Search PubMed⌕ Search

Biomedical subjects

G De Bellis

Publications and source records attributed to G De Bellis.

36 records · Page 2Linked to original sources

A more stringent choice of primers can improve the performance of fluorescent automated DNA sequencers.

Some primers frequently used in the double-stranded dideoxy DNA sequencing technique with radioactive markers are not suited for fluorescent detection. In fact oligonucleotides have a different annealing efficiency related to their base sequence, and this is reflected in nonequivalent results, particularly in fluorescent automated DNA sequencing. We present a method for the evaluation of primer performance in automated DNA sequencers and show its application to the search for a better set of primers for pBluescript vector.

Base Sequence↗

Dideoxy linear PCR on a commercial fluorescent automated DNA sequencer.

The use of automated fluorescent DNA sequencer systems and PCR-based DNA sequencing methods play an important role in the actual effort to improve the efficiency of large-scale DNA analysis. Here we show the application of the linear PCR using a single fluorescent primer and dideoxynucleotide terminators in four separate sequencing reactions on the EMBL/Pharmacia's fluorescent automated DNA sequencer. We have used dideoxy/deoxynucleoside triphosphate ratios and linear amplification cycle conditions to obtain an accurate sequencing response of up to, and over, 500 bases from just 400 ng of double-stranded DNA template without chemical denaturation. The sequencing protocol described in this paper is effectively suited for enhancement of sensitivity and performance of the automated DNA sequencing system.

Autoanalysis↗

Metabolism and pharmacokinetics of p-(3,3-dimethyl-1-triazeno) benzoic acid in M5076 sarcoma-bearing mice.

The pharmacokinetics of the anticancer agent p-(3,3-dimethyl-1-triazeno) benzoic acid (pCOOH-DMT), a drug now in phase I clinical trial in Europe, was investigated in C57Bl female mice with M5076 reticulum-cell sarcoma that were treated i.v. with 200 mg/kg pCOOH-DMT. The drug disappeared from plasma with a terminal half-life of about 2.5 h. Plasma clearance was approximately 6 ml/min per kg. Distribution studies showed some differences in drug levels in different tissues. The highest levels were found in the tumor, liver, kidney and lung; lower levels were found in the spleen and gut, and the lowest, in the brain. The N-desmethyl derivative of pCOOH-DMT was not detectable in plasma or tissues of mice treated with the drug. Therefore, the previous evidence of low N-demethylation of pCOOH-DMT was confirmed. pCOOH-DMT glucuronide was identified by mass spectrometry and quantified by high-performance liquid chromatography (HPLC) in plasma, tissues and urine samples. pCOOH-DMT glucuronide appears to be the major urinary metabolite of pCOOH-DMT in mice. Another metabolite identified by mass spectrometry and quantified by HPLC in some tissues and urine was pCOOH-DMT glycinate.

Animals↗

Development of a mass spectrometric method to quantitate platelet activating factor in mouse urine.

Platelet activating factor (PAF) is a lipid mediator of inflammation released by a variety of stimulated inflammatory cells. It may be involved in immune glomerulonephritis. Thus, its measurement in urine could give information on the mechanism of this disease. We present here a method to measure PAF in mouse urine, using gas-liquid chromatography-mass spectrometry (GLC-MS) in the selected ion recording (SIR) mode. Before instrumental analysis, the extracted and purified samples were hydrolyzed and derivatized with pentafluorobenzoyl chloride. Different experimental conditions are presented and discussed to corroborate the analytical findings. PAF levels in mouse urine were 2.08 +/- 0.46 ng/24 h. This procedure might represent a new experimental tool to establish the possible role of PAF as mediator of tissue damage in renal disease.

Animals↗

A fast atom bombardment-mass spectrometric method to quantitate lysophosphatidylserine in rat brain.

A method to quantitate lysophosphatidylserine by fast atom bombardment-mass spectrometry using 1-hexa-decanoyl-sn-glycero-3-phospho-L-serine as internal standard is described. The standard curve is linear with a correlation coefficient r2 = 0.999 from 10 to 1000 ng. This curve has been used to quantitate LPS in rat brain using phosphorus assay as a test control. We found 475 +/- 70 ng of LPS in 1 mg of tissue (n = 3). This method presents advantages due to its sensitivity and its capability to give molecular information of the unmodified compound.

Animals↗

Mechanisms of blood clotting activation in inflammation: the role of mononuclear phagocytes.

The authors review the procoagulant role of mononuclear phagocytes in the activation of blood clotting. Although the intrinsic pathway via the contact system has been considered the most important mechanism leading to fibrin formation, at least in acute inflammation, recent studies strongly suggest a role for the cells of the monocyte-macrophage series, which accumulate in the inflamed areas. These cells, when triggered in vitro by various stimuli (endotoxin, antigens, immune complexes, complement proteolytic products C5a and C3b, allogeneic leucocytes, lymphokines and others), respond with the production of selected procoagulant activities, thereby initiating the coagulation pathways. The most commonly described procoagulant activity has been identified as tissue factor, although prothrombinases and factor X activators have been reported. In addition mononuclear phagocytes can also produce and/or assemble on their surface coagulation factors including f. II, VII/VIIa, IX, X/Xa and V. Available evidence indicates that monocytes/macrophages can respond to appropriate signals and acquire the capacity to activate blood coagulation in vivo also. These "activated" cells expressing procoagulant activity appear to be directly responsible for the local fibrin deposition observed at sites of endotoxin-induced inflammation, of tumours, of cell-mediated immune reactions and possibly of other inflammatory processes.

