Search PubMed⌕ Search

Biomedical subjects

G Deutscher

Publications and source records attributed to G Deutscher.

At least 19 recordsLinked to original sources

Doping and magnetic field dependence of in-plane tunneling into YBa(2)Cu(3)O(7-x): possible evidence for the existence of a quantum critical point.

We present tunneling measurements into (1,1,0) YBa(2)Cu(3)O(7-x) films at various doping levels around the optimum. We find that, above a certain doping level near optimum doping, a spontaneous zero bias conductance peak splitting, delta, appears. It increases with doping. It also increases with magnetic field applied along the c axis, for both underdoped and overdoped films. The low field susceptibility chi = d delta /dH/(H-->0) is maximum, possibly diverging when the spontaneous value of delta goes to zero. These results suggest a transition from a pure d(x(2)-y(2)) to a d+id(xy) or d+is order parameter.

Journal Article↗

Scanning electron microscopy and X-ray diffraction studies in the analysis of medical materials: Gore-Tex versus braided polyester tape for repair of the incompetent cervix.

Cathodoluminescence in the scanning electron microscope and roentgenogram diffraction studies were applied to the analysis of two different medical materials used in cervical cerclage, the treatment of cervical incompetence. Braided polyester tape or Gore-Tex was used as suture material and was analyzed both before and after use in cerclage of the cervix. Results of SEM and X-ray diffraction studies showed distinct differences between the two materials, with the Gore-Tex demonstrating a superior morphological integrity and a decreased likelihood of phagocyte adhesion. These results correlated well with the clinical observations, which also showed Gore-Tex to be a superior medical material.

Female↗

Expanded polytetrafluoroethylene patch versus braided polyester tape for the repair of incompetent cervix.

BACKGROUND: This study was done to evaluate pregnant patients with cervical incompetence using an expanded polytetrafluoroethylene (ePTFE) patch versus the commonly used braided polyester tape, comparing the rate of local tissue reaction or onset of contractions, or both. STUDY DESIGN: This study was a prospective clinical trial on 20 patients divided into two groups. Patients having tissue reactions or contractions were identified and each material was analyzed using a new approach by means of scanning electron microscopy (SEM) and roentgenogram diffraction studies. RESULTS: In the group of pregnant patients sutured with polyester tape there were four failures because of infection and contractions. There were no direct or indirect complications encountered in the ePTFE group. Bacteriologic evaluations of the failures revealed Escherichia coli, Gardnerella vaginalis, Bacteroides species, and Trichomonas vaginalis in various combinations, in addition to crystal structure degradation and layers of phagocytes. CONCLUSIONS: Our results provide a rationale for understanding the differences in morphologic integrity and the superiority of the ePTFE patch over the polyester tape using a new analytic approach of SEM and roentgenographic diffraction studies. Because of the small number of patients and because the procedure was performed in a select patient population, we recommend that further trials be undertaken with a larger number of patients in more advanced gestational age and in patients presenting with emergent cervical incompetence.

Abortion, Spontaneous↗