Sterile stromal melt of epikeratoplasty lenticule.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G O Waring.
Explore the source record for details and available documents.
The authors reviewed in a retrospective manner 47 penetrating keratoplasties performed on 23 eyes of 21 patients with rheumatoid arthritis. The indications for the first penetrating keratoplasty were corneal melt in 19 eyes (83%), infectious keratitis in 2 eyes (9%), and corneal scarring after ulceration in 2 eyes (9%). Twelve of the 23 eyes required 24 repeat penetrating keratoplasties. Seventeen of the 23 eyes (74%) had clear grafts at the last follow-up visit, a median of 13.7 months after the last penetrating keratoplasty. The final best corrected visual acuity was greater than or equal to 20/60 in 4 eyes (17%), 20/70 to 20/100 in 1 eye (4%), 20/200 to 20/400 in 7 eyes (30%), counting fingers in 4 eyes (17%), hand motions in 2 eyes (9%), and light perception in 4 eyes (17%). One eye (4%) was enucleated. Anatomic success (absence of phthisis bulbi, enucleation, or conjunctival flap) was achieved in 20 eyes (87%). The survival probability for the 21 patients was only 48% 5 years after the first penetrating keratoplasty. The authors conclude that penetrating keratoplasty is often anatomically successful in patients with rheumatoid arthritis; however, the prognosis is poor for both vision and survival of the patient.
A 20-year-old man was evaluated for an indolent corneal ulcer. Tissue and cultures from a penetrating keratoplasty indicated that the causative agent was Mycobacterium gordonae. This is the third patient reported with M. gordonae keratitis, although there have been numerous reports of nontuberculous mycobacterial keratitis. Nontuberculous mycobacterial keratitis is typically associated with previous trauma. The patient reported here had no known predisposing factor.
The immunocytologic characteristics of two formalin-fixed, paraffin-embedded corneas from patients with the iridocorneal endothelial (ICE) syndrome and unaffected control corneas were studied. Binding of polyclonal antisera to Factor VIII, S-100 protein, involucrin, neuron specific enolase (NSE), and the lectins peanut agglutinin and Ulex europaeus agglutinin-1 was performed using the standard peroxidase-anti-peroxidase method. We detected reactive patterns of monoclonal antibodies to cytokeratins (34BE12 is a 56-58 kD mouse IgG reactive to stratified epithelia; Pkk1 is a 44-54 kD mouse IgG reactive to simple epithelia; and KL1 is a 55-57 kD mouse IgG reactive to epidermis and simple epithelia) using the standard avidin-biotin complex method. Staining properties were similar for the polyclonal antisera, lectins, NSE, and chromogranin in corneas with ICE syndrome and in the controls. However, the cytokeratins 34BE12, Pkk1, and KL1 were detected in the endothelium of the corneas with the ICE syndrome but not in the controls. These findings suggest that various cytokeratins are expressed in the corneal endothelium in the ICE syndrome that are not expressed in unaffected corneal endothelium.
Explore the source record for details and available documents.
The Prospective Evaluation of Radial Keratotomy Study is a nine-center clinical trial of a standardized technique of radial keratotomy in 435 patients who had simple myopia with a preoperative refraction between -2.00 and -8.00 diopters. We studied the stability of the refractive error during four years after surgery for each of 341 eyes first operated on that had a single surgical procedure. Between baseline and two weeks after surgery, all eyes became less myopic; between two weeks and three months, 161 eyes (59%) lost 1.00 D or more of the initial effect; and between three and six months, 266 eyes (95%) had a stable refraction with less than 1.00 D change. The change from six months to four years was less than 1.00 D for 246 eyes (72%). There was 1.00 D or more decrease in surgical effect (increased minus power) for 13 eyes (4%), and 1.00 D or more increase in surgical effect (decreased minus power) for 82 eyes (24%). Eyes with larger amounts of preoperative myopia and smaller diameter of the clear zone were more likely to have an increasing effect of the surgery. The duration of this continued increasing effect of the surgery is unknown.
