Search PubMed⌕ Search

Biomedical subjects

G K von Schulthess

Publications and source records attributed to G K von Schulthess.

At least 19 recordsLinked to original sources

[Positron emission tomography (PET)--current state of the art and future perspectives].

Over the last years, PET has developed rapidly, with the most relevant indications being in oncologic imaging. Particularly since the introduction of PET-CT it is suggested that PET will become the imaging standard in oncologic staging and therapy monitoring in the near future in many tumors. This is due to the fact that PET measures molecular events such as glucose uptake and metabolism rather than anatomical changes. Despite this, anatomical information is frequently relevant for precise staging: hence, PET in the form of PET-CT is rapidly becoming the preferred way of imaging. In 2004, there were around 8000 PET examinations performed in Switzerland. A steady further increase is expected with around 2000 to 3000 PET examinations necessary per one million inhabitants per year. Other indications for PET are in neuro-, cardio- and inflammation imaging with substantial growth potential in all fields. The next promising clinical application of PET-CT may well be integrated PET-CT of the heart for the representation of coronary anatomy combined with quantitative myocardial perfusion as "cardiac-one-stop-shop".

Energy Metabolism↗

The value of PET, CT and in-line PET/CT in patients with gastrointestinal stromal tumours: long-term outcome of treatment with imatinib mesylate.

PURPOSE: Gastrointestinal stromal tumours (GIST) are mesenchymal neoplasms of the gastrointestinal tract that are unresponsive to standard sarcoma chemotherapy. Imaging of GIST patients is done with structural and functional methods such as contrast-enhanced helical computed tomography (ceCT) and positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG). The aim of this study was to compare the prognostic power of PET and ceCT and to evaluate the clinical role of PET/CT imaging. METHODS: All patients with GIST undergoing PET or PET/CT examinations were prospectively included in this study, and the median overall survival, time to progression and treatment duration were documented. The prognostic significance of PET and ceCT criteria of treatment response was assessed and PET/CT was compared with PET and ceCT imaging. Data for 34 patients (19 male, 15 female, 21-76 years) undergoing PET or PET/CT for staging or restaging were analysed. RESULTS: In 28 patients, PET/CT and ceCT were available after introduction of treatment with the tyrosine kinase inhibitor imatinib mesylate (Gleevec; Novartis, Basel, Switzerland). Patients without FDG uptake after the start of treatment had a better prognosis than patients with residual activity. In contrast, ceCT criteria provided insufficient prognostic power. However, more lesions were found on ceCT images than on PET images, and FDG uptake was sometimes very variable. PET/CT delineated active lesions better than did the combination of PET and ceCT imaging. CONCLUSION: Both PET and PET/CT provide important prognostic information and have an impact on clinical decision-making in GIST patients. PET/CT precisely delineates lesions and thus allows for the correct planning of surgical interventions.

Adult↗

Detection of coronary artery disease by magnetic resonance myocardial perfusion imaging with various contrast medium doses: first European multi-centre experience.

AIMS: Magnetic resonance (MR) first-pass myocardial perfusion imaging during hyperaemia detects coronary artery stenoses in humans with test sensitivity depending on contrast medium (CM)-induced signal change in myocardium. In this prospective multi-centre study, the effect of CM dose on myocardial signal change and on diagnostic performance was evaluated using a stress-only approach. METHODS AND RESULTS: Ninety-four patients with known or suspected coronary artery disease (CAD) were randomised to 0.05,0.10, or 0.15 mmol/kg body weight of an extravascular CM (Gd-DTPA) and X-ray coronary angiography was performed within 30 days prior/after the MR examination. A multi-slice MR technique with identical hardware and software in all centres was used during hyperaemia (adenosine 0.14 mg/kg/min) to monitor myocardial CM wash-in kinetics and data were analysed semi-automatically in a core laboratory. Protocol violations resulted in 80 complete studies with CAD (defined as > or =1 vessel with diameter stenosis > or =50% on quantitative coronary angiography) present in 19/29, 13/24, and 20/27 patients for doses 1, 2, and 3, respectively. In normal myocardium, the upslope increased with CM dose (overall-p<0.0001, ANOVA). For CAD detection the area under the receiver operator characteristics curve for subendocardial data (3 slices with quality score<4 representing 86% of cases) was 0.91+/-0.07 and 0.86+/-0.08 for doses 2 and 3, respectively, and was lower for dose 1 (0.53+/-0.13, p<0.01 and p<0.02 vs. doses 2 and 3, respectively). Corresponding sensitivities/specificities (95% confidence intervals) for pooled doses 2/3 were 93% (77-99%; ns vs. dose 1) and 75% (48-92%;p<0.05 vs. dose 1), respectively. CONCLUSIONS: With increasing doses of CM, a higher signal response in the myocardium was achieved and consequently this stress-only protocol, with CM doses of 0.10-0.15 mmol/kg combined with a semi-automatic analysis, yielded a high diagnostic performance for the detection of CAD.

