On the contribution of volume currents to the total magnetic field resulting from the heart excitation process: a simulation study.

Data from a simulation study of volume current contribution to the total magnetic field produced in the heart excitation process is presented. Contributions from different tissue types are analyzed and effects of torso size are studied. A high resolution finite element model of an adult male torso composed of 19 tissue types is used. It has detailed description of tissue geometries and therefore is well suited for analyzing the contribution of the primary and secondary currents to the magnetic field. The computed results show major contribution of volume currents from blood, myocardium, and lungs and less significant contribution from liver, muscle, and other tissues. The contribution to the volume currents from the blood in the ventricles was highest. These simulations suggest that contribution to the total magnetic field due to volume currents flowing in tissues other than blood could be accounted for by simply multiplying the total field values by a constant. Values of these multipliers would be based on the tissue type and time in the excitation cycle. Effects of torso size on the computed magnetic fields are also evaluated. Our data shows that a torso extending approximately 3 cm above and below the heart produces field patterns similar to a larger torso model extending from top of guts to the bottom of neck. Thus a shorter torso model would be sufficient for cardiac magnetic field analysis. These results are of interest for future modeling of magnetocardiograms and solving the inverse problem.

Adult↗

An efficient tissue classifier for building patient-specific finite element models from X-ray CT images.

We developed an efficient semiautomatic tissue classifier for X-ray computed tomography (CT) images which can be used to build patient- or animal-specific finite element (FE) models for bioelectric studies. The classifier uses a gray scale histogram for each tissue type and three-dimensional (3-D) neighborhood information. A total of 537 CT images from four animals (pigs) were classified with an average accuracy of 96.5% compared to manual classification by a radiologist. The use of 3-D, as opposed to 2-D, information reduced the error rate by 78%. Models generated using minimal or full manual editing yielded substantially identical voltage profiles. For the purpose of calculating voltage gradients or current densities in specific tissues, such as the myocardium, the appropriate slices need to be fully edited, however. Our classifier offers an approach to building FE models from image information with a level of manual effort that can be adjusted to the need of the application.

Algorithms↗

Management of ventricular fibrillation with transvenous defibrillators without baseline electrophysiologic testing or antiarrhythmic drugs.

INTRODUCTION: Baseline electrophysiologic study (EPS) is routinely performed in patients resuscitated from ventricular fibrillation (VF) to risk stratify and select patients for chronic antiarrhythmic drug therapy. The role of EP testing prior to insertion of a multiprogrammable implantable cardioverter defibrillator (ICD), however, is unclear. METHODS AND RESULTS: This study was a retrospective review of outcome in 66 survivors of an initial episode of out-of-hospital VF not associated with a Q wave myocardial infarction or reversible causes, treated with transvenous ICDs as first-line therapy. Patients were excluded from the study if they had a previous history of monomorphic ventricular tachycardia (VT), a clinical history suggestive of supraventricular tachycardia, or had undergone preoperative EP testing. Fifty-two of the patients (79%) were male with an average age of 58 +/- 11 years. Coronary artery disease was present in 43 patients (66%), cardiomyopathy in 15 patients (23%), and valvular heart disease in 1 patient (1.5%). Seven patients (11%) had no detectable structural heart disease. The mean left ventricular ejection fraction was 0.40 +/- 0.16. With an average follow-up of 25 +/- 12 months, survival free of death from any cause was 100%. Twenty-three patients (35%) experienced 48 episodes of recurrent rapid VT or VF (average cycle length: 236 +/- 47 msec) treated by their device. The mean time to first therapy was 223 +/- 200 days. Only one of these patients also received antitachycardia pacing for two episodes of VT. One patient (1.5%) temporarily received amiodarone after removal of an infected device that was subsequently replaced. No other patient received antiarrhythmic drug therapy. CONCLUSION: After a cardiac arrest due to primary VF, select patients treated with multiprogrammable ICDs can be managed successfully without baseline EPS or antiarrhythmic drug therapy.

Aged↗

Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. Active Can Investigators.

