Search PubMed⌕ Search

Biomedical subjects

G Handel

Publications and source records attributed to G Handel.

At least 19 recordsLinked to original sources

The influence of electron beam irradiation on the shear bond strength of glass-reinforced frameworks and veneer composites.

The bond between glass fibre framework and veneer composite can be achieved by silane coupling agents or by monomers that penetrate into a polymer network. However, it has been clinically demonstrated that his bond can fail. This study investigated whether electron beam irradiation improved the bond strength of fibre-frameworks and veneer composite with and without additional coupling agents.

Composite Resins↗

The influence of electron beam irradiation on fibre-reinforced composite specimens.

This study investigated whether glass fibre-reinforced composite (FRC) specimens can benefit from post-curing using electron beam irradiation. Twenty-four frameworks of the Vectris and 24 of the Stick glass fibre-reinforced system were veneered with their correspondent veneer materials. Eight specimens of both systems were post-cured using electron beam irradiation (3 x 33 kGy, 10 MeV). The specimens were fixed in a restrained-end apparatus and inserted in an artificial mouth. With the exception of controls (n = 8 each) all other groups were thermally cycled and mechanically loaded (TCML). Finally, all samples were loaded to fracture using a universal testing machine. In two of eight non-irradiated Vectris/Targis specimens facing fracture occurred during TCML. Irradiation avoided these failures. No Stick/Sinfony facing fractured. However, Stick frameworks showed considerable torsions. Post-curing with electron beam irradiation made Stick frameworks stiffer. The fracture load of irradiated Stick/Sinfony specimens reached 520 +/- 31 N; control (without TCML and irradiation) 396 +/- 14 N, TCML-group without irradiation 362 +/- 41 N. Irradiated Vectris/Targis had a fracture resistance of 575 +/- 57 N; the control 556 +/- 36 N and the TCML group without irradiation 383 +/- 51 N. This investigation demonstrated that different types of FRC systems could considerably benefit from electron beam irradiation. The reconstructions became stiffer and resisted higher load.

Composite Resins↗

Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures.

OBJECTIVES: This in vitro study tested the influence of diverse stress simulation parameters on the fracture strength of all-ceramic three-unit fixed partial dentures (FPDs). METHODS: All-ceramic FPDs made of Empress 2 (Ivoclar-Vivadent, FL) were exposed to thermal cycling and mechanical loading (TCML) with varying loading parameters such as chewing force (amount, frequency), thermal loading, lateral jaw motion, abutment material, artificial periodontium or antagonistic denture. To investigate the influence of the abutment material, human teeth, polymer abutments and alloy abutments were used. Two different TCML devices with pneumatic or weight loading were compared. FPDs without aging were used as a control. RESULTS AND SIGNIFICANCE: Combined thermal and mechanical loading significantly reduced the FPD fracture resistance from 1832N to 410N. Duplication of chewing frequency, phase load increase or additional lateral movement did not effect the results. Increasing chewing force, artificial periodontium, and antagonist or abutment material reduced the fracture resistance of the tested FPDs. Different devices with weight or pneumatic loading had no significant influence on the loading capacity of the FPDs. Artificial aging should be performed combining thermal cycling with mechanical loading. Simulation of the artificial periodontium, human antagonists and abutments should be included to achieve a significant aging.

Bite Force↗

Electron beam irradiation of denture base materials.

UNLABELLED: Electron beam irradiation can be used to influence the properties of polymers. It was the aim of this study to investigate whether PMMA denture base materials can benefit from irradiation in order to have increased fracture toughness, work of fracture or hardness. Rectangular specimens of heat-and auto-curing denture base materials were electron beam irradiated (post-cured) with 25, 100 and 200 kGy using an electron acceleration of 10 MeV or 4.5 MeV respectively. Fracture toughness, work of fracture, Vickers hardness and colour changes were measured and compared with not-irradiated specimens. The toughness, work of fracture and hardness increased using 10 MeV with a dose of 25 kGy and with 100 kGy using 4.5 MeV. However, the clinical use may not benefit from the observed small changes. Higher dosage (200 kGy) decreased the values significantly. The colour changes reached a level which was found to be not clinically acceptable. CONCLUSION: PMMA denture base materials do not benefit from post-curing with electron beam irradiation.

