Search PubMed⌕ Search

Biomedical subjects

G Holló

Publications and source records attributed to G Holló.

At least 19 recordsLinked to original sources

Diurnal IOP control with bimatoprost versus latanoprost in exfoliative glaucoma: a crossover, observer-masked, three-centre study.

AIM: To evaluate the diurnal intraocular pressure (IOP) control and safety of bimatoprost versus latanoprost in exfoliative glaucoma (XFG). METHODS: One eye of 129 consecutive patients with XFG (mean (SD) age 66.5 (8.3) years) was included in this prospective, observer-masked, three-centre, crossover comparison. After a 4-6 week medicine-free period patients were randomised to bimatoprost or latanoprost monotherapy for 3 months. Patients were then switched to the opposite treatment for another 3 months. At the end of the washout and the treatment periods diurnal IOP was measured at 0800, 1300, and 1800. RESULTS: At baseline the IOP (mean (SD)) was 28.0 (4.0), 26.9 (3.6), and 25.9 (3.6) mm Hg, at the three time points, respectively. Both treatments significantly reduced mean diurnal IOP at month 3. Mean diurnal IOP was 26.9 (3.5) mm Hg at baseline, 17.6 (3.3) mm Hg with bimatoprost, and 18.6 (3.6) mm Hg with latanoprost (p<0.0001). Furthermore, lower IOP values were obtained with bimatoprost at all time points (17.9 (3.4), 17.3 (3.3), and 17.6 (3.5) mm Hg, respectively) compared with latanoprost (18.7 (3.6), 18.5 (3.6), and 18.6 (4.1) mm Hg, respectively). The corresponding mean differences (0.8, 1.1, and 1.0 mm Hg, respectively) were all significant (p<0.001 for each comparison). Significantly more patients with XFG obtained a target diurnal IOP <17 mm Hg with bimatoprost than with latanoprost, 55/123 (45%) v 34/123 (28%); (p = 0.001), and significantly fewer patients were non-responders with bimatoprost than with latanoprost (5 v 13, p = 0.021). More patients reported at least one adverse event with bimatoprost than with latanoprost (58 v 41 at 3 months; p = 0.0003). CONCLUSION: This crossover study suggests that better diurnal IOP control is obtained with bimatoprost than with latanoprost in patients with XFG.

Adult↗

Increase of carotid artery stiffness and decrease of baroreflex sensitivity in exfoliation syndrome and glaucoma.

AIM: To investigate the distensibility of the common carotid artery (CCA), baroreflex sensitivity (BRS) and its relation to plasma homocysteine concentration in exfoliation syndrome or exfoliation glaucoma (XFS/XFG). METHODS: Homocysteine concentrations were measured in 30 XFS/XFG patients and 18 age matched controls. In 21 patients and 17 controls the end diastolic diameter of the CCA and pulsatile distension were measured and BRS was calculated. RESULTS: There was no significant difference between the groups in sex distribution, age, heart rate, blood pressure, systemic diseases, or medication. In XFS/XFG patients homocysteine concentration was significantly elevated (unpaired t test, p = 0.023), and CCA stiffness was higher (p<0.05), while strain, cross sectional compliance coefficient, distensibility, and BRS were significantly reduced compared to the controls (Mann-Whitney U test, p< or =0.013 for each parameter). In XFS/XFG patients a positive correlation was found between age and plasma homocysteine level (Pearson's correlation, r = 0.490, p = 0.007), and a negative correlation between age and BRS (Kendall's correlation r = -0.374, p = 0.021), as well as between homocysteine concentration and BRS (Kendall's correlation r = -0.377, p = 0.024). No correlation was seen between these variables in the control group. CONCLUSIONS: These results suggest a pathological large artery function as well as altered parasympathetic vascular control in XFS/XFG which increases with age and with higher homocysteine concentration.

Aged↗

Comparison between fixed-angle and customised corneal-polarisation compensation methods in scanning laser polarimetric measurement of the retinal nerve fibre layer in glaucoma.