OBJECTIVES: The purpose of this study was to prospectively examine in a multicenter study the methods of use, efficacy and complications of a unipolar cardioverter-defibrillator in patients at risk for sudden cardiac death. BACKGROUND: Implantation of cardioverter-defibrillators in the pectoral region offers a significant opportunity to improve the management of patients with life-threatening arrhythmias. Unipolar, single-lead, pectoral implantable cardioverter-defibrillators might decrease related mortality, morbidity and costs in the care of such patients. METHODS: From November 3, 1993 to May 8, 1995, a unipolar defibrillator (Medtronic model 7219C) was selected for use in 473 patients from 74 centers (386 [82%] men, 87 [18%] women; mean [+/- SD] age 59 +/- 13 years, range 16 to 88). The clinical indication for use was ventricular fibrillation in 157 patients, sustained ventricular tachycardia in 236, both ventricular tachycardia and ventricular fibrillation in 53 and syncope or inducible ventricular tachycardia/ventricular fibrillation in 27. Coronary artery disease was present in 323 patients (68%). The mean left ventricular ejection fraction was 0.36 +/- 0.15 (range 0.10 to 0.85). The distribution of New York Heart Association congestive heart failure was class I = 34%; class II = 45%; class III = 17%; and class IV = 2%. RESULTS: The unipolar cardioverter-defibrillator was inserted successfully in 464 (98%) of 473 candidates. Effective defibrillation occurred with the first shock polarity tested in 88% of patients, after a polarity switch in 8% and after lead or generator repositioning in 2%. The stored energy defibrillation threshold was obtained at implantation in 339 patients (72%) and was 11.5 +/- 6.1 J, with 72% of patients having a defibrillation threshold < or = 12 J. The mean "skin-to-skin" implantation time was 96 +/- 45 min (range 25 to 335 min). Complications occurred in 29 patients (6%). Device therapy for 2,160 spontaneous ventricular tachycardia or fibrillation episodes occurred in 128 patients (27%) over a 2,732 device-month experience (range 0 to 17.2) and was effective in 98.7% of episodes. There were 14 deaths (10 nonsudden cardiac, 3 sudden cardiac, 1 noncardiac). Cumulative survival, on an intention-to-treat basis from all causes of death at 17.2 months, was 94.4%. CONCLUSIONS: Unipolar pectoral implantable cardioverter-defibrillators can be inserted with a high likelihood of success in a relatively brief procedure. Defibrillation thresholds are low, morbidity is modest, and survival rates are good with this new type of implantable cardioverter-defibrillator.

Cardiac Pacing, Artificial↗

A prospective randomized evaluation of implantable cardioverter-defibrillator size on unipolar defibrillation system efficacy.

BACKGROUND: The active can unipolar implantable cardioverter-defibrillator (ICD) has been shown to defibrillate efficiently, but its current 80-cc size limits use in the pectoral position in many patients. Decreasing can size will facilitate pectoral insertion and will soon be feasible as an inevitable consequence of technological advancements. However, decreasing the can size has the potential to compromise unipolar defibrillation efficacy. It is the purpose of this study, therefore, to prospectively and randomly compare unipolar defibrillation efficacy with 80-cc, 60-cc, and 40-cc can sizes in patients immediately before ICD surgery in anticipation of advances in technology that will make smaller ICDs possible. METHODS AND RESULTS: Twenty-four consecutive patients underwent prospective, randomized evaluation of the effect of ICD can size on defibrillation efficacy during standard ICD surgery. Each patient had the unipolar defibrillation threshold (DFT) measured with 80-cc, 60-cc, or 40-cc active can placed in the left subcutaneous infraclavicular region. The system included a 10.5F tripolar right ventricular electrode that served as the shock anode. The shock waveform used in each instance was a single capacitor biphasic 65% pulse delivered from a 120-microF capacitor. Stored energy at the DFT for the 80-cc, 60-cc, and 40-cc cans were 8.1 +/- 4.7 J, 8.7 +/- 5.8 J, and 9.5 +/- 4.8 J, respectively. There was no statistical significant difference between the DFTs for the three unipolar can electrodes (P = 39). Leading edge voltage also did not differ significantly among the three unipolar cans (356 +/- 92 V, 365 +/- 110 V, and 387 +/- 94 V, respectively, P = .29). There was, however, a slight progressive increase in resistance with decreasing can size (57 +/- 7 omega, 60 +/- 9 omega, and 65 +/- 9 omega, respectively, P < .001). CONCLUSIONS: Decreasing can volume from 80 cc to 60 cc to 40 cc does not compromise unipolar defibrillation efficacy despite a slight rise in shock resistance. These findings indicate that technological advances that allow for smaller-volume ICDs will not compromise defibrillation efficacy for unipolar systems.