Dental Materials↗

Composite veneering of metal based fixed partial dentures.

The aim of this in vitro study was to determine the thermal mechanical properties of veneering composites after polymerization with the appropriate polymerization device. Fracture tests were performed to investigate the effect on fixed partial dentures (FPDs). Dynamic mechanical thermal analysis was used to determine the temperature-dependent mechanical properties. To approximate the clinical situation, the fracture resistance of three-unit metal-based FPDs with different composite veneering was investigated after a simulated 5-year oral wearing period. The restorations were made of a high gold alloy and veneered with three different composites. To determine the influence of fabrication, one composite was used in a light-polymerizing and a heat/pressure-curing version and, in addition, a newly developed heat protection paste was used. After a 5-year simulation period, the fracture resistance was determined. The storage modulus varied between 14268 N mm(-2) (Belleglass) and 6616 N mm(-2) (Sinfony). Adoro showed no significant differences between light curing (9155 N mm(-2)) and heat curing (8184 N mm(-2)) variations. The Adoro-veneering with the heat protection paste showed the highest median fracture strength (1700 N), followed by Adoro LC (1555 N), Belleglass (1051 N), Adoro HP (1150 N) and Sinfony (909 N). The most common failure type occurring in all FPDs was a cracking of the composite, exposing the metal framework. All FPDs showed stress cracking of the composite. The heat protection paste seemed to reduce the crack formation after fabrication and increased the fracture resistance of the composite veneering. Stress cracking after thermal cycling and mechanical loading affected all composites, but all veneered three-unit alloy FPDs showed a fracture resistance sufficient for posterior application.

Composite Resins↗

Marginal adaptation in dentin of a self-adhesive universal resin cement compared with well-tried systems.

OBJECTIVES: This study compares the marginal adaptation of a new self-adhesive universal resin cement with only one application step, to the marginal adaptation of established cements and their corresponding adhesive systems. METHODS: All-ceramic crowns were inserted on human molars using a new self-adhesive universal resin cement without and with one pre-treatment step, a resin cement with a smear-layer removing and a compomer cement with a smear-layer dissolving adhesive system. After simulation of five years oral stress, the marginal adaptation was evaluated by dye penetration and scanning electronic microscope analysis using the replica technique. RESULTS: Scanning electron microscopy: all investigated luting agents showed comparable amounts of 'perfect margin' ranging between 88-98% (median). Dye penetration: the self-adhesive system had significantly lower dye penetration (18-25%, median). SIGNIFICANCE: The results indicate that a self-adhesive universal resin cement without pre-treatment can provide a marginal adaptation at dentin which is comparable to established luting agents.

Coloring Agents↗

In vitro fracture resistance and marginal adaptation of metallic and tooth-coloured post systems.

The aim of this in vitro study was to compare the fracture resistance and marginal adaptation of all-ceramic incisor crowns with all-ceramic posts, glass-fibre-reinforced posts and titanium posts as well as a control without any post. Three groups of eight maxillary incisors were restored with an all-ceramic post, a fibre-reinforced composite (FRC) post, a titanium post and a further group was restored without posts. Composite cores were provided and all-ceramic crowns were adhesively luted. After artificial ageing, the fracture resistance of the restored teeth was determined. The marginal adaptation of the restorations at the interfaces between cement-tooth and cement-crown was evaluated with scanning electron microscopy using replica specimen before and after ageing. The restored teeth without posts [270N (235/335)] showed no significantly different fracture strength compared with teeth with the titanium system [340N (310/445)]. The all-ceramic posts [580N (425/820)] and the FRC posts [505N (500/610)] both provided a significant higher fracture resistance than the teeth without posts. Prior to ageing, all materials showed <5% separation at the margins cement-tooth or cement-crown ('marginal gap'). After ageing, the interfaces of all systems deteriorated to values between 6 and 14% marginal gap. The greatest marginal gap was found with the titanium system (14%) at the interface cement-crown and with the all-ceramic posts (12%) at the transition between cement-tooth. Regarding fracture resistance and the marginal adaptation, the all-ceramic and FRC posts may be considered as an alternative to the commonly used titanium post restorations.