PURPOSE: To investigate the differences between the results of scanning laser polarimetric (SLP) measurements of the retinal nerve fibre layer thickness (RNFLT) made using two different corneal-polarisation techniques; customised (SLP-C), and fixed-angle (SLP-F) compensations. METHODS: Both SLP-C and SLP-F were performed on 37 consecutive phakic patients with chronic open-angle glaucoma, and on 14 healthy control subjects. One randomly selected eye per subject was evaluated. RESULTS: Both SLP-C and SLP-F parameters were able to discriminate between the glaucoma group and the control group, except in the case of the ellipse modulation, which differed significantly between the two groups with SLP-C (P=0.017), but not with SLP-F (P=0.056). When SLP-C and SLP-F values were compared, inferior maximum thickness and ellipse standard deviation were significantly lower with SLP-C in both groups (P<0.05 for each parameter). Superior maximum thickness was significantly lower in glaucoma with SLP-C than with SLP-F (P=0.006) and tended to be lower with SLP-C than with SLP-F in the control group (P=0.053). In the glaucoma group, it was only with SLP-C that a significant (positive) correlation between the superior maximum thickness and the inferior hemifield mean sensitivity (MS) (r=0.653, P<0.001), and between the inferior maximum thickness and the superior hemifield MS (r=0.420, P=0.023) was found. The other global and sectoral SLP parameters showed significant correlation with the corresponding visual field parameters with both techniques. CONCLUSION: Our findings suggest that SLP measurements with customised compensation provide more realistic results for RNFLT than those made with the conventional fixed-angle compensation.

Adult↗

Influence of subfoveal choroidal neovascularisation on macular imaging with scanning laser polarimetry of the retinal nerve fibre layer.

PURPOSE: To investigate the influence of subfoveal choroidal neovascularisation (CNV) on macular imaging performed using scanning laser polarimetry (SLP) of the retinal nerve fibre layer. METHODS: SLP was performed on 22 consecutive patients with angiographically verified CNV, and on 23 healthy control subjects. One eye per subject was evaluated using the GDx Nerve Fibre Analyser. Regularity of the corneal retardation on the macular SLP images was assessed according to three criteria: (1) magnitude of the 'macular ratio', defined as the ratio of mean retardation values along two axes (the axis with the maximum retardation and the perpendicular one, corresponding in healthy eyes to minimum retardation); (2) the values of GDx parameters which are independent of quadrant position (ellipse modulation and ellipse average); and (3) the frequency of the regular 'bow-tie' polarisation pattern. RESULTS: 'Macular ratio' was significantly higher in the CNV group than in the control group (P<<0.001). Ellipse modulation did not differ between the groups, but ellipse average was higher in the CNV group (P=0.016). The variance for each of these two parameters was significantly higher for the CNV group (P<<0.001 for both comparisons). A 'bow-tie' pattern polarisation was seen in 23 of the 23 control eyes, but only in 7 of the 22 CNV eyes (P<<0.001). CONCLUSION: The results show that CNV influences the macular image obtained with SLP. This suggests that measurements with SLP may be disturbed for eyes with CNV when the customised corneal compensation method, which makes use of the macular retardation image, is employed.

Adult↗

Enhanced corneal compensation for scanning laser polarimetry on eyes with atypical polarisation pattern.

AIM: To investigate the potential advantage of an enhanced corneal compensation algorithm (ECC) compared with variable corneal compensation (VCC) in the analysis of scanning laser polarimetric (SLP) images with atypical retardation pattern (ARP). METHODS: SLP-VCC images with ARP (typical scan score (TSS) <80) of one eye of each of 27 glaucoma patients and 19 healthy subjects were compared with the corresponding SLP-ECC images obtained at the same session. RESULTS: ARP was present in 10.4% of the normals and 15.5% of the glaucoma patients imaged with SLP-VCC over 9 months. In both groups TSS was higher for ECC than for VCC (p<0.001). In glaucoma TSNIT, superior and inferior average thickness values were significantly lower, and TSNIT (measuring ellipse around the optic nerve head in the four (temporal, superior, nasal, inferior) quadrants) standard deviation was significantly higher with ECC than with VCC (p<0.001). In the normal group nerve fibre indicator (NFI) was lower with ECC than with VCC (p=0.007). TSNIT average was smaller and TSNIT standard deviation was higher with ECC (p<0.001). Superior and inferior average thickness did not differ between VCC and ECC in the normal group. CONCLUSIONS: The new ECC software substantially improves polarimetric image analysis on eyes showing atypical polarisation pattern.

