Search PubMed⌕ Search

Biomedical subjects

G Durack

Publications and source records attributed to G Durack.

10 recordsLinked to original sources

Modulator of heme biosynthesis induces apoptosis in leukemia cells.

OBJECTIVE: The purpose of this research is the investigation of the possible cause(s) of the dark-cell death phenomenon induced by 1,10-phenanthroline (Oph), a porphyrin biosynthesis modulator. SUMMARY BACKGROUND DATA: We have previously shown that porphyrin biosynthesis modulators, such as Oph, which is also an iron-chelating agent, enhance protoporphyrin IX (Proto) accumulation in mammalian neoplastic cells treated with delta-aminolevulinic acid (ALA). As a result of the enhanced Proto accumulation, a significant increase in photodynamic damage was observed under illumination. Also tetrapyrrole and heme-biosynthesis modulators have been shown to cause death in treated insect larvae in darkness, a phenomenon referred to as dark-cell death. Dark-cell death was also observed in Oph + ALA-treated transformed mammalian cells. METHODS: Neoplastic cells were treated with ALA, Oph, and ALA + Oph, and the following cell properties were investigated: growth arrest, membrane permeability, cell survival, nucleosomal cleavage, and cell cycle alterations. RESULTS: It was observed that Oph but not ALA induced growth arrest, in a T-cell leukemia line (MLA 144) as assessed by reduction in DNA synthesis. Exogenous Proto and isomers of Oph lacking the iron-chelating property of Oph also caused a dose-dependent inhibition of proliferation in MLA 144 cells. Although the plasma membrane of Oph-treated cells remained intact following 3 h of dark-incubation, the cells exhibited DNA internucleosomal cleavage, characteristic of cells undergoing apoptosis. Cell cycle analysis using the DNA intercalating dye propidium iodide (PI) coupled to flow cytometry, indicated that 81 +/- 5.6% of Oph-treated MLA 144 cells were apoptotic, with the majority of the cells arrested in the early S phase. On the other hand, treatment with either ALA or Proto did not alter the cell cycle. Also, using a double-labeling protocol with Hoechst 33342, and PI, and analysis by flow cytometry, Oph-treated cells were found to be 82% apoptotic after 3 h of dark-incubation. Apoptosis was reduced by 75% (p < 0.05) by the cytoplasmic protein synthesis inhibitor cycloheximide. CONCLUSIONS: These results indicate that in addition to enhancing Proto accumulation, the heme biosynthesis modulator Oph also induces growth arrest and apoptosis in transformed cells in darkness.

Aminolevulinic Acid↗

FITC-poly-D-lysine conjugates as fluorescent probes to quantify hapten-specific macrophage receptor binding and uptake kinetics.

A series of fluorescein derivatized poly-D-lysine (FITC-PDL) probes were used to elucidate the role of fluorescein in receptor binding of fluorescein-conjugated macromolecules to J774 murine macrophages. Poly-D-lysine served to eliminate receptor recognition of the carrier due to the biologically inert nature of the D-isomer. This concept enabled the focused investigation of the role played by fluorescein in receptor recognition, binding and internalization. Results revealed dependency of cellular uptake on polymer concentration, hapten density and accessibility. The results differed from those previously obtained with FITC-BSA in that saturating fluorescein densities on the poly-D-lysine polymer resulted in diminished rates of uptake by macrophages. Receptor-mediated endocytosis via clathrin-coated pits was concluded based on results that showed inhibition of FITC-PDL uptake by intracellular K+ depletion but not by the macropinocytosis inhibitor, amiloride. Further, FITC-PDL was found to inhibit the endocytic uptake of FITC-BSA suggesting competition between the two probes at the level of a macrophage receptor. Association rates (kon) for binding to the macrophage surface were measured for the various FITC-PDL probes based on fractional receptor occupancies. Results are discussed on the basis of receptor recognition of fluorescein in J774 macrophages and the requirements for this recognition which include appropriate spacing and accessibility of the hapten moieties to facilitate receptor crosslinking.

Amiloride↗

A flow cytometric method for measurement of intracellular chloride concentration in lymphocytes using the halide-specific probe 6-methoxy-N-(3-sulfopropyl) quinolinium (SPQ).

