Search PubMed⌕ Search

Biomedical subjects

G Nazareno

Publications and source records attributed to G Nazareno.

3 recordsLinked to original sources

Use of liquid nitrogen to remove duct tape from a homicide victim.

Removal of duct tape or similar adhesive products from a homicide victim may be facilitated by rapidly chilling the tape surface with liquid nitrogen. Physical separation of tape layers can be performed using the same technique. Cyanoacrylate glue (i.e., "super-glue") may be used to preserve fingerprints on the outer surface of the tape for recovery, or other techniques may be used to recover fingerprints from the outer surface prior to tape removal.

Adhesives↗

Complement and coagulation: causative considerations in contrast catastrophies.

Earlier studies suggest that adverse reactions to injected radiographic contrast media are idiosyncratic. In an attempt to gain a better understanding of pathophysiologic events underlying these reactions, rabbit models injected with lethal dose ranges of a cholangiographic contrast material were studied. These animals showed activation of both the complement and coagulation systems. Externally applied heat potentiated complement consumption and increased mortality. Depleting complement components C3-C9 by cobra venom factor did not prevent activation of coagulation or diminish mortality. However, depleting fibrinogen diminished complement activation and markedly diminished mortality. Heparin, administered at several hourly intervals after contrast challenge, also diminished mortality. These studies suggest that the adverse effects of contrast media in this model system are mediated chiefly by the coagulation system, and that complement, if it participates deleteriously, must involve components up to, but not including, C3. A logical role for the inhibitor of C1 esterase in adverse contrast reactions is considered.

Ancrod↗

The potential of iosulamide meglumine as a contrast material for intravenous cholangiography: an experimental study in dogs.

Because of relatively low acute toxicity, iosulamide meglumine has been recommended as an improved contrast material for intravenous cholangiography. It has been postulated that high doses of the compound could be given safely with the expectation of achieving greater biliary excretion and improved opacification of the biliary tree. Experiments performed in dogs show that higher rates of infusion of iosulamide result in greater urinary elimination without additional biliary excretion. Consequently, iosulamide is unlikely to have any special advantage as a contrast agent.

Animals↗