Search PubMed⌕ Search

Biomedical subjects

G G Power

Publications and source records attributed to G G Power.

At least 109 records · Page 6Linked to original sources

Determination of distribution of diffusing capacity in relation to blood flow in the human lung.

A method for appraising the distribution of diffusing capacity of the lungs (D(L)) in relationship to pulmonary capillary blood flow ([unk]Q(C)) in normal human subjects was derived from measurements of oxygen diffusing capacity (D(LO2)) and carbon monoxide diffusing capacity (D(LCO)) performed during breath holding. This method utilizes the fact that the observed D(LO2) is considerably reduced in value if uneven distribution of D(L) with respect to [unk]Q(C) (uneven D(L)/[unk]Q(C)) is present. In contrast, D(LCO) is barely affected by uneven D(L)/[unk]Q(C), and from its measured value one can calculate the value D(LO2) would have if no uneven D(L)/[unk]Q(C) were present (true D(LO2)). Once observed D(LO2) and true D(LO2) are known, the degree of uneven D(L)/[unk]Q(C) in the lung can be calculated. In five normal, resting, sitting subjects average values for true D(LO2) were 57 ml per (minute x mm Hg), and the directly measured D(LO2) was 33 ml per (minute x mm Hg). These values could be explained if one-half of total [unk]Q(C) were distributed to approximately 15% of total D(L). These measurements did not permit the determination of the alveolar to end capillary O(2) gradient, but calculations demonstrate that an important factor in determining its size may be the pattern of uneven D(L)/[unk]Q(C) present in the lungs. Estimations of the alveolar-end capillary O(2) gradient from measurements of D(LCO) or D(LO2) that do not take into account uneven D(L)/[unk]Q(C) may underestimate its size.

Adult↗

Respiratory function of the placenta as determined with carbon monoxide in sheep and dogs.

A technique is described for studying the respiratory function of the placenta using carbon monoxide, a gas whose exchange across the placenta between the maternal and fetal circulations is limited by diffusion rather than blood flow. During the steady state before the introduction of CO, the normal concentration of carboxyhemoglobin in the ewe, [COHb](M), is approximately 0.90%, and that in the fetus is 2.9%, the ratio [COHb](F)/[COHb](M) being 3.2. In dogs the corresponding values are 1.9%, 4.8%, and 2.4%. After the introduction of CO into the mother animal, CO diffused across the placenta slowly with an equilibration half-time of approximately 2 hours. The average carbon monoxide diffusing capacity (D(Pco)) of the placenta during maternal to fetal exchange was 0.54 ml per (minute x mm Hg x kg fetal weight) (SD +/- 0.13) in sheep and 0.57 ml per (minute x mm Hg x kg) (SD +/- 0.18) in dogs. The fetal to maternal placental diffusing capacity in two sheep was 0.54 ml per (minute x mm Hg x kg). Calculations considering the relative rates of reaction of O(2) and CO with red cell hemoglobin and the relative rates of diffusion of the two gases suggest that the true D(Po2) should be about 1.2 to 2 times greater than the D(Pco) or 0.65 to 1.1 per (minute x mm Hg x kg). This is about 5 times greater than the reported value of D(Po2) calculated from measurements of P(O2) in the mixed uterine and umbilical venous blood. With a diffusing capacity of this magnitude the maternal and fetal placental end capillary P(O2) would approach equilibrium, becoming too small to measure, and the calculation of D(Po2) would be unreliable. We suggest that the apparent end capillary P(o2) gradients of 15 to 20 mm Hg, obtained from sampling uterine and umbilical venous blood, result from a combination of uneven distribution of maternal and fetal placental blood flow and from placental oxygen consumption.

Animals↗

Uneven distribution of maternal and fetal placental blood flow, as demonstrated using macroaggregates, and its response to hypoxia.

A technique is described for studying the distribution of blood flow to the maternal and fetal placental vessels in sheep and dogs with radioactive labeled macroaggregates of albumin. When the maternal animal breathed room air the distribution of maternal placental blood flow was uneven among the cotyledons as well as within a given cotyledon. Fetal blood flow was also distributed nonuniformly among and within the cotyledons. The relation of maternal to fetal placental blood flow was also markedly uneven (coefficient of correlation, tau = 0.066). After the animal was made hypoxic by breathing 10-12% O(2) the distribution of maternal, fetal, and maternal/fetal placental flows became more uniform. The coefficient of correlation of maternal to fetal flow was high (tau = 0.53, P < 0.01). While the maternal animal breathed room air, after ligation of a major branch of the umbilical artery the distribution of maternal, fetal, and maternal/fetal flows in the remaining two-thirds to three-fourths of the placenta became more uniform. The correlation coefficient for maternal to fetal flow was high (tau = 0.35, P < 0.01).It appears that under normal circumstances with uneven distribution of blood flows there is a considerable portion of the placenta that does not receive blood flow in optimum quantities to promote efficient O(2) exchange. Failure to consider the influence of nonuniform maternal flow/fetal flow will result in overestimation of mean maternal-fetal oxygen tension gradients, and thus underestimation of the placental diffusing capacity for oxygen. In response to maternal hypoxia or compromise of the fetal placental circulation the distribution of maternal, fetal, and maternal/fetal flows becomes more uniform, thereby increasing the efficiency of placental O(2) exchange.

Animals↗