Search PubMedSearch

Biomedical subjects

G M Lawrie

Publications and source records attributed to G M Lawrie.

At least 19 recordsLinked to original sources

Acute impairment of coronary blood flow by dynamic cardiomyoplasty.

The aim of this study was to quantify the effects of three different configurations of cardiomyoplasty on coronary blood flow in an acute dog model. Thirteen dogs had both latissimus dorsi muscles harvested and transposed to the chest. Coronary blood flow was measured using Doppler cuff probes on the left anterior descending and circumflex coronary arteries during each of three cardiomyoplasty configurations: left posterior, right anterior, and double. Multiple beat measures were made of systolic and diastolic flow during a control protocol and a subsequent protocol with the muscle(s) paced. Significant flow reductions during pacing were observed in the left anterior descending coronary artery during left posterior (17%, p = 0.003), right anterior (29%, p < 0.0001), and double (35%, p = 0.0001) myoplasty. Similar reductions occurred in the circumflex artery (14%, p = 0.0009; 20%, p = 0.001; 27%, p = 0.0053). The net flow over an entire pacing cycle also was reduced significantly: left anterior descending artery (11%, p = 0.0035; 23%, p = 0.0001; 23%, p = 0.0047) and circumflex artery (10%, p = 0.0025; 17%, p = 0.0018; 21%, p = 0.0091). Thus, in the acute setting cardiomyoplasty depresses coronary blood flow. A chronic setting will be needed to determine the ultimate significance of these results.

Animals

Evolution of surgical techniques for aneurysms of the descending thoracic aorta: twenty-nine years experience with 659 patients.

Between 1953 and 1993, 659 patients underwent descending thoracic aneurysm resection. The most common etiology was atherosclerosis. Pain was the main presenting symptom. Perioperative mortality fell from 24.2% between 1953 and 1964 to 14.3% between 1970 and 1993. Paraplegia occurred in 4.1% (27/659) patients overall and was little affected by time of operation or use of atriofemoral bypass. Paraparesis occurred in 5.9% (39/659) patients and was reduced by use of atriofemoral bypass. The low rate of paraparesis in the earlier experience was offset by the higher perioperative mortality from hemorrhage, attributable to the use of systemic heparin. The use of heparin-free circuits with centrifugal pumps should be considered in patients likely to have a clamp time greater than 30 minutes. The major source of perioperative morbidity and mortality was cardiac causes (48%) followed by perioperative hemorrhage (14.4%), pulmonary complications (14.4%), and rupture of another aneurysmal segment (12.0%). Late mortality occurred most commonly from cardiac causes (30.6% of deaths) and rupture of another aneurysm (16.3% of deaths). Improvement in results was due to general refinements of management in all areas rather than any single factor. These results indicate that complete preoperative assessment of the patient and the entire aorta is essential and that regular life-long follow-up is critical in order to avoid unnecessary morbidity and mortality from cardiac, cerebrovascular, or subsequent aneurysmal complications.

Aortic Aneurysm, Thoracic

Automatic implantable cardioverter defibrillator: surgical approaches for implantation.

Surgical approaches for implantation of the automatic cardioverter defibrillator are sternotomy, left thoracotomy, subxiphoid, and subcostal. Although any one of these may be combined with insertion of one or more of the electrodes transvenously, surgical entry into the chest is required for every noninvestigational defibrillator implantation operation. The approaches differ in exposure provided for selecting electrode sites and for handling untoward events, in amount and location of tissue that must be divided or dissected, and in average time required. The operation is an electrical one. Its purpose is to obtain reliable rhythm sensing so that defibrillation or cardioversion shocks will occur only when necessary, and to obtain low enough defibrillation thresholds for shocks of 30 joules or less to have a 10-joule defibrillation safety margin. Many of the patients have had previous cardiac operations. They usually have low or very low ejection fractions. Intraoperative electrophysiological testing with often multiple defibrillation episodes is required. The choice of approach varies with the state of the patient, the institutional experience, and the surgeon. This article describes technique, and the advantages and disadvantages of the four approaches as used by four surgeons in four different institutions.

Defibrillators, Implantable

The automatic implantable cardioverter-defibrillator: effect of patch polarity on defibrillation threshold.

An automatic implantable cardioverter-defibrillator (AICD) was implanted in 40 patients with sudden cardiac arrest (n = 29), sustained monomorphic ventricular tachycardia (n = 10) or recurrent syncope (n = 1) who were unsuitable for direct ablative surgery or had had unsuccessful medical therapy. The effect of patch electrode polarity on the defibrillation threshold was prospectively evaluated. Two large epicardial patches were used. Initial polarity was selected at random. Ventricular fibrillation was induced by direct current and a preestablished defibrillation protocol employed to assess the minimal energy that would reproducibly defibrillate the heart. Nineteen patients had a lower defibrillation threshold with the inferior left ventricular patch as an anode and nine patients had a lower defibrillation threshold with this patch as a cathode. In general, the defibrillation threshold was lower when this patch was used as an anode than when it was used as a cathode (18 +/- 10 versus 22.6 +/- 12.2 J; p less than 0.01). No preoperative variable predicted optimal polarity. Therefore, the effect of patch polarity on defibrillation threshold should be assessed in each patient at the time of AICD implantation so that the safety margin for satisfactory device function can be maximized.