Defibrillators, Implantable↗

Transthoracic defibrillation of swine with monophasic and biphasic waveforms.

BACKGROUND: Biphasic waveforms have had a favorable impact on internal defibrillation but have seen minimal use in transthoracic defibrillation systems. The purpose of this study was to compare monophasic and biphasic waveforms for transthoracic defibrillation in swine. METHODS AND RESULTS: Three interrelated studies were performed in 19 swine to establish the relative transthoracic defibrillation efficacy of biphasic shock waveforms. In study 1, we measured voltage (V50) and energy (E50) strength-duration curves for monophasic and biphasic truncated exponential waveforms. We then independently examined the effects of phase duration and tilt on biphasic waveform defibrillation with a total waveform duration from study 1 that provided the minimum V50 (study 2) and the minimum E50 (study 3). At each pulse duration tested in study 1, biphasic waveforms defibrillated with significantly less voltage and energy than monophasic waveforms. At a duration of 12 ms, there was a voltage minimum for biphasic waveform defibrillation. At this duration, V50 was 1378 +/- 505 V for the biphasic waveform compared with 2185 +/- 361 V for the monophasic waveform, P = .01. For both monophasic and biphasic waveforms, E50 increased with pulse duration. With a total pulse duration of 12 ms, E50 was 169 +/- 101 J for the biphasic waveform compared with 414 +/- 114 J for the monophasic waveform, P = .003. In study 2, optimization of phase duration and total tilt reduced the defibrillation requirements of the 12-ms "minimum voltage" biphasic waveform to 1284 +/- 187 V and 129 +/- 36 J. In study 3, the 8-ms "minimum energy" biphasic waveform had an E50 of 115 +/- 35 J that was 11% less than the 12-ms biphasic waveform, P = .11; however, voltage requirements of 1476 +/- 239 V were 15% higher, P = .005. CONCLUSIONS: This study demonstrates the superiority of truncated biphasic waveforms over truncated monophasic waveforms for transthoracic defibrillation of swine. Biphasic waveforms should prove as advantageous at reducing voltage and energy requirements for transthoracic defibrillation as they have for internal defibrillation.

Animals↗

Ventricular arrhythmias detected after transvenous defibrillator implantation in patients with a clinical history of only ventricular fibrillation. Implications for use of implantable defibrillator.

