Publications and source records attributed to G Gambarini.

At least 19 recordsLinked to original sources

Alterations of energy metabolism and glutathione levels of HL-60 cells induced by methacrylates present in composite resins.

OBJECTIVES: Methacrylic compounds such as 2-hydroxyethyl methacrylate (HEMA), triethylene glycol dimethacrylate (TEGDMA) and bisphenol A glycerolate (1 glycerol/phenol) dimethacrylate (Bis-GMA) are largely present in auto- or photopolymerizable composite resins. Since the polymerization reaction is never complete, these molecules are released into the oral cavity tissues and biological fluids where they could cause local adverse effects. The aim of this work was to verify the hypothesis that the biological effects of HEMA, TEGDMA and Bis-GMA - at a non-cytotoxic concentration - depend on the interaction with mitochondria and exert consequent alterations of energy metabolism, GSH levels and the related pathways in human promyelocytic cell line (HL-60). METHODS: The biological effects of methacrylic monomers were determined by analyzing the following parameters: GSH concentration, glucose-6-phosphate dehydrogenase (G6PDH) and glutathione reductase (GR) activity, oxygen and glucose consumption and lactate production along with cell differentiation and proliferation. RESULTS: All monomers induced both cellular differentiation and decrease in oxygen consumption. Cells treated with TEGDMA and Bis-GMA showed a significant enhancement of glucose consumption and lactate production. TEGDMA and HEMA induced GSH depletion stimulating G6PDH and GR activity. CONCLUSIONS: All the monomers under study affect the metabolism of HL-60 cells and show differentiating activity. Since alterations in cellular metabolism occurred at compound concentrations well below cytotoxic levels, the changes in energy metabolism and glutathione redox balance could be considered as potential mechanisms for inducing clinical and sub-clinical adverse effects and thus providing useful parameters when testing biocompatibility of dental materials.

Bisphenol A-Glycidyl Methacrylate↗

Dose imaging with gel-dosemeter layers: optical analysis and dedicated software.

In radiotherapy involving thermal and epithermal neutrons, the knowledge of dose distributions, with separation of the contribution of each secondary radiation component, is of utmost importance. Layers of Fricke-Xylenol-Orange-infused gel dosemeters give the possibility of achieving such requirements because, owing to the layer-geometry, enriching or depleting the gel matrix of suitable isotopes does not sensibly alter neutron transport. The dosimetry method has been critically re-examined with the aim of improving its suitability to boron neutron capture therapy (BNCT) requirements, as it applies to the protocol of measurement and analysis, the sensitivity of the method and the range of the linearity of the dosemeters. Software has been developed and studied to obtain automatically the images of the various dose components with the established separation procedure.

Algorithms↗

The influence of volume, type of irrigant and flushing method on removing artificially placed dentine debris from the apical root canal during passive ultrasonic irrigation.

AIM: To determine the influence of volume, irrigant and method of flushing on the removal of artificially-placed dentine debris from the apical part of root canals during passive ultrasonic irrigation. METHODOLOGY: Access cavities were prepared in 15 canine teeth and their root canals instrumented to size 20, 0.10 taper. Each root was split longitudinally, forming two halves. A groove was cut in the canal wall 2-6 mm from the apex in each half which was then filled with dentine debris prior to the roots being reassembled. All canals were ultrasonically irrigated, using a size 15, 0.02 taper smooth wire to a length of 21 mm that was placed in the canal to the apical foramen. In group 1 the canal was flushed with a continuous flow of 50 mL 2% sodium hypochlorite (NaOCl). In group 2 the continuous flow was not used but the canal was flushed with 12 mL 2% NaOCl, at a rate of 2 mL 30 s-1 using a syringe. Group 3 was treated in the same way as group 2 but the canal was flushed with 6 mL 2% NaOCl, at a rate of 2 mL min-1. Group 4 was treated in the same way as group 1 but water was used as the irrigant. Before and after irrigation, images of the grooves were captured and stored. The quantity of dentine debris in the groove was evaluated. The differences in debris scores between the experimental groups were analysed with the Kruskal-Wallis test and the Mann-Whitney U-test. The level of significance was set at P=0.05. RESULTS: The difference between all groups was statistically significant (K-W test P<0.001). Groups 1, 2 and 3 differed significantly from group 4 (P<0.001); there was no significant difference between groups 1, 2 and 3 (P=0.550). CONCLUSIONS: Syringe delivery of 2% NaOCl (6 and 12 mL) was as effective as a continuous flow of 2% NaOCl (50 mL). Water was not effective in removing dentine debris from grooves in the apical portion of root canals.

