Search PubMed⌕ Search

Biomedical subjects

G Li

Publications and source records attributed to G Li.

At least 73 records · Page 4Linked to original sources

Observation of the decay psi(2S)-->K0SK0L.

The decay psi(2S)-->K(0)(S)K(0)(L) is observed using psi(2S) data collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider; the branching fraction is determined to be B(psi(2S)-->K(0)(S)K(0)(L))=(5.24+/-0.47+/-0.48)x10(-5). Compared with J/psi-->K(0)(S)K(0)(L), the psi(2S) branching fraction is enhanced relative to the prediction of the perturbative QCD "12%" rule. The result, together with the branching fractions of psi(2S) decays to other pseudoscalar meson pairs (pi(+)pi(-) and K+K-), is used to investigate the relative phase between the three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.

Journal Article↗

Non-invasive estimation of myocardial infarction by means of a heart-model-based imaging approach: a simulation study.

In the study, a new myocardial infarction (MI) estimation method was developed for estimating MI in the three-dimensional myocardium by means of a heart-model-based inverse approach. The site and size of MI are estimated from body surface electrocardiograms by minimising multiple objective functions of the measured body surface potential maps (BSPMs) and the heart-model-generated BSPMs. Computer simulations were conducted to evaluate the performance of the developed method, using a single-site MI and dual-site MI protocols. The simulation results show that, for the single-site MI, the averaged spatial distance (SD) between the weighting centres of the 'true' and estimated MIs, and the averaged relative error (RE) between the numbers of the 'true' and estimated infarcted units are 3.0 +/- 0.6/3.6 +/- 0.6 mm and 0.11 +/- 0.02/0.14 +/- 0.02, respectively, when 5 microV/10 microV Gaussian white noise was added to the body surface potentials. For the dual-site MI, the averaged SD between the weighting centres of the 'true' and estimated MIs, and the averaged RE between the numbers of the 'true' and estimated infarcted units are 3.8 +/- 0.7/3.9 +/- 0.7mm and 0.12 +/- 0.02/0.14 +/- 0.03, respectively, when 5 microV/10 microV Gaussian white noise was added to the body surface potentials. The simulation results suggest the feasibility of applying the heart-model-based imaging approach to the estimation of myocardial infarction from body surface potentials.

Body Surface Potential Mapping↗

Biological functions of the ING family tumor suppressors.

Early studies of the inhibitor of growth 1 ( ING1) gene, the founding member of the ING tumor suppressor family, demonstrated that this gene plays an important role in apoptosis and cellular senescence. Four other related genes have since been identified and found to be involved in various biological activities, including cell cycle arrest, regulation of gene transcription, DNA repair and apoptosis. The biochemical functions of ING proteins as histone acetyltransferases and histone deacetylase co-factors ties this new tumor suppressor family to the regulation of transcription, cell cycle check-points, DNA repair and apoptosis. This review is aimed at summarizing the known biological functions of the ING tumor suppressors and the signalling pathways that they involve.

Acetylation↗

Biological performance of a novel synthetic furanone-based antimicrobial.

Infection of medical devices causes significant morbidity and mortality and considerable research effort has been directed at solving this problem. The aim of this study was to assess the biological performance of a novel furanone compound that has potential as an anti-infective coating for medical devices. This study examined in vitro leukocyte response following exposure to the antibacterial 3-(1'-bromohexyl)-5-dibromomethylene-2(5H)-furanone and assessed the tissue response following subcutaneous implantation of the furanone compound covalently bound to polystyrene (PS). Peripheral human blood was exposed to furanones in solution for 1h and flow cytometry used to analyse viability and changes in expression of surface receptors CD11b/CD18 and CD44. Flow cytometry results from propidium iodide stained cell suspensions suggested that the leukocytes were viable after exposure to furanones in whole blood. No significant difference was found in the expression of CD11b/CD18 and CD44 between the furanone exposed samples and the negative control for neutrophils suggesting that the furanones themselves do not activate these leukocytes. The positive control lipopolysaccharide significantly up-regulated CD11b/CD18 and slightly down-regulated CD44 on both PMNs and monocytes. In vivo studies of the tissue response to furanone covalently bound to PS showed that there was no significant difference in cellularity of capsules surrounding the disk and no significant increase in myeloperoxidase expression. These results demonstrate negligible acute inflammatory response to synthetic brominated antibacterial furanones. Future studies will focus on chronic responses and examination of in vivo efficacy.

Animals↗

Effect of the posterior cruciate ligament on posterior stability of the knee in high flexion.

