Search PubMed⌕ Search

Biomedical subjects

G H Dibdin

Publications and source records attributed to G H Dibdin.

At least 37 records · Page 2Linked to original sources

The interpretation of CO2 equilibration data to obtain plaque fluid buffer capacities, and comparison with results obtained by titration.

Titration measurements of pooled plaque fluid buffering capacity (Shellis and Dibdin, 1988), which showed a broadly defined minimum at pH 7, were compared with recent curves published by Carey et al. (1988a), which they obtained by an ultra-micro CO2-equilibration technique and which suggested a quite different profile, peaking sharply at pH 7.1. When analyzed in a different, more conventional way, the raw measurements in the latter study become more consistent with our own results and with earlier findings of Tatevossian (1977). In particular, we conclude that the peak at pH 7.1 is an artifact, and that Carey et al. underestimated buffer capacities below pH 6.4 and above pH 7.4. Rationales for the two modes of analysis are compared, and possible reasons for the remaining differences between the re-analyzed CO2-equilibration results and the titration results are discussed. Suggestions for the improvement of the accuracy of the CO2-equilibration technique are put forward.

Bicarbonates↗

Estimation of the velocity of the salivary film at some different locations in the mouth.

Previously, we studied the clearance rates of KCl from agarose gels positioned at different locations in the mouth, and showed that the rates were much slower than when clearance was into a well-stirred solution. We designed the present in vitro study to test the effect on KCl clearance of the velocity of a 0.1-mm-thick film of water flowing over an agarose gel of the same diameter and composition as those used in vivo. The thickness of the salivary film overlying dental plaque has been estimated to be about 0.1 mm, and we assumed that when clearance rates in vitro matched those found in vivo, velocities of the fluid film (in vitro) and the salivary film (in vivo) must be equal. On this basis, it was calculated in the present experiments that when salivary flow was unstimulated, the velocity of the salivary film at the level of the teeth varied between about 0.8 mm/min (upper-anterior buccal region) and 8.0 mm/min (lower-anterior lingual region). When salivary flow was stimulated, this was estimated to increase the velocity of the salivary film from 2 to 40 times, depending on the location in the mouth. It is postulated that the slow movement of the salivary film when flow is unstimulated allows for accumulation of diffusants from dental plaque, which reduces the concentration gradient for diffusion from plaque and prolongs the clearance time of such metabolic products as acid.

Chemical Phenomena↗

Analysis of the buffering systems in dental plaque.

A semi-micro method was used for investigation of the buffering properties of whole plaque, plaque fluid, and washed plaque bacteria. Artifacts associated with titration of samples containing live bacteria were noted and their effects estimated. All three sample types showed minimal buffering in the region of neutrality, with much stronger buffering in the regions pH 4-5.5 and pH 8-9. For the range pH 4-7, almost 90% of the total buffer capacity of plaque appeared to be accounted for by macromolecules of bacterial cell walls and plaque matrix. Extracellular buffers in plaque fluid removable by centrifugation contributed up to 11%. These buffers (probably soluble proteins, peptides, organic acids, and phosphate) are, potentially at least, capable of exchange with saliva. In vitro, bicarbonate (dissolved in the extracellular fluid) contributed only 2-5% of total buffering; there was no evidence of formation of carbamino compounds. However, in vivo, salivary bicarbonate may be important as a continually replenished source of additional buffering.

Adult↗

Physical and biochemical studies of Streptococcus mutans sediments suggest new factors linking the cariogenicity of plaque with its extracellular polysaccharide content.

Cultures of Streptococcus mutans MFe28 (serotype h) were grown with differing extracellular polysaccharide (EPS) content. Biochemical and physicochemical characteristics considered relevant to caries were measured. Acid production parameters measured in a pH-stat were: Vm = 0.76 +/- 0.14 mumol/g/sec (wet weight); apparent Km (acid production) = 100 mumol/L; molar yield = 1.97 +/- 0.25 mol acid/mol glucose. Acid anion inhibition of acid production was also noted. Buffering by the pure washed bacterial residue required approx. 112 mumol of base/g (wet weight) of residue to change the pH from 4 to 6.5, and this dropped almost to zero as the EPS content increased to 100%. Diffusion coefficients (D) in the residues were independent of EPS content over a wide range. When the effusion method was used, De (glucose) and De (acetate) were (3.26 +/- 0.6) and (5.05 +/- 0.8) x 10(-6) cm2/sec, respectively. The extracellular fluid fraction, measured by inulin exclusion, increased from 0.33 for the pure bacteria to 0.78 for the pure EPS. It is shown how, by these factors alone, and without any need for diffusion restriction, plaque EPS may lead to a lower pH at the tooth surface, thus increasing the cariogenic challenge.

