Search PubMed⌕ Search

Biomedical subjects

G E Loeb

Publications and source records attributed to G E Loeb.

At least 37 records · Page 2Linked to original sources

The effect of sarcomere length on triad location in intact feline caudofeomoralis muscle fibres.

The location of triads within a mammalian skeletal muscle sarcomere has traditionally been defined as 'at the A-I junction'. We attempted to verify this statement by examining systematically the location of triads within the sarcomere over the physiological range of sarcomere lengths. This study was conducted using intact feline muscle fibres from caudofemoralis and exclusively fast-twitch muscle from the hindlimb. Our results intact fibres indicate that the distance between the Z-band and triad (ZT) is relatively constant over the range of sarcomere lengths (SLs)examined in this study (1.8-3.4 micron). The slope between ZT and SL was measured to be 0.06 +/- 0.01 (r= 0.36, p < 0.001) while the slope between the M-line to triad distance (MT) and SL was measured to be 0.44 +/- 0.01 (r > 0.9, p < 0.001). The mean ZT was 0.52 +/- 0.07 micron, which corresponds to a triad location approximately halfway along the thin filaments. These results do not support the traditional statement regarding triad location. Nor do these results support a similar recent study conducted using chemically skinned muscle fibres from rat extensor digitorum longus (also a homogeneously fast-twitch muscle of the hindlimb), in which a slope of 0.25 was observed between ZT and SL (r > 0.9, p < 0.01). These results are, however, in qualitative agreement with results using intact fibres from fast-twitch rat semitendinosus. Based upon known morphology, we suggest that the only structure supporting triad position is the SR itself, and that a non-homogeneous distribution of the SR within the sarcomere might be responsible for maintaining triad location near the mid-region of the thin filaments. We also suggest that there might be optimal design reasons for locating the triads at the mid-region of the thin filaments.

Animals↗

Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles.

Chronic foreign-body responses and muscular changes were examined following the implantation of active miniature stimulators into the hind limb muscles of cats for periods of up to three months. The radio-frequency (RF)-powered stimulators were injected into muscles through a 12-gauge hypodermic needle. The tissue responses around the active stimulators were compared histologically to those provoked by passive devices, broken glass, silicone tubing, polyester suture material coated with polybutylate, and two of the internal components of the stimulator (ferrite, integrated circuit chip). Active and passive stimulators produced similar, benign foreign-body reactions that resulted in an essentially identical fibrous capsule over time. The responses were similar to those produced by the internal components and the suture material, and were more modest than those produced by the broken glass. The capsule did not appear to interfere with the functionality of active devices because thresholds measured during the post-implantation survival period did not change significantly over time. Unexpectedly, the severity of the reaction differed significantly amongst the various target muscles. Medial gastrocnemius exhibited the most severe response, whereas tibialis anterior had the least reaction.

Animals↗

Effects of regional stimulation using a miniature stimulator implanted in feline posterior biceps femoris.

The effects of placement of a miniature implantable stimulator on motor unit recruitment were examined in the posterior head of cat biceps femoris. The implantable stimulator (13-mm long x 2-mm diameter) was injected either proximally near the main nerve branch, or distally near the muscle insertion, through a 12-gauge hypodermic needle. Glycogen-depletion methods were used to map the distribution of fibers activated by electrical stimulation. Muscle fibers were found to be depleted at most or all proximodistal levels of the muscle, but the density of depleted fibers varied transversely according to the stimulus strength and proximity of the device to the nerve-entry site. Thus, muscle cross sections often had a "patchy" appearance produced because different proportions of depleted fibers intermingled with undepleted fibers in different parts of the cross section. In other preparations, the force of muscle contraction was measured when stimuli of varying strengths were delivered by the stimulator positioned at the same proximal or distal sites within the muscle. Devices placed close to the nerve-entry site produced the greatest forces. Those placed more distally produced less force. As stimulus current and/or pulse width increased, muscle force increased, often in steps, until a maximum was reached, which was usually limited by the compliance voltage of the device to less than the force produced by whole nerve stimulation.