To better define the relationship between residual refractive error, uncorrected visual acuity, and pupil diameter, we compared 42 eyes that had an eight-incision radial keratotomy according to the Prospective Evaluation of Radial Keratotomy Study protocol with 42 matched control eyes. The parameters measured were best corrected visual acuity, uncorrected visual acuity, and the change in cycloplegic refraction with enlarging pupil diameter. The best corrected visual acuity was 20/16 in both the radial keratotomy and control groups, but the variability (SD) was higher in the radial keratotomy group. The average uncorrected visual acuity was 0.35 (35%) better in the radial keratotomy group, but the variability was 1.77 times higher. Change in refraction with dilation occurred in 9% of the controls and 36% of the radial keratotomy patients, indicating a significant difference (P = .002). The change in refraction with dilation in the eyes with radial keratotomy was almost equally split between a hyperopic change (17%) and a myopic change (18%), which was much different than in the control eyes, only 2% of which changed in a hyperopic direction and 7% in a myopic direction. The radial keratotomy patients with a myopic change had the best uncorrected visual acuity, indicating that positive spherical aberration yielded the best aspherical surface for uncorrected visual acuity.
We used computer-assisted videokeratography to compare the topographies of 32 corneas from 23 subjects after radial keratotomy with those of 47 normal corneas from 47 subjects controlled for age and preoperative keratometric and refractive power. Three ophthalmologists independently classified color-coded videokeratographs based on the color-coded pattern of dioptric power distribution and the cross-sectional shape. Corneas that had radial keratotomy exhibited a polygonal pattern not seen in normal eyes; this occurred in 59% of corneas. All normal corneas demonstrated a cross-sectional shape configuration that was steeper centrally than peripherally; 79% of corneas after radial keratotomy had a shape that was flatter centrally than peripherally. After radial keratotomy, the dioptric power increased from the center to the periphery (radius of approximately 4.6 mm) by 2.8 +/- 2.2 diopters (mean +/- SD), with a sharp inflection zone ("paracentral knee") 2.7 mm from the center; normal corneas showed a smooth decrease in power from the center to the periphery of 1.9 +/- 0.5 diopters.
We performed trapezoidal keratotomy, consisting of combined nonintersecting semiradial and transverse incisions, in 64 eyes of 45 consecutive patients with naturally occurring astigmatism. The central clear zone diameter and number and length of transverse incisions were determined by the refractive error. Mean preoperative refractive astigmatism was 3.18 +/- 1.16 diopters (D) (range, 2.25 to 7.00 D). At the 1-year follow-up examination, the mean surgically corrected astigmatism determined by vector analysis was 3.70 +/- 1.50 D (range, 0.75 to 8.5 D), and the mean residual refractive astigmatism was 0.85 +/- 0.72 D (range, 0 to 4.0 D), with 64% of eyes having 1.00 D or less. The smaller the clear zone diameter, the greater the astigmatic correction. Longer transverse incisions produced more steepening of the secondary meridian. The operative complications included microperforation (5%), misalignment of surgical meridian (6%), encroachment on clear zone (5%), and inadvertent crossed incisions (11%). Trapezoidal keratotomy reduced naturally occurring astigmatism, but with only fair predictability and with some irregular astigmatism due to irregular wound healing.
We used a Q-switched Nd:YAG laser with non-linear optical crystals to produce the 5th (213 nm) and the 4th (266 nm) harmonic frequencies. Using these two wavelengths, we ablated fresh porcine corneas and type I collagen synthetic epikeratoplasty lenticules. For the 213-nm ablation, radiant exposure was 1.3 J/cm2. The ablation rate was 0.23 micron per pulse for the epikeratoplasty lenticules. We examined all tissues with light microscopy, transmission electron microscopy, and scanning electron microscopy. Histology for the 213-nm ablation showed a clean ablation crater with minimal collagen lamellae disruption and a damage zone less than 1 micron. In comparison, the 266 nm radiation showed more charring at the edges with a damage zone approximately 25 microns deep with disruption of the stromal lamella. Our results show that this solid state UV laser is a potential alternative to the excimer laser for cornea surgery.
