Search PubMed⌕ Search

Biomedical subjects

G Gauglitz

Publications and source records attributed to G Gauglitz.

34 records · Page 2Linked to original sources

Label-free monitoring of DNA-ligand interactions.

We report on the label- and isotope-free monitoring of DNA interactions with low-molecular-weight ligands. An optical technique based on interference at thin layers was used to monitor in real time binding of ligands at DNA which was immobilized by Coulomb interactions at a positively charged surface. Approximately 2 ng DNA/m2 was irreversibly bound to the surface, which remained stable over several days. This result was confirmed by characterization of the layer using spectroscopic ellipsometry. During incubation of immobilized DNA with a variety of intercalators and other DNA-binding compounds in a flow system, interactions were monitored by reflectometric interference spectroscopy. Binding effects between 10 and 400 pg/ mm2 were detected unambiguously. Nonspecific binding effects were excluded by using a negatively charged reference surface. Variation of intercalator concentration allowed the characterization of interaction with respect to kinetics and thermodynamics by the evaluation of binding rate and equilibrium coverage. The affinity constants were determined in the range between 10(5) and 10(6) M-1, in good agreement to those obtained by homogeneous phase assays. Association rate constants between 10(3) and 10(5) M-1 s-1 and dissociation rate constants between 10(-1) and 10(-2) s-1 were determined by evaluation of the binding curves. Both the fast and simple test format and a universal applicability make the new technique described attractive for detecting and characterizing interaction of low-molecular-weight molecules with DNA.

DNA↗

Chiral discrimination using piezoelectric and optical gas sensors.

Odour perception in humans can sometimes discriminate different enantiomers of a chiral compound, such as limonene. Chiral discrimination represents one of the greatest challenges in attempts to devise selective and sensitive gas sensors. The importance of such discrimination for pharmacology is dear, as the physiological effect of enantiomers of drugs and other biologically active molecules may differ significantly. Here we describe two different sensor systems that are capable of recognizing different enantiomers and of qualitatively monitoring the enantiomeric composition of amino-acid derivatives and lactates in the gas phase. One sensor detects changes in mass, owing to binding of the compound being analysed (the 'analyte'), by thickness shear-mode resonance; the other detects changes in the thickness of a surface layer by reflectometric interference spectroscopys. Both devices use the two enantiomers of a chiral polymeric receptor, and offer rapid on-line detection of chiral species with high selectivity.

Alanine↗

Assessment of affinity constants by rapid solid phase detection of equilibrium binding in a flow system.

We present a method for the determination of affinity constants based on equilibrium binding between an analyte and an antibody in liquid phase by a heterogeneous phase detection scheme. Equilibrium concentration of free antibody binding sites was probed kinetically by direct optical detection of specific binding to an immobilised analyte derivative. The additional binding signal due to dissociation of the analyte-antibody complex during detection was minimised by the use of fast flow-through conditions. The concentration of free antibody binding sites was titrated by adding increasing analyte concentrations. The affinity constant was derived from the titration curve by a non-linear least square fit of a model function. The affinity of monoclonal triazine antibodies to several s-triazine pesticides and a relevant metabolite was investigated. Kinetic determination of equilibrium concentration of free binding sites was carried out by reflectometric interference spectroscopy (RIfS) using flow injection analysis. The capabilities of the model were investigated using different analyte-antibody pairs and various antibody concentrations. Both bivalent IgG and monovalent Fab fragments were used to compare different binding models. The applied model corresponds well to the titration curves for affinity constants of 10(7) M(-1) and higher. For lower affinity constants significant deviations due to dissociation of the analyte-antibody complex during detection were observed.

Animals↗

Specific binding of low molecular weight ligands with direct optical detection.

The characterization of low molecular weight ligand interaction with receptor molecules is of importance for the investigation of biological processes and for drug research. We report on the investigation of the binding of low molecular weight ligands to immobilized receptors by label-free detection. Reflectometric interference spectroscopy, an optical transducer which allows the monitoring of a few picograms per square millimetre changes in surface coverage, was used to study two model systems. In both cases detection of the binding event was successful. High affinity binding of biotin to immobilized streptavidin was clearly detectable at receptor surface concentrations as low as 1-2 x 10(10) binding sites/mm2. Linear correlation between the receptor surface concentration and the response to biotin binding was observed. Using immobilized DNA, we investigated the binding of common intercalators with respect to kinetics and thermodynamics by evaluation of the association and the dissociation part of the binding curve. Bi-exponential increase and decrease of intercalator loading was observed, indicating complex interaction kinetics. The four structurally different intercalators showed significant distinction in binding kinetics and equilibrium signals. Improvement of experimental parameters is required to obtain more reliable kinetic data.