Accommodation, Ocular↗

Scanning laser polarimetry of retinal nerve fibre layer thickness after laser assisted in situ keratomileusis (LASIK): stability of the values after the third post-LASIK month.

BACKGROUND: Monitoring the retinal nerve fibre layer thickness (RNFLT) is essential in the diagnosis and treatment of glaucoma. In a previous study we found that a decrease of the polarimetric RNFLT observed in the early period after laser-assisted in situ keratomileusis (LASIK) disappears or tends to disappear by the third post-LASIK month. PURPOSE: To study the stability of the "recovered" polarimetric retardation values between the third and twelfth month after LASIK. METHODS: Scanning laser polarimetry (SLP) with the classic GDx Nerve Fiber Analyzer was performed on 13 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. Measurements were performed preoperatively, then at 3 and 12 months postoperatively. RESULTS: Inferior, temporal and nasal average thickness as well as ellipse average thickness and average thickness showed no difference among the three time points (ANOVA, p > 0.05). Superior average thickness was significantly smaller both at three months (Sheffe test, p =0.008) and 12 months (p =0.006) than before LASIK. However, no difference was seen between the values measured at three months and at 12 months after LASIK (p =0.997). A statistically significant interaction between treatment type (myopic or hyperopic correction) and the change of retardation was found for the superior average thickness (two-way ANOVA, p =0.016). In this quadrant the RNFLT values of the myopic eyes decreased between the baseline and the month 3 measurements but became stable after that; the retardation of the hyperopic eyes remained unchanged throughout. CONCLUSION: RNFLT measured with the classic GDx device after LASIK shows transient changes probably due to the LASIK-induced alteration of the polarization and the healing process. The polarimetric RNFLT values, however, become stable by the third post-LASIK month, and show no further change until the end of the first year after LASIK. Baseline SLP measurements for long-term glaucoma follow-up can be obtained from the third post-LASIK month onwards.

Adult↗

Influence of LASIK on scanning laser polarimetric measurement of the retinal nerve fibre layer with fixed angle and customised corneal polarisation compensation.

BACKGROUND/AIM: Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values. METHODS: Scanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests. RESULTS: Superior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters-namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called "the number") remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method. CONCLUSION: The results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggest an increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.

Adult↗

Influence of post-LASIK corneal healing on scanning laser polarimetric measurement of the retinal nerve fibre layer thickness.

AIM: To investigate the influence of laser assisted in situ keratomileusis (LASIK) on the values for retinal nerve fibre layer thickness (RNFLT) as measured with scanning laser polarimetry (SLP) during the healing process of the cornea after LASIK. METHODS: SLP with the GDx instrument was performed on 20 consecutive healthy subjects without any eye disease undergoing LASIK for ametropia correction. The SLP measurements were performed before the surgery, and at 1 and 3 days, as well as at 3 months, after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Duncan multiple comparison tests. Correlation coefficients between RNFLT data and the treatment parameters were also calculated. RESULTS: Somewhat similar results were found for the different retinal areas. The measured values for superior average RNFLT decreased significantly at all time points compared to the preoperative baseline (p<0.003, Duncan test), but increased significantly between postoperative day 1 and the final visit at 3 months (p=0.025, Duncan test). Inferior average RNFLT in the early postoperative days was significantly smaller than at 3 months after LASIK (p<0.05, Duncan test), and tended to be smaller than at baseline. The thickness values before surgery and at the final visit, however, showed no significant difference (p=0.698, Duncan test) in this region. Ellipse average RNFLT was significantly smaller in the early postoperative days than the baseline value before LASIK. However, the measured value had significantly increased again by the time of the final visit (p<0.02, Duncan test). This value at the final visit showed no difference from the baseline value (p=0.46, Duncan test). The changes in the nasal average and temporal average RNFLT were not statistically significant. No correlation was found between the change in the SLP measured thickness values and central corneal thickness at baseline and its change after surgery, nor with the change in cylindrical correction due to LASIK, or the length of the suction time during surgery (p>0.05 for all correlations). CONCLUSION: The SLP technique is sensitive to the corneal optical properties, and RNFLT as measured with SLP shows changes after LASIK. Most of these changes, however, diminish with time after surgery, and the values tend to return to the preoperative results during the first 3 months of corneal healing following uncomplicated LASIK. It appears that in uncomplicated cases the transient RNFLT changes are artefacts and do not imply pathological thickness alterations due to LASIK.

