Integrated microanalytical technology enabling rapid and automated protein identification.

Protein identification through peptide mass mapping by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has become a standard technique, used in many laboratories around the world. The traditional methodology often includes long incubations (6-24 h) and extensive manual steps. In an effort to address this, an integrated microanalytical platform has been developed for automated identification of proteins. The silicon micromachined analytical tools, i.e., the microchip immobilized enzyme reactor (mu-chip IMER), the piezoelectric microdispenser, and the high-density nanovial target plates, are the cornerstones in the system. The mu-chip IMER provides on-line enzymatic digestion of protein samples (1 microL) within 1-3 min, and the microdispenser enables subsequent on-line picoliter sample preparation in a high-density format. Interfaced to automated MALDI-TOF MS, these tools compose a highly efficient platform that can analyze 100 protein samples in 3.5 h. Kinetic studies on the microreactors are reported as well as the operation of this microanalytical platform for protein identification, wherein lysozyme, myoglobin, ribonuclease A, and cytochrome c have been identified with a high sequence coverage (50-100%).

Autoanalysis↗

Capillary liquid chromatography interfaced to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an on-line coupled piezoelectric flow-through microdispenser

A piezoelectric flow-through microdispenser interfacing capillary liquid chromatography (LC) with matrix-assisted laser desorption/ionization time-of-fight mass spectrometry (MALDI-TOF MS) was developed for the identification of biomolecules. The MALDI target plate was placed on a computer controlled high-resolution x-y stage, on to which the column effluent was deposited as discrete spots, which thereby facilitated tracing of the chromatographic separation. The entire target plate was sprayed with a homogeneous layer of alpha-cyano-4-cinnamic acid mixed with nitrocellulose by using an air-brush. Hence the tedious manual handling of a micropipetter applying matrix solution on top of each fraction collected spot was avoided. The pre-made target plates were stable for at least 3 weeks if kept in darkness at room temperature, which easily allowed re-analysis of dispensed sample spots. The integrated microsystem was characterized and optimized by means of fluidics, dispersion, operational stability and sensitivity parameters. The dispensing unit was developed specifically to match high-resolution capillary LC separations using a dispenser with an internal volume from inlet to the ejecting nozzle of 250 nl. Minimizing dead volumes was crucial in order to maintain the chromatographic resolution. The volume of the ejected droplets was of the order of 60 pl. Successful separations of seven immunoregulating peptides were made: ACTH 1-17, bradykinin, enkephalin, angiotensin III, angiotensin II, angiotensin I and ACTH 18-39. On-line sample dispensing on the target plate in combination with trace enrichment followed by automated MALDI-TOF MS identification is demonstrated, reaching a sensitivity of 100 amol.

Journal Article↗

Effects of benzalkonium chloride on innate immunity physiology of the human nasal mucosa in vivo.

OBJECTIVE: Benzalkonium chloride (BC) is a preservative commonly used in nasal decongestant sprays. It has been suggested that BC may be harmful to the nasal mucosa. The present study, involving healthy volunteers, examines effects of BC on nasal mucosal end-organ functions. METHODS: Isotonic saline and BC (0.1 mg/mL) were administered acutely to the nasal mucosa using a nasal pool device. Nasal symptoms were determined. Nasal lavage fluid levels of alpha2-macroglobulin and fucose were measured as indices of plasma exudation and glandular secretion, respectively. In addition, BC (0.1 mg/mL) was given as single actuations of 100 microL per nasal cavity three times daily for 10 days. The ability of histamine (0.4 mg/mL) to evoke nasal symptoms and plasma exudation responses was determined before and after the repeated BC administration series. RESULTS: BC produced immediate nasal smart or pain (P < .05), but tolerance to this response developed by repeated administrations. BC increased nasal mucosal output of fucose (P < .05), whereas nasal lavage fluid levels of alpha2-macroglobulin were unaffected. Histamine produced significant symptoms and mucosal exudation of alpha2-macroglobulin (P values < .01), equally before and after the 10 days of BC exposure. CONCLUSIONS: BC in dosages commonly used as preservative in nasal decongestant sprays produced short-term glandular secretion and nasal smart or pain. However, 10 days' frequent exposure to BC was not associated with untoward symptomatic effects, nor was a sensitive mucosal variable such as histamine-induced exudative responsiveness affected by this repeated exposure 1 BC.

Administration, Topical↗

Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry.