Most biomechanical studies of the knee have focused on knee flexion angles between 0 degrees and 120 degrees. The posterior cruciate ligament (PCL) has been shown to constrain posterior laxity of the knee in this range of flexion. However, little is known about PCL function in higher flexion angles (greater than 120 degrees ). This in vitro study examined knee kinematics before and after cutting the PCL at high flexion under a posterior tibial load and various muscle loads. The results demonstrated that although the PCL plays an important role in constraining posterior tibial translation at low flexion angles, the PCL had little effect in constraining tibial translation at 150 degrees of flexion under the applied loads.

Aged↗

Sensitivity of the knee joint kinematics calculation to selection of flexion axes.

Various flexion axes have been used in the literature to describe knee joint kinematics. This study measured the passive knee kinematics of six cadaveric human knee specimens using two widely accepted flexion axes; transepicondylar axis and the geometric center axis. These two axes were found to form an angle of 4.0 degrees +/- 0.8 degrees. The tibial rotation calculated using the transepicondylar axis was significantly different than the rotation obtained using the geometric center axis for the same knee motion. At 90 degrees of flexion, the tibial rotation obtained using the transepicondylar axis was 4.8 degrees +/- 9.4 degrees whereas the rotation recorded using the geometric center axis at the same flexion angle was 13.8 degrees +/- 10.2 degrees. At 150 degrees of knee flexion, the rotations obtained from the transepicondylar and the geometric center axes were 7.2 degrees +/- 5.7 degrees and 19.9 degrees +/- 6.9 degrees, respectively. The data suggest that a clear definition of the flexion axis is necessary when reporting knee joint kinematics.

Biomechanical Phenomena↗

The effect of tibiofemoral joint kinematics on patellofemoral contact pressures under simulated muscle loads.

Altered patellofemoral joint contact pressures are thought to contribute to patellofemoral joint symptoms. However, little is known about the relationship between tibiofemoral joint kinematics and patellofemoral joint contact pressures. The objective of this paper was to investigate the effect of tibiofemoral joint kinematics on patellofemoral joint pressures using an established in vitro robotic testing experimental setup. Eight cadaveric knee specimens were tested at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of flexion under an isolated quadriceps load of 400 N and a combined quadriceps/hamstrings load of 400 N/200 N. Tibiofemoral joint kinematics were measured by the robot and contact pressures by a TekScan pressure sensor. The isolated quadriceps loading caused anterior translation and internal rotation of the tibia up to 60 degrees of flexion and posterior translation and external rotation of the tibia beyond 60 degrees. The co-contraction of the hamstring muscles caused a posterior translation and external rotation of the tibia relative to the motion of the tibia under the quadriceps load. Correspondingly, the contact pressures were elevated significantly at all flexion angles. For example, at 60 degrees of flexion, the hamstrings co-contraction increased the posterior tibial translation by approximately 2.8 mm and external tibial rotation by approximately 3.6 degrees. The peak contact pressure increased from 1.4+/-0.8 to 1.7+/-1.0 MPa, a 15% increase. The elevated contact pressures after hamstrings co-contraction indicates an intrinsic relation between the tibiofemoral joint kinematics and the patellofemoral joint biomechanics. An increase in posterior tibial translation and external rotation is accompanied by an increase in contact pressure in the patellofemoral joint. These results imply that excessive strength conditioning with the hamstring muscles might not be beneficial to the patellofemoral joint. Knee pathology that causes an increase in tibial posterior translation and external rotation might contribute to degeneration of the patellofemoral joint. These results suggest that conservative treatment of posterior cruciate ligament injury should be reconsidered.

Aged↗

T-helper and T-cytotoxic cell subsets monitoring during active cytomegalovirus infection in liver transplantation.

OBJECTIVE: The objectives of this study was to analyze the peripheral blood T-lymphocyte subsets of the Th1-related versus Th2-related cytokines of CD4+ cells, and the Tc1 versus Tc2 cytokines of CD8+ cells liver transplant recipients with versus without active cytomegalovirus (CMV) infection. METHODS: Isolated peripheral blood mononuclear cells (PBMC) were stimulated using PMA/Ionomycin/Monensin. Interleukin (IL)-4 and interferon gamma (IFN-gamma) production by CD4+ and CD8+T cells were determined using fluorescence-activated cell sorter (FACS) analysis. RESULTS: The ratios of CD4/CD8 were significantly lower among active CMV-infected patients. The levels of Th2 and Tc2 cytokines (IL-4) were similar between CMV-infected and uninfected patients. However, the levels of Th1-type and Tc1-type cytokines (IFN-r) were significantly lower among active CMV-infected patients. CONCLUSIONS: Low levels of Th1-type cytokines seem to correlate with active CMV infection in liver transplant recipients.

