Search PubMed⌕ Search

Biomedical subjects

G Panol

Publications and source records attributed to G Panol.

16 recordsLinked to original sources

Gas transport in the intracorporeal oxygenator with woven tubes.

The woven tubes membrane oxygenator is a suitable configuration for the intracorporeal membrane oxygenator because of a high gas exchange performance and a compact packing of tubing. In this study the oxygen transfer performance of woven tubes was evaluated by an in vitro experiment with an external perfusion mode; the blood flow is outside of the tubes in order to reveal the feasibility of designing the intravascular oxygenator (IVOX) by the woven tubes. The oxygen transfer efficiency of the external perfusion mode is superior to that with the internal perfusion mode because of the larger convective mixing effect on the external surface of the tubes. Thus the use of the external perfusion mode results in the shorter necessary tube length for the rated condition, which enables making the oxygenator unit more compact. All of these features encourage the adoption of the woven tubes for use in the intravascular oxygenator.

Animals↗

Lactic acidosis transiently increases metabolic rate of turtle myocytes.

We measured O2 consumption as an estimate of metabolic rate in isolated calcium-tolerant ventricular myocytes of turtles (Chrysemys picta belli) at control pH 7.8 and in the same solution brought to pH 7.4 and 7.0 with additions of lactic acid. Our aim was to test the hypothesis that lactic acidosis caused metabolic depression by initiating downregulation of Na+ channels, and thus Na(+)-K(+)-ATPase (Na+ pump) activity, which we would measure as a decrease in O2 consumption. Myocyte O2 consumption was measured in reptilian N-tris(hydroxymethyl)methyl-2-aminoethanesulfonic acid-buffered Ringer solution and in nomially Na(+)- and Ca(2+)-free solution, thus estimating the Na+ pump component of metabolic rate. Lowering extracellular pH from 7.8 to 7.0 resulted in a significant increase in metabolic rate of cells in Ringer solution but not those in Na(+)- and Ca(2+)-free solution. This result was unchanged by the addition of 2 mM Ca2+ to Na(+)-free cell suspensions, indicating that the difference was due to the presence of Na+. Addition of 100 microM amiloride to cells in Ringer solution at pH 7.0 abolished the increase in O2 consumption, suggesting that the apparent increase in Na(+)-K(+)-ATPase activity was secondary to Na(+)-H+ exchange. Intracellular pH was measured using 5,5-dimethyl[14C]oxazolidine-2,4-dione. Cells treated with amiloride and those in Na(+)- and Ca(2+)-free solution did not regulate intracellular pH following acidosis and maintained basal metabolic rate. These data suggest that the Na(+)-H+ exchanger is an important contributor to intracellular pH regulation in the myocyte but increases Na+ pump activity and metabolic rate immediately following acidosis.

Acidosis, Lactic↗

31P-NMR study of normoxic and anoxic perfused turtle heart during graded CO2 and lactic acidosis.

We studied the effects of graded acidosis (both CO2 and lactic acid) and anoxia on intracellular pH (pHi) regulation, high-energy phosphates, and mechanical function of isolated perfused hearts of the turtle (Chrysemys picta bellii) at 20 degrees C using 31P-nuclear magnetic resonance (NMR) spectroscopy. During CO2 acidosis, anoxia had no effect on apparent nonbicarbonate buffer value (d[HCO3-]/dpHi = 71 and 89 mM/pH in normoxia and anoxia, respectively) or on pHi regulation (dpHi/dpHe = 0.52 and 0.43 in normoxia and anoxia, respectively, where pHe is extracellular pH). During normoxic lactic acidosis, dpHi/dpHe was similar to the values observed in CO2 acidosis and averaged 0.55 overall. During anoxic lactic acidosis, however, similar regulation occurred over only a narrow range of pHe, and then dpHi/dpHe increased to greater than 1.0 at pHe less than 7.1. Creatine phosphate (CP), calculated as the area of the NMR peak, fell more in response to normoxic CO2 acidosis than to normoxic lactic acidosis; in anoxia, the fall in CP was further increased but to similar extreme levels (10-20% of control) in both acid perfusions. Cardiac output and maximum rate of pressure development each fell during acidosis in similar fashion in all protocols, and the responses were similar in normoxic and anoxic hearts. Heart rate, in contrast, decreased during acidosis, but this effect was more pronounced when hearts were anoxic. We conclude that the effect of acidosis on cardiac function can depend on the type of acidosis imposed. Based on the heart's insensitivity to anoxia alone, we suggest that anoxia may normally depress function indirectly via its effect on intracellular acid-base state.

Acidosis, Lactic↗

Artificial pancreas using living beta cells:. effects on glucose homeostasis in diabetic rats.

