The ISOLDE trial. Pharmaceutical companies should admit high cost of treatment.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G K Crompton.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Previous work has suggested that the long-term regular use of inhaled beta2-agonist bronchodilators might lead to a deterioration in asthma control. The aim of TRUST (The Regular Use of Salbutamol Trial) was to study the effects of regular use of inhaled salbutamol, the most widely prescribed bronchodilator in the UK, on the control of asthma. METHODS: A randomised, double-blind, placebo-controlled trial was undertaken in 983 patients with asthma being treated at least twice a week with short-acting beta2-agonist, alone or in combination with inhaled steroids (2 mg or less) daily. Patients were aged 18 years and over and were recruited from 115 general practices in the UK. 90% (881) of the patients used inhaled corticosteroid therapy, and all patients continued to use their usual inhaled beta2-agonist for symptomatic relief. Patients were randomised to receive 400 microg salbutamol or matched placebo via a Diskhaler four times per day for 12 months. The primary outcome measure was rate of exacerbations of asthma, with criteria based on data from diary cards completed daily by each patient, treatment with additional corticosteroids, or both. FINDINGS: There were no differences in the annual rate, timing, or duration of exacerbations between the two groups. The mean morning peak expiratory flow was similar for the two groups. The mean evening peak expiratory flow (p<0.001) and the diurnal variation (p<0.001) were greater, and the use of rescue bronchodilator was less (p<0.001), in the group receiving regular salbutamol. INTERPRETATION: There was no evidence that regular use of inhaled salbutamol 400 microg four times daily for a year increased the exacerbation rate of asthma in the population studied.
Explore the source record for details and available documents.
BACKGROUND: Dysphonia is a known local adverse effect of inhaled corticosteroids. This symptom was investigated by laryngoscopy and assessment in a voice laboratory. The effects of changing the treatment of patients with dysphonia, reported whilst using the pMDI, to pMDI plus Nebuhaler or Tubuhaler was also assessed. METHODS: Seventy-two patients reporting dysphonia and taking inhaled steroids from a pMDI entered a 12-week, open, parallel group study. Fifty-one completed the study per protocol; 26 in the Nebuhaler group [21 female, mean age 57 years (22-77)] and 25 in the Turbuhaler group [18 female, mean age 58 years (21-81)]. A dysphonia diary card was completed weekly. Voice laboratory assessments and laryngoscopy were performed on entry and at 12 weeks. RESULTS: There were no differences in voice laboratory data, laryngoscopic evidence of disordered glottic closure and diary data between the two groups at 12 weeks. At study entry laryngoscopic appearances were normal in almost half the patients. Vocal cord bowing was rarely seen. Glottic closure changed in nine patients during the study period, but there was no correlation with voice symptoms. The trend of symptomatic improvement of voice status in the Turbuhaler group did not correlate with voice laboratory assessments and laryngoscopic evidence of disordered glottic closure. After 4 weeks, 40% of patients using Turbuhaler and 8% in the Nebuhaler group scored their voice status as better (P < 0.02) but there was no significant difference between the two groups at 12 weeks (Turbuhaler 52%, Nebuhaler 23%, P=0.08). CONCLUSION: This study does not support the view that dysphonia in asthmatics inhaling corticosteroids is usually caused by myopathic bowing of the vocal cord muscles.
Inefficient inhaler technique is a common problem resulting in poor drug delivery, decreased disease control and increased inhaler use. The aim of this study was to assess patients' use of different inhaler devices and to ascertain whether patient preference is indicative of ease of use and whether current inhaler use has any influence on either technique or preference. We also wished to define the most appropriate method of selecting an inhaler for a patient, taking into account observed technique and device cost. One hundred patients received instruction, in randomized order, in the use of seven different inhaler devices. After instruction they were graded (using predetermined criteria) in their inhaler technique. After assessment patients were asked which three inhalers they most preferred and which, if any, they currently used. Technique was best using the breath-actuated inhalers; the Easi-Breathe and Autohaler, with 91% seen to have good technique. The pressurized metered dose inhaler (pMDI) fared poorly, in last position with only 79% of patients showing good technique, despite being the most commonly prescribed. The Easi-Breathe was by far the most popular device with the patients. The Autohaler came in second position closely followed by the Clickhaler and Accuhaler. The majority of patients (55%) currently used the pMDI but the pMDI did not score highly for preference or achieve better grades than the other devices. Only 79% of patients tested could use the pMDI effectively even after expert instruction yet it continues to be commonly prescribed. This has important repercussions for drug delivery and hence disease control. Prescribing a patient's preferred device increases cost but can improve efficiency and therefore be cost effective in the long term. Using an inexpensive device (pMDI) when technique is good and the patient's preferred inhaler device when not is one way to optimize delivery and may even reduce cost.
