Search PubMed⌕ Search

Biomedical subjects

G Cincotti

Publications and source records attributed to G Cincotti.

5 recordsLinked to original sources

Frequency decomposition and compounding of ultrasound medical images with wavelet packets.

Ultrasound beams propagating in biological tissues undergo distortions due to local inhomogeneities of the acoustic parameters and the nonlinearity of the medium. The spectral analysis of the radio-frequency (RF) backscattered signals may yield important clinical information in the field of tissue characterization, as well as enhancing the detectability of tissue parenchymal diseases. In this paper, we propose a new tissue spectral imaging technique based on the wavelet packets (WP) decomposition. In a conventional ultrasound imaging system, the received echo-signals are generally decimated to generate a medical image, with a loss of information. With the proposed approach, all the RF data are processed to generate a set of frequency subband images. The ultrasound echo signals are simultaneously frequency decomposed and decimated, by using two quadrature mirror filters, followed by a dyadic subsampling. In addition, to enhance the lesion detectability and the image quality, we apply a nonlinear filter to reduce noise in each subband image. The proposed method requires simple additional signal processing and it can be implemented on any real-time imaging system. The frequency subband images, which are available simultaneously, can be either used in a multispectral display or summed up together to reduce speckle noise. To localize the different frequency response in the tissues, we propose a multifrequency display method where three different subband images, chosen among those available, are encoded as red, green, and blue intensities (RGB) to create a false-colored RGB image. According to the clinical application, different choices can evidence different spectral proprieties in the biological tissue under investigation. To enhance the lesion contrast in a grey-level image, one of the possible methods is the summation of the images obtained from narrow frequency subbands, according to the frequency compounding technique. We show that by adding the denoised subband images created with the WP decomposition, the contrast-to-noise ratio in two phantom images is largely increased.

Image Processing, Computer-Assisted↗

Optimization of wide-band linear arrays.

An optimization method is proposed for linear arrays to be used in ultrasound systems under wide-band operation. A fast algorithm, the threshold accepting, has been utilized to determine the element positions and weight coefficients of a linear array that generates a desired beam pattern. To reduce the computational burden in the optimization procedure, an efficient numerical routine for the beam pattern evaluation has been implemented. We address the optimization problem of both dense and sparse wide-band arrays. In the first case, the goal is to minimize the side-lobe energy by varying the element weights; we compare the optimized beam pattern with that obtained with classical shading functions, showing that better results can be achieved with a wide-band optimization. We also consider the optimization of the layout (positions and weights) of a sparse linear array to achieve a desired beam pattern with a fixed or minimum number of array elements. The comparison of the proposed method with a narrow-band optimization algorithm is presented, showing that better performances (about -7 dB further reduction of the side-lobe level) can be achieved with a wide-band sparse array optimization. Further numerical simulations are given, showing that the proposed method yields better results than wide-band sparse random arrays and periodic arrays with the same aperture width.

Journal Article↗

A novel approach to the aperture windowing in medical imaging.

A new technique is proposed to improve the lateral resolution in the conventional B-mode imaging systems, which enables a simple array aperture windowing in the transmitting mode. Amplitude shaping is performed without modifying the transmitting voltage of the array elements, but only varying the excitation pulse length from one element to another. This method presents some attractive practical advantages, and the reduction of the sidelobe energy is comparable to that attainable with a conventional aperture windowing. Parametric plots are given, which transform an amplitude apodization into a 'time apodization' for any type of transducer array.

Ultrasonography↗

A new beamforming technique for ultrasonic imaging systems

We propose a simple, versatile and inexpensive beamforming method that performs the aperture windowing of an ultrasonic transducer array in the transmit mode, without modifying the driver voltage, but simply controlling the length of the electric pulse driving the array elements. A conversion formula has been determined that permits us to compute, for a desired emitted pulse amplitude, the corresponding driving pulse length to be applied. Any shading function can be implemented over any type of transducer array, using very low-cost hardware. Computer simulations and experimental measurements, with a 3.8 MHz convex array, confirm the effectiveness of this approach in enhancing the contrast resolution, since the off-axis intensity in the radiated beam pattern is largely reduced.

Journal Article↗

Diffractive variable beam splitter: optimal design.

The analytical expression of the phase profile of the optimum diffractive beam splitter with an arbitrary power ratio between the two output beams is derived. The phase function is obtained by an analytical optimization procedure such that the diffraction efficiency of the resulting optical element is the highest for an actual device. Comparisons are presented with the efficiency of a diffractive beam splitter specified by a sawtooth phase function and with the pertinent theoretical upper bound for this type of element.

Equipment Design↗