This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture onto a pre-deposited highly diluted matrix spot. The pre-deposited crystals act as seeds for the new sample containing crystals which become much smaller in size and more evenly distributed than with conventional methods. This 'seed-layer' method was developed, optimised and compared with the dried-droplet method using peptides and proteins in the 1000-20,000 Da range. The seed-layer method increases the surface homogeneity, spot to spot reproducibility and sample washability as compared with the commonly used dried-droplet method. This methodology is applicable to alpha-cyanohydroxycinnamic acid, sinapinic acid and ferulic acid, which all form homogeneous crystal surfaces. Within-spot variation and between-spot variation was investigated using statistics at a 95% confidence level (n = 36). The statistical values were generated from more than 5000 data points collected from 500 spectra. More than 90% of the sample locations results in high intensity spectra with relatively low standard deviations (RSDs). Typically obtained data showed an RSD of 19-35% within a sample spot as well as in-between spots for proteins, and an RSD of < or = 50% for peptides. Linear calibration curves were obtained within one order of magnitude using internal calibration with a point-RSD of 3% (n = 10). The sample homogeneity allows mass spectra (average of 16 laser shots) to be obtained on each individual sample within 15 sec, whereby a 100 spot target plate can be run in 25 min. High density target plates using the seed-layer method were prepared by spotting approximately 100 picoliter droplets onto the target, resulting in sample spots < or = 500 microns in diameter using a flow-through piezo-electric micro-dispenser. By using this automated sample preparation step lower standard deviations are obtained in comparison to manually prepared samples.

Coumaric Acids↗

Picoliter sample preparation in MALDI-TOF MS using a micromachined silicon flow-through dispenser.

This paper presents a picoliter sample preparation technique utilizing the flow-through principle, allowing on-line coupling of chromatographic systems to be made. The work was performed in order to investigate the characteristics and the physicochemical properties of the sample preparation using typical mobile phase conditions from mu-CLC (column liquid chromatography) separations. The device presented here is a pressure pulse-driven dispenser, formed by two silicon structures processed by conventional micromachining. The pressure pulse is generated in the flow-through channel by a piezoceramic element. Depending on the orifice size, the droplets ejected range between 30 and 200 pL. The maximum ejection frequency is 500 Hz, limited by resonances within the unit. A pyramid-shaped nozzle improves the directivity of the droplets since it reduces the wetting of the orifice front surface area. The risk of particles sticking close to the orifice is also minimized. The analyses of the deposited sample spots were carried out on a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer with delayed extraction. It was possible to detect attomole amounts (159-248 amol) of various proteins (cytochrome c, ribonuclease A, lysozyme, and myoglobin) from a single droplet of matrix:analyte 1:1 (drop volume approximately 110 pL). Additionally, it was found that sample enrichment could be carried out using multiple depositions on the same spot; i.e., 31 nM of insulin was easily detected when more than four depositions were made on the same spot, while no detection was possible without sample enrichment. Size optimization of the MALDI sample spot gave target zones of 100-500-micron diameter that matched the size of the laser focal point and resulted in a considerably increased sample throughput.

Cell Line↗

On-line coupling of microdialysis sampling with liquid chromatography for the determination of peptide and non-peptide leukotrienes.

An automated on-line sampling method was developed using microdialysis as the simultaneous sampling and sample pre-treatment technique. The extraction fraction values of microdialysis probes sampling different eicosanoids were investigated. The impact of cyclodextrins in the perfusion liquid used for sampling hydrophobic eicosanoids in biological systems was also studied. The total time for one analysis was 7.6 min allowing seven measurements per hour for monitoring kinetic changes in biological systems.

Autoanalysis↗

Rapid alcohol determination in plasma and urine by column liquid chromatography with biosensor detection.

An enzyme based amperometric biosensor used as a selective and sensitive detection unit in column liquid chromatography for the determination of ethanol and methanol in biological fluids such as plasma and urine is described. The reagentless enzyme electrode is based on the co-immobilisation of alcohol oxidase and horseradish peroxidase in carbon paste. The selectivity of the biosensor was found to vary when four various alcohol oxidase enzyme preparations from Candida boidinii, Pichia pastoris, and Hansenula polymorpha were used in the biosensors described. High sensitivity could be obtained for a number of alcohols, organic acids, and aldehydes. Optimisation regarding the sensitivity and selectivity of the four alcohol oxidase co-immobilised biosensors are outlined. A fast and reliable liquid chromatographic separation system with a PLRP-S polymer based separation column used with a phosphate buffer as the mobile phase was optimised using the best biosensor which was based on alcohol oxidase from P. pastoris and which showed the highest turnover rate for alcohols, as the detector for the determination of ethanol and methanol in human urine and plasma samples. The selectivity and stability of the biosensor were retained by working at an applied potential of -50 mV versus Ag/AgCl, the optimal operational potential, and by the casting of a protective membrane on the electrode surface. High selectivity of the enzyme electrode was also found towards other easily oxidisable interfering species normally present in biological fluids. It was found that stable and reliable determinations of ethanol and methanol in plasma and urine could be performed with only a simple dilution and centrifugation step prior to injection into the liquid chromatographic system. An analysis time of 4 min was required for the assay, with a sample throughput of 13 samples h(-1).

