Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer: technical note.

BACKGROUND: Hemodialysis using high flux membranes today is a commonly used therapy. The primary advantage is the larger spectrum of molecules removed with these membranes, and the mechanism of removal is in part due to a phenomenon of filtration and backfiltration along the length of the hollow fibers. We hypothesized that increasing the filtration and backfiltration fluxes by modifying the structure of the dialyzer could enhance the convective transport of various solutes. METHODS: A modified high flux dialyzer was compared to the standard model in terms of pressure profiles, filtration-backfiltration rates and solute clearances. The modification consisted on the placement of a O-ring around the fiber bundle to create a resistance for the flow of the dialysis solution external to the fibers. The study on filtration fluxes was carried out using a scintigraphic method previously described, and solute clearances were studied during ultrafiltration-controlled hemodialysis sessions. RESULTS: Utilizing a net filtration condition proximal to zero, the rates of proximal filtration and distal backfiltration in the experimental dialyzer were significantly enhanced in comparison with the standard dialyzer. The pressure drop in the dialysate compartment could be increased significantly, thus permitting an increase in the positive transmembrane pressure in the first half of the dialyzer and a parallel increase in the negative transmembrane pressure in the second half of the dialyzer. This resulted in a significant enhancement of the convective transport of middle-large solutes as demonstrated by the increase in vitamin B12 and inulin clearances. CONCLUSIONS: This approach suggests that changes in design of the dialyzer may affect its performance. The use of internal filtration is suggested to improve convection and dialyzer efficiency for larger solutes without the requirement for high volumes of replacement fluid, as is the case for current hemodiafiltration techniques.

Hemodiafiltration↗

Randomized long-term evaluation of bicarbonate-buffered CAPD solution.

BACKGROUND: Over the past 15 years, lactate has been used successfully as a buffer in peritoneal dialysis solutions, although its effectiveness in the correction of uremic acidosis and its biocompatibility on peritoneal resident cells have been questioned. In addition, some investigators have suggested other potential adverse metabolic effects resulting from the unphysiologically high lactate flux into the body during CAPD. These potential problems associated with lactate-containing CAPD solution prompted the search for alternative buffer-containing solutions. Bicarbonate, the physiological buffer, was considered when the problem of calcium and magnesium carbonate solubility was solved by the use of a two-compartment bag system, allowing the mixing of bicarbonate and divalent cations immediately before infusion. The long-term tolerance, safety, efficacy and therapeutic value of a bicarbonate-buffered peritoneal dialysis solution were evaluated in this study. METHODS: This open, randomized, controlled, multicenter study comparing a 34 mmol/liter bicarbonate- with a 35 mmol/liter lactate-buffered peritoneal dialysis solution was performed in two consecutive 12-week-treatment phases. Fourteen Centers participated in this trial. RESULTS: A total of 69 out of initially 123 randomized patients completed the six-month study period (36 patients in the bicarbonate group and 33 in the lactate group). While the arterial acid base status of the total study population did not change during the study period and no significant difference was observed between the two treatment groups, the acid-base status of patients in the bicarbonate group entering the study with a metabolic acidosis significantly improved (mean +/- SD; blood pH: baseline = 7.361 +/- 0.05, week 12 = 7.380 +/- 0.04, P < 0.05; week 24 = 7.388 +/- 0.03 P < 0.05; plasma bicarbonate: baseline = 19.49 +/- 3.01 mmol/liter, week 12 = 21.16 +/- 2.63 mmol/liter, P < 0.01; week 24 = 21.51 +/- 2.42 mmol/liter, P < 0.01). No significant changes were recorded in acidotic patients treated with the conventional lactate-buffered solution. The changes in plasma bicarbonate from baseline during the study was significantly different between the groups (week 12: lactate = +0.11 +/- 2.21 mmol/liter, bicarbonate = +1.69 +/- 2.55 mmol/liter, P < 0.05, 95% confidence interval for the difference 0.21 to 2.94 mmol/liter; week 24: lactate = +0.03 +/- 2.48 mmol/liter, bicarbonate = +1.82 +/- 2. 96 mmol/liter, P < 0.05, 95% confidence interval for the difference 0.16 to 3.42 mmol/liter). The normalized protein catabolic rate (nPCR) slightly but significantly decreased in the lactate group (baseline -0.90 +/- 0.23 g/kg/day, week 24 -0.83 +/- 0.21 g/kg/day, P < 0.01) and increased in the bicarbonate group (baseline +0.89 +/- 0.28 g/kg/day, week 24 +0.92 +/- 0.26 g/kg/day, P < 0.05). Changes from baseline between groups were significant (week 24, lactate = -0. 099 +/- 0.15 g/kg/day, bicarbonate = 0.049 +/- 0.12 g/kg/day, P < 0. 01, 95% confidence interval for the difference 0.068 to 0.229 g/kg/day). Other evaluated parameters (biochemical profile, peritoneal function parameters, dialysate protein loss) did not differ significantly between the two groups. No adverse effects related to the study solution were recorded. CONCLUSIONS: These results support the efficacy and safety of bicarbonate-buffered peritoneal solutions in a controlled randomized comparison for up to six months. Peritoneal dialysis solutions containing the physiological buffer bicarbonate might effectively replace conventional lactate-buffered CAPD solutions.

