIV testing. METHODS: Cross-sectional study. Site: obstetric units of San Paolo Hospital, Milan (teaching, public, 60 beds, 1500 deliveries/years, reference centre for HIV and pregnancy) and of Sandro Pertini Hospital, Rome (public, urban, 36 beds, 1500 deliveries/year). PARTICIPANTS: parturients consecutively admitted for delivery, in the last three months of 1997. INTERVENTION: interview by a structured questionnaire. Out-comes: frequency and practices of antenatal HIV testing. RESULTS: About 79% of the 500 parturients admitted at the San Paolo Hospital and 57% of the 300 at the Pertini Hospital had been tested for HIV during the current pregnancy (p < 0.001). Overall, in 91% of cases (507/555) the test has been requested by the woman's gynecologist with other antenatal tests. Discussion on HIV testing, infection and pregnancy lasted less than 5 minutes in 92% of San Paolo parturients, and in almost all (99.4%) of the Pertini women. Women in the San Paolo hospital had HIV information available by leaflets in 47% of cases in comparison to 35% of those at the Pertini hospital. CONCLUSIONS: In Italy, HIV testing seems to be routinely included in the management of pregnancy, although the uptake and practices of offering the test seem not always appropriate. The higher uptake and the better practice seem to correlate with the higher involvement of San Paolo hospital in the fields of HIV infection in pregnancy. However, the reported overall 71% of tested parturients suggests that in Italy we are still far away from a universal antenatal HIV testing. Specific guidelines should be issued in order to implement and to uniform universal antenatal HIV testing, and to optimize the management of infected women.

Adolescent↗

Blood flow through the ductus venosus in human fetus: calculation using Doppler velocimetry and computational findings.

The present study was performed to assess a new method to calculate the blood flow rate through the ductus venosus (DV) in normal human fetuses using available echo-Doppler data. Color Doppler sonographic unit was used to study DV flow in 26 normal fetuses between 20 and 36 wk of gestation. Maximal velocity flow tracings and vessel diameters were obtained at the isthmic and the outlet portion of the DV. Time-averaged velocities in the DV were measured from the recorded tracings. The velocity distribution in the two investigated cross-sectional areas of the DV was evaluated by means of computational model simulations and the velocity shape coefficients h(in) and h(out), (i.e., the ratios between the maximal and mean spatial velocities) were calculated as a function of vessel geometry. These values allowed us to convert maximal Doppler velocities into mean spatial velocities for each fetus. Blood flow rate was evaluated both at the isthmus and at the outlet of the vessel by means of two formulae based on the ultrasonographic measures and the results of the computational model. The value of the DV blood flow rate was calculated as the average between the results provided by the two formulae. The velocity distributions both at the isthmus (h(in) = 0.677 +/- 0.040) and the outlet (h(out) = 0.374 +/- 0.072) of the ductus are skewed toward the inner wall. Ductus geometry, i.e., the isthmic/outlet diameter ratio, affects the shape of the velocity profiles in the vessel, particularly that at the outlet. The coefficients of variation for repeated measurements of the ductal diameters were 9.5 +/- 7.7% and 6.7 +/- 4.9% at the isthmus and the outlet, respectively. The two formulae gave values statistically identical for the time-average blood flow rate (36.3 +/- 22.1 vs. 39.4 +/- 24.0 mL/min; R = 0.946, p = NS). The mean percent difference between the results of the two formulae was 7.1%. Thus, in human fetuses, the use of the two formulae based on both Doppler data and computational model simulations makes it possible to calculate the ductal flow rate. When the difference between the calculations of the two formulae exceeds the 30% of their average value, it is convenient to adopt the flow rate value calculated at the isthmus instead of the average of the two measures. The measurements at the outlet of the ductus were more difficult to obtain, and the spatial velocity profile at the outlet depends more on the DV anatomy.

Blood Flow Velocity↗

Absence of hepatitis C virus and detection of hepatitis G virus/GB virus C RNA sequences in the semen of infected men.

The identification of hepatitis C virus (HCV) in semen remains controversial and that of hepatitis G virus (HGV) or GB virus C (GBV-C) has never been investigated. Serum and semen from 90 anti-HCV-positive drug users were tested (27 infected with HIV) for HCV and HGV/GBV-C RNAs by polymerase chain reaction (PCR) assay, hybridization, and sequence analysis. Semen was processed into round cells, seminal plasma, and spermatozoa. Fifty-six patients were HCV-viremic, but HCV-RNA was not identified in their seminal fractions. However, PCR inhibitors were found in the semen of 34 of these men. Twenty-eight patients had HGV/GBV-C RNA in their blood and for 24 of them, ejaculates were available for analysis. HGV/GBV-C RNA was found in the seminal plasma of 6 of 12 samples free from PCR inhibitors. These results agree with the low risk of sexual transfer of HCV and provide preliminary evidence for the presence of HGV/GBV-C in semen.

AIDS-Related Opportunistic Infections↗

A randomised trial of mode of delivery in women infected with the human immunodeficiency virus.