An artificial pancreas consisting of beta cells cultured on synthetic semipermeable hollow fibers was tested in rats with alloxan-induced diabetes. When implanted ex vivo as arteriovenous shunts in the circulatory system these devices lowered concentrations of plasma glucose from 533 to between 110 and 130 milligrams per 100 milliliters, increased concentrations of plasma insulin, and restored intravenous glucose tolerance tests essentially to normal.

Animals↗

Control of water flux in a bioartificial kidney.

UC-PK1 cells were grown to confluence on microporous microcellulose membranes in order to test the feasibility of using transmembrane pressure (TMP) for controlling connective water transport in a bioartificial kidney. TMP was applied on either the apical or basal aspect of the polarized cell layer, while the fluid compartments on both sides of the membrane were perfused with tissue culture medium in a miniature flow chamber. The cell monolayer did not allow filtration in the apical to basal direction when positive TMP up to 30 mmHg was applied on the apical side. Application of positive TMP on the basal side led to measurable ultrafiltration. The hydraulic permeability, L(p), of the cell-seeded membranes was found to be increasing with time, reaching a steady state value after 60 min. There was a strong positive correlation between L(p) and applied TMP. For a constant TMP, L(p) was found to be independent of the shear rate between 2.6 and 10.5 sec-1. When positive pressure was changed abruptly back from the basal to apical site, the ultrafiltration rate decreased to zero within seconds. Morphologic studies suggest that the tight junctions between cells were broken by TMP applied on the basolateral aspect of the cell monolayer. It is concluded that, basolateral TMP may be used to control water flux in a bioartificial kidney.

Animals↗

Small intrapulmonary artery lung prototypes: design, construction, and in vitro water testing.

Blind-ended, hollow fibers mounted on a pulmonary artery catheter may allow O2 and CO2 transfer in the vena cava, right ventricle, and pulmonary artery. The effects of fiber length, manifold number, and gas oscillation on mass and momentum transfer with water perfusate using mass spectrometry and mass flow controllers were studied. Manifolds with 112-196 microporous polypropylene fibers were mounted on 8 Fr multiple lumen, commercially available pulmonary artery catheters. Fiber lengths varied from 0.5 to 16 cm and surface areas from 7 to 220 cm2. Prototypes with 2 cm long fibers were constructed with 1-15 manifolds. A two manifold prototype with 8 cm long fibers and a surface area of 378 cm2 was also studied. The transfer failed to scale with manifold number because the steady gas flow was maldistributed to the manifolds. Oscillating gas pressures from 780 to 76 mmHg absolute at a rate of 40 cycles/min increased CO2 transfer up to 15-fold and O2 transfer up to 2.5-fold. Oscillation also corrected the maldistribution. Optimal fiber lengths of 3 and 1 cm for O2 and CO2, respectively, were seen with steady gas flow, and 8 cm for both with oscillatory gas flow.

Artificial Organs↗

Small intrapulmonary artery lung prototypes. Mathematical modeling of gas transfer.

Two diffusion models have been developed to analyze gas transfer data previously measured in an intravascular artificial lung consisting of a central gas supply catheter from which are tethered a large number of blind-ended microporous fibers of equal length. A convective-diffusion model (CD) describes the countercurrent transfer of a binary gas pair when gas is supplied at constant pressure conditions, and a well mixed (WM) cycled pressure model predicts transfer when the gas supply pressure is time cycled between compression and vacuum conditions. Regression of gas to gas and liquid to gas excretion data with the CD model resulted in estimates of the liquid phase mass transfer coefficient kAI. Because these values were intermediate between the kAI expected for flow parallel to a cylinder and for flow normal to a cylinder, gas transfer was influenced by both the tethered region of the fiber that was nearly perpendicular to the axis of the test section and the free end of the fiber that rested along the wall of the test section. With a time cycled gas supply pressure, the enhanced carbon dioxide and oxygen excretion predicted by the WM model was similar to the data, but a loss in transfer efficiency with fiber length was not accounted for by the theory.

Algorithms↗

The bioartificial kidney: progress towards an ultrafiltration device with renal epithelial cells processing.

The combination of an ultrafiltration device with an exchanger whose semipermeable hollow fibres are covered with renal epithelial cells is proposed as a design for a bioartificial kidney. We first demonstrated that continuous ultrafiltration can be maintained for relatively long periods in the absence of anticoagulation. As a second step, we report here the feasibility of attaching and growing two lines of kidney epithelial cells (MDCK and LLC-PK1) on two different semipermeable materials, an acrylic copolymer and a polysulphone. Cells seeded on acrylic copolymer hollow fibres reach confluence within three weeks. Depending on the chemical and/or physical properties of the polymer, the cells show distinct differentiated morphology, which may influence their ability to perform specialized tasks.

Bioprosthesis↗