A flow cytometry method using the halide-specific fluorescent dye, 6-methoxy-N-(3-sulfopropyl) quinolinium (SPQ), has been developed to measure intracellular chloride concentration in single cells. Collisions with chloride quench the fluorescence of SPQ, making it possible to relate the measured fluorescence intensity to chloride concentration with a Stern-Volmer equation. To demonstrate the method, porcine lymphocytes were loaded in vitro, using a hypotonic method, with 5 mM SPQ. Fluorescence excitation was provided by a UV laser and the fluorescence emission intensity at 485 nm was recorded. Calibration was performed by using 7 microM nigericin (a K/H antiporter) and 10 microM tributyltin (a Cl/OH antiporter) to equilibrate the concentrations of intracellular and extracellular chloride. Calibration measurements were made for chloride concentrations between 0 mM and 140 mM. The calibration produced a Stern-Volmer quenching constant of 16.2 M(-1) which was used to relate measured cell fluorescence to intracellular chloride concentration. The intracellular chloride concentration for fresh porcine lymphocytes was determined to be 56.2 +/- 3.3 mM. Stable loading of cells with 5 mM SPQ was accomplished in 15 minutes, leakage of SPQ from the cells was minimal, and over 95% of the cells remained viable after loading.

Animals↗

Analysis of the intracellular processing of proteins: application of fluorescence polarization and a novel fluorescent probe.

Previous studies indicated that fluorescein derivatized bovine serum albumin was an ideal probe to monitor the time-dependent kinetics of antigen processing in the murine macrophage cell line J774. Whereas previous work focused on fluorescence intensity measurements, the present study relied on fluorescence polarization to dissect the local environment of the fluorescent hapten-protein within the endocytic system of the cell. A steady increase in both fluorescence intensity and fluorescence polarization of the cell population was detected for the first 100 min. However, at 100 min, a plateau in both fluorescence intensity and polarization was observed and was followed by a decrease in fluorescence polarization and a corresponding increase in fluorescence intensity. Western blot analyses revealed that the decrease in fluorescence polarization was due to proteolytic degradation of the probe within the cell. Using a combination of in vitro experiments and an additional fluorescent probe, it was determined that the initial increase in fluorescence polarization was due to movement of the probe through a pH gradient within the cell, suggestive of transport through the endocytic system. By combining fluorescence polarization, flow cytometry, and a unique fluorescent enhancement substrate, these studies represented a novel approach for monitoring intracellular trafficking and processing of proteins within macrophages.

Animals↗

Evidence for hapten recognition in receptor-mediated intracellular uptake of a hapten-protein conjugate by murine macrophage.

Fluorescein-derivatized bovine serum albumin (FITC-BSA) was used as an exogenous antigen and fluorescent probe to measure the kinetics of antigen uptake into the endocytic pathway of murine macrophage, J774, using flow cytometry. Results revealed dependency of the rate of antigen uptake on epitope density (moles FITC/mole BSA) implicating a role for FITC in the endocytosis of the derivatized antigen. In addition, inhibition of clathrin-coated pit formation in macrophage resulted in significantly reduced uptake of differentially labeled FITC BSA probes indicating receptor-mediated endocytosis via clathrin-coated pits. Fluoresceinamine (I) was found to inhibit the endocytic uptake of FITC-BSA at 10(-6) M. Determination of fractional receptor occupancies in macrophage upon binding different FITC BSA probes and calculation of the corresponding association rates (k(on)) for these binding events yielded values of 4.2+/-0.2 x 10(6)/M/min for FITC5BSA and 1.9+/-0.1 x 10(7)/M/min for FITC22BSA, respectively, at 37 degrees C. The five-fold difference in the rates of binding and endocytosis between the two probes was discussed on the basis of receptor cross-linking by a multivalent ligand (FITC22BSA), in contrast to monovalent ligand binding, on the cell surface that would lead to more rapid and efficient internalization of the FITC22BSA antigen.

Animals↗

Macrophage mediated processing of an exogenous antigenic fluorescent probe: time-dependent elucidation of the processing pathway.

To elucidate time-dependent pathways and mechanisms involved in antigen processing, a fluorescent probe suitable to monitor several steps within this pathway was developed. Previous studies utilizing two-photon fluorescence microscopy with time resolved and intensity imaging demonstrated that the probe, fluorescein derivatized BSA, was localized to the endocytic system and degraded over an extended period of time. However, an additional method, flow cytometry, was required to monitor the kinetics of these intracellular events and to better assess the total cell population. Flow cytometric studies indicated that the antigen entered an acidic intracellular environment consistent with the endocytic system of the macrophage. Additional experiments suggested that minimal proteolytic degradation began 10 min after addition of the antigenic probe while extensive enzymatic degradation did not occur until 180-200 min. Inhibitor studies indicated that degradation of the probe was dependent upon both acidic pH and ATP synthesis as well as all four classes of proteases. Experiments involving specific protease inhibitors also revealed that various classes of proteases were active at different time points throughout the processing of the probe. By combining these results with additional kinetic data, a model for the sequence of events involved in the processing of FITC10BSA was proposed. More importantly, these studies represented some of the first time-dependent kinetic measurements of antigen processing in living cells.