Animals↗

Speech-processing strategies designed for children.

The design of cochlear prosthetic hardware and speech-processing strategies has been driven largely by psychophysical data from postlingually deafened adults with implants. In such subjects, success is related to the ability of the electrical stimulation to evoke the same patterns of neural activity and hence the same percepts as were produced formerly by acoustic input. Adults differ greatly in their ability to make use of information provided through electrical stimulation, particularly as temporal patterns. Recent research suggests that the manner in which information is processed in the auditory nervous system can be influenced by the type of information that is available during development of hearing. Because cochlear prostheses are used increasingly in prelingually deaf children, we must face the difficult task of designing and testing speech-processing strategies that are more appropriate for developing nervous systems whose first and only experience with sound comes from electrical stimulation.

Acoustic Stimulation↗

Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs.

We describe the design, fabrication, and output capabilities of a microminiature electrical stimulator that can be injected in or near nerves and muscles. Each single-channel microstimulator consists of a cylindrical glass capsule with hermetically sealed electrodes in either end (2-mm diameter x 13-mm overall length). Power and digital control data can be transmitted to multiple implants (256 unique addresses) via a 2-MHz RF field created by an external AM oscillator and inductive coil. In vitro testing demonstrated accurate control of output pulsewidth (3-258 microseconds in 1-microseconds steps) and current (0-30 mA in two linear ranges of 16 steps each, up to 8.5 V available compliance voltage). Microstimulators were used successfully for chronic stimulation in hindlimb muscles of cats. Design and fabrication issues affecting yield and reliability of the packaging and electronics are discussed.

Action Potentials↗

Relationships between range of motion, lo, and passive force in five strap-like muscles of the feline hind limb.

The relationships between range of motion, optimal length for force production (lo), and passive force provide useful insights into the structure and function of muscles but are unknown for most individual muscles. We measured these values and examined their relationships in five strap-like muscles of the cat hind limb: caudofemoralis, semitendinosus, sartorius anterior, tenuissimus, and biceps femoris anterior. The range of motion relative to lo was found to vary significantly between different muscles and even between different specimens of the same muscle. The passive force-length (FL) curve was found to be correlated with both lo and lmax (maximal in situ muscle length) but was correlated more strongly with lmax. The mean passive force produced by these muscles at lmax was less than 7% of estimated maximal isometric force, suggesting that passive force may not be important in these muscles during normal activation patterns. The variance in passive FL curves between specimens of the same muscle was found to be significantly lower when length was scaled by lmax as opposed to lo. These results suggest that lmax may provide a more useful scaling factor for generic models of muscle. However, the passive length-tension properties of mammalian muscle appear to reflect a complex mix of structures at both the myofilament and connective tissue levels that may differ depending on muscle-fiber architecture and perhaps on the history of trophic influences on a particular specimen.

Animals↗

Mechanics of feline soleus: I. Effect of fascicle length and velocity on force output.

The aim of the present study was to quantify how fascicle length and velocity modify force production in cat soleus. A computerized muscle puller controlled the length and velocity of the whole-muscle. We recorded the force output at the tendon and the length of muscle fascicles using sonomicrometry during whole-muscle isometric and isokinetic contractions. Peak muscle stress was estimated as 31.8 +/- 4.1 N cm-2 (mean and SD) and optimal fascicle length, Lo, was estimated as 3.8 +/- 0.6 cm which corresponds to an optimal sarcomere length of 2.49 +/- 0.08 microns. The isometric force-length data followed closely the expected force-length relationship for cat sarcomeres. The force-velocity relationship was found to be similar in shape between cats, but the per cent increment of force over isometric levels for lengthening contractions was highly variable. Estimates of the kinematics of the fascicles based on whole-muscle length were systematically incorrect; whole-muscle velocity was 21% greater than fascicle velocity. The force-velocity data demonstrated consistent dependencies on fascicle length. At lengths below 0.7 Lo (1.74 microns), the shape of the force-velocity relationship was altered by the inclusion of a passive, repulsive force in the estimate of active isometric force. The shape of the force-velocity relationship changed at lengths greater than 0.7 Lo, but was restricted to lengthening velocities where the increment of force with respect to isometric levels was found to increase with fascicle length. This change in shape in the force-velocity relationship for lengthening contractions reveals a systematic, but previously unknown interdependence between fascicle length and velocity on muscle force production.