Acid-Base Equilibrium↗

Colorectal follow-up planning modified on the basis of our personal experience.

BACKGROUND: The authors, evaluating the disappointing follow-up results in patients suffering from colorectal carcinoma who had undergone surgery for cure, tried a more rational follow-up. METHODS: In a retrospective review about 232 patients who adhered to the follow-up protocol, we evaluated the accuracy rates of CEA, liver ultrasonography and abdominal CT. In the same group of patients. we evaluated the type of correlation between the neoplastic recurrence rate and Astler-Coller's classification. RESULTS: (1) In detecting hepatic metastases CEA levels furnished sensitivity and negative predictive value more than liver ultrasonography (83.3 vs. 77.8% and 98.4 vs. 98%, respectively); (2) in our series, we obtained a lower recurrence rate in classes A+B1 (7.5%) and B2 (20.8%) and higher in C1+C2 (44.4%) and D (66.7%) (p < 0.0 1). CONCLUSION: According to these data we decided to eliminate postoperative liver ultrasonography and customize follow-up protocol on tumor staging and timing of cancer relapse. The authors believe that these changes will not modify the results, but cause less psychophysical stress for the patients and reduce costs by 50%.

Biomarkers, Tumor↗

Beta 2-microglobulin removal by synthetic dialysis membranes. Mechanisms and kinetics of the molecule.

Beta 2-microglobulin (beta 2-m) accumulation represents a possible complication of long term dialysis. It is therefore important to evaluate the capacity of removal of this molecule from the patient by different dialysis membranes. The present study is aimed at evaluating the mechanisms involved in beta 2-m removal by three different synthetic membranes: a) highly asymmetric hydrophobic polysulfone (Biosulfane, NMC), b) moderately asymmetric and hydrophobic polysulfone (PS600, Fresenius), c) Polyacylonitrile (AN69HF, Hospal). The adsorption capacity and sieving coefficients of the three membranes for native and labeled beta 2-m were studied in vitro utilizing human blood. The amount adsorbed by the membrane was measured by the elution of the molecule obtained with a detergent solution. Clearances, total removal and membrane adsorption were studied in six patients treated in a randomized sequence with the three membranes. For this purpose, plasma and dialysate measurements as well as total collection of spent dialysate and beta 2-m elution from the used dialyzers were carried out. Ex novo generation of beta 2-m did not take place during in vitro circulation. The molecule was removed by the studied membranes both by filtration and adsorption. The Biosulfane membrane removed beta 2-m mostly by adsorption while the PS600 membrane removed beta 2-m almost entirely by filtration. Intermediate behaviour was shown by AN69 membrane. Similar quantities of beta 2-m were removed from the patients with the three membranes. Total removal could only be precisely measured by adding the quantity of beta 2-m eluted from the membrane to the amount recovered in the spent dialysate. Out of total removal, adsorption was more than 90% with Biosulfane, while only 5% with the PS600. These findings contribute to the understanding of the discrepancy found between the clearance measured from the plasma side and that measured from the dialysate side. In conclusion, clearance and sieving measurements for beta 2-m cannot be correctly performed unless the capacity of adsorption of the membrane is taken into account.

Acrylic Resins↗

Impact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance.