BACKGROUND: Patients with a history of ventricular fibrillation (VF) have been shown to have a clinical profile, response to electrophysiological testing (EPS), and response to antiarrhythmic therapy that distinguishes them from patients with a history of sustained monomorphic ventricular tachycardia (MVT). Despite these differences, it is not clear whether VF in these patients is triggered by MVT or occurs de novo. The incidence of MVT and VF in such patients after their index VF event has important implications for therapeutic decisions regarding implantable defibrillator selection and programming. METHODS AND RESULTS: The records of 111 consecutive patients who had undergone transvenous cardioverter/defibrillator (ICD) implantation for malignant ventricular arrhythmias were reviewed retrospectively. For each patient, all device tachyarrhythmia detections were examined and classified as VF, MVT, rapid polymorphic VT, or other. The number of events, time to first arrhythmia detection, and cycle length of MVTs were recorded. There were 55 patients with a history of only VF and 56 with a history that included an episode of MVT. Over 14 months of follow-up, with all patients initially off of antiarrhythmic medications, MVT was detected by only 18% of patients with a history of only VF compared with 54% of those with a history that included MVT (P = .002). Among patients who did detect MVT, those with a history of only VF had fewer episodes (7 +/- 7 versus 20 +/- 31, P = .001) and a shorter mean MVT cycle length (279 versus 314 ms, P = .03) than those with a clinical history of MVT. Abrupt onset of VF not preceded by MVT was detected in 11% of patients with VF only. In addition to a history of MVT, male sex, age < 60 years, and MVT inducible on EPS were all significantly associated with an increased likelihood of MVT detection. On multivariate analysis, the inducibility of MVT was the primary independent predictor of MVT detection but was of minimal incremental predictive value in the subgroup of patients with a history of only VF. When EPS results were not considered, arrhythmia history was the primary independent predictor of MVT detection. CONCLUSIONS: Patients with a history of only VF infrequently have MVT detected by their defibrillators. When these patients do detect MVT, it is faster than that detected in patients with a clinical history of MVT before ICD surgery. A significant percentage of VF survivors detected the abrupt onset of VF not preceded by MVT, suggesting that the deterioration of rapid MVT to VF is not the only clinically important mechanism of VF induction. These findings may have important implications for the understanding of the mechanism of VF induction and for use of an implantable defibrillator.

Cardiac Pacing, Artificial↗

Truncated biphasic pulses for transthoracic defibrillation.

BACKGROUND: Early defibrillation is the single most important factor for improving out-of-hospital ventricular fibrillation resuscitation rates. To achieve the earlier response times required for survival, typically < 6 minutes from time of collapse, it will be necessary to equip a far wider network of first responders (firefighters, police, and other individuals with responsibility for public safety) with small, lightweight, and inexpensive automatic external defibrillators (AEDs). An important step in reducing the size and cost of AEDs will be to improve defibrillation efficacy. Because biphasic waveform defibrillation has had a favorable impact on implantable cardioverter-defibrillators (ICDs), there are reasons to believe that biphasic waveforms would also improve transthoracic defibrillators. Our purpose, therefore, was to examine the efficacy of two different low-energy biphasic truncated waveforms referenced to a standard damped sine waveform for transthoracic defibrillation in humans. METHODS AND RESULTS: We prospectively and randomly compared the transthoracic defibrillation efficacy of two different truncated biphasic waveforms, 115 J (70 microF) and 130 J (105 microF), with that of a standard 200-J (36-microF, 28-mH) damped sine wave pulse using right anterior and left lateral thoracic pads (R2 Medical Systems) in 30 cardiac arrest survivors during transvenous ICD surgery. The right anterior patch electrode was used as the cathode and the left lateral thoracic pad as the anode. Transthoracic ventricular defibrillation rescue shocks were tested after a failed transvenous defibrillation shock delivered in the course of ICD testing. Each of the three different rescue shocks was tested in random order in each patient. All shocks were delivered at end expiration. The investigators responsible for determining transthoracic shock efficacy were blinded throughout the study to the transthoracic rescue waveform used. A total of 33 patients were considered for study, but three patients failed to satisfy all entry criteria or did not have a sufficient number of ventricular fibrillation inductions to allow for testing of all three waveforms. Percent efficacy for the three waveforms was then compared in the 30 patients who satisfied entry criteria and completed the protocol. The study population had a mean age of 61 +/- 11 years, with 22 (73%) being men. The mean left ventricular ejection fraction was 0.39 +/- 0.14. Coronary artery disease was present in 22 (73%). The 115-J (70-microF) biphasic pulse, the 130-J (105-microF) biphasic pulse, and the 200-J (36-microF, 28-mH) damped sine wave pulse were equally effective, resulting in a 97% first-shock ventricular defibrillation efficacy rate. Each waveform failed to defibrillate once, with each waveform failing in a different patient. CONCLUSIONS: The results of this study suggest that biphasic truncated transthoracic shocks of low energy (115 and 130 J) are as effective as 200-J damped sine wave shocks used in standard transthoracic defibrillators. This finding may contribute significantly to the miniaturization and cost reduction of transthoracic defibrillators, which could enable the development of a new generation of AEDs appropriate for an expanded group of out-of-hospital first responders and, eventually, layperson use.

