Search PubMedSearch

Biomedical subjects

G Marcondes

Publications and source records attributed to G Marcondes.

3 recordsLinked to original sources

High-frequency electrocardiography: an evaluation of lead placement and measurements.

Before there is widespread clinical application of the high-frequency ECG, differences resulting from the leads used and the measurement criteria for late potentials must be resolved. Therefore 113 consecutive patients without resting QRS conduction abnormalities referred for Holter monitoring were studied. Four different lead systems were used: a standard bipolar orthogonal lead system and three bipolar lead systems mapping the left ventricle. Measurements made of late potentials included normal and high-frequency QRS duration, their difference, the duration of low-amplitude signals (less than 40 uV) in the terminal QRS, and the root mean square of the last 40 msec of the high-frequency QRS duration. We found that the left ventricular leads tended to give more abnormal measurements than the orthogonal system and that the various measurements failed to agree with each other. In addition, even in this population in which abnormalities of QRS conduction were excluded, the late potential measurements tended to be more abnormal as QRS duration lengthened. These differences in lead systems and measurement criteria must be considered when clinically applying information regarding late potentials measured from the high-frequency ECG.

Adult

Factors affecting sensitivity and specificity of a diagnostic test: the exercise thallium scintigram.

Technical and methodological factors might affect the reported accuracies of diagnostic tests. To assess their influence on the accuracy of exercise thallium scintigraphy, the medical literature (1977 to 1986) was non-selectively searched and meta-analysis was applied to the 56 publications thus retrieved. These were analyzed for year of publication, sex and mean age of patients, percentage of patients with angina pectoris, percentage of patients with prior myocardial infarction, percentage of patients taking beta-blocking medications, and for angiographic referral (workup) bias, blinding of tests, and technical factors. The percentage of patients with myocardial infarction had the highest correlation with sensitivity (0.45, p = 0.0007). Only the inclusion of subjects with prior infarction and the percentage of men in the study group were independently and significantly (p less than 0.05) related to test sensitivity. Both the presence of workup bias and publication year adversely affected specificity (p less than 0.05). Of these two factors, publication year had the strongest association by stepwise linear regression. This analysis suggests that the reported sensitivity of thallium scintigraphy is higher and the specificity lower than that expected in clinical practice because of the presence of workup bias and the inappropriate inclusion of post-infarct patients.

Adult

Methodologic problems in exercise testing research. Are we solving them?

To evaluate the comparative effects of methodologic factors on the reported accuracies of two standard exercise tests, 56 publications comparing the exercise thallium scintigram with the coronary angiogram were analyzed for conformation to five methodologic standards. Analyzed were adequate definition of study group, avoidance of a limited challenge group, avoidance of workup bias, and blinded analysis of the coronary angiogram and myocardial scintigram. Study group characteristics and technical factors were also reviewed. Better conformation with methodologic standards was found than has been reported previously for treadmill exercise testing. Furthermore, study group characteristics and technical factors were better predictors of sensitivity and specificity than were methodologic deficiencies. Only workup bias and test blinding were significantly associated with test accuracy. The percentage of patients with previous myocardial infarction had the highest correlation and was independently and directly related to sensitivity and inversely related to specificity.

Coronary Angiography