Antigens, CD↗

2-Methoxyestardiol and bortezomib/proteasome-inhibitor overcome dexamethasone-resistance in multiple myeloma cells by modulating Heat Shock Protein-27.

Multiple myeloma (MM) remains fatal despite all available therapies. Initial treatment with conventional drugs such as, Dexamethasone (Dex) effectively induces MM cell death; however, prolonged drug exposures results in the development of chemoresistance. Our prior study demonstrated that 2-Methoxyestradiol (2ME2) induces apoptosis in multiple myeloma (MM) cells resistant to Dexamethasone (Dex). Here, we show the mechanism whereby 2ME2 overcomes Dex-resistance. The oligonucleotide array analysis demonstrates that Heat Shock Protein-27 (Hsp27) is upregulated in Dex-resistant, but not in Dex-sensitive MM cells. Proteomics analysis of Hsp27-immunocomplexes revealed the presence of actin in Dex-resistant, but not in Dex-sensitive cells. Biochemical interaction between Hsp27 and actin was examined by co-immunoprecipitation with anti-Hsp27 or actin Abs. Far western blot analysis using GST-Hsp27 fusion protein showed a direct association with actin both in vitro and in vivo. Importantly, 2ME2- or Bortezomib/Proteasome inhibitor (PS-341)-induced apoptosis in Dex-resistant MM cell lines and MM patient cells is associated with disruption of the Hsp27-actin complexes. Finally, blockade of Hsp27 by anti-sense strategy enhanced anti-MM activity of both 2ME2 and PS-341. These findings provide the clinical application of novel therapeutics targeting Hsp27 to improve patient outcome in MM.

2-Methoxyestradiol↗

Gene transfer of pro-IL-18 and IL-1beta converting enzyme cDNA induces potent antitumor effects in L1210 cells.

We report in a murine model of acute lymphoid leukemia L1210 the potent antitumor efficiency of a combinatorial delivery of pro-IL-18 gene modified L1210 (Lp18) and IL-1beta converting enzyme (ICE) gene modified L1210 (LpICE). Live leukemia cells Lp18 or Lp18 plus LpICE showed apparently reduced leukemogenicity with a survival rate of 40 or 50% at 50 days after intraperitoneal (i.p.) inoculation of a lethal dose of cells, respectively. Combination of Lp18 and LpICE was capable of inhibiting accumulation of bloody ascites, synergistically superior to Lp18 or LpICE alone. All surviving mice were rechallenged with parental L1210 cells at day 50, and all survived up to day 80, suggesting that gene-modified cells induced immune protection. Moreover, NK cytotoxicity and CTL activity were both enhanced in mice injected with Lp18, especially Lp18 plus LpICE. Levels of IFN-gamma were not altered significantly by inoculation of Lp18 or Lp18 plus LpICE. Our results demonstrate that IL-18 is a useful candidate gene in gene therapy of lymphoma or lymphoid leukemia, and ex vivo combinatorial delivery of Lp18 plus LpICE either as a single approach or as an adjunct to concomitant radiotherapy or chemotherapy, may be more efficient in a situation of minimal residual disease.

Animals↗

Generation of a polyclonal antibody specifically against the p33(ING1b) tumor suppressor.

The p33(ING1b) tumor suppressor protein plays a prominent role in cellular stress responses including cell cycle arrest, DNA repair, apoptosis, and chromatin remodeling. As the main product of the inhibitor of growth 1 (ING1) gene, p33(ING1b) is the most intensively studied protein of the ING family. So far, most ING1 antibodies have been raised against full-length proteins. Since all ING1 isoforms share an identical carboxyl-terminus, and commercially available ING1 antibodies often lack specificity, we sought to develop a polyclonal antibody capable of specifically recognizing the p33(ING1b) protein. Here, we describe the development and characterization of the p33(ING1b)-specific antibody.

Amino Acid Sequence↗

The number of cells expressing the myelin-supporting oligodendrocyte marker PLP-exon 3b remains unchanged in Wallerian degeneration.