Adult↗

A prospective randomized comparison in humans of biphasic waveform 60-microF and 120-microF capacitance pulses using a unipolar defibrillation system.

BACKGROUND: Improving unipolar implantable cardioverter-defibrillator (ICD) effectiveness has favorable implications for ICD safety, efficacy, and size. Advances in defibrillation efficacy would accelerate ICD ease of use by decreasing device size and by minimizing morbidity and mortality related to an improved defibrillation safety margin. The specific purpose of the present study was to determine whether unipolar defibrillation efficacy could be improved further in humans by lowering biphasic waveform capacitance. METHODS AND RESULTS: We prospectively and randomly compared the defibrillation efficacy of a 60-microF and a 120-microF capacitance asymmetrical 65% tilt biphasic waveform using a unipolar defibrillation system in 38 consecutive cardiac arrest survivors before implantation of a presently available standard transvenous defibrillation system. The right ventricular defibrillation electrode had a 5-cm coil located on a 10.5F lead and was used as the anode. The system cathode was the electrically active 108-cm2 surface area shell (or "can") of a prototype titanium alloy pulse generator placed in a left infraclavicular pocket. The defibrillation pulse was derived from either a 60-microF or a 120-microF capacitance and was delivered from RV-->CAN. Defibrillation threshold (DFT) stored energy, delivered energy, leading-edge voltage and current, pulse resistance, and pulse width were measured for both capacitances examined. The 60-microF capacitance biphasic pulse resulted in a stored-energy DFT of 8.5 +/- 4.1 J and a delivered-energy DFT of 8.4 +/- 4.0 J. In 34 of 38 patients (89%), the stored-energy DFT was < 15 J. Leading-edge voltage at the DFT was 517 +/- 128 V. Mean pulse impedance for the 60-microF waveform was 60.6 +/- 7.1 omega. The 120-microF capacitance biphasic pulse resulted in a stored-energy DFT of 10.1 +/- 7.4 J and a delivered-energy DFT of 10.0 +/- 7.2 J (P = .13 and .13, respectively). In 28 of 38 patients (74%), the stored-energy DFT was < 15 J (P = .052). Leading-edge voltage at the DFT with the 120-microF capacitance pulse was 386 +/- 142 (P < .00001). Mean pulse impedance for the 120-microF waveform was 60.7 +/- 7.0 omega (P = .80). CONCLUSIONS: The results of the present study suggest that a relatively small capacitance, 60 microF, can be used for unipolar defibrillation systems without compromising defibrillation energy requirements compared with more typical ICD capacitance values, but this will require a higher circuit voltage. The use of lower capacitance also provides a modest increase in the percent of patients who have very low energy defibrillation requirements, an important issue should maximum ICD energy be decreased from the present level of 34 J. Such a move to smaller output devices could allow significant decreases in device size, a necessary feature of making cardioverter-defibrillator implantation comparable to that of standard pacemaker surgery.

Adult↗

Mechanical complications after implantation of multiple-lead nonthoracotomy defibrillator systems: implications for management and future system design.

Nonthoracotomy lead system (NTL) implantable cardioverter defibrillators (ICDs) provide excellent protection against sudden death from ventricular tachyarrhythmias. However, these devices have unique mechanical complications and management issues. We reviewed the major complications occurring in 159 patients who underwent attempted implantation of a multilead NTL system. Successful implantation was obtained in 98% of patients. Two-year, all-cause actuarial survival on an intention-to-treat basis was 94%. Major complications occurred in 28 (17.6%) patients over a follow-up period of 21 +/- 10 months. Complications included 11 (6.9%) lead dislodgements, 10 (5.7%) lead fractures in 9 patients, 2 (1.3%) pocket infections, 1 frozen shoulder, 1 right ventricular perforation, 1 pneumothorax, 1 bleed requiring transfusion, 1 thromboembolism, and 1 "twiddle"-induced torsion of leads. Most of the lead dislodgements and fractures were identified by routine x-ray surveillance. Single-lead systems may significantly reduce complication rates in the future and maintain excellent survival rates.