Analysis of Variance↗

Optical imaging of the spatiotemporal dynamics of cerebral blood flow and oxidative metabolism in the rat barrel cortex.

Oxidative metabolism and cerebral blood flow (CBF) are two of the most important measures in neuroimaging. However, results from concurrent imaging of the two with high spatial and temporal resolution have never been published. We used flavoprotein autofluorescence (AF) and laser speckle imaging (LSI) in the anaesthetized rat to map oxidative metabolism and CBF in response to single vibrissa stimulation. Autofluorescence responses reflecting oxidative metabolism demonstrated a fast increase with a delay of 0.1 s. The sign-reversed speckle contrast reflecting CBF started to rise with a delay of 0.6 s and reached its maximum 1.4 s after the stimulation offset. The fractional signal changes were 2.0% in AF and 9.7% in LSI. Pixelwise modelling revealed that CBF maps spread over an area up to 2.5-times larger than metabolic maps. The results provide evidence that the increase in cerebral oxidative metabolism in response to sensory stimulation is considerably faster and more localized than the CBF response. This suggests that future developments in functional imaging concentrating on the metabolic response promise an increased spatial resolution.

Animals↗

Impact of whole body positron emission tomography on initial staging and therapy in patients with squamous cell carcinoma of the oral cavity.

The aim of this study is to evaluate the additional clinical information provided by whole body positron emission tomography (PET) with fluorodeoxyglucose (FDG) for initial staging of patients with squamous cell carcinoma (SCC) of the oral cavity. PET scans from the head to the pelvic floor of 34 consecutive patients (22 male, 12 female; mean age 71 years) with histologically confirmed SCC of the oral cavity were retrospectively evaluated. Clinical information including CT of the head and neck and chest X-Ray or chest CT was compared with information on nodal involvement and distant metastases or secondary tumours obtained with PET. The primary tumour was identified with PET in 33 of 34 patients (97%). In 27 Patients (81%) the clinical N-stage was confirmed with PET. In two Patients (6%) additional pathologic loco-regional lymph nodes were found. In five patients more lymph nodes were identified with CT. Distant lesions were seen with PET imaging in bone, lung, mediastinum, liver and colon. In three patients (6%) distant metastases were correctly identified. In another four patients (12%) a secondary cancer was detected. One false positive finding was described with PET. In five of 34 patients (15%) the additional findings as revealed with PET lead to a change of treatment. Whole body PET provides relevant additional information to a standard clinical staging procedure in patients with oral cavity SCC. The detection of distant metastases and secondary primary tumours can have a great impact on patient management.

Aged↗

Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography.

BACKGROUND: Monitoring contrast medium wash-in kinetics in hyperemic myocardium by magnetic resonance (MR) allows for the detection of stenosed coronary arteries. In this prospective study, the quality of a multislice MR approach with respect to the detection and sizing of compromised myocardium was determined and compared with positron emission tomography (PET) and quantitative coronary angiography. METHODS AND RESULTS: A total of 48 patients and healthy subjects were studied by MR using a multislice hybrid echo-planar pulse sequence for monitoring the myocardial first pass kinetics of gadolinium-diethylenetriamine pentaacetic acid bismethylamide (Omniscan; 0.1 mmol/kg injected at 3 mL/s IV) during hyperemia (dipyridamole 0.56 mg/kg). Signal intensity upslope as a measure of myocardial perfusion was calculated in 32 sectors per heart from pixelwise parametric maps in the subendocardial layer and for full wall thickness. Before coronary angiography, coronary flow reserve (hyperemia induced by dipyridamole 0.56 mg/kg) was determined in corresponding sectors by (13)N-ammonia PET. Receiver-operator characteristic analysis of subendocardial upslope data revealed a sensitivity and specificity of 91% and 94%, respectively, for the detection of coronary artery disease as defined by PET (mean coronary flow reserve minus 2SD of controls) and a sensitivity and specificity of 87% and 85%, respectively, in comparison with quantitative coronary angiography (diameter stenosis >/=50%). The number of pathological sectors per patient on PET and MR studies correlated linearly (slope, 0.94; r=0.76; P<0.0001). CONCLUSIONS: The presented MR approach reliably identifies patients with coronary artery stenoses and provides information on the amount of compromised myocardium, even when perfusion abnormalities are confined to the subendocardial layer. This modality may qualify for its clinical application in the management of coronary artery disease.

Adult↗

Tetrahydrobiopterin increases myocardial blood flow in healthy volunteers: a double-blind, placebo-controlled study.

