Search PubMed⌕ Search

Biomedical subjects

G Douglas

Publications and source records attributed to G Douglas.

At least 19 recordsLinked to original sources

Cardiovascular consequences of life-long exposure to dietary isoflavones in the rat.

Dietary soy intake in man is proposed to provide cardiovascular protection, but it is not established whether this property is attributable to the soy protein per se or to associated dietary isoflavones. This investigation aimed to establish whether the dietary isoflavones in soy protein affect cardiovascular function. Ten days prior to mating, male and female Wistar rats were habituated to either a soy based isoflavone rich diet (plasma concentration 1.87 micromol l(-1) isoflavones) or the same diet after isoflavone elution (plasma isoflavone not detectable). Offspring were weaned onto and maintained on the same diet as their dam and sire for 6 months. Blood pressure, and constrictor and dilator responses in the aorta and mesenteric resistance arteries were assessed at 3 and 6 months of age. There was no effect of isoflavone removal from the diet on blood pressure, heart rate, aortic function or mesenteric artery contractile function, at either 3 or 6 months of age. Resistance mesenteric arteries from 6-month-old female rats fed the isoflavone rich diet demonstrated a modest increase in arterial distensibility compared with those fed the depleted diet, and mesenteric arteries from male and female rats fed the isoflavone rich diet showed increased sensitivity to acetylcholine. In summary, the isoflavone content of soy protein has no influence on blood pressure in healthy rats fed a diet based on soy protein, but influences small artery function.

Animals↗

Management of COPD in primary care in north-east Scotland.

INTRODUCTION: We wished to obtain a snapshot of current service provision and how this could best be developed approximately one year on from the introduction of the National Institute for Clinical Excellence (NICE) guidelines for the management of chronic obstructive pulmonary disease (COPD) and the inclusion of COPD care in the New GMS Contract Quality and Outcomes Framework (QOF). METHODOLOGY: A questionnaire-based survey sent to every general practice (n = 84) in Grampian. RESULTS: Responses were received from 75 of 84 practices (89%). Questionnaires were returned by both general practitioners (GPs) and practice nurses in 45 practices (54%). All responding practices reported that they had COPD registers. 60/75 (80%) of practices reported having a dedicated COPD clinic; 70/75 (93%) had a spirometer. Areas identified for service development were: quality assuring training in COPD care and spirometry; expanding pulmonary rehabilitation provision (86%), delivering this service locally (54%) and in primary care (75%); standardising referral, assessment and communication about provision of home oxygen; training in pulse oximetry (71%). CONCLUSION: This data has important implications for the validity of the quality indicators (QOF) under the new GMS contract. Our respondents identified areas where the new GMS contract QOF could be improved, as well as providing useful suggestions for service development. Respondents recognised that not all clinical services can be effectively delivered by general practice with data supporting the development of intermediate care services for people with COPD.

Humans↗

Enhanced vascular responses to adrenomedullin in mice overexpressing receptor-activity-modifying protein 2.

Adrenomedullin (AM) levels are elevated in cardiovascular disease, but little is known of the role of specific receptor components. AM acts via the calcitonin receptor-like receptor (CLR) interacting with a receptor-activity-modifying protein (RAMP). The AM1 receptor is composed of CLR and RAMP2, and the calcitonin gene-related peptide (CGRP) receptor of CLR and RAMP1, as determined by molecular and cell-based analysis. This study examines the relevance of RAMP2 in vivo. Transgenic (TG) mice that overexpress RAMP2 in smooth muscle were generated. The role of RAMP2 in the regulation of blood pressure and in vascular function was investigated. Basal blood pressure, acute angiotensin II-raised blood pressure, and cardiovascular properties were similar in wild-type (WT) and TG mice. However, the hypotensive effect of IV AM, unlike CGRP, was enhanced in TG mice (P<0.05), whereas a negative inotropic action was excluded by left-ventricular pressure-volume analysis. In aorta relaxation studies, TG vessels responded in a more sensitive manner to AM (EC50, 8.0+/-1.5 nmol/L) than WT (EC50, 17.9+/-3.6 nmol/L). These responses were attenuated by the AM receptor antagonist, AM(22-52), such that residual responses were identical in all mice. Remaining relaxations were further inhibited by CGRP receptor antagonists, although neither affected AM responses when given alone. Mesenteric and cutaneous resistance vessels were also more sensitive to AM in TG than WT mice. Thus RAMP2 plays a key role in the sensitivity and potency of AM-induced hypotensive responses via the AM1 receptor, providing evidence that this receptor is a selective target for novel therapeutic approaches.

