Search PubMed⌕ Search

Biomedical subjects

G Guiochon

Publications and source records attributed to G Guiochon.

At least 73 records · Page 4Linked to original sources

Experimental and theoretical study of the adsorption behavior and mass transfer kinetics of propranolol enantiomers on cellulase protein as the selector.

The thermodynamics and mass transfer kinetics of the retention of the R and S enantiomers of propranolol were investigated on a system comprising an acetic acid buffer solution as the mobile phase and the protein cellobiohydrolase I immobilized on silica as the stationary phase. The bi-Langmuir isotherm model fitted best to each set of single-component isotherm data. The monolayer capacity of the nonchiral type of adsorption sites was 22.9 mM. For the chiral type of sites, it was 0.24 mM for the R enantiomer and 0.64 mM for the S enantiomer. Peak tailing was observed, even at very low concentrations allowing operation of the low-capacity chiral sites under linear conditions. This tailing can be explained on the basis of heterogeneous mass transfer kinetics. At higher concentrations, which are often used in analytical applications, the isotherms on the chiral sites no longer have a linear behavior, and peak tailing is consequently more pronounced. Under those conditions, peak tailing originates from the combined effect of heterogeneous thermodynamics and heterogeneous mass transfer kinetics. These complex phenomena are explained and modeled using the transport-dispersive model with a solid film linear driving force model modified to account for heterogeneous mass transfer kinetics. The rate coefficient of the mass transfer kinetics was found to be concentration dependent.

Adsorption↗

Estimation of the number of enantioselective sites of bovine serum albumin using frontal chromatography.

On a column with bovine serum albumin (BSA) immobilized covalently to silica, the adsorption isotherms of the enantiomers of mandelic acid, tryptophan, 2-phenylbutyric acid, and N-benzoylalanine are measured using a buffered mobile phase. Knowing the amount of BSA immobilized on the column (36 mg), the ratio of the number of enantiomer molecules needed to saturate the enantioselective retention mechanism to the number of BSA molecules is determined. The mean of the set of eight enantiomers is 0.28. These data confirm that at most one enantioselective site exists for each BSA molecule for the kind of enantiomers studied.

Adsorption↗

Enantiomeric separations using bovine serum albumin immobilized on ion-exchange stationary phases.

Bovine serum albumin (BSA) can be readily immobilized on ion-exchange stationary phases by frontal analysis of a proper solution. This provides a simple means of adjusting the amount of BSA contained in the column and of measuring it accurately. Although the immobilization is ionic and not covalent, the columns are stable for extensive periods of time. If needed, they can be easily regenerated by the same frontal analysis procedure.

Animals↗

Contribution of ionically immobilized bovine serum albumin to the retention of enantiomers.

The retention of the enantiomers of mandelic acid and N-benzoylalanine was studied on columns prepared by immobilizing bovine serum albumin (BSA) on an anion exchanger. The amount of BSA fixed on the column is easy to adjust and measure. The adsorption isotherms were determined. For each enantiomer, the isotherm is well accounted for by a bi-Langmuir equation. One term of the isotherm (which is the same for both enantiomers) corresponds to non-selective interactions and the other term to the chiral selective interactions. The column saturation capacity of this second term is 8% larger for the less strongly retained enantiomer. This saturation capacity corresponds approximately to one enantiomer molecule adsorbed for five BSA molecules immobilized. This result is in agreement with the assumption of the hydrophobic cavity of BSA being the chiral selective site.

Alanine↗

Factors affecting the separation and loading capacity of proteins in preparative gradient elution high-performance liquid chromatography.

The optimum conditions for the purification of proteins by gradient elution in reversed-phase liquid chromatography were studied, with emphasis on the column length. Because of the strong dependence of the retention of proteins on the mobile phase composition, very short columns can be used successfully to perform analytical separations. A similar conclusion is extended to preparative separations. Columns with different lengths and diameters were used. The dependence of the loading capacity for touching band separation on the column length, diameter and volume was studied, in addition to the regeneration time between successive runs, the starting mobile phase composition and the necessary column efficiency.

Animals↗

Characterization of reversed-phase high-performance liquid chromatographic stationary phases using ribonuclease A.

The protein ribonuclease A (RNase A) represents a good model protein for studying reversible conformational refolding during gradient elution. Work is described utilizing RNase A under gradient conditions to evaluate several different reversed-phase materials. Columns (10 cm x 4.6 mm I.D.) were packed with Partisil C18, Vydac C18, Nucleosil C4, Nucleosil C18 and an adamantyl-modified Partisil silica. Measurements of the apparent first-order rate constant of refolding, as a function of temperature, are presented and compared for each stationary phase. Comparisons of peak shapes as functions of flow-rate and temperature are also discussed.