Cementation↗

Fracture resistance of fiber-reinforced vs. non-fiber-reinforced composite molar crowns.

UNLABELLED: This study compared fracture resistance of fiber-reinforced and non-fiber-reinforced composite molar crowns under simulated oral stress conditions. Three groups of fiber-reinforced composite crowns were constructed using one polyethylene fiber (belleGlass/Connect) and two glass fiber reinforcement systems (Sculpture/FiberKor, Targis/Vectris). The non-fiber-reinforced crowns based on the facing material alone: Sculpture, Targis or belleGlass. Additionally, crowns were made of the non-reinforced composite Artglass. Each group consisted of eight crowns. All crowns were luted to human molars and exposed to thermal cycling and mechanical loading (6000 x 5 degrees C/55 degrees C; 1.2 x 10(6x)50 N; 1.66 Hz). The fracture resistance was measured using a Zwick universal testing machine. RESULTS: The non-reinforced Artglass crowns demonstrated the highest fracture resistance, significantly higher than the resistance shown with belleGlass, belleGlass/Connect or Targis. Artglass showed an extremely wide distribution of values, however. No statistically significant differences were found between the reinforced and non-reinforced composite crowns of Vectris/Targis, FiberKor/Sculpture or Connect/belleGlass although the reinforced crowns showed a tendency towards higher values. The fracture resistance values scattered markedly more for the reinforced crowns, and their lowest fracture values also reached the level of the lowest non-reinforced crowns. The small distribution of fracture values for the non-reinforced crowns indicates that they will be less susceptible for manufacturing faults and more reliable under clinical conditions. CONCLUSIONS: RESULTS of this study suggest that single molar composite crowns (tested in this study) do not benefit from fiber-reinforcement.

Analysis of Variance↗

Marginal adaptation and fracture resistance of adhesively luted glass fibre-composite reinforced molar crowns with different inner crown surfaces.

OBJECTIVES: This study compared the influence of different inner crown surfaces on the fracture resistance and marginal adaptation of adhesively fixed glass fibre-reinforced molar crowns. MATERIALS AND METHODS: Vectris/Targis crowns were constructed with an inner framework of glass fibres (directly on the tooth) or an inner veneering composite layer between the fibre-framework and the tooth-substance. Both groups were sandblasted inside using Al(2)O(3); 50 microm grain size (200 kPa, 20 s) and silane coated. A control group had the inner fibre framework, but was neither sandblasted nor silane coated. The crowns were adhesively cemented on extracted human teeth, and thermally cycled and mechanically loaded (TCML: 6000 x 5 degrees C/55 degrees C; 1.2 x 10(6) x 50 N, 1.66 Hz). The marginal adaptation before and after TCML was evaluated and the fracture resistance was investigated using a Zwick universal testing machine. RESULTS: After TCML the proportion of 'perfect margin' of the control group decreased significantly at the interface crown/cement. For the variations with an inner fibre framework or inner composite layer the marginal adaptation or fracture resistance did not decrease significantly after ageing. The fracture resistance values were control: 1509N+/-486; inner fibre framework: 1896N+/-342; inner composite layer: 1754N+/-340. CONCLUSIONS: In the case of the investigated fibre framework and veneering composite, the inner surface of glass fibre-reinforced molar crowns can be covered with a composite layer or with a glass fibre framework. Both methods achieve comparable high fracture strengths and reliable marginal adaptation.

Aluminum Oxide↗

Fixed partial dentures: all-ceramics, fibre-reinforced composites and experimental systems.