Adrenomedullin↗

A high-fat diet during rat pregnancy or suckling induces cardiovascular dysfunction in adult offspring.

Epidemiological and animal studies suggest that diet-induced epigenetic modifications in early life can contribute to development of the metabolic syndrome in adulthood. We previously reported features of the metabolic syndrome in adult offspring of rats fed a diet rich in animal fat during pregnancy and suckling. We now report a study to compare the relative effects of high-fat feeding during 1) pregnancy and 2) the suckling period in the development of these disorders. As observed previously, 6-mo-old female offspring of fat-fed dams suckled by the same fat-fed dams (OHF) demonstrated raised blood pressure, despite being fed a balanced diet from weaning. Female offspring of fat-fed dams "cross fostered" to dams consuming a control diet during suckling (OHF/C) demonstrated raised blood pressure compared with controls (OC) [systolic blood pressure (SBP; mmHg) means +/- SE: OHF/C, 132.5 +/- 3.0, n = 6 vs. OC, 119.0 +/- 3.8, n = 7, P < 0.05]. Female offspring of controls cross fostered to dams consuming the fat diet (OC/HF) were also hypertensive [SBP (mmHg) 131.0 +/- 2.5 mmHg, n = 6 vs. OC, P < 0.05]. Endothelium-dependent relaxation (EDR) of male and female OHF and OHF/C mesenteric small arteries was similar and blunted compared with OC (P < 0.001). OC/HF arteries showed profoundly impaired EDR (OC/HF vs. OHF, P < 0.001). OHF/C and OC/HF demonstrated hyperinsulinemia and increased adiposity. Features of the metabolic syndrome in adult offspring of fat-fed rats can be acquired both antenatally and during suckling. However, exposure during pregnancy confers adaptive protection against endothelial dysfunction induced by maternal fat feeding during suckling.

Animals↗

Papnet-assisted cytological diagnosis intensifies the already marked variability among cytological laboratories.

OBJECTIVE: The main objective was to assess the sensitivity, specificity and reliability of PAPNET-assisted diagnosis in comparison with conventional screening. SETTING: Seven Italian and one English University or Research Institutes, and a random sample of an other 20 Italian Laboratories of the Italian National Health Service (INHS) provided the cervical smears. METHODS: During the training phase every center examined in rotation four sets of slides for a total of 300 representative slides. Afterwards, 900 "positive" slides were added to the 3,100 slides which were collected consecutively without any selection or exclusion. The eight main centers were divided into four couples and each couple of centers examined 775 slides with the PAPNET system, "blindly" to the original diagnosis. An expert cytopathologist (M.A.) of the National Institute of Health (NIH) reassessed 40% of the slides with an original negative diagnosis to evaluate the false negative rate. Two expert NIH cytopathologists (M.A., G.M.) re-examined all slides where a disagreement had been observed between the original and one or both of the study diagnoses. The main analyses concerned the following three main categories: WNL and unsatisfactory for evaluation; ASCUS, AGUS and LSIL; HSIL and carcinoma. A special algorithm was devised to define the reference diagnosis for sensitivity and specificity assessment. RESULTS: Laboratories, even belonging to the same couple, classified as "no review" a very different proportion of slides ranging from 35% to 74%. The index of kappa agreement between the members of couples examining the same sets of slides was low or very low, ranging from 0.30 to 0.03. The sensitivity of the review classification was particularly low in some laboratories. Surprisingly, only a small correlation was observed between the sensitivity of the review classification and the proportion of slides classified as "review". The "tentative" diagnosis on PAPNET tiles of the "review" slides was almost as reliable as the microscopic diagnosis. In the overall performance, there were many significant differences among the eight laboratories. The best laboratory had a sensitivity of 95% and a specificity of 96%. At least three laboratories displayed unacceptably low sensitivity and one a very low specificity. CONCLUSION: Altogether these results seem to confirm that there are wide differences among cytological laboratories per se, and that these differences are intensified by the use of an instrument like PAPNET. The huge variation in performance may be explained by differences in basic skills and by different training, but it is difficult to understand exactly what could have been done to reduce it.