Chemical Phenomena↗

A theoretical analysis of the effects of plaque thickness and initial salivary sucrose concentration on diffusion of sucrose into dental plaque and its conversion to acid during salivary clearance.

A mathematical model, written in FORTRAN, has been developed to simulate the interrelated processes of salivary sucrose clearance from the mouth, diffusion of sucrose into dental plaque, and conversion of sucrose to acid and glucan. Reaction of acid with enamel is not included in the model. A total of 28 parameters can be varied by the user, and the relative importance of the different factors affecting acid formation can be assessed. The output of the program gives sucrose and acid concentrations and pH at different depths within the plaque. The initial variables studied were plaque thickness, the salivary sucrose concentration, and the duration of exposure of the plaque to sucrose. Stephan curves typical of those recorded in vivo were generated by the model. With any particular salivary sucrose concentration, there was an optimum plaque thickness at which a minimum pH was achieved at the enamel surface, with very thin or thick plaque samples producing a smaller pH fall. With thick plaque, the minimum pH was often not achieved at the inner surface but at some intermediate depth, which may explain the location of early caries lesions in fissures. The extent of the pH fall at the inner surface and the duration of the pH-minimum region of the Stephan curve were directly related to the initial salivary sucrose concentration and to the duration of exposure to sucrose prior to normal salivary clearance. Simulation of a water rinse at as short a time as two min after the beginning of normal salivary sugar clearance showed that this procedure had only a very small effect on the shape of the Stephan curve.(ABSTRACT TRUNCATED AT 250 WORDS)

Acetates↗

A comparison of the potassium content and osmolality of plaque fluid and saliva, and the effects of plaque storage.

Previous determinations of osmolality and potassium concentrations in plaque fluid, much higher than those in saliva, suggest a restricted exchange between the two, which must be reconciled with recent findings of quite rapid diffusion in plaque. Possible reasons for the high values were considered, and of these the effect of solute leakage from bacteria to the plaque fluid during typical periods of storage was investigated. It was also shown that the osmotic pressure of plaque fluid could be measured quite accurately by vapor pressure osmometry on whole plaque samples without the need for centrifugation. Samples of plaque, or plaque fluid prepared by centrifugation at 12,000 g, were compared for osmolality or potassium content with matched samples prepared from plaque stored chilled or in liquid nitrogen. Saliva samples obtained just prior to plaque collection were also analyzed. Freshly collected plaque from overnight-fasted subjects had a plaque fluid osmolality of 156 +/- 35 as compared with 98 +/- 23 mOs/kg for saliva. Potassium in plaque fluid from freshly collected "mature" plaque was 40.6 +/- 5.1 as compared with 20.3 +/- 5.3 mmol/L for saliva, but for 1-2-day-old plaque from fasted subjects it was significantly lower (30.4 +/- 5.6 mmol/L). These values for plaque fluid are all much less than those previously found, and storage was found to cause a marked increase (range, 35-100%). Centrifugation at 12,000 g caused little change in plaque fluid osmolality but seemed to accelerate the rate of increase during subsequent storage.

Adult↗

Effect of inoculation sequence and nutrients upon Streptococcus mutans BHT and Streptococcus mitior LPA-1 growing on human teeth in an artificial mouth.

Human teeth in an artificial mouth were inoculated with Streptococcus mutans BHT, Streptococcus mitior LPA-1, or sequentially with both organisms. Incubation was continued for 90 h. Mixed populations were largest when a nutrient supplement containing 5.0% (w/v) sucrose was supplied. Fewer organisms were recovered from experiments with synthetic saliva only, or when a supplement containing 0.05% (w/v) glucose was available. The inoculation sequence determined the total viable count and a larger population resulted when Strep. mutans was the initial colonizer (P less than 0.01). Strep. mutans was always able to become established even when super-infected on to a 24 h plaque of Strep. mitior. The final proportion of Strep mutans was lower when it was the superinfecting organism and the sucrose (P less than 0.01) or glucose (P less than 0.05) nutrient supplement was provided. This work confirms the importance of inoculation sequence and presence of sugars in plaque accumulation and demonstrates the fundamental role of microbial interactions in this process.

