Search PubMed⌕ Search

Biomedical subjects

G Ohqvist

Publications and source records attributed to G Ohqvist.

21 records · Page 2Linked to original sources

Plasma colloid osmotic pressure during open-heart surgery using non-colloid or colloid priming solution in the extracorporeal circuit.

Two different priming solutions for the heart-lung machine were compared in 14 patients during aortic valve replacement. Colloid osmotic pressure (COP), and albumin in plasma, blood erythrocyte volume fraction (B-EVF) and arterial oxygen tension (PaO2) (FIO2 = 1.0) were followed before, during and after perfusion. The two priming solutions were 2,000 ml Ringerdex (7 patients) or 1,800 ml Ringerdex + 200 ml 20% albumin (7 patients). COP and B-EVF were normal before bypass. After 10 min on bypass, when about 1,000 ml of crystalloid cardioplegic solution had been given, COP was reduced by about 50% and B-EVF fell to 23%, indicating a small loss of water from the circulation when compared with in vitro dilution curves. COP was slightly lower in the non-colloid group (p less than 0.02). Both COP and B-EVF remained unchanged during perfusion, despite transfusion from the heart-lung machine of a mixture of blood and crystalloid solution with a calculated very low COP (6 mmHg) and B-EVF (15%). After perfusion the restitution of COP and B-EVF was rapid and parallel. Both returned to normal levels after 2 hours. There was a good correlation between COP and albumin measured in the same plasma samples (r = 0.83, p less than 0.001). At one hour after bypass PaO2 (FIO2 = 1.0) tended to decrease in the non-colloid group, compared with preperfusion level. 40 g of albumin was a too small amount of colloid to diminish substantially the reduction of COP during perfusion. The unchanged levels of COP and B-EVF during perfusion, despite further dilution as well as the parallel normalization after perfusion, can only be explained by loss of water from the circulation.

Adult↗

Pulmonary oxygenation, central haemodynamics and glomerular filtration following cardiopulmonary bypass with colloid or non-colloid priming solution.

Plasma colloid osmotic pressure (COP), blood erythrocyte volume fraction (B-EVF), arterial oxygen tension at an inspired oxygen concentration of 30% (PaO2 (FIO2 0.3)), cardiac index, stroke volume, arterial mean pressure, left atrial mean pressure, pulmonary av-difference of oxygen (Ca-v O2) and creatinine clearance were studied in 16 patients during isolated aortic valve replacement. The patients were divided into two groups with different priming solutions in the oxygenator. In the non-colloid group 2,000 ml of Ringerdex was used, while the colloid group had 1,600 ml of Ringerdex and 400 ml of albumin 20% (80 g). COP differed significantly between the groups (p less than 0.01) during and for 1 hour after bypass. The greatest reductions were 56% and 30%, respectively. Haemodilution (los B-EVF) was of longer duration in the colloid group. No differences between the groups were found with respect to pulmonary oxygenation, myocardial behaviour or glomerular filtration rate. Cardiopulmonary bypass produced no changes in cardiac index, stroke volume, arterial mean pressure, left atrial mean pressure, Ca-v O2 or creatinine clearance in either of the groups. PaO2 (FIO2 0.3) remained unchanged in the non-colloid group and showed a small but significant reduction (p less than 0.01) in the colloid group. No positive effects of a colloid prime were demonstrated.

Adult↗