What range of programmable AV delays is necessary in antibradycardia DDD stimulation?

DDD pacemakers differ considerably in device specific extents of AV delay (AVD) programmability. To demonstrate the requirements of a mean DDD pacemaker patient population optimal AVDs in 200 DDD pacemaker patients (age 8 to 91 years) were estimated by left atrial electrography. The results should help to define an AVD programmability standard. Left atrial electrograms were recorded via a bipolar filtered esophageal lead. The method aims on adjusting the left atrial electrogram to 70 ms prior to the ventricular spike, both during VDD and DDD operation of the pacemaker. In atrial sensed stimulation the optimal AVD varied from 40 to 205 ms (100.5 +/- 24.5 ms) and in atrial paced stimulation from 85 to 245 ms (169.1 +/- 24.5 ms). The difference of the mean values is statistically significant (p < 0.001). The difference between both values in the individual patient, the individual AVD correction time, varied from 0 to 170 ms (68.7 +/- 26.6 ms). Thus, from our findings requirements on AV delay programmability standard can be derived: AVDs (1) should have a range from 40 to 250 ms, (2) should be independently programmable during atrial sensed and atrial paced operation, and (3) should provide as nominal settings 100 ms for atrial sensed and 170 ms for atrial paced stimulation.

Aged↗

Exercise induced sympathetic influences do not change interatrial conduction times in VDD and DDD pacing.

Using telemetry, right atrial electrogram (RA), and marker channel of atrial sense events (MA) in combination with the left atrial electrogram (LA), recorded by a filtered bipolar esophageal lead, interatrial conduction during submaximal exercise and at rest was examined in 46 DDD pacemaker patients. The RA-LA and MA-LA conduction times measured in the presence of atrial sensing (VDD) as well as the conduction time SA-LA from atrial stimulus (SA) to LA, determined during atrial pacing (DDD) were found to be individual constants independent of exercise induced sympathetic influences. Thus, having determined an optimal mechanical interval (LA-LV)mech/opt from left atrium to ventricle by other methods, the optimal AV delay for DDD as well as for VDD operation can be calculated by the sum of the appropriate interatrial conduction time (SA-LA, respectively MA-LA) and the (LA-LV)mech/opt interval. Due to the constant SA-LA and MA-LA, the difference between these two values (AV delay correction interval) is a constant as well, which remains unchanged during exercise. Therefore, in selecting the rate responsive AV delay, only hemodynamic and not electrophysiological measurements need to be considered.

Aged↗

Orthodromic and antidromic pacemaker circus movement tachycardia.

Pacemaker circus movement tachycardia (PCMT) during DDD pacing is usually sustained by retrograde natural and antegrade electronic atrioventricular (AV) conduction. As PCMT is often initiated by a ventricular premature beat (VPB) one method of its prevention is the programming of an atrial stimulus synchronously following a ventricular extrasystole. A patient is described with preserved antegrade, but without retrograde, i.e., VA, conduction. The optional pacemaker mode of synchronous atrial stimulation following a VPB caused an unusual PCMT sustained by retrograde electronic and antegrade natural AV conduction. This PCMT is similar to a natural reentry tachycardia, the most common variety of which (based on retrograde conduction) is termed antidromic and that which we describe is orthodromic.

Adult↗