In the Prospective Evaluation of Radial Keratotomy (PERK) Study, 793 eyes of 435 patients with 2 to 8 diopters (D) of myopia received a standardized surgery consisting of 8 incisions with a diamond-bladed knife set at 100% of the thinnest paracentral ultrasonic corneal thickness measurement and a diameter of the clear zone of 3.0 to 4.5 mm; 97 eyes (12%) received an additional 8 incisions. There were 757 eyes (95%) followed for 3 to 6.3 years. After surgery, uncorrected visual acuity was 20/40 or better in 88% of eyes. The refractive error was within 1 D of emmetropia for 64% of eyes; 19% were myopic and 17% were hyperopic by more than 1 D. Between 6 months and 5 years after surgery, 22% of the eyes had a refractive change of 1 D or more in the hyperopic direction. For 25 eyes (3%) there was a loss of 2 or more lines of best spectacle-corrected visual acuity.
The authors enrolled 95 patients with keratoconus and 96 matched controls in a cross-sectional study to determine if mitral valve prolapse and hypermobile joints occur with greater frequency in individuals with keratoconus than in individuals without keratoconus. The hypothesis that keratoconus may not be a distinct eye disease, but a nonspecific sign representing a more generalized systemic disorder, possibly a mild collagen tissue abnormality, was considered. M-mode and two dimensional echocardiography and cardiac auscultation detected no statistically significant difference in the prevalence of mitral valve prolapse in patients with keratoconus compared with controls. Formal, systematic examination of five joints also failed to detect a statistically significant difference in the prevalence of hypermobile joints in keratoconus patients and controls. However, as an ancillary finding, a significantly higher proportion of patients with keratoconus was found to have a history of hay fever than was the case with controls.
Explore the source record for details and available documents.
The first operated eyes of 435 patients undergoing radial keratotomy in the Prospective Evaluation of Radial Keratotomy (PERK) study were evaluated by photokeratography to document the preoperative and postoperative corneal shape. We determined by regression analysis and analysis of variance that the corneal shape preoperatively improved the prediction of the corneal shape 6 months postoperatively in the 3-mm-clear-zone population. The reduction of myopia in all 435 eyes ranged from 1.25 to 9.75 diopters. We studied the effect of the preoperative corneal shape on this variability in the outcome of the surgery using rings 2 and 7 on photokeratography and corneal diameter. In the 3-mm-clear-zone group, eyes with flat prolate corneas had a greater reduction in myopia (4.65 D); those with steeper, more spherical corneas had less reduction in myopia (3.48 D). In addition, eyes with a 3-mm clear zone and flat central corneas alone (8.0 mm = 42.19 D) flattened approximately 0.75 D more than those with steep central corneas (7.0 mm = 48.21 D). In the 3.5-mm and 4.0-mm clear zone groups, the change in corneal curvature was not related to the preoperative curvature. A stepwise regression analysis of the 151 eyes in the 3.0-mm-clear-zone population demonstrated the following predictive equation for radial keratotomy; change in cycloplegic refraction = -14.55 + [-2.097 x average ring-2 radius] + [3.605 x average ring-7 radius] + [0.69 x horizontal corneal diameter] + [0.079 x age] + [-0.379 x spherical equivalent cycloplegic refraction]. There was a 1.17-D observed difference in the effect of radial keratotomy between those eyes with a steep/steep corneal topography (7.2% of the 3.0-mm-clear-zone population) and the flat/flat topography (29% of the 3.0-mm-clear-zone PERK population). A knowledge of corneal topography provides an additional tool for understanding the operative variability of radial keratotomy.