Ecology↗

Surface area and pore size analysis for human enamel and dentine by water vapour sorption.

The water sorption apparatus described allowed water sorption isotherms to be plotted on several samples simultaneously, with the added possibility of recording their nuclear magnetic resonance spectra for any points on the isotherm. Water sorption showed that human dentine had a saturated water content (removable in vacuo at room temperature) of approx. 10 per cent w/w (21 per cent v/v), probably in micropores or associated with the organic phase, and a specific surface of approx. 150 m2/g. A similarly measured water content for outer enamel was approx. 0.9 per cent w/w (2.7 per cent v/v), with a specific surface of 5.5 m2/g. For whole enamel, the slightly larger values of 1.15 per cent w/w (3.4 per cent v/v) and 8.7 m2/g were obtained. Results are shown to depend upon the conditions of measurement. Pore-size distribution analysis of enamel and dentine by water sorption, in this study and in investigations by others, is shown to be subject to many uncertainties and of doubtful value. Some uncertainty is also believed to apply to surface area measurements.

Adsorption↗

Structure and porosity of human cervical enamel studied by polarizing microscopy and transmission electron microscopy.

Dehydration by alcohols and concentrated solutions of highly soluble salts caused refractive changes in enamel which were enhanced in the cervical regions. Electron microscopy showed crystals in cervical enamel to vary from normal orientation, size and habit to marked disorientation and reduced size. Consequent increases in surface area and inter-crystalline volume could account for the exaggerated optical behaviour. The changes in optical properties of enamel occurred only when the osmotic pressures of the imbibing solutions exceeded 500 atm. It is proposed that the internal pore system may take up water freely but exclude large hydrated molecules and ions which thereby create a negative pressure on the water contained in these pores. Once this negative pressure exceeds the tensile strength of the water-pore system, molecules may be torn from their attachment sites, and possibly from each other, so that a sudden evacuation of the pores is accompanied by a simultaneous reduction in refractive index. It is likely that such sudden evacuation would alter the potential of the pore surfaces to react with small molecules and ions subsequently invading the tissue.

Absorption↗

Gas chromatography of volatile fatty acids. Method involving separation from biological material by vacuum distillation.

A method is described for the quantitation of C2-C5 volatile fatty acids present in biological tissues. It involved recovery of the acids from their biological matrix by vacuum micro-distillation at room temperature, followed by gas phase separation of aqueous solutions on orthophosphoric acid-modified Phasepak Q columns. The subsequent gas chromatographic procedure resolved iso from normal isomers and showed a linear response for each volatile acid over the range 10-400 ng. There was no evidence of ghosting, isomer peak broadening, or peak tailing. Relative molar response values were shown to be linear with carbon number for all the volatile fatty acids studied.

Carbon↗

An intra-oral telemetry system for the continuous recording of vertical jaw movement.

Continuous measurement of the separation between upper and lower dental arches, the so-called interocclusal distance (10D), is of interest in dentistry. Criteria for making such measurements by radio telemetry are discussed. It is concluded that a transmitter small enough to fit in a molar tooth gap is necessary in order to minimize interference with normal function; other design factors are related to obtaining adequate frequency stability, on which measurement accuracy depends. A transmitter fulfilling these requirements is described which sensed the instantaneous value of 10D by the frequency change produced when a metallic object (dental filling, gold crown, shorted turn of wire or piece of ferrite) in one dental arch moved relative to the transmitter in the other. Errors due to lateral and protrusive jaw movements were measured. Careful design and the use of high grade ceramic chip capacitors resulted in a transmitter of good frequency stability (+/- 0.03% in 10 h, +/- 0.02%/degrees c) and small size (10 X 7 X 5 mm). An example is given illustrating 10D movements due to swallowing, speech and respiration.

Humans↗