Cuspid↗

In vitro comparison of the cytotoxicity of two orthodontic composite resins.

AIM: Several studies have reported that dental resin-based materials release substances with biological activity: for this reason in this study we evaluated the in vitro cytopathic effects of a self-curing and a light-curing orthodontic composite resins by a cytotoxicity test. METHODS: The cytotoxic potential of specimens, prepared according to the manufacturer instructions, was evaluated using the thiazolyl blue tetrazolium bromide (MTT) assay on the mouse fibroblast cell line (3T3 Swiss) with 2 cells-material contact systems: the 24 h extracts method and the indirect toxicity method. RESULTS: The results obtained in this study elicit a close agreement between the 2 procedures; from the data obtained in the reported experimental conditions, it was possible to establish that the examined chemical-cured material is more cytotoxic than the light-cured one. CONCLUSIONS: From a clinical point of view, the photo-polymerizable resins are undoubtedly more useful in the daily practice, because of the larger precision of the bonding obtainable by the greater period available for setting the brackets before their lock. The results obtained in this study, even considering the limits of the in vitro tests, represent a further favourable feature of the light-curing composite resins. However, further investigations about the influence of polymerization methods of the materials on the biological effects are suggested to contribute to the determination of the best clinical operative conditions.

Acrylic Resins↗

Calcium release and pH-characteristics of calcium hydroxide plus points.

AIM: To evaluate calcium ion release and pH-characteristics of calcium hydroxide plus points (CHPP), conventional calcium hydroxide points (CHP, both Coltène/Whaledent, Langenau, Germany) and aqueous calcium hydroxide suspension (CHS) (Calxyl, OCO, Dirmstein, Germany). METHODOLOGY: Ten CHPP or CHP of size 50 were immersed into 5 mL isotonic sodium chloride solution. Conventional Ca(OH)2-free gutta-percha points served as negative control. Calcium release was measured up to 44 days by means of complexometric titration. Time dependent pH behaviour of all points in comparison with CHS was determined immersing 30 points of size 50 into 2.3 mL 0.9% wt NaCl-solution at time intervals of 0.5-72 h by a microelectrode measuring chain and a pH-meter. The surface morphologies of new and used gutta-percha points were evaluated qualitatively under a scanning electron microscope. Statistical evaluation was carried out using Kolmogorov-Smirnov-tests, Mann-Whitney-tests and multifactorial anova. RESULTS: For CHPP, a threefold greater calcium release was measured compared with CHP. Both types of points as well as CHS showed a maximum pH of approximately 12. Differences between groups were statistically significant for calcium release and pH (multifactorial anova; P < 0.001). Both types of points showed porous surfaces after usage, with a rougher surface for CHPP. CONCLUSIONS: CHPP and CHP increased the pH of isotonic sodium chloride >11 within 3 min. CHPP had a greater release of Ca2+ compared with CHP.

Analysis of Variance↗

In-phantom imaging of all dose components in boron neutron capture therapy by means of gel dosimeters.

The experimental method for in-phantom imaging and profiling the absorbed dose in neutron capture therapy has been improved. The method separates the contributions of the various secondary radiation components and is based on suitably designed gel dosimeters in the form of layers. The discrimination of the dose components is achieved by means of pixel-to-pixel manipulations of images obtained with gel dosimeters having different isotopic composition. Large dose images are obtainable with this method, because the layer geometry of dosimeters avoids sensible variation of neutron transport due to the isotopic composition of gel. Operation modalities aimed at attaining more reliable results have been studied. Some results, together with the results of punctual measurements performed with conventional dosimeters and with MC calculations, are here reported.

Boron Neutron Capture Therapy↗

Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use.