Adult↗

Scanning laser polarimetry versus frequency-doubling perimetry and conventional threshold perimetry: changes during a 12-month follow-up in preperimetric glaucoma. A pilot study.

PURPOSE: To evaluate the possibility for detecting the progression in preperimetric primary open angle glaucoma (POAG) using scanning laser polarimetry (SLP), frequency-doubling technology (FDT), and conventional automated perimetry (AP). PATIENTS AND METHODS: 22 eyes of 11 preperimetric POAG patients were evaluated using SLP (Nerve Fiber Analyzer, GDx), AP (Humphrey 24-2 threshold test) and FDT (30 degrees threshold test). All eyes had intraocular pressure (IOP) higher than 21 mmHg before treatment, but were consistently lower than 22 mm Hg with unchanged topical medication before and during the study. At the initial evaluation session optic nerve heads showed mild glaucomatous changes but the visual fields were normal (MD better than 2.0 dB, Glaucoma Hemifield Test: within normal limits or borderline). AP and FDT measurements were repeated 6 months later, and all three tests were repeated 12 months after the first investigation. RESULTS: IOP, AP and FDT measurements showed no statistically significant changes during the 12-month follow up period. In contrast to this, a tendency for a glaucomatous type decrease was seen with SLP in the retinal nerve fibre layer (RNFL) thickness parameters (mean superior and inferior sector thickness values, ellipse average thickness and maximal modulation). The mean decrease of RNFL thickness in the superior and inferior sectors was 2.77 microm and 2.48 microm, respectively. Using the two-way nested ANOVA, which considers the relation between the right and left eyes of the subjects, the decrease was statistically significant (p=0.021) for the inferior sector RNFL thickness. CONCLUSION: The results suggest that scanning laser polarimetry is a useful technique to detect and measure glaucomatous progression in early glaucoma. Scanning laser polarimetry of the RNFL may help to detect and quantify early progression even if worsening is not seen with perimetry and FDT tests.

Adult↗

Ocuton-S self tonometry vs. Goldmann tonometry; a diurnal comparison study.

PURPOSE: To compare 24-hour diurnal intraocular pressure (IOP) measurements obtained using the Ocuton-S applanation self tonometer and the Goldmann tonometer. METHODS: 24-hour diurnal IOP curves were obtained on 14 eyes of 7 trained patients suffering from medically controlled primary open angle glaucoma. IOP was measured every third hour starting at 9 a.m. with a calibrated Goldmann tonometer; one week later, a similar set of measurements was obtained with Ocuton-S self tonometry by the patients. One week later still, ultrasound corneal pachymetry was performed at the same hours. RESULTS: Overall IOP (24-hour mean) did not differ significantly between the different measuring techniques (ANOVA, p = 0.74), but the IOP differed in a statistically significant manner around the clock (ANOVA, p = 0.00006). The mean Goldmann tonometric readings were up to 2.8 mmHg lower than the Ocuton-S values during the daytime (9 a.m. to 9 p.m.), however, during the night (12 midnight to 6 a.m.) mean IOP measured with Goldmann tonometry was 2.2 to 3.3 mmHg higher than the corresponding average of the self tonometry readings. There was a statistically significant interaction between the type of tonometry and the time of the measurement (p = 0.0007). Central corneal thickness (CCT) showed a significant change during the 24-hour period (p = 0.000001). CONCLUSION: IOP shows a different diurnal curve when measured with the Goldmann tonometer and with the Ocuton-S applanation self tonometer. The instruments' readings might be influenced in different ways by the diurnal changes of the corneal thickness. Since Ocuton-S self tonometry underestimates the IOP in the early morning period, a careful evaluation is necessary when nocturnal and early morning IOP elevation is investigated with this technique.

Adult↗

Does glaucoma medication influence the diameter of the retinal arteriole in the human eye? (A pilot study using the retinal vessel analyser).