Animals↗

Mechanics of feline soleus: II. Design and validation of a mathematical model.

We have developed a mathematical model to describe force production in cat soleus during steady-state activation over a range of fascicle lengths and velocities. The model was based primarily upon a three element design by Zajac but also considered the many different features present in other previously described models. We compared quantitatively the usefulness of these features and putative relationships to account for a set of force and length data from cat soleus wholemuscle described in a companion paper. Among the novel features that proved useful were the inclusion of a short-length passive force resisting compression, a new normalisation constant for connective-tissue lengths to replace the potentially troublesome slack length, and a new length dependent term for lengthening velocities in the force-velocity relationship. Each feature of this model was chosen to provide the most accurate description of the data possible without adding unneeded complexity. Previously described functions were compared with novel functions to determine the best description of the experimental data for each of the elements in the model.

Animals↗

Effect of neck posture on patterns of activation of feline neck muscles during horizontal rotation.

The electromyographic (EMG) patterns of neck muscles were recorded during whole-body horizontal rotation in head-free, alert cats and head-restrained, decerebrate cats. In some trials the cervical column of the animal was oriented vertically, whereas in others it was oriented more horizontally. In alert cats making head movements that compensated for the motion of the platform, neck muscles with modulated patterns of activity could be divided into a subset whose individual EMG patterns changed significantly when the neck posture was altered (including longissimus capitis, obliquus capitis superior and scalenus anterior) and a subset whose individual EMG patterns were invariant regardless of neck posture (including obliquus capitis inferior, levator scapulae and complexus). In head-restrained, decerebrate cats, electromyograms from all implanted muscles were modulated similarly in phase with the platform position. Changing the orientation of the neck had little effect upon these EMG patterns evoked by the horizontal vestibulocollic reflex. One decerebrate cat with strong extensor tone was tested further under head-free conditions. There was very little compensatory head movement, but individual neck muscles displayed patterns of activity that were more similar to those observed in alert, head-free animals.

Adaptation, Physiological↗

Cuff electrodes for chronic stimulation and recording of peripheral nerve activity.

A comparative study of 5 different designs of nerve cuff electrodes was undertaken to determine their relative merits for stimulating and recording whole-nerve activity over extended periods of chronic implantation on large and small peripheral nerves in 8 cats. Four of the designs represent novel fabrication strategies, including 2 based on flexible, thin-film substrates and 2 based on dip-coating silicone elastomer on a cylindrical mandrel. Various advantages and shortcomings of these materials and designs are discussed in the context of the biophysical factors that influence these electrophysiological interfaces, particularly the problem of recording microvolt-level neurograms in the presence of millivolt-level electromyograms from adjacent muscles in freely behaving subjects. The most effective design was one in which a thin sheath of silicone rubber was wrapped around and intra-operatively sealed to a longitudinally slit, tripolar cuff made by dip-coating silicone over stranded stainless steel leads that were prepositioned on a mandrel using polyvinyl alcohol as a temporary adhesive. When properly installed, these electrodes had stable impedances, recruitment thresholds and relatively interference-free recording properties for the duration of this study (up to 9 weeks).

Animals↗

Neural signals for command control and feedback in functional neuromuscular stimulation: a review.

In current functional neuromuscular stimulation systems (FNS), control and feedback signals are usually provided by external sensors and switches, which pose problems such as donning and calibration time, cosmesis, and mechanical vulnerability. Artificial sensors are difficult to build and are insufficiently biocompatible and reliable for implantation. With the advent of methods for electrical interfacing with nerves and muscles, natural sensors are being considered as an alternative source of feedback and command signals for FNS. Decision making methods for higher level control can perform equally well with natural or artificial sensors. Recording nerve cuff electrodes have been developed and tested in animals and demonstrated to be feasible in humans for control of dorsiflexion in foot-drop and grasp in quadriplegia. Electromyographic signals, being one thousand times larger than electroneurograms, are easier to measure but have not been able to provide reliable indicators (e.g., of muscle fatigue) that would be useful in FNS systems. Animal studies have shown that information about the shape and movement of arm trajectories can be extracted from brain cortical activity, suggesting that FNS may ultimately be directly controllable from the central nervous system.