Actuarial Analysis↗

Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system.

OBJECTIVES: The purpose of this study was to determine the relation between clinical variables and the defibrillation threshold by using a standardized testing protocol and a uniform implantable defibrillator system. BACKGROUND: Past studied have not revealed useful correlations between clinical variables and the energy required to terminate ventricular fibrillation. Most of these studies did not use a uniform implantable defibrillator system or a standardized protocol to measure the defibrillation threshold and, thus, did not control for the influence of these technical influences. We postulated that defibrillator and defibrillation threshold measurement-based sources of variability overshadowed important clinical predictors. METHODS: The defibrillation threshold was measured by using a standardized protocol in 101 consecutive patients. We used a transvenous unipolar pectoral defibrillation system that employed a single endocardial right ventricular defibrillation coil as the anode and the shell of an 80-cm3 pulse generator as the cathode to deliver a 65% tilt biphasic pulse. RESULTS: Several clinical variables were found to be significantly associated with the defibrillation threshold: patient gender, height, weight, body surface area, heart rate at rest, QRS and corrected QT (QTc) intervals, left ventricular mass and several measures of heart and chest size by chest roentgenogram. None of these variables had a correlation coefficient > 0.45 with the defibrillation threshold. On multivariate analysis, left ventricular mass and heart rate at rest were the only independent predictors of the defibrillation threshold and explained only 25% of the observed variability. CONCLUSIONS: Despite the use of a uniform transvenous defibrillation system and a standardized protocol to measure the defibrillation threshold, no clinically relevant correlation was found between clinical variables and the defibrillation threshold. The defibrillation threshold is probably a function of a complex interaction of anatomic, physiologic and cellular variables that are not adequately represented by easily obtainable clinical information. It is probably not possible to predict defibrillation outcome from standard clinical variables.

Amiodarone↗

Transvenous defibrillator implantation in patients with persistent left superior vena cava and right superior vena cava atresia.

In this report a transvenous cardioverter defibrillator implantation is described in two patients with a persistent left-sided superior vena cava and right SVC atresia. In the first case, manoeuvring of the guide wire inserted through the left subclavian vein into the SVC proved impossible, revealing a left SVC originating from the left brachiocephalic vein with an acute corner. Changing the side of implantation and inserting a CPI Endotak catheter through the right subclavian vein, the lead was easily advanced through the left SVC into the coronary sinus and then into the right atrium with the tip abutting the lateral atrial wall. Subsequent manoeuvres allowed passage of the tip of the catheter into the right ventricular apex with the proximal defibrillation coil of the Endotak lead in the low left SVC, with its distal limit at the junction with the coronary sinus. A biphasic waveform single pathway RV - > left SVC successfully defibrillated with a stored energy of 5 J. In the second patient, implantation of a transvenous Medtronic system was possible from a left infraclavicular approach. A tripolar RV coil was inserted into the right ventricle via the persistent left SVC and contiguous coronary sinus. Because of the acute angle required to enter the RV in this second case, the RV lead was looped in the right atrium in order to enter the RV in a satisfactory, albeit atypical RV location. This patient was successfully defibrillated with a 5 J monophasic waveform delivered between the RV coil, a CS/left SVC coil, and a subcutaneous patch. In conclusion, both of these patients illustrate the ability to use transvenous ICDs successfully in patients with persistent left superior vena cava although the implantation technique deviates substantially from traditional methods.

Adolescent↗

Computational studies of transthoracic and transvenous defibrillation in a detailed 3-D human thorax model.