BACKGROUND: Little is known about the management of acute asthma prior to hospital admission. Pre-hospital treatment of patients referred to hospital with acute asthma was therefore studied in 150 patients divided into three groups: those in the Edinburgh Emergency Asthma Admission Service (EEAAS) who can contact an ambulance and present directly to respiratory services when symptoms arise (n = 38), those under continuing supervision at a hospital respiratory outpatient clinic (n = 54), and those managed solely in primary care (n = 58). METHODS: Standardised admission forms detailing aspects of pre-hospital management, case records, GP referral letters, and ambulance patient transport forms were analysed. RESULTS: In each group airflow obstruction had improved upon arrival at hospital, the effect being most marked in patients transported by ambulance (p<0. 001) and in those receiving nebulised beta(2) agonists prior to admission (p<0.005). However, 25% of patients arrived without having nebulised beta(2) agonists and 37% without having glucocorticoids. EEAAS patients were least likely to receive nebulised beta(2) agonists before arrival at hospital (p<0.05). This observation was attributable to a tendency for these patients to travel to hospital by car rather than by ambulance. CONCLUSIONS: There is an important shortfall in administration of bronchodilators and glucocorticoids for acute asthma before arrival at hospital. Ambulances equipped with nebulised bronchodilators provide the optimal mode of transport to hospital for patients with acute asthma. In Edinburgh ambulances are not being used by a significant proportion of the population with asthma, possibly because of the mistaken belief that personal transport arrangements reduce journey time to hospital.
Many patients with chronic obstructive airways disease (COAD) receive therapy by the inhaled route. This study was performed to assess whether patients with severe COAD could generate sufficient peak inspiratory flow (PIF) through Turbuhaler (Astra, Sodertalje) to operate it effectively. One hundred patients (45 men, 55 women, mean age 69.1 years) with COAD (mean (SD) duration 17.7 (16.3) years) and peak expiratory flow (PEF) < or = 200 l min-1 or forced expiratory volume in 1 sec (FEV1) < or = 1 litre were studied. A series of randomly assigned inspiratory and expiratory lung function tests were contiguously performed, using portable spirometers, within 48 h of a screening visit. An empty Turbuhaler was used in the study. The patients' normal medication was not restricted. Sixty-six patients were previous smokers, eight occasional smokers, 19 habitual smokers and seven had never smoked. Mean (SD) FEV1 was 0.7 (0.2) 1 and mean PEF was 182 (68) l min-1. All patients were able to generate PIF through Turbuhaler (PIF-T) of 28 l min-1 (mean 53; range 28-78 l min-1). Eighty-three patients generated PIF-T of > or = 40 l min-1. PIF-T correlated with PIF without Turbuhaler (r = 0.35), PEF (r = 0.3), FEV1 (r = 0.2) and forced vital capacity (FVC) (r = 0.23) although the relationships were too weak to be used to predict PIF-T. The results suggest that patients with severely limited lung function caused by COAD can operate Turbuhaler effectively.
A 61-year-old man developed hypersensitivity pneumonitis and skin rash in close association with taking co-proxamol. These problems occurred in spite of being treated with prednisolone 40 mg daily (20 mg daily at the time of presentation) for assumed cranial arteritis. A therapeutic challenge with paracetamol was negative and the patient continues to take this drug. It seems likely that this patient's rash and hypersensitivity pneumonitis was caused by dextropropoxyphene. Dextropropoxyphene has not been reported previously as a cause of hypersensitivity pneumonitis.
