Search PubMed⌕ Search

Biomedical subjects

G K Prisk

Publications and source records attributed to G K Prisk.

44 records · Page 3Linked to original sources

Pulmonary function in microgravity: Spacelab 4 and beyond.

This paper refers principally to the composition gradient of gases within the lung in various conditions of gravity, as revealed by exhaled breath. A rapid gas analyzer-based system has been developed for tests in Spacelab 4. The test sequence and expected results are presented.

Breath Tests↗

Influence of collateral ventilation on single-breath washout curves.

To examine the relationship between airway closure and collateral ventilation, Ar bolus single-breath washout tests were performed in the supine position in 10 mature dogs (animals with a well-developed collateral ventilation). Transpulmonary pressure was measured simultaneously to obtain the volume above residual volume of the inflection point in the pressure-volume curve (VIP). In pigs, closing volume (CV/VC%, mean 27.4%, where VC is vital capacity) equaled the volume of inflection (VIP/VC%, mean 35.1%) when the dead space (0.07 liter) was accounted for, indicating simultaneous onset. In dogs, closing volume (CV/VC%, mean 48.1%) was greater than the volume of inflection (VIP/VC%, mean 27%). Furthermore, as closing volume increased, so did the volume exhaled between closing volume and the volume of inflection [(CV-VIP)/VC%]. These increases were strongly age related, with the oldest dogs showing the greatest differences between closing volume and volume of inflection. These results support the previous suggestion that this difference is a measure of the degree of collateral ventilation. We defined a concavity index (CI) of phase IV by measuring the ratio of the end-to-mid phase IV height above extrapolated phase III (no concavity implies CI = 2). Whereas pigs had a low CI (mean 3.3), dogs had a high CI (mean 10.6). In dogs, the CI correlated well with closing volume (CV/VC%) and the volume exhaled between closing volume and volume of inflection [(CV-VIP)/VC%]. Again, this relationship was strongly dependent on age, suggesting that the CI is also a valid indication of the degree of collateral ventilation.(ABSTRACT TRUNCATED AT 250 WORDS)

Aging↗

Gravitational independence of single-breath washout tests in recumbent dogs.

To examine the mechanisms of lung filling and emptying, Ar-bolus and N2 single-breath washout tests were conducted in 10 anesthetized dogs (prone and supine) and in three of those dogs with body rotation. Transpulmonary pressure was measured simultaneously, allowing identification of the lung volume above residual volume at which there was an inflection point in the pressure-volume curve (VIP). Although phase IV for Ar was upward, phase IV for N2 was small and variable, especially in the prone position. No significant prone to supine differences in closing capacity for Ar were seen, indicating that airway closure was generated at the same lung volumes. The maximum deflections of phase IV for Ar and N2 from extrapolated phase III slopes were smaller in the prone position, suggesting more uniform tracer gas concentrations across the lungs. VIP was smaller than the closing volume for Ar, which is consistent with the effects of well-developed collateral ventilation in dogs. Body rotation tests in three dogs did not generally cause an inversion of phase III or IV. We conclude that in recumbent dogs regional distribution of ventilation is not primarily determined by the effect of gravity, but by lung, thorax, and mediastinum interactions and/or differences in regional mechanical properties of the lungs.

Animals↗

A modeling approach to the estimation of CO diffusing capacity.

Standard methods of measuring the diffusing capacity of the lung for CO are susceptible to inhomogeneity and to errors in the performance of a breathing maneuver by the subject. A mathematical model of CO uptake from a single alveolar lung is developed and used as the basis for an estimation procedure to measure both lung volume and diffusing capacity during a rebreathing maneuver. Because this estimator-model uses the exact flow generated by the subject, errors in such factors as breath-hold times or depth of inspiration do not result. The estimator-model was tested using simulated data from uniformly and nonuniformly ventilated models and was found to be insensitive to noise and inhomogeneity, in contrast to the diffusing capacity of the lungs for CO (exhaled). The estimator-model makes greater use of the available data than traditional methods by utilizing both the slope of the alveolar plateaus for CO and the relative heights of such plateaus in a rebreathing experiment.

Capillaries↗

Estimation of amount of stationary pulmonary blood from carbon monoxide uptake measurements.

A mathematical model of CO uptake from a single alveolus is modified to include stationary pulmonary blood arising from a pulmonary vascular obstruction. From this model an estimator model is developed that produces simultaneous estimations of the diffusing capacity of the lung for CO and the fraction of the pulmonary capillary blood that is stationary. The estimator model was tested using simulated data from uniform and non-uniform simulators and found to be only mildly sensitive to noise and incorrect values for the pulmonary capillary blood volume. Both the estimator model and breath-to-breath changes in the diffusing capacity of the lung for CO (exhaled) were found to be greatly affected by inhomogeneity of diffusing capacity and ventilation. At times both returned false positive results that limit their use as a screening test for stationary pulmonary blood. Although changes in CO uptake may at times indicate the presence of stationary pulmonary blood, the confounding effects of inhomogeneity of ventilation and diffusing capacity make the use of such changes impractical under most circumstances.

Animals↗

Carbon dioxide response and breath-hold times in underwater hockey players.

Competitive underwater hockey play demands frequent and prolonged breath-hold dives. To see whether participants were physiologically adapted to breath-hold diving we studied the ventilatory response to carbon dioxide (CO2) and the breath-hold times of 34 male, underwater hockey players (divers) and compared them to 28 male, dry-land sportsmen (athletes). The divers showed an increased tolerance to CO2, the mean (+/- SD) slope of the CO2 response curve being 1.08 (+/- 0.55) liter.min-1.mmHg CO2(-1) when measured by the rebreathing method. This was significantly less (P less than 0.005) then that of the athletes 1.68 (+/- 0.72) liter.min-1.mmHg CO2(-1). The breath-hold times measured at 2 lung volumes did not differ significantly between the 2 groups. A subgroup of 8 international underwater hockey players exhibited prolonged breath-hold times but were otherwise similar to the rest of the divers in the other measured parameters.

Adult↗

Characterizing and correcting for the dynamic response of a bag-in-box system.

A bag-in-box system (BBS) whose volume is monitored by a mechanical spirometer tends to have a slow response if the volume of the box is large, and this may significantly affect its measurement of gas flow. We describe a device for creating reproducible gas flows with which the impulse response of a BBS may be conveniently determined. Two computational techniques for correcting a BBS flow measurement for the effects of the impulse response were investigated: 1) an exponential model method that assumes a second-order model of the BBS dynamics and 2) a Fourier transform-based method of deconvolution known as Wiener filtering. Both correction methods produced a significant increase in the accuracy of BBS flow estimations, with the Wiener filter giving superior results.

Respiratory Function Tests↗

Correcting for the dynamic response of a respiratory mass spectrometer.

Mass spectrometers produce distorted measurements of gas concentrations because of the time delays and rise times inherent in their responses. Three techniques for numerically correcting such distortion were applied to the acetylene step responses of a Perkin-Elmer MGA1100 mass spectrometer and to simulated data. The techniques investigated were 1) a simple time-delay correction, 2) an exponential model method that assumes a biexponential form for the peak of the impulse response, and 3) a Fourier transform method of deconvolution known as Wiener filtering. The time-delay correction produced an order of magnitude reduction in measurement error. The exponential model method improved on the time-delay correction, and the Wiener filter gave the most accurate corrections in all cases examined.

Fourier Analysis↗