PURPOSE: The purpose of this study was to evaluate the cyclic fatigue of ProTaper nickel-titanium (NiTi) rotary instruments (Tulsa Dental, Tulsa, Okla) after multiple clinical uses. STUDY DESIGN: Two hundred twenty-five ProTaper instruments were divided into 3 groups: A = 75 used as controls, B = 75 used in 2 molars (6-8 canals), and C = 75 used in 4 molars (12-16 canals). The number of rotations to breakage and the fractured tip length were recorded for each file and the mean was calculated by ANOVA. RESULTS: No S1-2 or F1-2-3 instrument separated during intracanal use, even if they were reused for a number of cases (x 4 molar cases). CONCLUSION: It is clear that prolonged reuse of NiTi rotary instruments strongly affects instruments' fatigue, but our data suggest the hypothesis that other factors (primarily errors and misuse) may be more accountable for intracanal instrument separation. Further studies could assess the cyclic fatigue of each instrument at different levels of the shaft by altering the radius of curvature.

Analysis of Variance↗

Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT).

A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF2:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH3CH(NH2)COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT.

Alanine↗

Study of a method based on TLD detectors for in-phantom dosimetry in BNCT.

A method has been developed, based on thermoluminescent dosemeters (TLD), aimed at measuring the absorbed dose in tissue-equivalent phantoms exposed to thermal or epithermal neutrons, separating the contributions of various secondary radiation generated by neutrons. The proposed method takes advantage of the very low sensitivity of CaF2:Tm (TLD-300) to low energy neutrons and to the different responses to thermal neutrons of LiF:Mg,Ti dosemeters with different 6Li percentage (TLD-100, TLD-700, TLD-600). The comparison of the results with those obtained by means of gel dosemeters and activation foils has confirmed the reliability of the method. The experimental modalities allowing reliable results have been studied. The glow curves of TLD-300 after gamma or neutron irradiation have been compared; moreover, both internal irradiation effect and energy dependence have been investigated. For TLD-600, TLD-100 and TLD-700, the suitable fluence limits have been determined in order to avoid radiation damage and loss of linearity.

Body Burden↗

Characterisation of the TAPIRO BNCT epithermal facility.

A collimated epithermal beam for boron neutron capture therapy (BNCT) research has been designed and built at the TAPIRO fast research reactor. A complete experimental characterisation of the radiation field in the irradiation chamber has been performed, to verify agreement with IAEA requirements. Slow neutron fluxes have been measured by means of an activation technique and with thermoluminescent detectors (TLDs). The fast neutron dose has been determined with gel dosemeters, while the fast neutron spectrum has been acquired by means of a neutron spectrometer based on superheated drop detectors. The gamma-dose has been measured with gel dosemeters and TLDs. For an independent verification of the experimental results, fluxes, doses and neutron spectra have been calculated with Monte Carlo simulations using the codes MCNP4B and MCNPX_2.1.5 with the direct statistical approach (DSA). The results obtained confirm that the epithermal beams achievable at TAPIRO are of suitable quality for BNCT purposes.

Algorithms↗

Characterisation of the TAPIRO BNCT thermal facility.

Dosimetry and spectrometry measurements have been carried out in the thermal column of the research fast reactor RSV-TAPIRO (ENEA-Casaccia, Rome) in order to investigate its suitability for irradiation of cells or mice, with a view to research in the interests of boron neutron capture therapy (BNCT). The thermal column consists of a graphite moderator (40 cm thick) containing a lead shield (13 cm thick) in order to shield reactor background. The irradiation volume, inside this structure, has cubic shape (18 x 18 x 18 cm3). Besides measurements of fluence and dose rates in air or in phantom performed with thermoluminescence dosemeters (TLDs) and using the activation technique, dose and fluence profiles have been generated using a method based on gel dosemeters analysed with optical imaging. To check the consistency of the results, spectrometry measurements in the same irradiation volume have been performed by means of bubble detectors.

Animals↗

Cytotoxicity of a new endodontic filling material.