A method for constructing and solving detailed patient-specific 3-D finite element models of the human thorax is presented for use in defibrillation studies. The method utilizes the patient's own X-ray CT scan and a simplified meshing scheme to quickly and efficiently generate a model typically composed of approximately 400,000 elements. A parameter sensitivity study on one human thorax model to examine the effects of variation in assigned tissue resistivity values, level of anatomical detail included in the model, and number of CT slices used to produce the model is presented. Of the seven tissue types examined, the average left ventricular (LV) myocardial voltage gradient was most sensitive to the values of myocardial and blood resistivity. Incorrectly simplifying the model, for example modeling the heart as a homogeneous structure by ignoring the blood in the chambers, caused the average LV myocardial voltage gradient to increase by 12%. The sensitivity of the model to variations in electrode size and position was also examined. Small changes (< 2.0 cm) in electrode position caused average LV myocardial voltage gradient values to increase by up to 12%. We conclude that patient-specific 3-D finite element modeling of human thoracic electric fields is feasible and may reduce the empiric approach to insertion of implantable defibrillators and improve transthoracic defibrillation techniques.

Computer Simulation↗

Predicting cardiothoracic voltages during high energy shocks: methodology and comparison of experimental to finite element model data.

Finite element modeling has been used as a method to investigate the voltage distribution within the thorax during high energy shocks. However, there have been few quantitative methods developed to assess how well the calculations derived from the models correspond to measured voltages. In this paper, we present a methodology for recording thoracic voltages and the results of comparisons of these voltages to those predicted by finite element models. We constructed detailed 3-D subject-specific thorax models of six pigs based on their individual CT images. The models were correlated with the results of experiments conducted on the animals to measure the voltage distribution in the thorax at 52 locations during synchronized high energy shocks. One transthoracic and two transvenous electrode configurations were used in the study. The measured voltage values were compared to the model predictions resulting in a correlation coefficient of 0.927 +/- 0.036 (average +/- standard deviation) and a relative rms error of 22.13 +/- 5.99%. The model predictions of voltage gradient within the myocardium were also examined revealing differences in the percent of the myocardium above a threshold value for various electrode configurations and variability between individual animals. This variability reinforces the potential benefit of patient-specific modeling.

Animals↗

Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system.

BACKGROUND: A unipolar defibrillation system using a single right ventricular (RV) electrode and the active shell or container of an implantable cardioverter defibrillator situated in a left infraclavicular pocket has been shown to be as efficient in defibrillation as an epicardial lead system. Additional improvements in this system would have favorable practice implications and could derive from alterations in pulse waveform shape. The specific purpose of this study is to determine whether defibrillation efficacy can be improved further in humans by lowering biphasic waveform tilt. METHODS: We prospectively and randomly compared the defibrillation efficacy of a 50% and a 65% tilt asymmetric biphasic waveform using the unipolar defibrillation system in 15 consecutive cardiac arrest survivors prior to implantation of a presently available standard transvenous defibrillation system. The RV defibrillation electrode has a 5-cm coil located on a 10.5 French lead and was used as the anode. The system cathode was the active 108 cm2 surface area shell (or "CAN") of a prototype titanium alloy pulse generator placed in the left infraclavicular pocket. The defibrillation pulse derived from a 120-microF capacitor and was delivered from RV-->CAN, with RV positive with respect to the CAN during the initial portion of the cycle. Defibrillation threshold (DFT) stored energy, delivered energy, leading edge voltage and current, pulse resistance, and pulse width were measured for both tilts examined. RESULTS: The unipolar single lead system, RV-->CAN, using a 65% tilt biphasic pulse resulted in a stored energy DFT of 8.7 +/- 5.7 J and a delivered energy DFT of 7.6 +/- 5.0 J. In all 15 patients, stored and delivered energy DFTs were < 20 J. The 50% tilt biphasic pulse resulted in a stored energy DFT of 8.2 +/- 5.4 J and a delivered energy DFT of 6.1 +/- 4.0 J; P = 0.69 and 0.17, respectively. As with the 65% tilt pulse, all 15 patients had stored and delivered energy DFTs < 20 J. CONCLUSION: The unipolar single lead transvenous defibrillation system provides defibrillation at energy levels comparable to that reported with epicardial lead systems. This system is not improved by use of a 50% tilt biphasic waveform instead of a standard 65% tilt biphasic pulse.