Adsorption↗

Characterisation and optimisation of an immunoprobe for triazines.

The characterisation and optimisation of an optical immunoassay with label free detection based on Reflectometric Interference Spectroscopy (RIfS) is presented. The immunoprobe is operated in a sequential scheme, where Fab-fragments react with analyte molecules in a first step. In a second step the optical transducer is used to quantify the amount of unoccupied Fab- fragments in the reaction mixture binding to the hapten-modified transducer surface. For optimisation of the test, the Fab-fragment concentration was varied between 2x10(-8) mol/l and 2.5x 10(-9) mol/l. Down to a concentration of 5x10(-9) mol/l a reduction in the limit of detection has been observed. At the lowest concentration investigated no further improvement has been found due to a reduced binding of the analyte and a strong decrease of antibody binding at the transducer surface. This finding could be explained by the thermodynamics of the antigen-antibody reaction and the performance of the optical transducer used. The limit of detection obtained is discussed with respect to thermodynamics, transducer characteristics and immunoprobe test format.

Journal Article↗

Surface modification for direct immunoprobes.

The modification of glass-type surfaces by several hydrophilic polymers of different molecular masses and functional properties [chitosan, dextran, poly(oxyethylene), poly(ethyleneimine) and poply(acrylamide)] with respect to the application for direct immunoprobes was investigated. Activation of the surface was carried out by silanisation and the polymers were coupled to the surface via amide bonds. The carboxyl derivative of a hapten was attached to the functional groups of the polymers by carbodiimide-activated coupling. As a reference system, the ligand was directly coupled to the silanised surface. Non-specific protein adsorption, specific binding of antibodies and regeneration were monitored by evaluation of reflectance spectra obtained by white light interference at a thin silica layer (RifS). All polymer modified layers showed improved properties compared to those with direct attachment of the hapten. The non-specific adsorption was reduced to 5-50%. Binding of a specific antibody was significantly increased by the polymer modification: Mass transport limited binding of the specific antibody in low concentrations (30 nM) up to a surface coverage value of 2 ng/mm2 and a maximum surface coverage in the range of a monolayer of IgG (5-6 ng/mm2) was observed for most of the polymers. The surface coverage found for IgG bound specifically to the dextran-modified surface exceeded a protein monolayer.

Adsorption↗

Optical probes and transducers.

Biosensors are by definition a combination of a biological receptor compound and a physical or physicochemical transducer. Therefore, the transducing structure is a critical part of every biosensor. In the development of new and improved biosensing layers the importance of the transducing structure is not restricted to the substrate to which biological structures have to be coupled. A field of even greater importance is the use of transducers as probes providing information on the structure and function of biosensing layers, and their relation to a transducer surface. The aim of this paper is to give an overview on optical transducer principles and optical (surface) analytical techniques relevant as part of biosensing structures as well as probes in the development and optimisation of biosensing layers. Categories discussed are basic optical effects, materials involved, surface chemistry, the principal and technological limits of spatial resolution, and sensitivity. The intimate relation between the spatial resolution of a probe, the resulting size of interaction areas, and the feasibility of array structures is pointed out. Two interferometric methods are presented in principle, and their application to biosensing and some results are discussed in detail. The necessity to characterise receptor layers to get detailed information about the interaction process is pointed out. The close relationship between optimal characterisation of layers by selection of adequate probe technologies and improvement of probe performance, and the development of new biosensing layers is discussed. Finally, an outlook is given for future aspects of improved spatial resolution and multianalyte detection.

Biosensing Techniques↗

Characterization of biomembranes by spectral ellipsometry, surface plasmon resonance and interferometry with regard to biosensor application.

