The pharmacokinetic behaviour of cytisine was studied in mice by means of tritiated cytisine after intravenous and oral administration of a sublethal dose of 2 mg/kg. After oral administration the maximum blood level is reached after 2 h. The absorption rate is approximately 42%. From the blood level after intravenous administration a half-life of 200 min was calculated. Within 24 h after intravenous administration 32% and after oral administration 18% of the administered radioactivity was excreted into urine. Following intravenous administration 3% of the dose was found in the faeces within 6 h. Among the examined organs and tissues the highest concentrations were reached in the liver, adrenals and kidneys. In the bile the highest concentration after intravenous administration was 200 times that in the blood.

Alkaloids↗

The influence of drugs on the acute toxicity of cytisine.

The effect of various drugs on the acute toxicity of cytisine, the toxic constituent of Laburnum anagyroides Med, was studied in mice. Drugs were tested which have been recommended for symptomatic treatment of laburnum poisoning. Drugs which influence the CNS reduce the acute toxicity of cytisine more effectively than those with predominantly peripheral site of action.

Alkaloids↗

The Baylor total artificial heart. Flow visualization studies.

To analyze the flow patterns of the left blood chamber of the Baylor total artificial heart (TAH) and to evaluate influences of the inflow valve angle to the flow patterns, flow visualization studies were performed. The inflow valve angle of the left housing was changed by 20 degrees orthogonal to the inflow tube, and comparison studies of the modified and unmodified models were made. For evaluating sectional flow patterns, a laser light was used, the clear transparent housing was scanned segmentally, and flow patterns were recorded on high contrast film for measuring flow velocities. A signal was used that synchronized the timing of the camera shutter to the pusher-plate movement signal. With the modified 20 degree inflow valve direction, there were better closing characteristics of the inflow valve leaflets. At the same time, we could successfully reduce the vortex formation at the inflow port, which may cause thrombus formation. We also have improved the washout during the diastolic phase in not only the bottom area, but in the entire pumping chamber. This flow visualization setup is simple and inexpensive. It is useful not only for validation of global flow patterns, but also for validation of local flow velocities of various blood pumps.

Biomedical Engineering↗

The Baylor-ABI electromechanical total artificial heart. Accelerated endurance testing.

To test the durability of each part or assembled component of the Baylor-ABI total artificial heart (TAH), the authors performed an endurance test under severe conditions. The TAH was immersed in a saline bath at 42 degrees C, which is 4-5 degrees C higher than normal body temperature. This is an accelerated endurance test because of the elevated temperatures. In this accelerated endurance test loop, the 42 degrees C heated saline was circulated not only in the pump but also outside the pump. During pumping, temperatures of the motor and outside surface of the centerpiece were continuously measured. This testing showed that during almost 4 months of pumping no electromechanical troubles were observed. Both inside (motor) and outside temperatures were stable and the differences in both temperatures were only 3-4 degrees C, demonstrating that heat generation is not a problem. The voltage and current required in this system remained constant, indicating stable and reliable performance. Based on these results, this pump is expected to run continuously over a long duration in a normal physiologic environment. This accelerated endurance test system is very suitable for estimating the influence of heat generation by the actuator of blood pumps. It is also quite useful in validating the durability of various cardiac prosthesis.

Heart, Artificial↗