In vitro cell cultures have been widely used as a means of evaluating cytotoxicity of root canal filling materials. Following ANSI/ADA spec. no. 41, the aim of the present study was to investigate the biological compatibility of a new sealer (FibreFill) and compare it with some commercially available endodontic sealers (Bioseal and Acroseal). Mouse 3T3 fibroblasts were seeded and cultured and subsequently extracts of the cements were added. After 24 hours incubation, the cellular vitality of fibroblasts was evaluated by the neutral red uptake test (NRU), which measures the membrane permeability. Data were collected and statistically analysed. Results showed that all tested materials exhibited mild cytotoxic effects, which are compatible with normal clinical use, and no statistically significant difference was noted between FibreFill and the other tested materials. Therefore, selection amongst these sealers should be based on other factors.

3T3 Cells↗

[Mechanical properties of nickel-titanium files following multiple heat sterilizations].

AIM: The effect of cycles of sterilization procedures on nickel-titanium (NiTi) endodontic instruments is a serious concern for practitioners. There is no agreement in the literature whether these procedures could adversely affect the mechanical properties of endodontic files, and, consequently, increase the risk of intracanal failure. The purpose of this study was to evaluate the mechanichal resistance of Hero (MicroMega, Besancon, France) instruments, before and after sterilization procedures. METHODS: Thirty 02, 04, 06 tapered Hero size 30 new instruments were chosen and divided into 3 groups. Group A (control) were tested according to ANSI/ADA Spec.no 28 for torsional resistance, angle of torque and angle at breakage (45 inverted exclamation mark ). Group B files were first sterilized with chemiclave for 10 cycles of 20 minutes at 124 inverted exclamation mark C and then tested as described above. Group C files were first sterilized with glass beads for 10 cycles of 20 sec. at 250 inverted exclamation mark C and then tested as described above. Data were collected and statistically analyzed (t-paired test). Differences among the 3 groups were statistically not significant for both tests. RESULTS: All data were well within Spec.no 28 standard values. CONCLUSION: From the results of the present study, we may conclude that repeated sterilization procedures do not adversely affect the mechanichal resistance of Hero files.

Dental Implantation, Endosseous, Endodontic↗

A scanning electron microscopic study of debris and smear layer remaining following use of GT rotary instruments.

AIM: The aim of the present study was to assess debris and smear layer remaining following canal preparation with GT rotary instruments. METHODOLOGY: Sixteen freshly extracted single-rooted premolar teeth were instrumented with GT rotary instruments using a crown-down preparation technique. All specimens were flushed with 2 mL of 5% NaOCl between each rotary instrument. At the end of instrumentation the following final irrigation sequence was repeated two times: 2 mL of EDTA + Cetrimide for 1 min (Largal Ultra, Septodont, France) and 2 mL of 5% NaOCl for 5 min. A final flush with saline solution was made to halt any chemical activity. Two other uninstrumented teeth that were not irrigated served as controls. All teeth were split longitudinally and prepared for SEM evaluation. The presence of debris and smear layer was evaluated from photomicrographs at x200 and x1000 magnification taken in the apical, middle and coronal thirds of the canals. Blind evaluation was performed by two trained observers and scores were compiled separately. A five category scoring system for debris and smear layer was used. Values obtained were tabulated and statistical analysis was carried out using a parametric chi-squared test. RESULTS: Statistical analysis showed that there was no significant difference between the three regions of the root canals (P > 0.05) for debris. Comparison of the removal of the smear layer between the three regions showed that there was a statistically significant difference between all parts, especially between the coronal and apical thirds (P < 0.001). Overall, the coronal sections were cleaner than the middle and apical sections. The uninstrumented canals showed walls completely covered with tissue, confirming that specimen preparation alone did not remove tissue. CONCLUSIONS: Under the conditions of the present study GT rotary instruments removed debris effectively, but left root canal walls covered with smear layer, particularly in the apical third.

Bicuspid↗

Fricke gel dosimetry in boron neutron capture therapy.