OBJECTIVE: During the pilot phase of a trial to evaluate the effectiveness of caesarean section delivery compared with vaginal delivery in reducing mother-to-child transmission of human immunodeficiency virus (HIV) infection, the feasibility of randomisation to mode of delivery was assessed. DESIGN: At 36 weeks of pregnancy, women infected with HIV were randomly allocated to either caesarean section delivery at 38 weeks or vaginal delivery. Information was also collected on the reasons why women were not enrolled, either because they refused or had a contraindication. SETTING: Fifty-one centres in six European countries. POPULATION: Pregnant women with confirmed HIV-1 infection. MAIN OUTCOME MEASURES: Randomisation. RESULTS: Three-hundred and thirty-nine women had been randomised by the end of 1996, the large majority from Italy (n = 250) and France (n = 54), with 22 from South Africa, three from Sweden, nine from Barcelona and one from London. A further 150 women were eligible but had not been randomised. Forty-eight women (14%) were not delivered according to the arm to which they were randomised; the majority (n = 44) were changed from vaginal to caesarean section delivery. There is wide variation between European countries in the acceptability and adherence to the mode of delivery trial. CONCLUSION: The pilot phase of this trial has shown that in some settings randomisation to mode of delivery is feasible and acceptable, but that in other settings clinicians and pregnant women are more reluctant to be randomised. Pending further information on transmission rates and accrual, enrollment into the trial continues.

Cesarean Section↗

Dilatation of the ductus venosus in human fetuses: ultrasonographic evidence and mathematical modeling.

Autonomic regulation of blood flow through the fetal ductus venosus has been suggested, but the existence of a sphincter at the ductal entrance in human fetuses has yet to be established. In this paper two cases of apparent ductus venosus dilatation in two growth-restricted human fetuses are reported. Prolonged ultrasonographic analysis (45 min) showed rapid and substantial changes (>80%) of ductal diameters. Pulsed Doppler analysis was used to investigate flow velocity in the ductus venosus and umbilical vein for both normal and dilated conditions. Dilated conditions caused manifest modifications of velocity tracings. Systolic peak velocity in the ductus did not change visibly, whereas velocity at the atrial contraction showed evident reduction; consequently, pulsatility indexes increased. Furthermore, the umbilical vein presented flow velocity pulsations. The mean blood flow rate through the ductus seemed to increase substantially (>70%) for high dilatation. To investigate these findings further, we performed simulations of ductal dilatation by means of a lumped-parameter mathematical model of the human fetal circulation. Model results agreed with clinical evidence and confirmed the relationship between ductal dilatation and the observed velocity alterations. Simulated systolic peak velocity slightly increased for small dilatation (<30%), whereas atrial velocity was reduced when the ductus dilated. Furthermore, the model indicated that umbilical venous pressure decreases for increasing dilatation, whereas no change occurs in the central venous pressure. The present results seem to indicate the presence of active dilatation of the ductus venosus in human fetuses.

Female↗

Pathophysiology of intrauterine growth retardation: role of the placenta.

The placenta is essential for normal fetal development. Failure of the placenta can result in many fetal conditions, for example, intrauterine growth retardation (IUGR). Placentas from pregnancies complicated by IUGR show vascular damage, which may lead to the onset of pregnancy-induced maternal hypertension. Accurate placental assessment may, therefore, indicate which fetuses are at risk of IUGR and so improve clinical evaluation and management of both the fetus and the mother. Placental development and function can be assessed by a number of methods, including measurement of placental weight at mid-gestation (placental growth in the second trimester correlates strongly with placental weight at birth), assessment of fetal and placental circulation (an association between perinatal morbidity and abnormal blood velocity profiles has been established) and assessment of placental metabolism and nutritional transfer (a reduction in transfer of nutrients may be an early indicator of IUGR.

Female↗

Association between the activity of the system A amino acid transporter in the microvillous plasma membrane of the human placenta and severity of fetal compromise in intrauterine growth restriction.

Primarily, our objectives were to compare system A amino acid transporter activity in the microvillous plasma membrane (MVM) of placentas from normally grown (appropriate for gestational age, AGA) and intrauterine growth-restricted (IUGR) fetuses delivered during the third trimester, as a whole and in relation to the severity of IUGR. Ten AGA and 16 IUGR pregnancies were studied at the time of elective cesarean section performed between 28 and 40 wk of gestation. Severity of IUGR pregnancies was assessed primarily by Doppler velocimetry and fetal heart rate monitoring. Placental MVM vesicles were prepared, and system A activity in these was measured. The transporter activity was significantly lower in IUGR compared with AGA pregnancies. Within the IUGR group system A activity was only significantly lower, compared with AGA, in cases that presented with a reduction in umbilical blood flow. We conclude that placental MVM system A activity is lower in IUGR compared with AGA pregnancies delivered during the third trimester. System A activity is related to the severity of IUGR.

Alkaline Phosphatase↗