Phospholipid bilayers with transport proteins and antigen/antibody interfaces are considered to be suitable biosensor systems. The quality of such membranes or interfaces depends on the properties of the layers. Optical methods have proved to be an appropriate tool for characterizing those layers in situ and in a non-destructive manner. Two systems with potential for biosensor applications are characterized by some of these methods: phospholipid bilayer membranes spread from vesicle solution and protein-antigens both adsorbed on planar solid support. The results of spectral ellipsometry, surface plasmon resonance (SPR) and spectral interferometry are compared with respect to quality of characterization, expenditure of sample preparation and measurement, and time resolution. The phospholipid membranes adsorbed show a relatively low refractive index and a relatively high thickness. Bruggeman effective medium approximation is used to calculate the effective layer thickness. This result is compared to SPR measurements. A correlation between thickness and vesicle concentration may be detected. Further, the test protocol of an immunoassay is examined by spectral interferometry and SPR. Thicknesses determined are compared to results obtained by applying spectral ellipsometry. The data measured by ellipsometry are in agreement with the molecular dimensions of the immunoglobulins. Differences between details can be explained by physical considerations.

Biosensing Techniques↗

Dyeless optical detection of ammonia in the gaseous phase using a pH-responsive polymer--characterization of the sorption process.

pH-responsive polymers enable the dyeless optical detection of acidic or basic pollutants in air. The characterization of the sorption process and the optimization of the response time of the sensitive layers were high-lighted. The swelling of a pH-responsive polysiloxane induced by sorption of gaseous ammonia was investigated by measurement techniques such as spectroscopic ellipsometry (SE) and infrared spectroscopy (IR). Furthermore, the pH-responsive polymer was applied for the detection of gaseous ammonia using the LED-based reflectometric interference spectroscopy set-up (RIfS4lambda). A limit of detection of 0.30 mg/m3 ammonia and a response time (t90%) of 35 s could be verified. The application of pH-responsive polymers can be a powerful alternative to dye-based optical sensing, since photobleaching or leaching of the sensitive functional unit cannot occur applying this approach, and since the properties of the sensitive layer proved to be very promising.

Journal Article↗

Label-free detection of biomolecular interaction by optical sensors.

Since the first label-free optical biosensor was commercialized in 1990 a rising number of publications have demonstrated the benefits of direct biomolecular interaction analysis (BIA) for biology and biochemistry. This article first gives an overview of the historical development of different transducer principles used for the detection of BIA. Subsequently, the four major parts of a biosensor system: transducer, sample handling, surface/immobilization chemistry and test formats/data evaluation will be discussed, with a main focus on the test formats and data evaluation. The intention of this review is to present an introduction to the field and to point out the difficulties most frequently encountered.

Adsorption↗

Immunoanalytical techniques for pesticide monitoring based on fluorescence detection.

In the field of environmental analysis there is still great potential for development and application of immunoanalytical techniques (IT). Heterogeneous and homogeneous immunoassays (IA), flow-injection immunoanalysis (FIIA) and immunosensors (IS) with different detection principles have been developed. In this review we focus on fluorescence methods for pesticide monitoring published since 1992. These techniques offer a high degree of selectivity and, in principle, sensitivity. Restrictions on the limits of detection (LOD) due to background signals are minimized by development of solid-phase separation systems, new fluorescent probes, and new instrumentation.

Antibodies↗

New donor-acceptor pair for fluorescent immunoassays by energy transfer.

A novel Förster donor-acceptor dye pair for an immunoassay based on resonance energy transfer (RET) is characterized with respect to its photophysical properties. As donor and acceptor, we chose the long-wavelength excitable cyanine dyes Cy5 and Cy5.5, respectively. Due to the perfect spectral overlap, an exceptionally high R(0) value of 68.7 A is obtained in solution. For biochemical applications, antibodies (IgG) are labeled with Cy5, while a tracer for competitive binding is synthesized by labeling bovine serum albumin (BSA) with an analyte derivative and Cy5.5. Binding the dyes to proteins at a low dye/protein ratio increases the fluorescence lifetimes and quantum yields, leading to an enhanced R(0) value of 85.2 A. At higher dye/protein ratios, the formation of nonfluorescent dimeric species causes a decrease in the fluorescence lifetime and quantum yield due to RET from monomeric dyes to dimers within one protein molecule. The Förster distances could be calculated using the dimer absorption spectra to 83.9 and 83.6 A for Cy5 and Cy5.5, respectively. Upon binding of the Cy5-labeled IgG to the tracer, efficient quenching of Cy5 fluorescence is observed. Steady-state and time-resolved measurements reveal that approximately 50% of the quenching results in Förster-type RET, while the residual quenching effect is caused by static quenching processes. The applicability of this dye pair is demonstrated in a homogeneous competitive immunoassay for the pesticide simazine.

Binding, Competitive↗