Following spinal cord trauma there is controversy as to whether myelin-supporting oligodendrocytes at a distance from areas of spinal cord damage undergo apoptosis. To examine the response of oligodendrocytes to axon degeneration, we counted the number of oligodendrocytes and oligodendrocyte precursors in the dorsal funiculi during the course of Wallerian degeneration. Axons were disrupted at T13 and the number of labelled cells in the dorsal funiculi counted at T12, 4 days and 2, 4, and 8 weeks after injury using riboprobes to exon-3b of the PLP gene whose expression is considered to restricted to myelin-supporting oligodendrocytes, PDGFRalpha which is regarded as a marker of oligodendrocyte precursors, and MOG a marker previously used to identify myelin-supporting oligodendrocytes. We found that the number of PLP-exon-3b labelled cells remained constant during the course of Wallerian degeneration while the number of cells labelled with the riboprobes to PDGFRalpha and MOG increased. Significantly the number of MOG-positive cells was increased at times when the number of PDGFRalpha labelled cells was highest. The number of PDGFRalpha labelled cells decreased with time while the number PLP-exon-3b labelled cells remained constant. It is therefore possible that the apoptotic oligodendrocytes identified in previous studies could represent degenerating oligodendrocyte precursors or their progeny rather than degenerating myelin-supporting oligodendrocytes.

Animals↗

Estimation of parameters for a mathematical model of growth hormone secretion.

Here, we describe partial calibration of a parsimonious mathematical model of growth hormone (GH) secretion. From first principles, we derived a model of the effects on GH secretion from pituitary somatotrophs of stimulation by GH-releasing factor (GRF) or GH secretagogue, and of inhibition by somatostatin. We obtained a concise model by collapsing the many processes of the signal transduction cascade into a single step broadly reflecting the initial binding of GRF to its receptors. In the model, GH secretion is proportional to the rate of binding of GRF to activatable receptors. Desensitization occurs because of reduction of free receptors/available effector units, and resensitization occurs as those lost are replaced. This replacement is speeded up in the presence of somatostatin, which also inhibits GH secretion by reducing the constant of proportionality between the rate of GH secretion and the rate of GRF binding. We derived simple mathematical equations for the rate of GH secretion and cumulative secretion. Using these, we tested the model against data obtained from experiments performed in vitro, and made it quantitative using rigorous statistical approaches to optimize parameter estimates. The behaviour of the calibrated model matches experimental observations closely.

Algorithms↗

Evaluation of endodontic files in digital radiographs before and after employing three image processing algorithms.

OBJECTIVES: Two digital image processing algorithms, one aimed at correction for exponential attenuation and one at correction for visual response, have been developed. The aims of the present study were to test whether digital radiographs processed with these algorithms improve determination of the length of endodontic files and whether such processed radiographs are comparable with the radiographs processed with a default image processing method employed by one commercially available digital intraoral system. METHODS: A dried human skull embedded in an acrylic compound was used for exposing radiographs of the upper and lower premolars and molars with endodontic files (Kerr files size 10 and size 15) positioned to the full length of the roots or 1.5 mm short of it. Radiographs were then processed in three sets. In one set, the radiographs were processed to compensate for exponential attenuation and the response of the human visual system. In the second, the radiographs were processed with the same compensation but with an additional shift in grey levels so that the output luminance in dentin at root tips corresponds to the mean of the luminance range of a computer monitor. In the third, the radiographs were processed with the default processing method in the Sidexis program. Ten viewers evaluated all radiographs. Receiver operating characteristic (ROC) curves were obtained and areas under the curves were calculated. RESULTS: For file size 10, ROC curves for processed radiographs were higher than that for originals, while for file size 15, ROC curves for processed and original radiographs were close to each other. Significant differences were found between processed and original radiographs regarding areas under ROC curves for file size 10 but not between the differently processed radiographs. For file size 15, no significant differences were found. CONCLUSION: Radiographs processed to correct for attenuation and visual response may improve determination of the length of thin endodontic files. Such processed radiographs are comparable with the radiographs processed with the default processing method in the Sidexis program.

Algorithms↗

Perceptibility curve test for conventional and colour-coded radiographs.

OBJECTIVE: A colour scale has been developed as a complement to the grey scale in radiographs. The aim of the present study was to compare colour-coded with conventional black-and-white radiographs in terms of the perceptibility curve test. MATERIALS AND METHODS: Twelve digital radiographs were exposed on a test object from low to high exposures and recorded using the DIXI system (Planmeca Oy, Helsinki, Finland). An aluminium test object was used containing ten object details in the form of holes with depths ranging from 0.03 mm to 0.30 mm in steps of 0.03+/-0.01 mm. The new colour scale was used to transform the conventional black-and-white radiographs into colour radiographs by specially designed software. Ten observers were asked to analyse four sets of radiographs, i.e. colour-coded and black-and-white radiographs, and reversed colour-coded and reversed black-and-white radiographs. The object detail having the lowest perceptible contrast in each radiograph was registered for each observer. Perceptibility curves were plotted based on the mean value of observer data. RESULTS: Results from the perceptibility curve test showed that the information in colour-coded radiographs was at least as good as that in black-and-white radiographs. In fact, in the lower exposure range, colour-coded radiographs exhibited better perception than conventional black-and-white radiographs. CONCLUSION: Radiographs that are colour-coded with the applied colour scale may be used as an alternative to conventional black-and-white radiographs.