PURPOSE: To investigate the potential in vivo influence of different topical glaucoma medications on the diameter of the retinal arterioles of healthy volunteers and glaucoma patients. METHODS: The diameter of one pre-selected retinal arteriole per eye was measured using the Retinal Vessel Analyser (RVA), an instrument developed for non-invasive clinical measurement of the diameter of the main retinal vessels. The instrument contains a video system, and the integrated software recognises the boundaries of the retinal vessels by detecting their light-transmission profile. The vessel diameter (in arbitrary units) is plotted against time (seconds) on a separate display screen. In Study I the vessel diameter was measured in 12 eyes of six healthy volunteers (age 21-26 years, mean age 24.0 years) on six occasions each separated by 14 days. In a double-masked fashion, each subject's right eye was treated with one of 5 glaucoma medications (brinzolamide 1%, timolol 0.5%, betaxolol 0.5%, brimonidine 0.2% or latanoprost 0.005%) and the left eye always received balanced salt solution. In Study II, one randomly selected eye of 16 patients (age 50-79 years, mean age 65.2 years) suffering from primary open-angle glaucoma controlled with topical monotherapy was investigated, in an unmasked fashion. Four patients were on betaxolol 0.5% treatment, six subjects were receiving non-selective topical beta receptor blockers and six subjects were being treated with once daily latanoprost 0.005%. RESULTS: The coefficient of variation for the arteriole diameter in the healthy volunteers was less than 12% in each case. No significant post-treatment change of the diameter of the pre-selected arteriole was found for any topical medication investigated, either in the healthy volunteers (Study I) or in the patients suffering from glaucoma (Study II) (p>0.05, paired t-test). In addition, in Study I no difference was observed in the alteration of the arteriole diameter between the baseline and the hour 2 measurements when the values from the drug-treated and placebo treated eyes were compared (p>0.05, two-way ANOVA). CONCLUSION: In the present investigations it was not possible to detect any statistically meaningful change of the arteriole diameter at two hours after the instillation of any of several topical antiglaucoma drugs widely used in clinical practice. Further investigations are necessary to clarify whether the lack of observed change is due to the lack of retinal vascular effects of the drugs investigated, or is due to an inability of the RVA instrument in practice to detect alterations between time-points separated by several hours.

Adrenergic alpha-Antagonists↗

Immediate increase in aqueous humour endothelin 1 concentration and intra-ocular pressure after argon laser trabeculoplasty in the rabbit.

PURPOSE: To investigate the immediate changes of aqueous humour endothelin 1 (ET-1) concentration and intra-ocular pressure (IOP) after argon laser trabeculoplasty (ALT) in the rabbit. METHODS: Standard ALT was performed in one eye of 11 pigmented rabbits. IOP was measured with a Tono-Pen-2 tonometer before treatment, under general anaesthesia. Postlaser IOP measurements followed by aqueous humour aspiration were performed under general anaesthesia 30 and 60 min after treatment in 6 and in 5 animals, respectively. RESULTS: The aqueous humour ET-1 concentration was significantly higher (55.0 pg/ml) after ALT than in the contralateral eyes without laser treatment (8.2 pg/ml, p = 0.001). IOP increased significantly after ALT (p = 0.007) but remained unaltered (p = 0.10) in the contralateral eyes without treatment. No statistically significant difference was found either in postlaser IOP elevation or in interocular ET-1 difference between the groups. CONCLUSIONS: The results suggest that in the rabbit the increase in aqueous humour ET-1 concentration after ALT is immediate, detectable even 30 min after the laser treatment, followed by no further increase during the second 30-min period after ALT, and associated with an immediate postlaser IOP elevation within 1 h after ALT. These findings may suggest a similar response to ALT in the human eye, since a similar immediate IOP elevation is frequently observed after ALT in the clinical practice.

Animals↗

Novel generation of human satellite DNA-based artificial chromosomes in mammalian cells.