OBJECTIVES: Tetrahydrobiopterin (BH4) is a regulatory cofactor for the activity of nitric oxide synthases. Vasodilating properties of BH4 have been reported in vitro and in vivo. The influence of BH4 on myocardial blood flow (MBF), however, is largely unknown. We therefore performed a double-blind, placebo-controlled study to investigate the effect of intravenous BH4 on MBF in healthy volunteers. METHODS AND RESULTS: Resting MBF was assessed in 15 subjects receiving either intravenous BH4 (10 mg/kg) or placebo using positron emission tomography (PET) and [13N]ammonia. From a mean baseline MBF of 0.91 +/- 0.09 ml/min/g, MBF increased to 1.18 +/- 0.10 ml/min/g after BH4 (n = 10; p = 0.0042). In contrast, in the group receiving placebo mean MBF remained unchanged (non-significant decrease from 0.97 +/- 0.19 to 0.84 +/- 0.11 ml/min/g; n = 5; p = 0.36). Systemic haemodynamics and ECGs remained unaffected in both groups. BH4 was very well tolerated. CONCLUSION: Systemically administered BH4 is safe and effectively increases resting MBF in healthy volunteers.

Adult↗

Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation.

Open magnetic resonance (MR) scanners allow MR-guided targeting of tumors, as well as temperature monitoring of radio frequency (RF) ablation. The proton frequency shift (PFS) technique, an accurate and fast imaging method for temperature quantification, was used to synthesize thermal maps after RF ablation in an open 0.5 T MR system under ex vivo and in vivo conditions. Calibration experiments with 1.5% agarose gel yielded a chemical shift factor of 0.011 +/- 0.001 ppm/ degrees C (r2 = 0.96). Three gradient echo (GRE) pulse sequences were tested for thermal mapping by comparison with fiberoptic thermometer (Luxtron Model 760) readings. Temperature uncertainty decreased from high to low bandwidths (BW): +/-5.9 degrees C at BW = 15.6 kHz, +/-1.4 degrees C at BW = 3.9 kHz, and +/-0.8 degrees C at BW = 2.5 kHz. In vitro experiments (N = 9) in the paraspinal muscle yielded a chemical shift factor of 0.008 +/- 0.001 ppm/ degrees C. Temperature uncertainty was determined as +/-2.7 degrees C (BW = 3.9 kHz, TE = 19.3 msec). The same experiments carried out in the paraspinal muscle (N = 9) of a fully anesthetized pig resulted in a temperature uncertainty of +/-4.3 degrees C (BW = 3.9 kHz, TE = 19.3 msec), which is higher than it is in vitro conditions (P < 0.15). Quantitative temperature monitoring of RF ablation is feasible in a 0.5 T open-configured MR scanner under ex vivo and in vivo conditions using the PFS technique.

Animals↗

Magnetic resonance myocardial first-pass perfusion imaging: parameter optimization for signal response and cardiac coverage.

Fast imaging techniques allow monitoring of contrast medium (CM) first-pass kinetics in a multislice mode. Employing shorter recovery times improves cardiac coverage during first-pass conditions, but potentially flattens signal response in the myocardium. The aim of this study was therefore to compare in patients with suspected coronary artery disease (CAD) two echo-planar imaging strategies yielding either extended cardiac coverage or optimized myocardial signal response (protocol A/B, six/four slices; preparation pulse, 60 degrees /90 degrees; delay time, 10/120 msec; readout flip angle, 10 degrees /50 degrees; respectively). In phantoms and myocardium of normal volunteers (N= 10) the CM-induced signal increase was 2.5-3 times higher with protocol B (P < 0.005) than with protocol A. For the detection of individually diseased coronary arteries (> or =1 stenosis with > or =50% diameter reduction on quantitative coronary angiography (QCA)), receiver-operator characteristics of protocol B (signal upslope in 32 sectors/heart) yielded a sensitivity/specificity of 82%/73%, which was superior to protocol A (P < 0.05, N= 14). For the overall detection of CAD, the sensitivity/specificity of protocol B was 85%/81%. An adequate signal response in the myocardium is crucial for a reliable detection of perfusion deficits during first-pass conditions. The presented protocol B detects CAD with a sensitivity and specificity similar to scintigraphic techniques.

Coronary Disease↗

PET-CT-guided percutaneous puncture of an infected cyst in autosomal dominant polycystic kidney disease: case report.