Acids↗

Optimal membrane choice for microdialysis sampling of oligosaccharides.

An analytical methodology based on microdialysis sampling, high-performance anion-exchange chromatography and integrated pulsed electrochemical detection for the monitoring of oligosaccharides in bioprocesses is presented. Amylopectin and model maltooligosaccharide standards; glucose, maltose, maltotriose, maltotetraose, maltopentaose, maltohexaose and maltoheptaose were used to demonstrate its versatility in view to sampling in enzymatic bioprocesses. The performance and characteristics of membranes with the same cut-off ranging between 3 and 100 kDa, were evaluated with respect to their extraction fraction (EF), permeability factors, temperature stability and protein (enzyme) interaction. All investigated membranes showed some non-specific interaction with enzymes. The EF and non-specific membrane-enzyme interactions were higher for the polysulfone membranes compared with the polyamide and polyethersulfone membranes. For all saccharides, the EF was independent of the concentration even for a 250-fold change in concentration. The EF and morphology of the membranes in their dehydrated state, as observed using scanning electron microscopy did not show any significant difference between membranes exposed to a 90 degrees C temperature for 3 and 24 h indicating their applicability to the study of high temperature bioprocesses.

Algorithms↗

Fluorescence polarisation for immunoreagent characterisation.

Antibodies were characterised using fluorescence polarisation, a homogeneous assay technique in which all reagents are in solution. Kinetic studies on the association and dissociation of the immunocomplex were performed. A competitive assay was used and the sensitivities, operational linearities, as well as the specificities of the immunoassays were experimentally determined for various antibody preparations with specificity for triazines. Detection limits for atrazine in water samples were determined to be within the range of 0.08-0.4 ng ml(-1) using a 5-min incubation time and a 0.5-ml sample volume.

Animals↗

High sample throughput flow immunoassay utilising restricted access columns for the separation of bound and free label.

A flow immunodetection system with high sample throughput capacity is described for the screening of various analytes. The immunochemical detection principle is based on the chromatographic separation of the formed immunocomplex (AbAg or AbAg*) and the free antigen (Ag) by a restricted access (RA) column, utilising size-exclusion and reversed-phase mechanism. A fluorescein labelled analyte (Ag*) was used in the competitive assay format with fluorescence detection. The speed and simplicity of the assay were the greatest advantages, allowing measurement of the analyte to be carried out in less than 1 min. The biocompatibility and capacity of the restricted access material allowed multiple injections of up to 5000, without any breakthrough of the fluorescent tracer molecule and thus need for regeneration. The flow immunoassay was developed using the well-known atrazine herbicide and some transformation products as model compounds, due to their human toxicity and widespread use. The sample throughput was 80 samples per hour and the detection limits were 1.4 nM (300 pg/ml) for atrazine (Ab I) and 2.3 nM (500 pg/ml) for the sum of triazines (Ab II-III). Different sample matrices, PBS buffer, creek water, and urine were successfully applied in the flow system without the need for any sample handling step. For plasma samples an additional clean-up step using solid-phase extraction had to be included. The resulting detection limits for atrazine in plasma and water samples using this clean-up and trace enrichment procedure were found to be 2 ng/ml and 20 pg/ml, respectively. The analysis could be performed at a sample throughput rate of 400 per 6-h working shift.

Atrazine↗

Optimisation of a heterogeneous non-competitive flow immunoassay comparing fluorescein, peroxidase and alkaline phosphatase as labels.