An in vivo approach has been developed for generation of artificial chromosomes, based on the induction of intrinsic, large-scale amplification mechanisms of mammalian cells. Here, we describe the successful generation of prototype human satellite DNA-based artificial chromosomes via amplification-dependent de novo chromosome formations induced by integration of exogenous DNA sequences into the centromeric/rDNA regions of human acrocentric chromosomes. Subclones with mitotically stable de novo chromosomes were established, which allowed the initial characterization and purification of these artificial chromosomes. Because of the low complexity of their DNA content, they may serve as a useful tool to study the structure and function of higher eukaryotic chromosomes. Human satellite DNA-based artificial chromosomes containing amplified satellite DNA, rDNA, and exogenous DNA sequences were heterochromatic, however, they provided a suitable chromosomal environment for the expression of the integrated exogenous genetic material. We demonstrate that induced de novo chromosome formation is a reproducible and effective methodology in generating artificial chromosomes from predictable sequences of different mammalian species. Satellite DNA-based artificial chromosomes formed by induced large-scale amplifications on the short arm of human acrocentric chromosomes may become safe or low risk vectors in gene therapy.

Animals↗

Scanning laser polarimetry via intravitreal silicone oil.

PURPOSE: To investigate whether scanning laser polarimetry, a promising new technique for early detection of glaucomatous nerve fiber loss, is a suitable method to measure retinal nerve fiber layer thickness in eyes with intravitreal silicone oil. PATIENTS AND METHODS: Eleven eyes of 11 consecutive patients two days to 16 months after successful vitrectomy and intravitreal silicone oil injection and 12 eyes of 12 consecutive subjects, who never had any vitreoretinal surgery were examined using the GDx Nerve Fiber Analyzer. Three individual images were computed to a mean image using the software in each case. RESULTS: "Variance", a software-provided parameter, which represents the differences between the individual images used to calculate the mean image was higher in the "silicone oil" group (unpaired t test for different variances, p = 0.02). Good-quality mean images with a "Variance" value similar to that of the control eyes were obtained in seven of the 11 cases. Characteristic artifacts caused by intravitreal silicone oil were observed in five of the 11 cases. CONCLUSION: Successful scanning laser polarimetry is possible after vitrectomy and intravitreal silicone oil injection, and may help to monitor the retinal nerve fiber layer of these eyes in case of silicone oil induced glaucoma.

Adult↗

Cold pressor test and retinal capillary perfusion in vasospastic subjects with and without capsular glaucoma (a preliminary study).

PURPOSE: Using the cold pressor test the authors investigated the change in retinal and neuroretinal capillary perfusion in vasospastic patients suffering from capsular glaucoma (CG) and in vasospastic control subjects. METHODS: Changes in retinal and optic nerve head capillary perfusion induced by the cold pressor test (one hand immersed in 4 degrees C water for 30 seconds, then in 30 degrees C water for 2 minutes) was measured using the Heidelberg Retina Flowmeter in 4 patients with CG and in 5 healthy control subjects. Previously all subjects showed a reduction of cutaneous capillary flow higher than 70% in the cold pressor test (vasospastic reaction). One eye per subject was investigated. Two images were obtained for each phase (baseline, cold phase and warm phase), and the better quality image from each phase was selected for the measurements. One location on the temporal neuroretinal rim and one location on the temporal retina outside the peripapillary area were selected for the HRF measurements. RESULTS: In the CG group neuroretinal rim "Volume" decreased by 26.05%, "Flow" by 25.82% and "Velocity" by 23.91% (p<0.05), retinal "Volume" decreased by 12.30% (p=0.051), and retinal "Flow" by 22.36% (p=0.01) in the cold phase. All these parameters returned to the corresponding baseline values in the warm phase. In the control group a significant decrease was observed in retinal "Volume" (15.96%), "Flow" (17.81%), and "Velocity" (16.11%) in the cold phase (p<0.05), which diminished in the warm phase but remained still significant for "Flow" and "Velocity". CONCLUSION: Cutaneous cold provocation can induce an immediate decrease in retinal and optic nerve head capillary perfusion at least in a part of the vasospastic subjects with or without capsular glaucoma. This decrease diminishes or disappears quickly when the hand is immersed in warm water. To evaluate the potential role of cold-induced retinal and optic nerve head vasoconstriction in the pathogenesis of capsular glaucoma further investigations are necessary since this reaction was also present in the vasospastic control subjects.

Aged↗