Aged

Late results of the left subcostal approach for automatic implantable cardioverter defibrillator implantation.

A left subcostal surgical approach was used to implant an automatic implantable cardioverter defibrillator (AICD) in 48 patients with a history of nonfatal cardiac arrest or documented ventricular tachycardia/fibrillation. Electrophysiologic studies before surgery yielded induction of monomorphic or polymorphic ventricular tachycardia in 40 patients, whereas 8 were noninducible. Mean (+/- standard deviation) age was 58 +/- 12 years. Mean ejection fraction was 33 +/- 16%. Thirty patients (63%) had documented coronary artery disease; 14 patients (29%) had previous coronary bypass surgery. The mean intraoperative defibrillation threshold was 13.8 +/- 6.6 J. In 6 patients, an adjunctive right minithoracotomy was used to position 1 patch over the right atrium and thus optimize the defibrillation threshold. Patients with prior exposure to amiodarone and previous coronary bypass surgery had higher defibrillation thresholds at implantation. Two perioperative deaths occurred. There were no infections. Long-term follow-up yielded a 1- and 5-year survival of 0.88 and 0.58, respectively, and a freedom from sudden cardiac death of 1.0 and 0.97, respectively. The nonthoracotomy, left subcostal surgical approach is safe and effective, provides adequate defibrillation thresholds in most patients, and yields long-term survival comparable to other implantation techniques.

Cardiac Pacing, Artificial

Long-term results of coronary bypass surgery. Analysis of 1698 patients followed 15 to 20 years.

Between 1968 and 1975, 1698 patients underwent coronary artery bypass with autogenous saphenous vein and were followed for up to 20 years. Age at operation was 53.9 +/- 8.4 years, and 1485 were men (88%). Angina was present in 1637 patients (96%). There was single-vessel disease in 306 patients (18%), double-vessel in 642 (38%), triple-vessel in 550 patients (32%) and left main stenosis in 200 (12%). Preoperative left ventricular quality was good in 1185 (70%), poor in 508 (30%), and unknown in five patients. Survival at 20 years was as follows: for single-vessel disease, 40%; double-vessel, 26%; triple-vessel, 20%; and left main, 25%. At 20 years of follow-up, 67% of surviving patients were asymptomatic and 26% were improved. Antianginal drug therapy consisted of nitrates in 49% of patients and beta-blockers in 26%. Graft patency at 0 to 5 years was 633 of 780 grafts (81%); at 6 to 10 years, 415 of 606 grafts (68%); at 11 to 15 years, 271 of 449 grafts (60%); and at 16 to 20 years, 65 of 140 grafts (46%). Coronary bypass reoperation was performed in 324 patients (19%) and survival of these patients was 62% compared to 37% for nonreoperation patients (p less than 0.05). Cox analysis demonstrated that the major determinants of survival related to age at operation, extent of coronary disease, quality of ventricle, history of stroke, and preoperative congestive heart failure. At 20 years of follow-up of this early experience with coronary bypass, 76% of surviving patients had one or more patent grafts and the probability of freedom from reoperation was 0.62.

Coronary Artery Bypass

Design and implementation of a new computerized system for intraoperative cardiac mapping.

A rapid, portable, yet inexpensive and expandable computer-based system utilizing current technology has been developed from experience in the operating room. An efficient operating system well suited for surgery is defined. New technology recording arrays fabricated from multielectrode flexible Kapton strips were developed and found to be easy to use and highly reliable. Novel arrays are created easily for research or special clinical applications. The system displays all incoming data in real time and transfers 16-s epochs to disk on command. After the user defines a beat for analysis, the computer determines the activation time for each channel, rejects unsatisfactory channels, and displays the results for review and modification before plotting the isochronal map on the monitor. The average time to recall data and produce a map is 16 s; if manual review of 120 channels is included, mapping time is less than 4 min. Clinical data recorded during surgery are discussed. The speed and operational ease demonstrated in the operating room make this computer/electrode system valuable both for surgery and for elucidating basic mechanisms of arrhythmias.

Algorithms

Factors predictive of results of direct ablative operations for drug-refractory ventricular tachycardia. Analysis of 80 patients.