A new type of dialyzer (PAN 650 SF Asahi) is analyzed in terms of hydraulic properties, solute clearances and dialysate flow distribution. The new type of dialyzer is a polyacrylonitrile hollow fiber filter, equipped with spacing filaments placed externally to the fibers to facilitate dialysate distribution and avoid channeling. The new filter is compared with a similar filter without spacing filaments. For this purpose, blood and dialysate side clearances have been measured in sequential dialysis session carried out randomly in the same patients. Furthermore, a last generation helical scanner (X-Press/HS1, Toshiba) has been utilized to analyze in vitro the flow distribution of dialysate inside the dialyzer. A contrast medium was injected and a sequence of images has been achieved on a longitudinal section of the dialyzer. This new method permits to avoid any bias due to the cylindrical shape of the dialyzer, since a 10 mm thick rectangular section is analyzed and not the entire body of the filter. The dialyzers equipped with spacing filaments displayed a significant improvement of the dialysate distribution as demonstrated by the radiological pattern. In detail, despite a channeling phenomenon in the peripherical region of the bundle is still present, this is remarkably reduced in comparison with the channelling phenomenon observed in the standard dialyzers. This improved distribution is confirmed by a significant improvement of the solute clearances.

Dialysis Solutions↗

[Therapeutic strategy in thymomas].

Between July 1989 to February 1994 eight patients with thymoma were operated in the First surgical Clinic of University of Catania; in seven the neoplasia was associated with myasthenia gravis, the severity of which was evaluated according to the Osserman's classification. The surgical treatment has been: total thymectomy in four patients, in two total and partial resection was carried out respectively, and in two a macrobiopsy was performed. The postoperative staging was carried out according to Masaoka. The neoadjuvant chemotherapy and postoperative radiation therapy have been analyzed. The authors concluded that a rigorous anatomo-surgical and histopathological classification is the best way for the right use of postoperative adjuvant therapies to reduce the incidence of local and distant recurrence of these tumors.

Adolescent↗

Favourable anatomical variation for the resection of a Klatskin tumour.

The liver and the biliary tract are rich in anatomical variations, knowledge of which is important for the surgeon. A case of an anatomical variation is reported, which allowed easy and oncologically correct resection of a Klatskin tumour. The variation consisted of abnormally long right and left extrahepatic ducts and an abnormal distal bifurcation, with a cystic duct joining the distal end of the right duct. A favourable modification of surgical strategy could be obtained by an oncologically correct resection of a Klatskin tumour avoiding a liver resection and also allowing easy reconstruction. Complete biliary exposure was necessary to reveal the rare, pre-operatively unrecognized, but favourable situation. In the absence of clear contraindications extended biliary dissection is to be recommended to avoid errors in the evaluation of the resectability of hilar biliary cancers.

Aged↗

Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. The Italian Cooperative Dialysis Study Group.

There is increasing evidence that the biochemical and cellular phenomena induced by blood/ membrane/dialysate interactions contribute to dialysis-related intradialytic and long-term complications. However, there is a lack of large, prospective, randomized trials comparing biocompatible and bioincompatible membranes, and convective and diffusive treatment modalities. The primary aim of this prospective, randomized trial was to evaluate whether the use of polysulfone membrane with bicarbonate dialysate offers any advantage (in terms of treatment tolerance, nutritional parameters and pre-treatment beta-microglobulin levels) over a traditional membrane (Cuprophan). A secondary aim was to assess whether the use of more sophisticated methods consisting of a biocompatible synthetic membrane with different hydraulic permeability at different ultrafiltration rate (high-flux hemodialysis and hemodiafiltration) offers any further advantages. Seventy-one Centers were involved and stratified according to the availability of only the first two or all four of the following techniques: Cuprophan hemodialysis (Cu-HD), low-flux polysulfone hemodialysis (LfPS-HD), high-flux polysulfone high-flux hemodialysis (HfPS-HD), and high-flux polysulfone hemodiafiltration (HfPS-HDF). The 380 eligible patients were randomized to one of the two or four treatments (132 to Cu-HD, 147 to LfPS-HD, 51 to HfPS-HD and 50 to HfPS-HDF). The follow-up was 24 months. No statistical difference was observed in the algebraic sum of the end points between bicarbonate dialysis with Cuprophan or with low-flux polysulfone, or among the four dialysis methods under evaluation. There was a significant decrease in pre-dialysis plasma beta 2-microglobulin levels in high-flux dialysis of 9.04 +/- 10.46 mg/liter (23%) and in hemodiafiltration of 6.35 +/- 12.28 mg/liter (16%), both using high-flux polysulfone membrane in comparison with Cuprophan and low-flux polysulfone membranes (P = 0.032). The significant decrease in pre-dialysis plasma beta 2-microglobulin levels could have a clinical impact when one considers that beta 2-microglobulin accumulation and amyloidosis are important long-term dialysis-related complications.

Adolescent↗