Detection of indinavir crystals in urine: dependence on method of analysis.

OBJECTIVES: To determine the frequency of crystalluria in patients treated with the human immunodeficiency virus protease inhibitor indinavir and to compare methods of detecting crystalluria. METHODS: A total of 308 freshly voided urine specimens from 168 patients treated with indinavir were evaluated by manual microscopy of sediment and microscopy with an automated workstation and by dipstick analysis. RESULTS: Crystals were detected in 22%, 31%, or 32% of specimens using, respectively, an automated workstation, manual microscopy, or both methods. Proteinuria or hemoglobinuria occurred significantly more often in specimens with (28%) than without (18%) crystals. Frequency of crystalluria was unrelated to specific gravity, but it increased at higher pH. Crystals were detected in 21% of specimens with pH less than 6 and 42% of specimens with pH of 6 or higher. CONCLUSIONS: Crystalluria occurs in more than 30% of urine specimens from patients treated with indinavir, but detection rates vary substantially with method of analysis. Manual microscopy detected crystalluria 41% more often than did an automated workstation.

Crystallization↗

Interferences with semen detection by an immunoassay for a seminal vesicle-specific antigen.

A commercial enzyme-linked immunosorbent assay (ELISA), the SEMA assay, for a seminal vesicle-specific antigen (SVSA) provides highly sensitive detection of semen. Here we show marked interference of proteins such as albumin, serum proteins, or mucin with the assay. This would substantially decrease the sensitivity for detecting semen mixed with other biological fluids such as blood or vaginal secretions.

Enzyme-Linked Immunosorbent Assay↗

Detection of azide in forensic samples by capillary electrophoresis.

Azide salts are highly toxic compounds that have been difficult to detect in forensic samples. Here, anion analysis by capillary electrophoresis with indirect spectrophotometric detection was applied to detect azide in forensic specimens from two suicide victims. Gastric specimens from the victims were shown to have high azide concentrations; azide represented one of the major anionic components and no corresponding component occurred in normal gastric juice. Samples of blood and bile had low concentrations of azide near the limits of detection. The method described for azide analysis used simple steps for sample preparation and analysis time was less than 10 min per sample. It offers a simple and reliable method for detecting azide in biological fluids.

Azides↗

Progress toward preparation of universal donor red cells.

Coupling of an inert polymer to the surface of red cells was examined as a potential means of covering blood group antigens and producing cells that could serve as universal donor cells for transfusion. Effective blockade of red cell antigens was achieved with N-hydroxysuccinimide-activated esters of polyethylene glycol. It was possible to block all antigens tested, but lower concentrations of reactants were required to block peptide-defined antigens than carbohydrate-defined antigens. Red cells remained intact after modification but were significantly damaged. Our results demonstrate the feasibility of antigenic blockade of red cells, but there is a need to reduce damage during coupling reactions to produce viable red cells.

Blood Donors↗

Analytical artifacts in hematocrit measurements by whole-blood chemistry analyzers.

Compact analyzers suited to near-patient testing estimate hematocrit by measuring the conductivity of undiluted blood. We evaluated the accuracy of hematocrit determination of one such analyzer (Instrumentation Laboratory BGE analyzer) against an automated cell counter (EPC) and packed cell volume (PCV) microhematocrit. When specimens (n = 34) from outpatient and ward patients were analyzed with all three methods, the BGE analyzer correlated well with both EPC and PCV hematocrit determinations (BGE = 1.00 PCV + 0.3%, S(y)/x = 2.0%), suggesting that all three methods are similar in performance for most patients. However, a patient with increased plasma osmolality showed significant decreases in BGE and PCV hematocrits relative to the EPC method. The differences in hematocrit measurements could be reproduced by adding solutes to blood in vitro or by modifying the plasma osmolality of rats in vivo. Samples from patients undergoing cardiac surgery, whose blood had large changes in protein concentration, showed discrepancies between hematocrits by conductivity and other methods; similar effects could be produced by changes in protein concentration or in vitro addition of polyethylene glycol. We conclude that conductivity measurements provide accurate hematocrit results for physiologically normal subjects but not for some intensive-care and surgical patients.

Animals↗

Rapid measurement of serum pancreatic amylase.