Adolescent↗

Anatomical findings in patients having had a chronically indwelling coronary sinus defibrillation lead.

The purpose of this report is to review the gross and histological cardiac anatomical findings in patients with chronically indwelling coronary sinus leads at the time of autopsy or cardiac transplantation. Transvenous cardioverter defibrillators offer effective protection against sudden death. The use of a coronary sinus electrode has been shown in some patients to decrease the defibrillation threshold. The anatomical consequences of chronically indwelling coronary sinus cardioversion/defibrillation electrodes in patients having transvenous implantable cardioverter defibrillators is unknown. The hearts of seven patients with chronically indwelling coronary sinus electrodes were evaluated following autopsy (n = 2) or cardiac transplantation (n = 5). The coronary sinus electrode in each case was a 6.5 French silicone lead with a 5-cm long defibrillation coil (Medtronic CS lead model 6933) that was positioned as distally as possible within the coronary sinus at the time of implantable cardioverter defibrillator surgery. The seven hearts examined were derived from patients whose age ranged between 49 and 69 (mean 56 +/- 7 years). Six had coronary artery disease and one had idiopathic dilated cardiomyopathy. The time from implant to death or cardiac transplantation was 8 +/- 6 months, range 1-18 months. In all seven patients, there was no evidence of any significant damage from the presence of the coronary sinus lead. The only finding in each case was the scattered presence of a thin white fibrous sheath over the lead that intermittently adhered to the coronary sinus endothelium and, in the two patients transplanted 1-3 months after implantable cardioverter defibrillator insertion, a mild inflammation reaction adjacent to the leads in the coronary sinus endothelium. There was no evidence of coronary sinus occlusion, adjacent coronary artery injury, coronary sinus perforation, coronary sinus burn, or myocardial injury adjacent to the lead. Cause of death was due to end-stage congestive heart failure and thrombotic stroke, respectively, in the two patients examined at autopsy. Coronary sinus defibrillation leads can be used safely without harmful anatomical effect.

Aged↗

A prospective randomized comparison in humans of 90-mu F and 120-mu F biphasic pulse defibrillation using a unipolar defibrillation system.

INTRODUCTION: Capacitance is known to influence defibrillation. Optimal biphasic waveform capacitance for transvenous unipolar defibrillation systems in man is currently being defined. In an effort to improve defibrillation efficacy, we examined the relative defibrillation efficacy of a 65% tilt biphasic pulse from a 90-mu F capacitor compared to a 65% tilt biphasic pulse from a 120-mu F capacitor in a prospective, randomized fashion in 16 consecutive cardiac arrest survivors undergoing defibrillator surgery. METHODS AND RESULTS: The transvenous unipolar pectoral defibrillation system uses a single endocardial RV anodal defibrillation coil and the shell of an 80-cc volume (88 cm2 surface area) pulse generator (Medtronic Model 7219C PCD "active CAN") as the cathode for the first phase of the biphasic shock: RV+ --> CAN-. Defibrillation thresholds for each capacitance were determined prospectively in a randomized fashion. The defibrillation threshold results for the 90-mu F capacitance were: leading edge voltage 383 +/- 132 V; stored energy 7.4 +/- 5.0 J; and resistance 57 +/- 10 omega. The results for the 120-mu F capacitance were: leading edge voltage 315 +/- 93 V (P = 0.002); stored energy 6.5 +/- 3.7 J (P = 0.21); and resistance 57.0 +/- 11 omega (P = 0.87). CONCLUSIONS: We conclude that 90-mu F, 65% tilt biphasic pulses used with unipolar pectoral defibrillation systems have equivalent stored energy defibrillation efficacy compared to 120-mu F, 65% tilt pulses. Use of lower capacitance is possible in present implantable defibrillators without compromising defibrillation.

Adult↗