Salmeterol inhaled twice-daily is now being used more frequently as additional treatment in asthma insufficiently controlled by inhaled corticosteroids. We compared oral bambuterol in a dose of 20 mg taken once daily in the evening with inhaled salmeterol at 50 microgram taken twice daily in 126 asthmatic patients (60 bambuterol, 66 salmeterol) aged 18 to 74 yr who were treated for at least 4 wk with inhaled corticosteroids at a constant dose of 400 to 2,000 microgram/d or with oral corticosteroids at </= 20 mg/d. The patients were able to use a pressurized metered dose inhaler (pMDI) efficiently, and had an FEV1 of 40 to 85% of the predicted normal value. During a run-in period, patients had to show at least one nocturnal or early awakening caused by asthma symptoms that required rescue medication, and a >/= 15% overnight decrease in peak expiratory flow (PEF) on 3 of the preceding 7 d, in order to be randomized into this double-blind, double dummy, multicenter parallel group study (2-wk run-in period and 6 wk of treatment). There was no significant difference between bambuterol and salmeterol in morning change from baseline in PEF (p = 0.53). The median increases in morning PEF were 50 L/min for bambuterol and 55 L/min for salmeterol. Other variables (evening PEF, percent of overnight decrease in PEF, number of awakenings, percent of nights with an awakening, number of puffs of rescue medication, asthma symptoms during the day and night, and mean tremor score) also showed no significant difference between bambuterol and salmeterol. Both treatments, at the doses given, were well tolerated. Once-daily oral bambuterol is a convenient, effective, and less expensive alternative to twice-daily inhaled salmeterol for treating nocturnal asthma.
Explore the source record for details and available documents.
Twenty-six patients with severe COPD or asthma completed standard questionnaires before, and 2 months after, starting home nebulized bronchodilator therapy. Patients' perceived illness severity and their expectations of treatment with regard to symptoms were examined in the first questionnaire, and outcome was assessed in the second. Before treatment started patients expected a definite improvement in all symptoms studied. After treatment the group showed only a marginal subjective improvement in all symptoms. The improvement attained with regard to breathlessness, ability to get out and about, and general quality of life was significantly lower than had been expected. While home nebulized bronchodilator therapy is well tolerated and confers some subjective benefit in selected individuals, patients appear to have unrealistically high expectations of treatment.
The Spacehaler is a new, compact, pressurized aerosol device that uses the same canister as a conventional metered-dose inhaler (MDI). Its design, however, reduces the velocity of the aerosol cloud that emerges from the inhaler, thereby reducing the amount of the non-respirable fraction of the drug delivered to the patient. Large volume spacers achieve a similar effect, but they are bulky and therefore inconvenient to use and carry around. This study compared the bronchodilator effect of 200 micrograms salbutamol delivered by the Spacehaler to that of an MDI used with a Volumatic spacer (MDI plus spacer) in patients with reversible obstructive airways disease. Twenty-five patients with asthma, having a forced expiratory volume in 1 s (FEV1) between 50 and 90% predicted and a reversibility of > or = 15% to 200 micrograms salbutamol given by the conventional (standard) MDI entered the study. On two separate study days, they inhaled 200 micrograms salbutamol either via the Spacehaler or the MDI plus spacer. To maintain blinding, they received placebo on both study days via the alternate device. Their FEV1, forced vital capacity (FVC) and peak expiratory flow (PEF) were measured before and at regular intervals for 6 h after inhalation. Assessment of equivalence between the two devices was based on whether the 90% confidence interval for the difference between the weighted mean FEV1 was within +/- 0.25 1. Patient preference was assessed by a questionnaire at the end of the second study day. Twenty-four patients completed the study. Both devices produced a significant improvement in FEV1 (P < 0.02). The upper and lower 90% confidence limits for the difference in weighted mean FEV1 between the devices was +/- 0.041, and the 99% confidence limits were +0.061 and -0.071. The weighted means for FVC and PEF, and the duration of effect and peak responses for FEV1, FVC and PEF also showed no difference between the two devices. Patients found no difficulty in using the Spacehaler, and 20 out of 24 patients (83.3%) preferred it to the MDI plus spacer. The bronchodilator effect of 200 micrograms salbutamol administered by a Spacehaler was equivalent to that produced by an MDI plus spacer in this group of patients with reversible airways obstruction. The majority of patients preferred it to a large volume spacer.