A simple, rapid assay for the pancreatic isoenzyme of human serum amylase was developed. The assay utilized an immunoabsorbent prepared by coating latex beads with a monoclonal antibody specific for pancreatic amylase. Treatment of patient serum with immunoabsorbent removed pancreatic amylase, and measurement of residual amylase activity with standard total amylase methodology allowed estimation of the pancreatic amylase content. Extraction efficiency of pancreatic amylase was consistent at amylase concentrations up to 1,000 U/L (y = 0.97 x +16.7 U/L; r = 0.9995). The assay was standardized with purified pancreatic amylase added to neonatal serum (low endogenous activity). A comparison of patient specimen results with the results of a standard technique (cellulose acetate electrophoresis) yielded an excellent correlation (immunoabsorption result = 0.96 electrophoresis result + 1.2 U/L; r = 0.987). Salivary amylase did not interfere with the assay until levels exceeded 1,000 U/L. Daily analysis of a frozen serum pool yielded a coefficient of variation of 9.2% at mean pancreatic amylase value of 54 U/L (+/- 5 U/L). A normal range study found a strong influence of age, with pancreatic amylase levels increasing dramatically in the first 3 years of life, to stabilize at a range of 0-66 U/L thereafter.

Amylases↗

Detection of autoantibodies to amylase by ELISA: comparison of detection of macroamylase and free autoantibody.

New ELISAs for detecting macroamylase or free autoantibodies to amylase were tested with 48 samples that had been characterized by gel chromatography and electrophoresis. The macroamylase ELISA, with anti-IgG or anti-IgA for detection, detected macroamylase in 28 of 33 samples known to contain macroamylase (85% sensitivity), whereas the ELISA for free autoantibody to amylase was positive for only 11 samples. Specificities of both ELISAs were 93%. Among 28 true positives detected with the macroamylase ELISA, 22 contained IgA, 3 contained IgG, and 3 contained both immunoglobulins. Detection of IgM added no true positives. ELISA responses (y) were proportional to log [macroamylase concentration by chromatography (x)] from 0 to 1200 U/L: y = 5.15 x + 1.66; r = 0.72; Sy x = 1.65. As new tools for detecting macroenzymes consisting of enzyme-autoantibody complexes, the ELISAs show that some autoantibodies are detected more sensitively as antibody-antigen complexes than as free antibody.

Amylases↗

Changes in plasma amino acid concentrations in response to HIV-1 infection.

Plasma concentrations of 21 amino acids were determined for 20 control subjects and 20 subjects infected with human immunodeficiency virus type 1 (HIV). Compared with the control subjects, the HIV-infected group had lower cystine, tryptophan, and methionine (decreased 67%, 52%, and 32%, respectively, P < 0.001 for each) and increased taurine (230%, P < 0.001) and lysine concentrations (30%, P < 0.001). Other amino acid concentrations changed modestly. Amounts of cystine, tryptophan, methionine, taurine, and lysine did not differ significantly between subgroups of HIV-infected subjects with > 200 (n = 6) or < 200 (n = 14) CD4+ lymphocytes per microliter, suggesting that the concentrations decrease soon after infection and change little thereafter. Activation of metabolism of cystine to taurine may explain reciprocal changes in these amino acids and known depletion of cystine and glutathione. The selective changes in amino acid profiles observed during HIV infection differ from those recognized for malnutrition or other pathological processes.

Acquired Immunodeficiency Syndrome↗

Interference in ionized calcium measurements by heparin salts.

We determined the suitability of various heparin salts used for anticoagulation of whole-blood specimens for measurement of ionized calcium (iCa), blood gases, and electrolytes. We were particularly interested in a new heparin product containing both zinc and lithium cations (CNLZ heparin), in which the binding sites with greatest affinity for divalent cations are bound with zinc and low-affinity sites with lithium. In initial experiments Li heparin decreased iCa concentrations 0.07 mmol/L at the lowest heparin concentration (3000 units/L) and progressively lowered them at higher concentrations. Zn heparin initially increased iCa concentrations 0.06 mmol/L but progressively lowered them as the heparin concentration was increased. Li heparin interfered even when present in amounts (9 units per 3-mL syringe) minimally effective in preventing coagulation. Use of CNLZ heparin (36 units per 3-mL syringe; Zn 63-78 g/kg of heparin) largely eliminated interference of heparin in iCa measurements. In studies that included the effects of concentration of heparin through partial filling of syringes, specimens anticoagulated with CNLZ heparin compared well with unheparinized controls in measurements of iCa, blood gases, and electrolytes. Blood gases and iCa results on CNLZ-heparinized specimens from intensive-care-unit patients also compared well with specimens anticoagulated with a preparation of heparin (EB heparin) in which calcium has been added to balance the calcium-binding capacity. However, the presence of calcium in EB heparin significantly increased measured total calcium concentrations, whereas the new CNLZ heparin did not interfere in total calcium determinations.

Arteries↗