The aim of this in vitro study was to compare the fracture strength of three-unit FPDs (fixed partial dentures) and three-unit inlay FPDs after a simulated 5-year oral wearing period. The restorations were made of a pressable all-ceramic (Empress 2) and two specially designed, experimentally fixed partial dentures combining ceramics with dental composite. Three-unit FPDs and inlay FPDs were manufactured and were adhesively luted onto human molars. After thermal cycling and mechanical loading in an artificial environment, the fracture strength was determined. Zircon-based milled ceramic (Lava) three-unit FPDs were used as a control. The zircon ceramic and the fibre-based ceramic three-unit FPDs showed median fracture values between 1000 and 1400 N. For composite veneered zircon FPDs a fracture strength of about 800 N and for all-ceramic Empress 2 of about 350 N could be determined. The results for the inlay FPDs were between 1300 N and 1400 N for FRC/ceramic, 1000 N for zircon/composite and 500 N for all-ceramic restorations. The all-ceramic showed higher fracture resistance applied as inlay FPDs. The described hybrid techniques combining ceramics and composites could represent an interesting procedure for further investigations and, eventually, clinical implication.

Aluminum Silicates↗

Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures.

OBJECTIVES: The aim of this study was to evaluate the frequency of technical failure rates and the maintenance costs of clasp- or double crown-retained removable partial dentures (RPDs) (parallel-sided and conical double crowns). MATERIAL AND METHODS: According to three different retainer systems used between January 1992 to December 1998, three subgroups were randomly assigned from a group of 181 patients consisting of forty cases each. The average observation time was 4.2+/-1.7 years, with a minimum of 1.0 years and a maximum of 6.9 years. Technical complications such as fractures of the artificial teeth, loss of cementation, loss of facings as well as fractures of the metal framework and the soldering were recorded due to the medical reports. RESULTS: Twenty percent of all clasp-retained dentures showed technical complications during the observation period, whereas 50% of conical crown-retained (CC) and 32.5% of the parallel-sided retained dentures (PS) required repair. Most often reported was loss of cementation for double crowns (n=13, 32.5% PS; n=8, 20% CC) and fractures of the clasps (n=5). Although clasp-retained dentures had a markedly lower frequency of failures (n=8) than double crown systems (n=31), the calculated repair costs per event during the observation time were more than twice as high for clasp-retained dentures (172.5 Euro) than for double crown systems (8-78 Euro). The hypothesis that the maintenance costs of the more sophisticated double crown system are higher must be rejected.

Acrylic Resins↗

In vitro study of fracture strength and marginal adaptation of polyethylene-fibre-reinforced-composite versus glass-fibre-reinforced-composite fixed partial dentures.

This in vitro study was carried out in order to estimate the clinical usability of adhesively luted three-unit posterior fixed partial dentures (FPD) made of a polyethylene-fibre-reinforced-composite system (PFRC) in comparison with a glass-fibre-reinforced-composite system (GFRC). Therefore the fracture strength and marginal adaptation were examined. A total of 16 FPDs of each material combination were manufactured and adhesively luted to human molars. Before and after an artificial ageing process by thermal cycling and mechanical loading (TCML) the quality of the marginal adaptation was examined by evaluating epoxy replicas in a scanning electron microscope (SEM). After TCML the fracture strength of eight FPDs of each series was tested by mechanical loading them to failure. With the remaining eight FPDs the quality of deeper layers of the luting was examined with a dye penetration technique. The calculated median fracture strength values (25/75% percentiles) were 830 N (643/982) for the PFRC and 884 N (684/1,113) for the GFRC. The SEM analysis showed at least 80% of perfect marginal areas for both material combinations in dentine as well as in enamel before and after TCML. Looking at the cement-tooth interfaces the dye penetration technique showed statistically significant better results for the enamel finishing lines than for those in dentine. With finishing lines in dentine the two material combinations showed statistically significant differences for this interface. Fracture force results as well as marginal quality encourage further clinical investigations on both systems although the GFRC performed slightly better than the PFRC.