Autoanalysis↗

Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: a systematic review of the literature.

BACKGROUND: Asthma and chronic obstructive pulmonary disease (COPD) are common diseases of the airways and lungs that have a major impact on the health of the population. The mainstay of treatment is by inhalation of medication to the site of the disease process. This can be achieved by a number of different device types, which have wide variations in costs to the health service. A number of different inhalation devices are available. The pressurised metered-dose inhaler (pMDI) is the most commonly used and cheapest device, which may also be used in conjunction with a spacer device. Newer chlorofluorocarbons (CFC)-free inhaler devices using hydrofluoroalkanes (HFAs) have also been developed. The drug is dissolved or suspended in the propellant under pressure. When activated, a valve system releases a metered volume of drug and propellant. Other devices include breath-actuated pMDIs (BA-pMDI), such as Autohaler and Easi-Breathe. They incorporate a mechanism activated during inhalation that triggers the metered-dose inhaler. Dry powder inhalers (DPI), such as Turbohaler, Diskhaler, Accuhaler and Rotahaler, are activated by inspiration by the patient. The powdered drug is dispersed into particles by the inspiration. With nebulisers oxygen, compressed air, or ultrasonic power is used to break up solutions or suspensions of medication into droplets for inhalation. The aerosol is administered by mask or by a mouthpiece. There has been no previous systematic review of the evidence of clinical effectiveness and cost-effectiveness of these different inhaler devices. OBJECTIVES: To review systematically the clinical effectiveness and cost-effectiveness of inhaler devices in asthma and COPD. METHODS: The different aspects of inhaler devices were separated into the most clinically relevant comparisons. Methods involved systematic searching of electronic databases and bibliographies for randomised controlled trials (RCTs) and systematic reviews. Pharmaceutical companies and experts in the field were contacted for further information. Trials that met the inclusion criteria were appraised and data extraction was under-taken by one reviewer and checked by a second reviewer, with any discrepancies being resolved through agreement. RESULTS--IN VITRO CHARACTERISTICS VERSUS IN VIVO TESTING AND CLINICAL RESPONSE: There is evidence that when comparative testing is performed on inhaler devices using the same methods, there is some correlation between particle size measurements and clinical response. However, the measurements are dependent upon the methods used, and a single measure of a device in isolation is of limited value. Also, there is little data on comparing devices of different types. There is currently insufficient data to verify the ability of in vitro assessments to predict inhaler performance in vivo. RESULTS--EFFECTIVENESS OF METERED-DOSE INHALERS FOR THE DELIVERY OF CORTICOSTEROIDS IN ASTHMA: The review of three trials in children and 21 trials in adults demonstrated no evidence to suggest clinical benefits of any other inhaler device over a pMDI in corticosteroid delivery. RESULTS--EFFECTIVENESS OF METERED-DOSE INHALERS FOR THE DELIVERY OF BETA-AGONISTS IN STABLE ASTHMA: In children, 11 studies were reviewed, of which seven compared the Turbohaler with the pMDI. One study found a significant treatment difference in peak expiratory flow rate, although there were differences in the patients' baseline characteristics. In adults, a review of 70 studies found no demonstrable difference in the clinical bronchodilator effect of short-acting b2-agonists delivered by the standard pMDI compared with that produced by any other DPI, HFA-pMDI or the Autohaler device. The finding that HFA-pMDIs may reduce treatment failure and oral steroid requirement in beta-agonist delivery needs further confirmatory research in adequately randomised clinical trials. RESULTS--EFFECTIVENESS OF NEBULISERS VERSUS METERED-DOSE INHALERS FOR THE DELIVERY OF BRONCHODILATORS IN STABLE ASTHMA: In children, three included trials compared different devices with a nebuliser and demonstrated no evidence of clinical superiority of nebulisers over inhaler devices in bronchodilator delivery. A total of 23 studies in adults found no equivalence for the main pulmonary outcomes and no evidence of difference in other outcomes. RESULTS--EFFECTIVENESS OF METERED-DOSE INHALERS FOR THE DELIVERY OF BETA-AGONISTS IN COPD: Only two studies were included in this review. No evidence of clinical difference was found in beta-agonist delivery. RESULTS--EFFECTIVENESS OF NEBULISERS VERSUS METERED-DOSE INHALERS FOR THE DELIVERY OF BRONCHODILATORS IN COPD: Evidence from 14 trials demonstrated equivalence for the main outcomes of pulmonary function. For other outcomes there was no evidence of treatment difference in bronchodilator delivery. RESULTS--PATIENTS' ABILITY TO USE METERED-DOSE INHALERS: Differences among studies and the heterogeneity of the results make it difficult to draw conclusions about inhaler technique differences between device types. The review of technique after teaching the correct technique suggests that there is no difference in patients' ability to use DPI or pMDIs. RESULTS--ECONOMIC ANALYSIS: The total number of NHS prescriptions for inhaler therapy for asthma in 1998 was over 31 million, with a net ingredient cost in excess of 392 million GB pounds. This economic assessment uses decision analysis to estimate the relative cost-effectiveness of inhaler devices for the delivery of bronchodilator and corticosteroid inhaled therapy. Overall, there were no differences in patient outcomes among the devices. On the assumption that the devices were clinically equivalent, pMDIs were the most cost-effective devices for asthma treatment. CONCLUSIONS: This systematic review examined the evidence from clinical trials evaluating the clinical effectiveness of different inhaler devices in the delivery of inhaled corticosteroids and beta2-bronchodilators for patients with asthma and COPD. The evidence from the published clinical literature demonstrates no difference in clinical effectiveness between nebulisers and alternative inhaler devices compared to standard pMDI with or without a spacer device. The cost-effectiveness evidence therefore favours pMDIs (or the cheapest inhaler device) as first-line treatment in all patients with stable asthma unless other specific reasons are identified. Patients can use pMDIs as effectively as other inhaler devices as long as the correct inhalation technique is taught. CONCLUSIONS--RECOMMENDATIONS FOR RESEARCH: Further clinical trials are required to demonstrate any differences in the clinical effectiveness and cost-effectiveness of inhaler devices and nebulisers compared with pMDIs. These should be of sufficient statistical power and methodological rigour to demonstrate any clinical benefit. Trials should be undertaken in community settings to ensure the generalisability of results. Outcome measures should be more patient-centred and report adverse effects more completely. Reporting of data from trials should be improved.

