Search PubMed⌕ Search

Biomedical subjects

G E Morfill

Publications and source records attributed to G E Morfill.

43 records · Page 3Linked to original sources

Scaling-index method as an image processing tool in scanning-probe microscopy.

The scaling-index method (SIM) is a novel tool for image processing in scanning-probe microscopy. Originating from the theory of complex systems, the SIM can be used in order to extract structural information from arbitrary data sets. This method can readily be applied to the analysis of digital atomic-force microscopy (AFM) images. Especially for biomedical diagnostics, where genetic material is investigated by various microscopic methods, a reliable image segmentation based on the SIM algorithm is helpful. As a first application, AFM-images of GTG-banded human metaphase chromosomes (with G bands obtained by Trypsin using Giemsa) are compared with micrographs from conventional light microscopy by means of a scaling-index analysis. While the grey-level distributions of the optical and the AFM-images are largely different from each other, the scaling-index images are remarkably similar. Using this method, a fingerprint of an image can be produced which helps in the classification and interpretation of the measured data.

Algorithms↗

Three-dimensional strongly coupled plasma crystal under gravity conditions.

Experiments were carried out to investigate a three-dimensional (3D) plasma crystal. A method of determining the positions of each individual microparticle has been developed. A crystal volume of about 2x10(4) particles in 19 horizontal planes was analyzed. Direct imaging and the 3D pair correlation function show that "domains" of fcc and hcp lattices coexist in the crystal. Other structures, in particular, the theoretically predicted bcc lattice, were not observed.

Journal Article↗

Theory of dust voids in plasmas.

Dusty plasmas in a gas discharge often feature a stable void, i.e., a dust-free region inside the dust cloud. This occurs under conditions relevant to both plasma processing discharges and plasma crystal experiments. The void results from a balance of the electrostatic and ion drag forces on a dust particle. The ion drag force is driven by a flow of ions outward from an ionization source and toward the surrounding dust cloud, which has a negative space charge. In equilibrium the force balance for dust particles requires that the boundary with the dust cloud be sharp, provided that the particles are cold and monodispersive. Numerical solutions of the one-dimensional nonlinear fluid equations are carried out including dust charging and dust-neutral collisions, but not ion-neutral collisions. The regions of parameter space that allow stable void equilibria are identified. There is a minimum ionization rate that can sustain a void. Spatial profiles of plasma parameters in the void are reported. In the absence of ion-neutral collisions, the ion flow enters the dust cloud's edge at Mach number M=1. Phase diagrams for expanding or contracting voids reveal a stationary point corresponding to a single stable equilibrium void size, provided the ionization rate is constant. Large voids contract and small voids expand until they attain this stationary void size. On the other hand, if the ionization rate is not constant, the void size can oscillate. Results are compared to recent laboratory and microgravity experiments.

Journal Article↗

Variability of ventricular premature complexes and mortality risk.

A method using a parameter from the field of nonlinear dynamics to quantify the variability of ventricular premature complexes (VPCs) is presented. One hundred patients with coronary artery disease and > or = 10 VPCs/hour were included in the study. The RR intervals were plotted in a three-dimensional artificial phase space, and the structures in phase space were quantified by the local scaling indices, alpha. In the frequency distribution histogram, n(alpha), for each patient, the maximum of the ventricular ectopies alpha VPC, adjusted to the VPC frequency, was assessed; alpha VPC was used as the risk indicator. Endpoints were total mortality and sudden cardiac death. During follow-up (mean 3.1 years), 28 out of 100 patients died, 16 suddenly; alpha VPC had a significant prognostic impact and was independent from other risk indicators, such as left ventricular ejection fraction (LVEF). Patients who died during follow-up were characterized by a high alpha VPC. The optimal discrimination of high risk patients and low risk patients occurred at alpha VPC = 3.0. After 4 years, the survival rate of patients with a alpha VPC > 3.0 was 59%, in contrast to 97% in patients with alpha VPC < or = 0.3. As to the sudden death mortality, the survival rates were 74% and 97%, respectively. The difference between the groups were significant for both endpoints. Patients with an increased VPC variability (i.e., alpha VPC > 3.0) were at enhanced risk of sudden death and total mortality risk; alpha VPC was independent from other risk indicators such as the LVEF or heart rate variability parameters.

Adolescent↗

[Complexity analysis and intrapartum CTG].

OBJECTIVES: This study was performed to prove, if the use of methods, that are based on procedures for analysis of chaotic systems ("complexity analysis"), can give information on the fetal condition during birth and predict both the course of delivery and fetal outcome. PATIENTS AND METHODS: Fetal ECG was derived in 37 pregnancies (36-42 weeks of gestation) during birth for two to seven hours. In 12 cases delivery was uncomplicated, in 24 cases FHR tracings had been pathological. RESULTS: Complexity analysis of fetal ECG signals showed within short observation intervals criteria that may be a hint for imminent fetal distress and acidosis. CONCLUSIONS: Application of complexity analysis in the future may give additional information for evaluation of intrapartum CTG in cases of suspicious FHR patterns.

Adult↗