Cementation↗

Glass fiber-reinforced abutments for dental implants. A pilot study.

Titanium abutments in dental implants shine through all-ceramic crowns and therefore limit excellent esthetic results. Prototypes of tooth-colored fiber-reinforced abutments were investigated to avoid the shining-through effect. In vitro, the fracture strength was determined after thermal cycling and mechanical loading of all-ceramic single crowns and four-unit bridges made of a fiber-reinforced composite. The suprastructures were adhesively fixed onto fiber-reinforced implant abutments and compared with those fixed on standard titanium abutments. The median of the fracture strength of the titanium-supported all-ceramic crowns was significantly higher than the median of crowns fixed onto the prototypes. But this value was still more than twice as high as the maximum loading force under oral conditions. No statistical difference was found between four-unit bridges made by fiber-reinforced composite inserted onto titanium abutments and those inserted onto fiber-reinforced abutments. Fiber-reinforced abutment prototypes for dental implants avoided the shining-through effect associated with metal abutments. Their load-bearing capacity after in vitro stress simulation was higher than the maximum oral loading force. With some improvements, the fiber-reinforced implant abutments are therefore a promising alternative to titanium abutments.

Composite Resins↗

Glass-fibre-reinforced-composite fixed partial dentures on dental implants.

UNLABELLED: The objective was to investigate the fracture strength and marginal fit of implant suprastructures made of fibre-reinforced composite which were fixed onto the implants using cementation or screws. A sample (n=8) of 4-unit bridges, made of the fibre-reinforced composite Vectris/Targis, were adhesively cemented onto titanium conical implant abutments. The second sample consisted of eight screwable Vectris/Targis bridges which were based on prototypes of titanium crown bases. After a 5 year simulation of thermal cycling and mechanical loading (TCML), all specimen were loaded to fracture. Marginal fit was investigated using a semiquantitative SEM analysis. The cemented 4-unit bridges showed a fracture strength of 1553 N (Q1=1498 N, Q3=1825 N) and the screw-fixed bridges had a median of 1457 N (Q1=1223 N, Q3= 1781 N). The analysis of the marginal adaptation showed similar results of cemented and screwed bridges. The bond between the Targis facing-material and the composite cement was significantly deteriorated after TCML. CONCLUSION: Suprastructures made of glass-fibre-reinforced composite could become an alternative to reconstructions with a metal-framework. Both, fixation onto the implants with screws or cementation, are possible.

Composite Resins↗

Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies.

The objective was to investigate associations between the results of an in vitro and an in vivo study using an artificial mouth and a study of adhesive fixed partial dentures (AFPD) begun in 1985 [1]. Twenty extracted human molars and 20 human upper incisors were inserted into PMMA resin, 6 mm apart to represent a gap. Two preparation methods (identical to those in in vivo conditions) were used: a retentive preparation technique (posterior) and a non-retentive preparation technique (anterior). The frameworks of the bridges consisted of CoCr-alloy with a ceramic veneered pontic to replace the missing tooth. The bonding surfaces of the posterior AFPDs were conditioned with a tribochemical system, while the anterior AFPDs were sandblasted. All AFPDs were inserted using a dual curing composite cement. During thermal-cycling and mechanical loading (TCML: 6000 x 5 degrees C, 1.2 x 10(6) x 50 N, 1.66 Hz) in an artificial environment, the frequency and type of failures were observed. The above mentioned loading parameters were hypothesized to represent a period of 5 years under oral conditions. The results were compared to those of similar bridge-types in the in vivo study. The Kaplan-Meier estimations showed similar graphs for in vivo and in vitro with both types of AFPDs. In vivo and in vitro, the retentively prepared AFPDs were markedly more successful. With regard to the failure types, the simulation-parameters seemed to represent a loading stress that was comparable to in vivo conditions.

Acid Etching, Dental↗

Technical failure rates of double crown-retained removable partial dentures.

