Subclavian steal syndrome: an update.

The clinical findings in this series of 22 cases of subclavian steal syndrome showed a predominance of men (13:9), a mean age of 51 years, and a predominance of left subclavian artery obstruction. There was a blood pressure differential of more than 20 mm Hg and diminished pulses ipsilaterally in most. Main indications for surgical repair were transient neurologic symptoms. Twenty-one of our patients had surgical repair of the subclavian steal syndrome; six had concomitant carotid artery surgery. The most common surgical procedure performed consisted of a carotid subclavian bypass graft. One patient had only carotid revascularization; 19 patients have had good long-term results. One patient, with tetralogy, died and three had complications. The asymptomatic or mildly symptomatic patient may be given a trial of medical treatment. Symptomatic patients can have extrathoracic bypass with a very low risk. Surgery is indicated if significant associated carotid lesions are present.

Adult↗

Runaway pump head: new cause of gas embolism during cardiopulmonary bypass.

Massive gas embolism was narrowly avoided during a recent case of cardiopulmonary bypass for aortic valve replacement. Cause of the mishap was an arterial pump head that had rapidly accelerated spontaneously, emptying the oxygenator of blood within seconds. No gas entered the patient's vascular system, but a period of circulatory arrest was required in order to purge the extracorporeal circuit of gas and to re-establish blood flow. Only an instantaneous response by the perfusionist prevented massive gas embolism.

Cardiopulmonary Bypass↗

Similarity of clinical and laboratory results obtained with microporous teflon membrane oxygenator and bubble-film hybrid oxygenator.

For 80 elective clinical cardiopulmonary bypasses we alternately used either a commercial microporous Teflon membrane oxygenator or a commercial hybrid bubble-film oxygenator. Setup time was a little longer with the membrane unit (20 minutes), but priming volume (2,250 ml) was the same. No problems were encountered with the hybrid oxygenator. However, despite our monitoring of additional variables, including shim and inlet pressure and recirculation flow, gas exchange abnormalities were encountered in 5 patients on whom the membrane oxygenator was used; in 4 of these cases the abnormalities were encountered prior to our recognition of the potential for occasional internal shunting with this device. There were no hospital deaths. When the two groups, matched except for oxygenator selection, were compared, there were no significant differences clinically or hematologically. For cardiopulmonary bypass of 2 hours or less, both oxygenators studied are definite improvements over previous silicone membrane and high-gas-flow bubble oxygenators. However, lower cost and reduced complexity favor the hybrid oxygenator.

Blood Glucose↗

Current status of pacemaker power sources.

After years during which pacers of very similar design and capabilities were provided by a small number of manufactures, many different lithium, halogen, rechargeable, and nuclear power sources are now available. The variety of chemistries, methods of construction, and sealing techniques used in the batteries of the different manufacturers is almost unlimited. This has made it necessary for physicians who implant and follow pacer to acquire a general knowledge of the field if they are to make an informed choice of pacemaker power source for implantation and if they are to manage recalls with a minimum of patient and physician trauma. More experience is required before it can be definitely determined which of the new pacer power sources will prove superior, but when coupled with well-designed, hermetically sealed pulse generators, all are capable of providing continuous pacing for at least 5 years and the 10-year pacemaker is now a probability.

Animals↗

Symptomatic deep venous thrombosis of the arm associated with permanent transvenous pacing electrodes.

From October 1970 to May 1977, a total of 212 pacemakers were implanted at the Milton S. Hershey Medical Center of Pennsylvania State University, Hershey. During this period, we encountered five patients with symptomatic thrombosis of the subclavian vein, a rate for this complication of approximately 2 percent. Although this complication was reported only rarely prior to 1976, we believe that symptomatic subclavian thrombosis after insertion of a transvenous pacemaker electrode occurs more frequently than previously suspected. The etiology, pathogenesis, and treatment of this interesting condition are discussed.

Aged↗

The changing status of ejection fraction as a predictor of early mortality following surgery for acquired heart disease.

Several reports in the literature and our experience prior to 1974 support the thesis that operative risk in patients with acquired heart disease and poor ventricular function (as assessed by a biplane ejection fraction [EF] less than or equal to 0.40) was very significantly increased over the risk in patients with normal ventricular function. These results led to disagreement in the literature regarding the advisability of surgery in patients with poor ventricular function. Various EFs from less than 0.31 to less than 0.50 were suggested as contradicting elective surgery, while more aggressive groups recommended surgery in all patients with angina. Precise comparison of the results reported by different groups was not always possible because of the common reliance on single-plane right anterior oblique ventriculograms, which tend to underestimate EF and overestimate operative risk. Using biplane ventribulograms for accurate estimation of EF, we have demonstrated a significant reduction in 30-day operative risk to a clinically acceptable 3 percent (1/32) for single valve replacement and aortocoronary surgery patients with poor ventricular function (EF less than or equal to 0.40) during 1974. Considering the high risk of medically treated patients with reduced ventricular function, these results support further evaluation of surgical palliation for patients with valvular or coronary heart disease and reduced ventricular function.

Cardiac Volume↗

Effect of perfusate temperature on myocardial protection from ischemia.

During reperfusion, functional and metabolic recovery of the isolated working rat heart from one hour of ischemia was best in hearts selectively cooled at the onset of the ischemic interval by perfusion with 5 to 10 ml. of 10 degrees C. or 15 degrees C. Krebs-Henseleit buffer. Hearts similarly perfused at 4 degrees C., 20 degrees C. recovered significantly less well or not at all. Immediately after the hour of ischemia and prior to reperfusion, the absolute levels of glycogen and high-energy phosphates were best in the hearts perfused at 4 degrees C. However, metabolic function was best preserved in those perfused at 10 degrees C. and 15 degrees C., as evidenced by rapid recovery of high-energy phosphates and glycogen to control levels compared to metabolic deterioration in the 4 degrees C. group.