Absorptiometry, Photon↗

Comparison of the psychophysical properties of various intraoral film and digital systems by means of the perceptibility curve test.

OBJECTIVES: To compare psychophysical properties of two intraoral films and three digital systems using the perceptibility curve (PC) test. MATERIALS AND METHODS: A test object was used to determine the exposures and exposure differences between the total thickness of the test object and details consisting of holes of increasing depth. The PCs for the two intraoral films, UltraSpeed and EktaSpeed Plus, were constructed employing exposure and exposure differences from dose response functions. Integrals of the PCs were calculated to obtain the psychophysical properties of the two films. Psychophysical properties of the two films were compared with those of the three digital systems published previously (CDR, Dixel and Digora). RESULTS: The PC for the EktaSpeed Plus showed a slightly higher peak than that for the UltraSpeed. Available exposure ranges were comparable. The PC for the EktaSpeed Plus was shifted to the left of the exposure axis indicating its higher sensitivity as compared with UltraSpeed. All three digital systems had narrower but higher peaks compared with the films. The integrals for the digital systems were considerably larger than those for the two film types. CONCLUSIONS: All the three digital systems have superior psychophysical properties compared with the two tested films.

Absorptiometry, Photon↗

Transtomography: a new tomographic scanning technique.

OBJECTIVES: To introduce and test a new tomographic technique, namely transtomography, making it possible to expose tomographic images employing the narrow beam of an advanced panoramic machine. METHODS: The working principle of the new technique is described. It combines a translational movement with a pendular movement of the beam that creates motion unsharpness analogous to that of conventional tomography. In order to verify whether the new technique works and results in tomographic images, test radiographs were exposed on phantoms. RESULTS: The principle of transtomography works and give images with properties essentially equivalent to those of conventional tomography. With the transtomographic technique using a narrow beam, tomographic images may be exposed with an advanced panoramic machine. CONCLUSION: Transtomography may be employed to expose tomographic images basically on the same indications as for conventional tomography.

Humans↗

Psychophysical properties of a new F-speed intraoral film.

OBJECTIVES: To compare the psychophysical properties of the new Kodak InSight F-speed intraoral dental film with those for the E-speed Ektaspeed Plus film by means of the perceptibility curve (PC) test. METHODS: A specially designed test object was used. The test object was made of aluminium and was 10 mm thick. It contained ten holes, contrast details, with the same diameter of 1.5 mm but with different depths. The depths ranged from 0.03 mm to 0.30 mm in steps of 0.03 mm. The holes were placed randomly within a square area with a total of 16 possible positions. Radiographs of the test object were obtained over the full exposure ranges of the two films. A Combex DX-907 dental X-ray unit was used operating at 10 mA and two tube potentials, 70 kVp and 90 kVp. The focus-to-object distance was 50 cm. Ten observers evaluated the radiographs under uniform artificial lighting using a view box and stated the number of perceptible representations of contrast details. In order to construct perceptibility curves, absolute values of the reciprocal of the minimum perceptible logarithmic exposure differences, 1/(DeltalogE)min, were plotted as functions of the logarithm of exposures, logE, registered by the tested films. Comparisons between the two films were made separately for the two tube potentials, 70 kVp and 90 kVp. RESULTS: The results are presented graphically. PCs for the InSight film had higher peaks than those for the Ektaspeed Plus film. This indicates that the viewers were able to perceive smaller exposure differences in the former compared with the latter. PCs for the InSight film were shifted towards the left along the exposure axis relative to the PCs for the Ektaspeed Plus film indicating that the former film is more sensitive than the latter. The integrals of the PCs for InSight film were larger than those for Ektaspeed film indicating superior psychophysical properties of the InSight film. CONCLUSIONS: From the point of view of perception, the new InSight film has such psychophysical properties in comparison with Ektaspeed Plus film that it will be the more favourable of the two in clinical radiographic practice.

Absorptiometry, Photon↗