Search PubMed⌕ Search

Biomedical subjects

G G Weinmann

Publications and source records attributed to G G Weinmann.

24 records · Page 2Linked to original sources

Effect of high-frequency ventilation on histamine-induced lung injury in dogs.

We compared the effects of high-frequency oscillation (HFO) and conventional mechanical ventilation (CMV) on dynamic lung compliance (Cdyn), venous admixture (Qsp/Qt), cardiac output, and total lung resistance (RL) in seven mongrel dogs with histamine-induced lung injury. Baseline measurements during CMV were followed by iv infusion of histamine at 100 micrograms/min. Cdyn, Qsp/Qt, cardiac output, and RL were measured in triplicate during CMV and then during HFO. Subsequently, at least one complete set of measurements was recorded again on CMV. During HFO, animals were ventilated at 15 Hz with a tidal volume of 70 to 80 ml. CMV was delivered at 15 to 18 breath/min with a tidal volume of 15 ml/kg. Histamine infusion produced a marked fall in Cdyn, a variable rise in RL, an inconsistent but usually progressive rise in Qsp/Qt, and hypotension. A period of ventilation with HFO made no difference in the Cdyn, Qsp/Qt, or cardiac output changes produced by histamine infusion.

Animals↗

Tonic beta-sympathetic activity in the lung periphery in anesthetized dogs.

The present study was undertaken to determine whether beta-adrenoceptors could be physiologically detected in the lung periphery and whether they were under tonic stimulation in the resting state in anesthetized dogs. A fiberoptic bronchoscope was wedged in a sublobar segment of lung in anesthetized male mongrel dogs for measurement of resistance through the collateral system (Rcs). beta-Agents were delivered locally as aerosols through the bronchoscope, and the response was evaluated by changes in Rcs. Distilled water alone produced a mean increase of 8.5 +/- 2.43% (SE) in Rcs at 2 min in six dogs, whereas dl-isoproterenol produced a mean decrease of 8.9 +/- 2.10% (P less than 0.03), thus demonstrating the presence of submaximally stimulated beta-receptors. To test whether the beta-receptors were under tonic stimulation, we compared the effect of aerosolized d- and dl-propranolol in 5 dogs. d-Propranolol that lacks significant beta-blocking activity and dl-propranolol both produced large transient increases in Rcs. However, with d-propranolol, Rcs had returned to base line at 15 min, whereas with dl-propranolol Rcs remained elevated at a mean of 20% above base line for greater than 2 h (P less than 0.01). Local timolol aerosol also produced a sustained increase in Rcs. After pretreatment with reserpine or after bilateral adrenalectomy, both d- and dl-propranolol still produced large transient increases in Rcs, but dl-propranolol no longer produced a sustained increase. Neither isoproterenol nor atropine affected Rcs in the presence of dl-propranolol, nor did pretreatment with atropine affect the response of Rcs to dl-propranolol.(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenalectomy↗

Lung compliance changes on high-frequency ventilation in normal dogs.

To test the hypothesis that high-frequency ventilation (HFV) promotes lung stability we compared the temporal course of dynamic lung compliance changes after two inflations on HFV with those occurring on conventional mechanical ventilation (CMV) at two different lung volumes, specifically with and without 5 cmH2O positive end-expiratory pressure (PEEP). In our first set of experiments we ventilated six anesthetized paralyzed dogs first with CMV, then with HFV, then again with CMV using tidal volumes of 15 ml/kg at rates of 16-18 times/min for CMV and less than 90 ml and a rate of 15 Hz for HFV. In our second set of experiments we ventilated six dogs for 4 h, the 1st h with CMV at 0 cmH2O end-expiratory pressure, the 2nd h with CMV with 5 cmH2O PEEP, the 3rd h with HFV at the same mean pleural pressure, and the 4th h again with CMV with 5 cmH2O PEEP. We found the decreases in dynamic compliance with time following hyperinflations were similar on HFV and CMV (P greater than 0.5) at both lung volumes. With the lower lung volume the initial dynamic compliance following hyperinflation also tended to fall progressively from one hour to the next despite the inflations. However, with PEEP the initial dynamic compliance over successive hours tended to rise from one hour to the next. We found that changes in dynamic compliance were not necessarily reflected in the venous admixture or alveolar to arterial O2 partial pressure gradients. We thus conclude that lung stability in normal dogs is not improved during HFV, and blood gases cannot be used to predict compliance changes.