Adolescent↗

Time perception in boys with attention-deficit/hyperactivity disorder according to time duration, distraction and mode of presentation.

In a recent theoretical model of attention-deficit/hyperactivity disorder (ADHD), Barkley (1997a) predicted that ADHD children experience impairments in their psychological sense of time. This was demonstrated in a series of experiments by Barkley, Koplowicz, Anderson, and McMurray (1997). The present study sought to investigate the effects of ADHD subtype, stimulus duration, mode of presentation (visual versus auditory) and distractors on the performance of a simple time reproduction task. Data were obtained from 44 ADHD children (14 predominantly inattentive and 30 combined type) and 44 age-matched Controls using the Time Perception Application version 1.0 (Barkley, University of Massachusetts Medical Center, 1998). Results revealed that the ADHD children made significantly larger errors on Visual time reproduction tasks than the Controls, regardless of ADHD subtype or the presence of distractors. Furthermore, ADHD children were more likely to overestimate the shorter time intervals (0.5 and 2 s) and underestimate the longer time intervals (3, 4 and 6 s) relative to Controls. No group differences were observed on the auditory time reproduction task, with both ADHD and Control groups consistently underestimating the durations to be reproduced. The results of this study provide further support for the prediction that children with ADHD have an impaired sense of time.

Acoustic Stimulation↗

Differential patterns of executive function in children with attention-deficit hyperactivity disorder according to gender and subtype.