Chromatography, High Pressure Liquid↗

Applications of preparative high-performance liquid chromatography to the separation and purification of peptides and proteins.

The basic differences between the problems encountered in the development of the analytical and preparative applications of high-performance liquid chromatography are analyzed and the principles of optimization of a preparative separation outlined. The application of these principles to the purification of peptides and proteins are discussed with emphasis on the specific problems raised by the separation of high-molecular-mass compounds. The relative advantages and inconveniences of displacement and overloaded elution are presented. The applications of the various retention modes of liquid chromatography (ion exchange, reversed-phase adsorption, hydrophobic interactions, size exclusion and bioaffinity) to the separation of various peptide and protein mixtures and/or to the extraction and purification of some of these compounds are reviewed. Separation performance reported in the literature are summarized in table form.

Chromatography, High Pressure Liquid↗

Serum indole-3-acetic acid in control subjects and newly abstinent alcoholics after an oral loading with L-tryptophan: a preliminary study using liquid chromatography with amperometric detection.

Described in this paper is a rapid, isocratic assay for serum indole-3-acetic acid (IAA). The sample preparation involves only protein precipitation using sulfosalicylic acid, and the sensitivity of amperometric detection is in the picogram range. The chromatographic analysis time is approximately 4 min. The devised method was used for a longitudinal study of IAA levels in serum samples from control subjects and newly abstinent alcoholics. Dietary variations were eliminated by administering a 2.0-g loading dose of L-Trp to all subjects investigated. The results are presented in the form of cumulative frequency polygons. Preliminary data indicate no differences in IAA levels between newly abstinent alcoholics and control subjects.

Administration, Oral↗

Analytical methodology for assays of serum tryptophan metabolites in control subjects and newly abstinent alcoholics: preliminary investigation by liquid chromatography with amperometric detection.

A rapid, isocratic assay for the determination of all major tryptophan metabolites in serum samples from control non-alcoholic subjects, recovered alcoholics and newly abstinent alcoholics is described. The sample preparation involves only precipitation of protein with sulfosalicylic acid. The complete liquid chromatographic analysis is short (25 min) and the sensitivity of amperometric detection permits the routine assessment of catabolites at the picogram level. This preliminary longitudinal study of the basal and post-tryptophan load serum metabolites revealed a considerable scatter of experimental results for kynurenine and serotonin in all groups examined, probably owing to the clinical heterogeneity of the sample populations.

Adult↗

A strategy for source identification of organic pollutants in river water.

Sources of organic pollution in the Oise river, France have been identified using a "mutual search" strategy. This consisted of searching the characterized discharges for compounds found in the river water and, conversely, searching river water extracts for compounds found in the discharges. The "matches" were facilitated by comparisons of retention indices on two capillary gas chromatographic columns of widely differing polarity, response factors of selective detectors, and mass spectra. These assignments were verified by the geographical correlation of the selected pollutant's point of appearance in the river with the location of the suspected source.

Gas Chromatography-Mass Spectrometry↗

Mass transfer in chromatographic columns studied by PFG NMR.

Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) is applied to study convective and diffusional transport in chromatographic columns packed with totally porous support particles. Here stagnant zones exist in the particle pores, and diffusional mass-transfer limitations between fluid molecules diffusing in the intraparticle pore network and flowing in the interparticle void space are detected quantitatively. Axial displacement probability distributions were measured for water over a range of Peclet numbers and observation times, with diffusion lengths between 0.15 and 0.91 times the average support particle diameter. The transition towards complete diffusional exchange is demonstrated, thereby also revealing the development of the classical convective dispersion process in a packed bed of (porous) particles.

Candy↗

A study of mass transfer kinetics in an enantiomeric separation system using a polymeric imprinted stationary phase.

Chromatographic data pertaining to the enantioseparation of L- and D-phenylalanine anilide (PA) on a polymeric stationary phase imprinted with L-PA were studied from the viewpoints of phase equilibrium, mass transfer kinetics, and the thermodynamic properties of this enantiomeric separation system. The concentration dependence of the lumped mass transfer rate coefficient (k(m,L)) previously published was analyzed to obtain new information concerning the mass transfer characteristics in this chiral separation system. It was shown that intraparticle diffusion contributed much more to k(m,L) than adsorption/desorption. The positive concentration dependence of k(m,L) seemed to be interpreted by considering that of the surface diffusion coefficient, itself explained by the heterogeneous surface model. The characteristic features of the phase equilibrium, the mass transfer kinetics, and the thermodynamics of the enantiomeric separation system probably result from the adsorption energy distribution on the surface of the imprinted phase having an exponential decay.

Adsorption↗