Electric Stimulation Therapy↗

Mechanical properties of aponeurosis and tendon of the cat soleus muscle during whole-muscle isometric contractions.

Recent studies have suggested that the mechanical properties of aponeurosis are not similar to the properties of external tendon. In the present study, the lengths of aponeurosis, tendon, and muscle fascicles were recorded individually, using piezoelectric crystals attached to the surface of each structure during isometric contractions in the cat soleus muscle. We used a surgical microscope to observe the surface of the aponeurosis, which revealed a confounding effect on measures of aponeurosis length due to sliding of a thin layer of epimysium over the proximal aponeurosis. After correcting for this artifact, the stiffness computed for aponeurosis was similar to tendon, with both increasing from around 8 F0/Lc (F0 is maximum isometric force and Lc is tissue length) at 0.1 F0 to 30 F0/Lc at forces greater than 0.4 F0. At low force levels only (0.1 F0), aponeurotic stiffness increased somewhat as fascicle length increased. There was a gradient in the thickness of the aponeurosis along its length: its thickness was minimal at the proximal end and maximal at the distal end, where it converged to form the external tendon. This gradient in thickness appeared to match the gradient in tension transmitted along this structure. We conclude that the specific mechanical properties of aponeurosis are similar to those of tendon.

Animals↗

Influence of materials and geometry on fields produced by cochlear electrode arrays.

Most cochlear prostheses use multichannel electrode arrays implanted in the scala tympani to generate multiple parallel channels of activity in the tonotopically mapped auditory nerve. Various materials and geometrical arrangements of contacts and locations within the scala tympani have been used, resulting in substantial differences in the required stimulus strengths and resulting spatial distributions of neural activity. Activated iridium (AIR) permits systematic adjustment of its metal-electrolyte interface properties by changing the degree of electrochemical activation. Planar equivalent models of bipolar cochlear electrode geometries using iridium have been built, and their impedance magnitude and phase versus frequency for various degrees of activation have been characterised. The electrical fields produced at various distances from bipolar contacts in saline are measured. In comparison to platinum and unactivated iridium, AIR provides a much lower metal-electrolyte interfacial impedance. When two AIR contacts are placed with their edges close together, the resulting field distributions are determined largely by the high (but safe) current densities at their apposed edges rather than the overall extent of the contacts. These edge effects permit a novel design for a bipolar array that produces N channels of radially distributed, non-overlapping fields and that requires only N + 1 contacts.

Cochlear Implants↗

Microminiature molding techniques for cochlear electrode arrays.

We provide a general method for producing a variety of small, complex electrode arrays based on injection molds produced using computer-aided drafting and machining (CAD-CAM) procedures and a novel method for connecting to the very fine electrical leads associated with the individual contacts of such arrays. Cat-sized cochlear electrode arrays with up to eight contacts were built according to these methods and their electrical contacts were characterized in vitro by impedance spectroscopy and in vivo by monitoring impedance for over 1 year of intermittent stimulation in chronically instrumented animals.

Animals↗

Toward the ultimate metal microelectrode.

The performance of metal microelectrodes for stimulating and recording neuronal action potentials depends on precise control of their geometrical, electrical and mechanical properties. We describe a combination of materials whose properties approach fundamental physical limitations on achievable performance and reproducible fabrication techniques that provide probes with very small dimensions. Pure iridium wire is electrolytically sharpened, vapor-coated with Parylene-C insulation and the tip exposed using an automatically steerable UV laser. Electrochemical activation of the iridium increases the capacitance of the metal-electrolyte interface so that the overall impedance in the relevant frequency band (100-10,000 Hz) is dominated by the access resistance of the surrounding tissues.

Electric Conductivity↗