Blood Coagulation↗

Serological markers of hepatitis B virus infection in healthy volunteer blood donors in Campania (Southern Italy).

The prevalence of hepatitis B virus (HBV) serological markers was determined in a prospective fashion by radioimmunoassay in 2,084 healthy volunteer blood donors. The results showed that 51.2% of the donors were positive for at least one marker, and the percentage of occurrence of each marker was: HBsAg 5.3, anti-HBs alone 1.7, anti-HBc alone 10.8, anti-HBs and anti-HBc 33.3. Because of the size of the problem this investigation strongly demands further studies on the potential role of blood positive for anti-HBc in transmitting HBV infection in our geographical area.

Adolescent↗

[Serum levels of GPI, AAT and CEA in primary lung neoplasms and chronic bronchopneumopathies].

The Authors have tested serum levels of alpha-1-antitrypsin (A1AT), phosphohexose-isomerase (GPI) and carcinoembryonic antigen (CEA) in 133 patients affected with primary lung cancer, not treated with any drug, and in 183 patients affected with not neoplastic lung diseases or healthy, to control the utility of these markers in the early diagnosis of lung cancer. In many patients all the tests have been made at the same time. The three tumoral markers have been also examined in connection with the histological kinds of lung cancer. Results show that is suitable to test GIP and A1AT at the same time because they are percentually more pathological; serum levels of CEA, that are not very elevated in the pathological cases, seem in correlation with the histological kind of cancer.

Bronchial Diseases↗

[Behavior of HBs Ag and HBs Ab in chronic hepatitis].

The preliminary results of the HB, Ag and HBs Ab assay, performed with radioimmunological techniques in 31 cases of chronic hepatitis, 13 of whom carriers of chronic aggressive hepatitis (C.A.H.), 9 of chronic persistent hepatitis (C.P.H.) and 9 of cryptogenetic hepatic cirrhosis (C.H.C.) of both sexes, are reported. The highest number of HBs Ag positive cases was observed both in C.A.H. (69%) and C.H.C. (55%); very lower the HBs Ag positivity both in C.A.H. (33%) and C.H.C. (33%). No correlation between HBs Ag positive and HBs Ab positive was observed.

Antibodies, Viral↗

[Radioimmunologic determination and analysis for saturation of the thyroid hormones: comparison and use in the practical clinic].

Reliability of a recent method of assay by saturation analysis for assessment of thyroid status, which is to be recommended for its practicability and technical improvement, has been verified. Its diagnostic efficiency in more than 3,000 assays has been evaluated. On the whole T3 Uptake (T3U) and serum Thyroxine (T4D) determination showed a quite good accuracy, that decidely improved when both the tests were carried out and the Free Thyroxine Index (Free Thyopac Index) was drown. Moreover the present availability of the radioimmunological determinations of triiodothyronine allowed to assay simultaneously both thyroid hormones in normal euthyroid subjects, in pregnancy, in hyperthyroid, hypothyroid and goitrous patients. Results obtained have been analysed and discussed and clinical conditions pointend out where determination of both hormones may be useful.

Cross Reactions↗

[Incidence of HBAg in various liver diseases (comparison between radioimmunologic methods and methods of passive hemagglutination)].

In order to determine the frequency of HBAg in Campania, the AA. have examined a large number of liver patients accurately selected and subdivided in five classes: acute hepatitis, chronic hepatitis, cirrhosis, hepatocarcinoma, and various liver diseases. They have employed radioimmuno assays (RIA) with human and guinea pig antibodies and techniques of passive haemoagglutination. The percentage of HBAg positive subjects among the various classes of liver diseases determined with these techniques is significantly higher than the one remarked by the AA. in 1972 by electrosineresis on the same population. Both RIA and haemoagglutination supply satisfactory results, although for haemoagglutination one must remember the subjectiveness of the reading.

Antibody Formation↗

The role of ranitidine infusion on glucose, insulin and C-peptide serum levels induced by oral glucose tolerance test in healthy subjects.

In 9 healthy subjects we evaluated the effect of a constant ranitidine infusion (100 mg) on glucose (mg/dl), insulin (microU/ml) and C-peptide (ng/ml) serum levels promoted by oral glucose tolerance test (75 g). Ranitidine significantly increased the area under concentration/time curves for glucose and insulin but not that of C-peptide. Our data indicate that ranitidine does not affect pancreatic insulin release nor peripheral glucose utilization and are consistent with the hypothesis that ranitidine influences the hepatic clearance of glucose and insulin both of which undergo high first-pass liver extraction.

Administration, Oral↗