Off- and on-line strategies for a non-competitive heterogeneous flow immunoassay were developed comparing three different labels. The samples, containing the model compounds digoxin or digoxigenin, were either pre-incubated off-line or on-line in a mixing coil with excess of labelled anti-digoxigenin Fab-fragments. The excess of Fab-fragments was then separated from the digoxin bound Fab-fragments by passing the sample through a column with immobilised digoxin. The off-line immunochemical detection system is suitable for sensitive high through-put screening of the analytes, whereas the on-line system is more suitable for coupling as a post-column detection unit to liquid chromatography. The digoxin and digoxigenin content in the sample were quantified using fluorescein (F) and enzyme (peroxidase (POD), alkaline phosphatase (AP)) labelled Fab-fragments. The fluorescein label was directly measured with the fluorescence detector, whereas a fluorescent enzyme product was measured in the two enzyme based systems, using 3-(p-hydroxyphenyl)-propionic acid (HPPA) and hydrogen peroxide for POD and, and 4-methylumbelliferyl phosphate (4-MUP) for AP. The highest sensitivity and lowest limit of detection (LOD) was obtained with the Fab-POD system with LODs for digoxin and digoxigenin in the off- and on-line configurations of 0.025 and 0.01 nM, respectively. The sample through-put for the off- and on-line systems were 43 and 32 samples per hour, respectively.

Alkaline Phosphatase↗

A flow immunoassay for studies of human exposure and toxicity in biological samples.

This paper describes a heterogeneous competitive flow immunoassay with a high sample throughput which can be used for the screening of smaller analytes in various samples. The method is based on off-line incubation of the analyte (Ag), a fluorescent labelled tracer (Ag*) and the corresponding antibody (Ab). The separation of bound (Ab-Ag*) and free tracer (Ag*) is based on a size exclusion and reversed phase mechanism utilizing a restricted access (RA) column. The column traps the free unbound tracer (Ag*) in its hydrophobic (C18) inner cavity but excludes the large Ab-Ag* complex, which is passed on and measured by the fluorescence detector. The flow immunoassay was developed using the triazine herbicide atrazine as a model compound owing to its human toxicity and widespread use. A sample throughput of 80 samples per hour and a detection limit of 300 pg ml-1 in water were obtained. Urine samples were successfully applied for direct injections into the flow system, while for human plasma samples an additional clean-up step using solid phase extraction was efficiently included where pure extract is obtained with the highly stable and biocompatible extracting column material. The resulting detection limits for atrazine in plasma and water samples using this clean-up and trace enrichment procedure were found to be 2 ng ml-1 and 20 pg ml-1 respectively.

Animals↗

On-line supported liquid membrane-liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit for the determination of phenols in blood plasma.

The potential of on-line combination of supported liquid membrane extraction and column liquid chromatography with a phenol oxidase-based biosensor as a selective detection unit has been investigated for the determination of phenols in human plasma. The phenols are selectively extracted into a porous PTFE (polytetraflouroethene) membrane impregnated with a water-immiscible organic solvent and further into an alkaline acceptor phase. Via an ion-exchange interface, the analytes are transferred to a reversed-phase column where they are separated and detected using the biosensor. No sample pretreatment before the extraction, except centrifugation, is made. Due to the high selectivity both in the extraction and in the detection steps and to the fact that the demands on the chromatographic separation are low, a quick separation using an eluent with a low concentration of organic modifier can be made, without affecting the biosensor response. Detection limits below the 50 microg/l level in blood plasma were obtained for the three model compounds, phenol, p-cresol and 4-chlorophenol.

Biosensing Techniques↗

Simultaneous determination of cross-reactive leukotrienes in biological matrices using on-line liquid chromatography immunochemical detection.

Sulfidopeptide leukotrienes, which are important biomarkers for several diseases, are commonly measured by microtiter plate immunoassays. These immunoassays, however, cannot distinguish between several structurally similar leukotrienes and their cross-reactive metabolites and, therefore, need extensive sample handling and fractionation by means of liquid chromatography (LC). This paper describes the development and automation of a continuous-flow immunochemical detection (ICD) system and its subsequent on-line coupling to LC. The on-line LC-ICD system based on fluorescence-labeled leukotriene E4 (LTE4) was used to determine sulfidopeptide leukotrienes and their cross-reactive metabolites in a single run. Furthermore, biological matrices, e.g., urine and human cell extracts, were analyzed, the only sample pretreatment being on-line solid-phase extraction (SPE) on a novel RP-C4 restricted-access support. The determination limit of LTE4 in urine was 0.2 ng/mL (800 fmol; injection volume, 2000 microL; signal-to-noise ratio, 10). The system was linear from 0.2 to 1.0 ng/mL LTE4. Using nonlinear curve-fitting, the range could be expanded to 2.5 ng/mL. It is shown that, besides quantitation of known analytes, on-line LC-ICD is useful in the discovery of cross-reactive LTE4 metabolites.

Antigen-Antibody Reactions↗

Enzyme-based biosensor as a selective detection unit in column liquid chromatography.