During a 9-year period 80 patients with drug-resistant sustained ventricular tachycardia underwent direct surgical ablation of arrhythmogenic myocardium. Sixty-nine were male (86%) and 11 female (14%), with 1.9 +/- 1.1 (standard deviation) ventricular tachycardia morphologies per patient. The mean number of drugs failed was 3.7 +/- 1.6 per patient. The preoperative left ventricular ejection fraction was 36.4% +/- 14.4%. Complete preoperative endocardial mapping data (greater than 4 endocardial sites in each ventricular tachycardia) were available for 60 of the 80 patients (75%) and intraoperative endocardial data in the clinical ventricular tachycardia was obtained in 37 (46.3%) of the patients. In 17 patients mapped intraoperatively by computer-assisted techniques, complete epicardial and endocardial data in the clinical ventricular tachycardia were obtained in 14 patients (82.4%). Overall, 73 of 80 (91.3%) had some mapping data available. Hospital mortality occurred in 10 patients (12.5%) at a mean interval of 13.5 days, range 0 to 62 days. Postoperatively the clinical ventricular tachycardia has not recurred in 65 of 70 surviving patients (92.9%). Nonclinical ventricular tachycardia occurred in another four patients. All nine patients with postoperative ventricular tachycardia responded to drugs. The major factors predictive of hospital mortality were prolonged cardiopulmonary bypass (greater than 150 minutes), preoperative ejection fraction less than 31%, and incomplete preoperative mapping. Hospital mortality in patients with an ejection fraction below 31% was significantly associated with a history of amiodarone usage. At 3 years of follow-up, freedom from sudden cardiac death was 95.7%, and 86.7% of patients were free of ventricular tachycardia on no antiarrhythmic drugs. These results suggest that direct ventricular tachycardia operations are an effective form of therapy for patients with sustained monomorphic ventricular tachycardia.

Adult

Endothelium-dependent relaxation in human saphenous vein grafts. Effects of preparation and clinicopathologic correlations.

Activity of endothelium-dependent relaxation factor (EDRF) was measured in 139 open ring preparations of fresh human saphenous vein from 85 patients undergoing coronary bypass grafting. The veins were constricted with phenylephrine and relaxed with the EDRF-dependent agents calcium ionophore A23187 or acetylcholine. EDRF activity produced a 36% +/- 4% relaxation of baseline contraction in response to calcium A23187. Vein graft preparation with room-temperature heparinized normal saline and pressurization to 400 mm Hg caused EDRF relaxation to fall to 10.6% +/- 2.0% versus 32.4% +/- 3.4% for control segments (p less than 0.05). Storage alone in room-temperature saline reduced EDRF response to 17.4% +/- 3.9% versus a control of 29.6% +/- 4.7% (p less than 0.05). Storage in heparinized room-temperature blood produced relaxation of 31.4% +/- 4.3% versus 34.1% +/- 5.7% (p less than 0.05). Storage in Plasma-Lyte solution (Travenol Laboratories, Inc., Deerfield, Ill), produced relaxation of 28.4% +/- 6.3% versus 30.1% +/- 5.3% (control) (p greater than 0.05). Veins stored at 2 degrees to 4 degrees C had severe depression of EDRF: 18.2% +/- 4.0% versus 34.0% +/- 5.4% for 37 degrees C storage (p less than 0.05). Pressurization to 400 mm Hg lessened EDRF relaxation: 20% +/- 3% versus 34% +/- 4% (control) (p less than 0.05), and use of nitroglycerin, papaverine, or verapamil produced no improvement. Twenty-eight vein grafts prepared with Plasma-Lyte solution were obtained from 12 patients who died 11.6 days (range up to 66 days) after operation. When compared with control veins prepared with saline and obtained at similar intervals, they had significantly more intact endothelium, less subintimal cellular infiltration, less fibrin deposition, fewer medial inflammatory changes, and less necrosis. Thus EDRF activity is significantly affected by vein graft preparation. Changes in technique to preserve EDRF produced better graft morphology early after operation.

Aged

Renovascular reconstruction: factors affecting long-term prognosis in 919 patients followed up to 31 years.