The Prospective Evaluation of Radial Keratotomy Study is a nine-center clinical trial of a surgical technique to reduce simple myopia by making incisions in the cornea. There were 435 patients (one eye per patient is reported) enrolled in the study with a 91% follow-up rate at 4 years after surgery. After surgery, uncorrected visual acuity was 20/40 or better in 76% of eyes. Fifty-five percent of the eyes had a refractive error within +/- 1.00 diopter; 28% were undercorrected, and 17% were overcorrected by more than 1.00 D. The width of the prediction 90% interval for the refractive change was 4.42 D, indicating a lack of predictability. The refractive error was not stable in some eyes; between 6 months and 4 years after surgery, 23% of eyes had a continued effect of the surgery of more than 1.00 D. For 323 patients with both eyes operated on, 64% stated they wore no optical correction. There were few serious complications. Eleven eyes (3%) lost two or three lines of best corrected visual acuity. Two eyes developed delayed bacterial keratitis without significant loss in best corrected visual acuity.
To determine the reproducibility of currently available instruments for measuring corneal power, two investigators measured comparable locations on 18 normal human corneas using a keratometer (Bausch & Lomb, Rochester, NY), the Corneascope (Kera Corp, Santa Clara, Calif), and the Corneal Modeling System (Computed Anatomy Inc, New York, NY). (For the two keratoscopes, average powers around rings at comparable locations were used.) Comparisons made between instruments at the significance level of .05 indicated that the keratometer was more reproducible than the Corneal Modeling System and the Corneascope, and the Corneal Modeling System was more reproducible than the Corneascope. Of the 31 rings projected on the surface of each cornea by the Corneal Modeling System, rings 2 through 13 were read reasonably reproducibly in that 76% of the measurements on these rings differed by no more than 0.5 diopter. The Corneal Modeling System (software version 1.16) is 83% as reproducible as a keratometer reading at approximately the edge of the 3-mm central zone on normal human corneas and provides information about corneal topography in a more reproducible and visually useful manner than the other two instruments.
Laser myopic keratomileusis (photorefractive keratectomy) was performed on 29 rhesus monkey corneas with an argon fluoride (193-nm) excimer laser and a computer-controlled, moving slit delivery system. The 4-mm-diameter central ablation zone ranged in depth from 11 microns (-2 diopters effect) to 46 microns (-8 diopters effect). Corneas were studied for the 9 months postoperatively by clinical slit-lamp microscopy, and periodically with light and transmission electron microscopy. By 6 weeks, mild to moderate subepithelial haze was apparent in 93% of the corneas, with considerable variability in density. Progressive clearing occurred so that by 6 to 9 months 12 of 13 surviving corneas (92%) were either completely clear (4 corneas) or trace hazy (8 corneas). The epithelium was thickened at 21 days after ablation and returned to normal thickness by 3 months. At 3 weeks, subepithelial fibroblasts were three times the density of normal keratocytes and returned to nearly normal numbers by 9 months. We concluded that the anterior monkey cornea demonstrated a mild, typical wound healing response after excimer laser keratomileusis.
We evaluated the topography of 399 normal corneas in 212 subjects with computer-assisted videokeratography. The mean subject age was 37 years (range, 8 to 79 years). Mean spherical equivalent refraction was -1.00 diopters (range, +5.50 to -8.37 diopters). A qualitative classification system for corneal topography was derived based on patterns seen on color-coded topographic maps. Corneas were classified into groups by three independent masked ophthalmologists based on this system. Patterns included round (22.6%), oval (20.8%), symmetric bow tie (17.5%), asymmetric bow tie (32.1%), and irregular (7.1%). All corneas were steeper centrally and flatter peripherally. There was a statistically significant difference among patterns for keratometric astigmatism, but not for spherical equivalent refraction, mean keratometric power, or age of subject. Classification of normal corneal topography is an important step in the process of characterizing the shape of normal and pathologic corneas.