Removable partial dentures (RPD) can be retained using conical crowns or parallel-sided telescopic double crowns. The purpose of this study was to evaluate and compare the technical failure rate of the two retainer systems. One hundred seventeen dentures made by dentists of the medical school were included. Seventy-four RPD were retained with parallel-sided crowns (n = 251) and 43 with conical crowns (n = 160). Following the medical report follow-ups from January 1992 to December 1998, technical RPD failures were noted and analyzed. Technical problems occurred during the observation time in 48.8% of the conical retained dentures and 34.2% of the parallel-sided retained dentures. In both cases, loss of cementation was most frequently noted, while loss of the facings occurred only with conical crowns. Other technical failures did not depend on the type of retainer system used. These were most frequently problems with the denture base, e.g., fracture of artificial teeth or the metal framework. We conclude that there were different technical failures of both double crown retainer systems. These problems were not insignificant in number but treatable.

Cementation↗

Experimental design of FPD made of all-ceramics and fibre-reinforced composite.

OBJECTIVES: This study was carried out to combine flexural properties of FRC materials with aesthetic values of ceramics. METHODS: The bonding strength of fibre-reinforced composite to ceramic was determined. Afterwards, 8 three unit and 8 four unit FPDs (fixed partial dentures) were manufactured based on the experimental design and were then adhesively luted onto human molars. After thermal cycling and mechanical loading in an artificial environment, the fracture strength and marginal adaptation was determined. FPDs made of FRC (fibre-reinforced composite) materials were used as a control. RESULTS: The most reliable bonding strength of ceramic to FRC material was achieved using acid etching in combination with adhesive luting techniques. Median fracture strength values of 575 N for three unit FPD and 876 N for four unit FPD were established. More than 85% of the experimental FPDs showed a perfect margin while less than 15% revealed a marginal gap, even after thermal cycling and mechanical loading (TCML). The strongest influence of TCML on the marginal adaptation of the experimental design FPD was determined within the four unit system showing approximately a 10% change in marginal gap and perfect margin. SIGNIFICANCE: Assuming an improvement in adhesive bonding between the ceramic and the FRC material and, in addition, an enhancement of the contact surface between pontic and abutment, the hybrid technique could represent an interesting procedure for further investigations and, eventually, clinical implication.

Acid Etching, Dental↗

Flexural properties of fiber reinforced composite using a vacuum/pressure or a manual adaptation manufacturing process.

PURPOSE: This study investigated the influence of fiber content and water storage on the flexural strength of beams made of two fiber-reinforced composites (FRC), the Vectris and the FibreKor system. MATERIAL AND METHODS: A manual adaptation method (FibreKor, n=30) and a vacuum/pressure process (Vectris, n=30) were compared using 25x4x2mm(3) beams. One group of the Vectris (n=10) and the FibreKor beams (n=10) was stored in water for 24h, a further group was thermal-cycled (TC) 6000x5 degrees C/55 degrees C, and a third group was stored in water for 30days at 37 degrees C. All beams were then loaded to failure using a three-point bending test and the flexural strength was calculated. Finally, the fiber volume percent (vol%) was determined. RESULTS: Generally, the flexural strength decreased significantly with increasing storage time independent of the investigated fiber- and/or manufacturing system. With the parameters 24h/TC/30days, the mean of flexural strength for the Vectris beams was 618/579/545N/mm(2), and for FibreKor 585/534/499N/mm(2). A fiber content of 28.1+/-0.4vol% was assessed for the Vectris beams and 12.8+/-0.6vol% for the FibreKor beams. After 24h storage in water, the Vectris and the FibreKor beams demonstrated a statistically significant higher flexural strength than after 30days storage in water. CONCLUSIONS: A vacuum/pressure manufacturing process in contrast to manual adaptation, resulted in a markedly higher fiber content, but did not necessarily lead to significantly higher flexural strength. Not only the fiber content, but also matrix composition as well as the bond between fibers and matrix determined the properties of FRC.

Analysis of Variance↗