Adenosine Triphosphate↗

Rapid multivariate analysis and display of cross-reacting antibodies on human leukocytes.

We present an application which can rapidly determine the binding patterns of monoclonal antibodies on mixed populations of cells simultaneously in a single rapid analysis. It is an application of the tube identifier parameter (TIP) system which can provide fully correlated list-mode data of the entire patient phenotype in a single file. Using the phenogram analytical display, we are able to determine the cross-reacting antibodies for an entire antibody panel for each cell type. This information can be displayed in a single plot. Using light scatter gating to select different populations of lymphocytes, monocytes, and neutrophils, phenograms can be simultaneously generated. This provides a directly comparable means of displaying the positive and negative binding characteristics of each antibody on each cell population. Any marker combination that is abnormal will be identifiable in the phenogram. Additionally, by plotting the fluorescence distributions of each marker beside one another (termed overview), quantifiable differences in intensity can be determined. There are 3 major benefits of the proposed analysis. By using the TIP concept, several sets of antibodies can be compared simultaneously. Any light scatter gate can be used and this gate can be changed on one histogram or plot, yet apply to the total analysis. Data analysis is particularly rapid since the entire phenotype of a patient can be evaluated by performing a single rapid analysis.

Antibodies↗

Integration of a barcode reader with a commercial flow cytometer.

This report describes the application and installation of a barcode reader on a standard EPICS Elite flow cytometer. The barcode reader system eliminates keyboard entry of sample information on the cytometer. The system automates the transfer of sample information already present in our laboratory database to the cytometer at run time. The system uses a standard "off-the-shelf" bar code wand with a personal computer keyboard interface and requires no additional software at run time. No typing of sample information is required by the operator at any stage of normal sample operation at the cytometer. All operations are automatically coded into the cytometry software using the macro functions of the software. Tubes are inserted into the tube reader and sample information is transferred automatically into the cytometer. We have found that the system allows rapid and continuous operation of routine clinical and research samples. This automated data entry also reduces the possibility of data input errors.

Electronic Data Processing↗

An innovation in flow cytometry data collection and analysis producing a correlated multiple sample analysis in a single file.

The problems associated with rapid analysis and interpretation of data from multicolor immunofluorescence panels have been a formidable barrier to their routine use. Using present flow cytometry concepts, a panel of 11 tubes each containing multiple phenotypic markers or controls requires postdata acquisition manipulation of many multiparameter histogram and listmode files. We have developed a method that compresses all of the information from such a panel into a single listmode data file during run time. A single data file is used to record the entire phenotypic analysis for a particular patient or series within an experiment. This is accomplished by the incorporation of a tube identifier parameter (TIP) as well as the fluorescence and light scatter parameters normally collected. The TIP can then be used for gating discrimination of any tube or set of tubes within a panel. When the TIP is correlated with the PRISM parameter the entire patient phenotypic image can be represented within a single two-parameter histogram we have called a phenogram. This phenogram can be generated in real time, providing on-line preprocessing of a complex multicolor experiment. By examining the image created by the phenogram it is possible to rapidly flag abnormalities such as incorrect gating. This procedure was carried out on an EPICS Elite flow cytometer in its standard configuration with the addition of hardware to provide an input for the TIP.

Data Collection↗

Time interval gating for analysis of cell function using flow cytometry.

We propose a method which significantly shortens the time required for both the collection and analysis of data derived from multiple sample, flow cytometric kinetic assays. We have defined the term Time Interval Gating (TIG) to describe this method. TIG effectively allows one flow cytometer to concurrently monitor several samples over the course of a kinetic assay. Data for all samples are stored in a single FCS 2.0 compatible listmode data file which we refer to as the TIG data file. TIG is adaptable to most commerical flow cytometers. Standard listmode analysis software can be used to analyze the TIG data files and correlate any combination of tubes and/or time intervals from the assay. Results for the entire assay can be displayed on a single two parameter plot. This paper describes how TIG is applied to neutrophil oxidative burst measurement using a standard EPICS Elite flow cytometer. In this assay, 11 samples were each monitored for 30 min to identify the extent to which volatile organic chemicals (VOCs) inhibited the oxidation of DCFH in stimulated neutrophils. TIG makes the oxidative burst assay practical for high volume screening by reducing the overall flow cytometer and analysis time required by a factor of ten. In addition, TIG provides an organized approach to managing data acquisition on instruments equipped with automated sampling systems.

Flow Cytometry↗