An infected cyst in autosomal dominant polycystic kidney disease was identified with a combined positron emission tomographic (PET) and computed tomographic (CT) system, an experimental setup mimicking an integrated CT-PET scanner. Image fusion of fluorine 18 fluorodeoxyglucose PET and CT images allowed exact localization of the infected cyst among many cysts identified on previous CT and magnetic resonance images. Confirmation was obtained instantly, followed by CT-guided percutaneous puncture. Integrated imaging systems hold promise for direct PET-guided puncture of areas of increased fluorodeoxyglucose uptake by using the anatomic accuracy of CT.

Escherichia coli Infections↗

[The impact of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) on planning of radiotherapy].

AIM: To determine the impact of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) on patient management in radiotherapy. MATERIAL AND METHODS: One hundred sixty-nine consecutive patients with different malignant tumors were analyzed. Whole-body FDG-PET was performed for staging before radiotherapy. The strategy of radiotherapy before and after PET scanning was compared and the change in the treatment management determined. RESULTS: In 47(28%) of 169 patients PET results changed patient management in radiotherapy. In 19 patients (11%) radiotherapy was not performed after PET. In 16 patients (10%) PET results changed the intention of radiation treatment (curative/palliative). Correction of radiation dose was made in 16 patients (10%). Correction of the volume of the exposure area was made in 12 patients (7%). Tumor outside the field of view was missed in only 2 patients with a regional PET scan. CONCLUSION: In this retrospective analysis the information provided by FDG-PET contributes to a substantial change in radiotherapy strategy.

Female↗

Joint accumulations of FDG in whole body PET scans.

PURPOSE: To retrospectively evaluate FDG accumulations in major joints in a large series of non-absorption corrected partial body and whole body FDG-PET scans, and to determine the frequency and intensity of accumulation. MATERIALS AND METHODS: 354 consecutive PET partial- and whole body non-transmission corrected scans of patients obtained for tumor staging were examined with respect to FDG accumulations in the acromio-clavicular (AC)-, gleno-humeral-, hip-, knee- and talo-tibial joints. FDG-uptake was graded using a semi-quantitative scale from 0 (no accumulation) to 4 (very strong accumulation comparable to brain uptake). RESULTS: Joint activity of grade 1-2 was noted frequently, while grade 3 was rare, occurring only in the knee and shoulder joints, and grade 4 was inexistent. The 43 patients with grade 3 accumulations or with at least 4 joints showing grade 2 uptake were interviewed, but all denied pain specifically referred to a joint. Joint accumulations were seen in 50% of the acromio-clavicular-, 80% in the glenohumeral-, 50% in the hip-, 90% in the knee and 80% in the talo-tibial joints. The intensities of joint accumulations correlated positively and significantly with patient age, ranging from r = 0.7 and p < 0.05 in the knee to r = 0.96 and p < 0.0001 in the AC joint. CONCLUSIONS: FDG accumulations in the joints in whole body FDG-PET scans are frequent and are very likely not related to symptoms. As there is a strong age correlation, and FDG is known to accumulate in inflammatory lesions, the findings are most likely a result of sub-clinical inflammatory synovial proliferation or other chronic inflammatory processes occurring in aging joints.

Adolescent↗

Magnetic resonance-based assessment of global coronary flow and flow reserve and its relation to left ventricular functional parameters: a comparison with positron emission tomography.

BACKGROUND: Measurement of coronary sinus blood flow (CSF) by phase-contrast magnetic resonance (PC-MR) imaging at rest and during hyperemia may allow noninvasive assessment of global coronary hemodynamics. METHODS AND RESULTS: Sixteen healthy volunteers (age, 22 to 32 years) were examined with MR and PET in random order within 1 to 2 days. At rest and during hyperemia (dipyridamole 0.56 mg/kg), CSF was measured by a cine PC-MR technique (temporal resolution, 40 ms; spatial resolution, 1.25x0.8 mm(2)), and myocardial blood flow (MBF) was measured by [(13)N]NH(3) PET. PET and MR agreed closely for coronary flow reserve (CFR; mean difference, 2.2+/-14.7%; Bland-Altman method). CSF divided by either total left ventricular mass or an estimate of drained myocardium (LVM(drain)) correlated highly with PET flow data (r=0.93 and 0.95, respectively) and with measures of oxygen demand, ie, heart rate, afterload-corrected fiber shortening, and peak systolic stress determined by MR (overall correlation coefficients, 0.81 and 0.87, respectively, multivariate analysis). CSF/LVM(drain) did not differ significantly from PET-derived MBF (difference, 3.6+/-16.6%). In orthotopic heart transplant recipients (n=9), CFR was reduced and blood supply-demand relationships at rest were shifted toward higher flows (P<0.0001). CONCLUSIONS: This integrated MR approach allows comprehensive assessment of autoregulated and hyperemic coronary flow and is suitable for serial measurements in patients. In transplanted hearts, elevated resting flow is the major cause of reduced CFR.

Adult↗