A reagentless enzyme electrode based on co-immobilized alcohol oxidase and horseradish peroxidase was used as the working electrode in an amperometric flow-through cell connected to a column liquid chromatographic (CLC) system for the selective detection of methanol and ethanol. The enzymes were covalently immobilized in carbon paste (graphite-phenylmethylsilicone oil) in the presence of polyethylenimine. Electrodes prepared from the enzyme-modified carbon paste were optimized with respect to their sensitivity and selectivity. Different membranes were cast or electropolymerized directly on the surface of the electrode to increase the long-term stability of the biosensor. The compatibility with the reversed-phase chromatographic system was established. A PLRP-S polymer-based separation column was used with phosphate buffer as the mobile phase. The selectivity of the enzyme electrode was also determined by injecting some easily oxidizable and possibly interfering species normally present in biological samples. The enzyme electrode was also used in an on-line system, consisting of a microdialysis probe as the sampling unit, the CLC system and the biosensor detection device, for the selective following of the ethanol produced when a paper pulp industrial waste water was fermented with Saccharomyces cerevisiae.

Biosensing Techniques↗

Optimization of enzyme ratios in a coimmobilized enzyme reactor for the analysis of D-xylose and D-xylulose in a flow system.

A coupled enzyme system for the detection of D-xylose and D-xylulose is presented. The system is based on three consecutive enzymatic steps. The enzymes xylose isomerase (XI), mutarotase (MT), and glucose dehydrogenase (GDH) are coimmobilized on controlled pore glass and packed in a bed reactor. The relative amount of enzymes, i.e., enzyme ratio, plays a critical role in driving the overall reaction, resulting in a system with linear response characteristics and an operational range of several orders of magnitude. Three different enzyme ratios are assayed to achieve maximum conversion efficiencies for xylose and xylulose. The highest enzyme unit ratio assayed, 13.4 of GDH to XI, gave the highest apparent pseudo-first-order rate constant showing the importance of the last enzymatic reaction in the coupled system to make the overall reaction thermodynamically favorable. A pH of 7.0 was found to be an optimum compromise for the multienzyme system. Sensitivity was dependent on NAD+ concentration. The study was carried out in a flow injection system. The optimized reactor has been applied for the catalytic detection of pentoses in flow injection analysis (FIA) and liquid chromatography (LC).

Aldose-Ketose Isomerases↗

A reagentless amperometric biosensor for alcohol detection in column liquid chromatography based on co-immobilized peroxidase and alcohol oxidase in carbon paste.

A reagentless carbon paste electrode chemically modified with covalently bound alcohol oxidase and horse-radish peroxidase was examined as a selective sensor in flow injection and column liquid chromatography. A combination of carbodiimide, glutaraldehyde, and polyethyleneimine was used for immobilizing the enzymes in the paste. The surface of the electrodes was protected by first forming a layer of electropolymerized ortho-phenylenediamine followed by deposition of a cation exchange membrane (Eastman AQ 29D). The electrodes were used for detection of hydrogen peroxide, methanol, ethanol, propanol, isopropanol, and butanol. Preliminary investigations of the use of this sensor for bioprocess control are reported.

Alcohol Oxidoreductases↗

Study of a reagent- and mediator-less biosensor for D-amino acids based on co-immobilized D-amino acid oxidase and peroxidase in carbon paste electrodes.

A biosensor for the analysis of D-amino acids is described. Carbon paste (graphite/paraffin oil) was chemically modified with immobilized D-amino acid oxidase and either horse-radish peroxidase or fungal peroxidase from Arthromyces ramosus. The two enzymes dissolved in buffer, together with an amine containing oligomer or polymer, were adsorbed on dry graphite. Prior to immobilization, the graphite was heat treated at 700 degrees C for 15 s to promote an efficient electron transfer between graphite and the peroxidase. The mixture was dried before addition of the pasting liquid. The sensor is based on the fact that the hydrogen peroxide produced by the action of D-amino acid oxidase is electrocatalytically reduced through the action of the peroxidase. The amine containing compound acted as a stabilizer and activator of the enzymes in the paste. The enzyme electrode was investigated as a sensor for D-phenylalanine and hydrogen peroxide in a flow through electrochemical cell connected to a single line flow injection system. The influences on the response by different additives to the paste and pH are reported. Linear calibration curves were obtained between 0.1 and 1.4 mM for D-phenylalanine and 5 and 1000 microM for hydrogen peroxide at an applied potential of -50 mV vs. Ag/AgCl. The sensor was also active for the following D-amino acids: D-alanine, D-valine, D-leucine, D-isoleucine, D-serine, D-aspartic acid, D-glutamic acid, D-lysine, D-histidine, D-arginine, D-tryptophan, D-methionine, and D-proline.

Amino Acids↗