The present investigation examined differential patterns in executive functions of children with attention-deficit hyperactivity disorder (ADHD; no diagnosed comorbid disorders) according to subtype and gender, and identified instrumentation sensitive to executive function in children aged 6 to 12 years with ADHD. Data were obtained from 94 children diagnosed with ADHD (predominantly inattentive, n = 32, ADHD combined, n = 62), and from 28 controls. Participants with ADHD, who were unmedicated at the time of testing, were administered five tests of executive function (the Wisconsin Card Sorting Test, the Stroop Color-Word Test, the Matching Familiar Figures Test, the Trail Making Test, and the Tower of London). A two-way multivariate analysis of covariance with age as the covariate and subtype and gender as the independent variables was conducted on all of the tests administered. While children with ADHD predominantly inattentive and those with ADHD combined differed from controls, it was only the latter subtype that differed significantly in perseveration and response inhibition. The absence of diagnosed comorbidity in the children with ADHD at the time of test administration demonstrates that the impairments in executive function are clearly located in ADHD, particularly in the ADHD combined subtype, thus providing support for Barkley's proposed unifying theory of ADHD.

Attention Deficit Disorder with Hyperactivity↗

Information resources assessment of a healthcare integrated delivery system.

While clinical healthcare systems may have lagged behind computer applications in other fields in the shift from mainframes to client-server architectures, the rapid deployment of newer applications is closing that gap. Organizations considering the transition to client-server must identify and position themselves to provide the resources necessary to implement and support the infrastructure requirements of client-server architectures and to manage the accelerated complexity at the desktop, including hardware and software deployment, training, and maintenance needs. This paper describes an information resources assessment of the recently aligned Pennsylvania regional Veterans Administration Stars and Stripes Health Network (VISN4), in anticipation of the shift from a predominantly mainframe to a client-server information systems architecture in its well-established VistA clinical information system. The multimethod assessment study is described here to demonstrate this approach and its value to regional healthcare networks undergoing organizational integration and/or significant information technology transformations.

Computer Communication Networks↗

Reputation enhancement theory and adolescent substance use.

Data pertaining to self-reported substance use, reputation enhancement, self-concept and coping strategies were obtained from 1,204 Western Australian metropolitan state high school adolescents using the High School Student Activity Questionnaire. Previous research has identified low self-concept levels and inadequate coping strategies as being major contributors to adolescent substance use. The findings of the present research offer some support for this. A 4 x 2 x 3 MANOVA revealed, however, that reputation enhancement differentiated between current substance users, ex-users and non-users to a greater extent than either self-concept levels or coping strategies. Differences between male and female students, however, were identified more through self-concept and coping variables than by reputation enhancement variables. No interaction effect and no main effect for year group were present. The implications for drug education are discussed.

Adaptation, Psychological↗

International Commission for Protection Against Environmental Mutagens and Carcinogens. Genetic risk extrapolation from animal data to human disease. A Taskgroup Report. No. 00105.

This report describes a model for producing quantitative genetic risk assessments for human populations. The model is patterned after current methods used in cancer risk analysis. The risk to humans is expressed as the number of additional dominant genetic diseases added to the existing genetic burden, in the offspring of the exposed individuals.

Animals↗

Plasma nitrate concentration and urinary nitrate excretion in patients with gastroenteritis.

The concentration of nitrate (the stable oxidation product of nitric oxide) in plasma and its excretion in urine was measured in 20 patients with a diagnosis of gastroenteritis. On day 1 of the illness plasma nitrate concentration was significantly elevated compared with a healthy control population (92.7 +/- 17.0 mumol/l vs. 33.1 +/- 1.6 mumol/l; P < 0.001) and continued to be elevated on days 2 and 3. Urinary nitrate excretion was also elevated. The plasma nitrate concentration correlated with disease severity as assessed by stool frequency and plasma urea concentration. Plasma nitrate concentration may be a sensitive and clinically useful indicator of severity of gastroenteritis.

Adult↗

The short-time effect of latanoprost on the intraocular pressure in normal pressure glaucoma.

Latanoprost, a prostaglandin analogue, was given topically to 20 patients with normal pressure glaucoma in a double masked randomized study. Either latanoprost 0.006% or placebo (vehicle) was administered twice a day for 14 days. Latanoprost caused a statistically significant (p < 0.001) reduction in intraocular pressure from a diurnal baseline level of 16.8 to 14.3 mmHg, as measured on day 14. Latanoprost was well tolerated.

Administration, Topical↗