Animals↗

Physiological dead space during high-frequency ventilation in dogs.

Tidal volumes used in high-frequency ventilation (HFV) may be smaller than anatomic dead space, but since gas exchange does take place, physiological dead space (VD) must be smaller than tidal volume (VT). We quantified changes in VD in three dogs at constant alveolar ventilation using the Bohr equation as VT was varied from 3 to 15 ml/kg and frequency (f) from 0.2 to 8 Hz, ranges that include normal as well as HFV. We found that VD was relatively constant at tidal volumes associated with normal ventilation (7-15 ml/kg) but fell sharply as VT was reduced further to tidal volumes associated with HFV (less than 7 ml/kg). The frequency required to maintain constant alveolar ventilation increased slowly as tidal volume was decreased from 15 to 7 ml/kg but rose sharply with attendant rapid increases in minute ventilation as tidal volumes were decreased to less than 7 ml/kg. At tidal volumes less than 7 ml/kg, the data deviated substantially from the conventional alveolar ventilation equation [f(VT - VD) = constant] but fit well a model derived previously for HFV. This model predicts that gas exchange with volumes smaller than dead space should vary approximately as the product of f and VT2.

Animals↗

Mean airway pressure and alveolar pressure during high-frequency ventilation.

Studies and applications of high-frequency ventilation (HFV) are often performed under conditions of controlled mean airway pressure (Paw). In the present study we tested the assumption that controlling Paw adequately controls lung volume during HFV by investigating the relationship between a reliably measured Paw and the mean alveolar pressure (Palv) of the lungs during HFV of healthy dogs. We minimized the errors of Paw measurement due to the Bernoulli effect and various technical factors by appropriate choice of transducers, amplifiers, and measurement site. Palv was estimated by clamping the ventilator tube during oscillation and measuring the equilibration pressure of the lung and airways. Paw and Palv were determined as functions of frequency (8-25 Hz), tidal volume (60-90 ml), Paw (-5 to 12 cmH2O), and position of the animal (supine vs. lateral). We found that Paw could significantly underestimate Palv and that the degree of underestimation increased at higher frequencies, larger tidal volumes, and lower Paw. Shifting the animal from the supine to the lateral position greatly accentuated this effect. The elevation of Palv above Paw was seen to be a function of mean flow and largely independent of the frequency-tidal volume combination which produced the flow. A possible explanation of this pressure difference is that it results from differences in inspiratory and expiratory airway impedances, which in turn depend on airway geometry, compliance, lung volume, and expiratory flow limitation.

Airway Resistance↗

A method for assessing small airways independent of inspiratory capacity.

Reduced forced vital capacity may confound assessment of small-airway function. In 17 healthy and 16 asthmatic volunteers, we validated a method for measuring mean expiratory flow during the middle half of the forced vital capacity, mean expiratory flow during the third quarter of the forced vital capacity, instantaneous forced expiratory flow at 50% of forced vital capacity , and instantaneous expiratory flow at 75% of forced vital capacity. These measurements were conducted at the same absolute lung volume (isovolume) when forced vital capacity was reduced voluntarily to 100%, 85%, and 75% of maximum, and the variances, expressed as the coefficients of variations, were compared. Absolute lung volumes above residual volume were determined with two reference spirograms: 100% and 75% forced vital capacity. In normals, means of flow rates at the same absolute lung volume did not differ with the three forced vital capacities, regardless of whether the 100% or 75% forced vital capacity served as the reference spirogram. Reduced forced vital capacity among asthmatics was associated with modest increases in isovolume flow rates, an effect that may underestimate airway narrowing. Intrasubject variability was least among volume-averaged flow rates (e.g., mean expiratory flow during the middle half of the forced vital capacity). Volume-adjusted flow rates can be used to assess small-airways narrowing when forced vital capacity is reduced, and volume-averaged rates provide the least variability.

Adult↗