Publications and source records attributed to G Dorffner.

9 recordsLinked to original sources

Unsupervised continuous sleep analysis.

One aim of the EU-funded project SIESTA was to develop a new way of describing the human sleep-wake continuum with high temporal resolution, and independent of subjective rules, to serve as an alternative to traditional sleep scoring. Here, we report new findings obtained with a fully automatic, probabilistic sleep-analyzer using Hidden Markov Models (HMMs) based on data from a single electroencephalogram (EEG) channel. HMMs allow the analysis of non-stationary time series by modeling both the probability density functions of locally stationary data and the transition probabilities between these stable states. In the context of sleep analysis, the locally stable states can be thought of as sleep stages. The sleep-wake continuum was modeled as a mixture of three different processes by defining a three-state Gaussian Observation HMM (GOHMM). No class information from human scorers was used to train the model. The probabilities of being in any of the three states at each point in time roughly indicate the amount of wakefulness, deep sleep and rapid-eye-movement (REM) sleep with a one-second time resolution. Although it was not the aim to replicate the traditional Rechtschaffen and Kales (R&K) scoring, pseudo R&K hypnograms were constructed from the probability plots in order to compare the analyzer results with classical sleep stages by human experts. We expected that the analyzer would be able to classify data correctly from the "cornerstones" of human sleep (wakefulness, deep sleep, and REM sleep). Contrary to our previous efforts, we trained the HMMs on data from two different sleep laboratories separately, instead of generalizing data from diverse laboratories. While these stages could be detected with an accuracy of around 80% at the sleep laboratory for which we already had achieved the best results, there was no improvement from previous results by the training of a separate model in the other laboratory. This finding indicates clear laboratory effects in the signal characteristics, probably due to differences in hardware and filter settings. The presented approach, going beyond a mere replication of the traditional R&K standard, offers a continuous description of human sleep which is based on probabilistic principles. It provides a second-by-second quantification of the sleep-wake continuum and captures, although being entirely data-driven instead of rule-based, the three main processes in human sleep: wakefulness, deep sleep and REM sleep.

Adult↗

Quality control of polysomnographic sleep data by histogram and entropy analysis.

OBJECTIVE AND METHODS: Sixteen polysomnographic recordings from 8 European sleep laboratories were analyzed. The histogram analysis was used to introduce quality control of all-night EEG recordings. RESULTS: It was found that the header information does not always provide the real saturation values of the recording equipment. The entropy measure was used for the quantitative analysis of the dynamic range of routinely used polysomnographic recorders. It was found that the recording equipment provides EEG data with entropy in the range of 8-11 bits. CONCLUSION: In the all-night sleep EEG were observed non-linearities. It is recommended that the equipment provide the saturation values in order to apply automated overflow detection.

Humans↗

Artifact processing in computerized analysis of sleep EEG - a review.

Quantitative analysis of sleep EEG data can provide valuable additional information in sleep research. However, analysis of data contaminated by artifacts can lead to spurious results. Thus, the first step in realizing an automatic sleep analysis system is the implementation of a reliable and valid artifact processing strategy. This strategy should include: (1) high-quality recording techniques in order to minimize the occurrence of avoidable artifacts (e.g. technical artifacts); (2) artifact minimization procedures in order to minimize the loss of data by estimating the contribution of different artifacts in the EEG recordings, thus allowing the calculation of the 'corrected' EEG (e.g. ocular and ECG interference), and finally (3) artifact identification procedures in order to define epochs contaminated by remaining artifacts (e.g. movement and muscle artifacts). Therefore, after a short description of the types of artifacts in the sleep EEG and some typical examples obtained in different sleep stages, artifact minimization and identification procedures will be reviewed.

Artifacts↗

Neural networks for recognizing patterns in cardiotocograms.

The cardiotocogram (CTG) is commonly used for routine fetal monitoring in the delivery room. A major problem is that the interpretation of the CTG trace requires experienced specialists. In order to avoid long gaps between the detection of a suspicious pattern and the intervention, the CTG has to be checked in short intervals. An automated monitoring system at the obstetric site can reduce such delays. Therefore, an alarm system immediately reporting suspicious events has been built. The focus of our study was put on the question whether AI techniques such as neural networks are suited to the task of recognizing patterns in the CTG trace. In a comparative study, their performance was evaluated against that of conventional methods. The neural networks turned out to provide significantly better results than the tested conventional methods.

Cardiotocography↗

An artificial neural network-based noninvasive detector for suction and left atrium pressure in the control of rotary blood pumps: an in vitro study.

Rotary blood pumps are used in clinical applications to assist circulation via pumping blood from the left atrium to the aorta. Negative inflow pressures at high flow rates can cause suction of the cannula in the left atrium with deleterious effects on the atrial wall, the blood, and the lung. Therefore, stable and reliable detection of suction and the prediction of the left atrium pressure (LAP) would be of major interest for the control of these pumps. This work reports about an in vitro study of such a detector based on artificial neural networks (ANN). In the first project phase, an ANN was used to estimate the LAP based on pump speed, pump flow, and aortic pressure, obtained from a mock circulation. The inputs for the ANN were 11 characteristic values computed from these three parameters. In the second phase, another ANN was trained to classify various system states, such as suction, danger of suction (a state close to actual suction), and no suction. The first ANN was able to estimate the LAP with an accuracy of +/- 1.8 mm Hg. The discrimination of suction versus the other two states could be performed with a sensitivity and specificity of about 95% while the more interesting task of distinguishing danger of suction from no suction reached a sensitivity and specificity of about 65% (leaving 25% of each class unclassified and 10% of each class incorrectly classified).(ABSTRACT TRUNCATED AT 250 WORDS)

Atrial Function↗

On using feedforward neural networks for clinical diagnostic tasks.

In this paper we present an extensive comparison between several feedforward neural network types in the context of a clinical diagnostic task, namely the detection of coronary artery disease (CAD) using planar thallium-201 dipyridamole stress-redistribution scintigrams. We introduce results from well-known (e.g. multilayer perceptrons or MLPs, and radial basis function networks or RBFNs) as well as novel neural network techniques (e.g. conic section function networks) which demonstrate promising new routes for future applications of neural networks in medicine, and elsewhere. In particular we show that initializations of MLPs and conic section function networks--which can learn to behave more like an MLP or more like an RBFN--can lead to much improved results in rather difficult diagnostic tasks.

Coronary Disease↗

Automated interpretation of planar thallium-201-dipyridamole stress-redistribution scintigrams using artificial neural networks.

UNLABELLED: To develop an automated image interpretation system of planar cardiac 201Tl dipyridamole stress/redistribution scintigrams, the authors used artificial neural networks that associate patterns of segmental myocardial thallium uptake with a diagnostic assessment about the presence, severity and localization of significant coronary artery disease. METHODS: Artificial neural networks were trained and evaluated using the results from segmental thallium analysis and either expert readings in 159 cases or coronary angiography in a subgroup of 81 patients. RESULTS: Based on receiver operating characteristics analysis, the sensitivity for the detection of significant coronary artery disease at a specificity of 90% was 51% compared with angiography and 72% compared with the human expert. For severity and localization of disease, two vascular territories assigned to the vascular bed of the left anterior descending (LAD) artery and to the territory subtended by the left circumflex artery and the right coronary artery together (CX/RCA) were included in the analysis. CONCLUSION: Artificial neural networks may be useful to develop automated computer-based image interpretation systems of 201Tl perfusion scintigrams. However, utilization of large training datasets appears to be a prerequisite to achieve adequate diagnostic performance.

Adult↗