During the 31-year period from May 3, 1955, to May 12, 1986, renovascular reconstructions were performed on 919 patients. The mean age of the 529 men was 54 +/- 0.58 (SE) years and, of the 390 women, 48 +/- 0.7 years. Mean preoperative diastolic blood pressure was 110 +/- 0.6 mm Hg. The most common causes of renal artery stenosis were atherosclerosis in 647 patients, fibromuscular disease in 161 patients, and renal artery aneurysm in 51 patients. In the remaining 60 patients, other causes were present, including kinks and fibrous bands. The most common surgical procedures were Dacron bypass graft (780 arteries) and endarterectomy with or without a patch graft (329 arteries). Four hundred sixty-nine patients had associated operations, the most common of which were abdominal aortic aneurysmectomy in 231 and aortoiliofemoral reconstruction in 141 patients. The perioperative mortality rate was 5.5% (51 of 919 overall); for renal procedures alone, it was 1.7% (8 of 450) and for combined surgical procedures, 9.2% (43 of 469). The overall graft patency rate at a follow-up of 18.8 +/- 1.9 months was 88.6% (381 of 430) and at a second follow-up of 50 +/- 4.3 months, 86.7% (111 of 128). Analysis of long-term blood pressure response and factors affecting late survival indicated that patients with preoperative diastolic pressures of greater than 100 mm Hg and renal artery stenosis of greater than 70% had the best blood pressure responses and that male sex, increasing age, bilateral renal stenosis, and associated vascular operations lowered the survival rate whereas fibromuscular disease enhanced the duration of survival.(ABSTRACT TRUNCATED AT 250 WORDS)

Age Factors

Right mini-thoracotomy: an adjunct to left subcostal automatic implantable cardioverter defibrillator implantation.

High defibrillation thresholds are encountered in some patients during implantation of the automatic implantable cardioverter defibrillator (AICD). In a consecutive series of 52 patients with AICD implants, 46 had allepicardial implants by left subcostal thoracotomy, and 8 of these patients had thresholds greater than 30 J. Placement of an apicolateral large left ventricular patch and an extrapericardial large right atrial patch electrode through a limited right thoracotomy produced substantial reduction in their thresholds. Especially in patients who have had previous intrapericardial operations, this technique provides a simple solution to the problem of high thresholds.

Electric Countershock

The St. Jude valve prosthesis: analysis of the clinical results in 815 implants and the need for systemic anticoagulation.

Between July 1979 and December 1984, 785 patients received 815 St. Jude Medical valve prostheses. Valve-related mortality in the follow-up period was due to thromboembolism in seven cases, anticoagulant-related hemorrhage in three and perivalvular leak in two. Freedom from valve-related death or reoperation at 3 years was 96.4% for aortic valve replacement and 98.3% for mitral valve replacement. The overall rate of thromboembolism was 2.6%/patient-year with warfarin, 9.2%/patient-year with antiplatelet medication and 15.6%/patient-year in patients with no anticoagulant therapy. One episode of thrombotic obstruction of a mitral valve, in a patient receiving no anticoagulant therapy, resulted in an occurrence rate of such obstruction of 0.22%/patient-year. Valve replacement with the St. Jude valve produced excellent clinical results, but long-term anticoagulation with warfarin was required to minimize thromboembolic complications. The use of antiplatelet agents alone provided inadequate protection.

Adolescent

Results of direct surgical ablation of ventricular tachycardia not due to ischemic heart disease.

Surgical treatment of sustained ventricular tachycardia due to nonischemic causes is uncommon. Nonischemic ventricular tachycardia was treated in 14 patients by map-directed surgical ablation of an arrhythmogenic site. There were 9 male and 5 female patients. The mean age was 33 +/- 13.4 years (range, 15 to 57 years). The etiology was idiopathic in 4 patients, cardiomyopathy in 3, acute myocarditis in 1, arrhythmogenic right ventricular dysplasia in 2, tumor in 1, postoperative Tetralogy of Fallot in 2, and acute bacterial endocarditis in 1. Pre- and/or intraoperative electrophysiologic mapping was achieved in 13 of 14 patients. A variety of operations were performed without death. Two late deaths have occurred, neither of them, however, from arrhythmias. After operation two patients had recurrent arrhythmias. Surgery for nonischemic ventricular tachycardia is safe and effective and should be considered early in the course of these mostly young patients.

Adolescent

Transannular cryoablation of ventricular tachycardia. Surgical technique and results.

Intraoperative mapping and cryoablation of ventricular tachycardia was achieved without ventriculotomy in seven patients, who are a subgroup of the 80 patients undergoing map-directed ablation of ventricular tachycardia over a 9-year period. There were four male and three female patients. Their mean age was 53.6 +/- 24.1 years. Coronary artery disease was present in five patients, and two patients had idiopathic ventricular tachycardia. The mean preoperative ejection fraction was 42.4% +/- 13.6%. The mean number of ventricular tachycardia morphologies was 1.7 (range 1 to 3). Epicardial mapping was obtained intraoperatively in all seven patients and endocardial data in five of seven patients (71.4%). There were no hospital deaths and no early or late spontaneous recurrence of clinical monomorphic ventricular tachycardia. Nonclinical monomorphic ventricular tachycardia was inducible in two patients postoperatively and both were treated with procainamide. Death occurred late after operation in two patients: One death was related to recurrent nonclinical VT at 8 months and one at 3 months was due to carcinoma of the stomach. These results suggest that the transannular approach is feasible in selected cases, especially when computerized mapping systems with endocardial balloon electrode arrays can be used.

Adolescent