Ipratropium bromide (IB), typically delivered by pressurized metered dose inhaler (pMDI), is used to treat patients with reversible airways obstruction. Use of the pMDI, unlike the Turbuhaler (TH), demands co-ordination of actuation with inspiration for efficient use. Two studies were carried out to compare the relative efficacy and potency of IB delivered by TH or pMDI. Both studies were of a randomized, double-blind and cross-over design. For the efficacy study, 15 patients received a cumulative dose of 160 microg IB via TH or pMDI as doses of 20, 20, 40 and 80 microg at 45 min intervals on two days. Forced expiratory volume in one second (FEV1) was measured prior to and 40 min after dosing. For the potency study, 33 patients received 10, 20 or 40 microg of IB via TH, 20 microg IB via pMDI, or placebo, on five days. FEV1 was recorded prior to and 15-360 min after dosing. For the efficacy study, there was no difference in FEV1 response to a cumulative dose of IB via pMDI and TH. More than 80% of the maximum effect was seen at the lowest dose (20 microg of IB). Regarding the potency study, the FEV1 response to 20 microg IB administered via pMDI was similar to that of 10 microg via TH; 20 microg via TH was significantly more effective than 20 microg via pMDI (p<0.05). In conclusion, the efficacy study showed that maximum FEV1 occurred at low doses of IB, negating any opportunity to identify differences between devices. The potency study indicated that the 10 microg dose via TH was of similar efficacy to the 20 microg dose via pMDI, confirming an efficacy ratio of 1.5-2.0:1 for the TH device.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Nebulised salbutamol can now be administered by ambulance personnel to patients with severe acute asthma en route to hospital. This treatment, however, is not yet available in all ambulances. The safety and effectiveness of allowing ambulance crews to initiate treatment with nebulised salbutamol has been assessed in patients with acute severe asthma. METHODS: After a basic training course in the assessment of asthma and the use of a nebuliser, ambulance crews initiated treatment with nebulised salbutamol in asthmatic patients under the age of 40 years. Airflow obstruction was measured before and after treatment with a peak flow meter. A subjective assessment of any change in the patient's condition was also made. RESULTS: Nebuliser treatment was associated with a significant increase in peak flow in almost 80% of patients who had recordable values before and after treatment. The mean percentage increase in peak flow was 56.5%. Subjective assessments correlated well with peak flow measurements. No unwanted side effects were recorded. CONCLUSIONS: Nebulised salbutamol is an effective and safe treatment for acute asthma when administered by ambulance personnel after a short training course.
BACKGROUND: A retrospective study was carried out to confirm the clinical impression that, in Lothian, non-tuberculous mycobacterial infections are as common as pulmonary tuberculosis. METHODS: All pulmonary isolates of Mycobacterium tuberculosis/bovis and non-tuberculous mycobacteria in Scotland from April 1990 to March 1993, and the notes of all patients with M malmoense isolates in Lothian, were reviewed. Information on mycobacterial culture procedures in Scottish laboratories was obtained as part of an audit project. RESULTS: Of all pulmonary isolates of mycobacteria in Lothian 53% (108/205) were non-tuberculous strains compared with 18% (140/800) for Scotland outside Lothian. Although comparable in population size and laboratory techniques, Lothian (108) had almost twice as many isolates of non-tuberculous mycobacteria as Glasgow (56), but the proportions of M malmoense and M avium intracellulare complex were similar in both areas. Of 41 patients with M malmoense isolates in Lothian 30 (75%) had clinically significant lung disease; only one was HIV positive. CONCLUSIONS: Non-tuberculous mycobacteria pose an increasing clinical problem in Scotland as a cause of pulmonary disease. There is a cluster of cases with M malmoense infection in Lothian which cannot be attributed to the high local prevalence of HIV.