Search PubMed⌕ Search

Biomedical subjects

G D Causey

Publications and source records attributed to G D Causey.

13 recordsLinked to original sources

Normative data in quiet, broadband noise, and competing message for Northwestern University Auditory Test No. 6 by a female speaker.

Two descriptive experiments were performed on a version of the Northwestern University Auditory Test No. 6 (NU No. 6) recorded by a female speaker that is included on an audio compact disc recently produced by the Department of Veterans Affairs. In Experiment 1, normative psychometric functions for the female speaker version of the NU No. 6 materials were established on 24 young adults for three monaural listening conditions (in quiet, in 60-dB SPL broadband noise, and in 60-dB SPL competing message). The 60-dB SPL broadband noise shifted the psychometric function for the NU No. 6 words 33 dB, whereas the 60-dB SPL competing message shifted the function only 18-22 dB. In contrast to the slopes of the quiet and noise conditions (4.5%/dB), the slope of the competing message function was more gradual (3.5%/dB). In Experiment 2, comparisons between the psychometric functions for the female and the original male speaker versions of NU No. 6 in quiet and in broadband noise were made on 8 young adults. In comparison to the psychometric functions for the male speaker version of NU No. 6, the functions for the female speaker version of NU No. 6 were displaced between the 10-90% correct points to higher sound-pressure levels by 10-13 dB in quiet and by 12-16 dB in noise. The difference in performance on the two versions of NU No. 6 is attributed to spectral differences between the two sets of materials that produced a calibration anomaly.

Adult↗

The Maryland CNC Test: normative studies.

These studies were conducted to determine the performance-intensity functions of the Maryland CNC Test (male voice) with normal-hearing and hearing-impaired persons, to examine the equivalence of the 10 lists, and to determine test-retest reliability. There was a 2.1% increase per decibel in word recognition in the linear portion of the performance-intensity function for normal listeners and a 1.3% increase per decibel for hearing-impaired listeners. 6 lists were judged to be equivalent, and there was good test-retest reliability. Hearing-impaired subjects demonstrated a wide range of scores on the Maryland CNC Test, suggesting that this measure can distinguish among varying degrees of word recognition ability.

Acoustic Stimulation↗

A comparative evaluation of the Maryland NU 6 auditory test.

This study was conducted to determine the performance-intensity functions of the Maryland NU 6 Auditory Test (female voice) with normal-hearing and hearing-impaired persons, to examine equivalency of the four lists, and to compare performance scores on this test with those obtained on the CID W-22 Test and the Maryland CNC Test. Three lists were judged to be equivalent, and there was good test-retest reliability. The test made distinctions among individuals with varying degrees of high-frequency hearing loss. Word recognition scores for the Maryland NU 6 and Maryland CNC Tests were remarkably similar, but differed significantly from those obtained on the W-22 Test.

Adult↗

Measurement of attack-release times in compression hearing aids.

A system for measurement of attack-release times in hearing aids with automatic-gain-control circuitry is described, with a view toward implementing that portion of the ANSI S3.22-1976 Standard in which parameters for these measurements are specified. Signal generation is accomplished by using a phased-array loudspeaker arrangement designed to produce transient-free pulsed acoustic sinusoids. Output waveforms are captured by a commercial transient recorder, and are displayed in either an oscilloscopic or graphic mode. A specific means of calculating attack and release times is recommended whereby variously shaped output waveforms are amenable to the basic protocol outlined in the ANSI Standard.

Acoustics↗

Hearing aids.

Explore the source record for details and available documents.

Hearing Aids↗

The influence of hearing aid nonlinear distortion on two auditory tasks.

A study is reported which examines the influence of hearing aid nonlinear distortion on multitone pitch perception. Normal-hearing subjects produced results indicating that hearing aid-generated harmonic and intermodulation components did significantly affect pitch judgments. Substantial differences in the amount of distortion between the two test aids was not, however, a critical factor. A follow-up study using closed-set intelligibility materials in noise further confirmed that relatively large measurable differences in nonlinear distortion between hearing aids do not seem to have the clinical significance which is often presumed.

Adult↗

The relative importance of recovery time in compression hearing aids.

Recovery time (RT) in compression hearing aids was studied using six aids of identical characteristics except for factory-modified RT. Recordings of CID W-22 lists were made through the aids and played to normally hearing and otopathologic (sensorineural) subjects. Speech intelligibility was measurably influenced by RT variation with attack time held constant (10 ms). The effect was much more pronounced with the normal than with the hearing-impaired listeners, a phenomenon not unexpected when testing such a subtle feature in a low-fidelity transmission system. When the RTs of the aids were respecified according to a proposed standard (IEC) the data suggested that RTs for English in the vicinity of 90 ms may be most desirable. Additional work is required using more complex stimuli and background noise.

Auditory Perception↗

Nonlinear distortion in hearing aids: the need for reevaluation of measurement philosophy and technique.

Conventional pure-tone tests of harmonic distortion are of dubious sufficiency in expressing the nonlinear distortion (NLD) characteristics of hearing aids. This paper reviews the strategies and problems of intermodulation distortion. Spearman rank order correlations for a group of hearing aids varied widely as a result of changes in the selected frequency and/or level of input signal. Also, the reference criteria for expressing distortion was observed to contribute to the inconsistency of rank order impression. A technique is described which incorporated synthetic vowels as test signals. Hearing aid outputs were studied on a spectrum analyzer for evidence of NLD. It is argued that efforts should be directed at devising tests for hearing aids which are directed at comprehensive NLD including both harmonic distortion and intermodulation distortion.

Evaluation Studies as Topic↗