Gel dosimetry allows three-dimensional (3D) measurement of absorbed dose in tissue-equivalent dosemeter phantoms. Gel phantoms are imaged using optical techniques. In neutron capture therapy (NCT), properly designed gel dosemeters can give 3D dose distributions, due to the various components of the secondary radiation, in phantoms exposed in the thermal or epithermal column of a nuclear reactor. In addition to the therapeutic dose arising from the reaction 10B(n,alpha)7Li, the other dose components are also obtainable, i.e. the gamma dose (due to reactor background and to the reaction 1H(n,gamma)2H of thermal neutrons with hydrogen, the dose due to protons emitted in the reaction 14N(n,p)14C of thermal neutrons with nitrogen and the dose due to recoil protons resulting from elastic scattering of epithermal neutrons.

Boron Neutron Capture Therapy↗

Cyclic fatigue of ProFile rotary instruments after prolonged clinical use.

AIM: The purpose of the present study was to evaluate resistance to cyclic fatigue of new and used ProFile Ni-Ti rotary instruments. METHODOLOGY: Used instruments were operated in 10 clinical cases using passive instrumentation and a crown-down preparation technique. Cyclic fatigue testing of new and used engine-driven instruments was then performed with a specific device which allowed the instruments to rotate freely inside a stainless steel artificial canal, whilst maintaining conditions close to the clinical situation. Instruments were rotated until fracture occurred and time to fracture was visually recorded with a chronometer. RESULTS: A significant reduction of rotation time to breakage (life span) was noted between new and used instruments. In all sizes new instruments were significantly more resistant than used ones (two-sample t-test, P < 0.01). No instrument underwent intracanal failure during clinical use. CONCLUSIONS: Prolonged clinical use of Ni-Ti engine-driven instruments significantly reduced their cyclic fatigue resistance. Nevertheless, each rotary instrument was successfully operated in up to 10 clinical cases without any intracanal failure.

Dental High-Speed Technique↗

Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors.

This study investigated the cyclic fatigue resistance of used nickel-titanium rotary instruments, clinically operated by a traditional high-torque motor and a new low-torque electric motor. Fifty instruments (ProFile, Maillefer, Baillagues, Switzerland) for each of the following sizes were used: .06-25, .06-20, and .04-25. They were divided into three groups: A = 10 new instruments (control), B = 20 used instruments operated by a high-torque motor, and C = 20 used instruments operated by a low-torque motor. Each instrument was used in 10 clinical cases (at least six molars). Cyclic fatigue testing of new and used instruments was performed with a device that allowed the instruments to rotate freely inside a stainless-steel artificial canal at 350 rpm. Data were recorded and statistically analyzed. Mean (and SD) numbers of rotation-to-breakage cycles for .06-25, .06-20, and .04-25 instruments were, respectively: group A 463 (85), 535 (101), and 613 (105); group B 229 (64), 343 (92), and 233 (84); and group C 352 (77), 454 (89), and 466 (86). Results showed that group A instruments exhibited significantly higher values of rotation-to-breakage cycles (two-sample t test, p < 0.01), when compared with groups B and C, respectively. Statistically higher resistance to cyclic fatigue was noted for group C in all sizes compared with group B (two-sample t test, p < 0.01), showing that the use of endodontic motor with lower torque values reduced cyclic fatigue of nickel-titanium rotary instruments.

Dental High-Speed Technique↗

Advantages and disadvantages of new torque-controlled endodontic motors and low-torque NiTi rotary instrumentation.

The main problem with the NiTi rotary instrumentation technique is instrument failure. During shaping procedures, rotary instruments might lock and/or screw into canals and, consequently, be subjected to high levels of stress. This may frequently lead to instrument separation or deformation. If a high-torque motor is used, the applied forces are usually very high and the instrument-fracture limit is often exceeded, thus increasing the risk of intracanal failure. A possible solution of this problem is to use a low-torque endodontic motor, which operates below the maximum permissible torque limit of each and every rotary instrument. During clinical instrumentation of root canals, if a torque-controlled motor is loaded right up to the instrument-specific torque, the motor stops momentarily and/or starts rotating counter-clockwise (auto-reverse function) to disengage the locked instrument. These safety mechanisms were developed to reduce the risk of instrument fracture. The author fully discusses the rationale for selecting lower torque values in everyday endodontic practice, and provides clinicians with useful information on the advantages and disadvantages of new endodontic motors with torque control.

Dental Instruments↗