Search PubMed⌕ Search

Biomedical subjects

G C Filligoi

Publications and source records attributed to G C Filligoi.

11 recordsLinked to original sources

Influence of high motor unit synchronization levels on non-linear and spectral variables of the surface EMG.

The aim of this study was to investigate the influence of high degrees of motor unit synchronization on surface EMG variables extracted by linear and non-linear analysis techniques. For this purpose, spectral and recurrent quantification analysis (RQA) were applied to both simulated and experimental EMG signals. Synthetic surface EMG signals were generated with a model of volume conductor comprising muscle, fat, and skin tissues. The synchronization was quantified by the percent of discharges of each motor unit synchronized with discharges of other motor units. The simulated signals presented degrees of synchronization in the range 0-80% (10% increments) and three mean values of motor unit conduction velocity distribution (3, 4 and 5 m/s). Experimental signals were collected from the first dorsal interosseous muscle of five patients with Parkinson disease during 10s of rest and 10s of isometric voluntary contraction at 50% of the maximal force. Mean power spectral frequency (MNF) and percent of determinism (%DET) of the surface EMG were computed from the simulated and experimental signals. In the simulated signals, %DET was linearly related to the level of synchronization in the entire range considered while MNF was sensitive to changes in synchronization in a smaller range (0-20%), outside which it levelled off. The experimental results indicated that %DET was significantly higher in the resting condition (with presence of tremor; mean +/- S.E., 85.4 +/- 0.8%) than during the voluntary contraction (which partly suppressed tremor; 60.0 +/- 2.3%; P < 0.01). On the contrary, MNF did not depend on the condition (114.3 +/- 1.5 Hz and 118.0 +/- 0.8 Hz for the resting and voluntary contraction, respectively), confirming the simulation results. Overall, these results indicated that linear and non-linear analyses of the surface EMG may have different sensitivities to the underlying physiological mechanisms in specific conditions, thus their joint use provides a more complete view of the muscle status than spectral analysis only.

Action Potentials↗

Linear and non-linear analysis of surface electromyograms in weightlifters.

The present research was aimed at investigating the peculiarities of surface electromyogram (sEMG) signals in 12 weightlifting athletes (WLA) and 9 control subjects (control group, CG) The sEMG signals were recorded from both vastus lateralis muscles during 20 s isometric contractions made at 30% and 60% of the maximal voluntary contraction (MVC). Ground reaction force (vertical component) was recorded using a force plate. The sEMG was analysed in the frequency domain and the median frequency (MDF) was computed over successive 1 s epochs. A non-linear technique, recurrence quantification analysis was also applied to assess the presence and time course of deterministic structures in sEMG. The percentage of determinism (%DET) was used as a synthetic parameter to quantify the amount of regularly repeating sEMG waves within the signal itself (bursts). In 5 WLA the sEMG displayed a clear burst activity centred at 11 Hz. These bursts were correlated with force output oscillations and were evident both at 30% and 60% MVC. The MDF decay with time was more evident in WLA than in CG subjects. The %DET increased in WLA, this increase being more evident during 60% MVC contractions. Our results seemed to suggest a special disposition among WLA for the development of long-term changes in firing probability during sub-maximal isometric exercise. The MDF and %DET data provided indications of a greater involvement of fast twitch muscle fibres in WLA than in CG.

Adult↗

Spatial and temporal distribution enhancement of movement-related brain macropotentials.

Conventional brain maps suffer from severe limitations due to both the spatial blur of potential distributions and the dependence on electrical reference. The surface Laplacian (SL) has been used to deblur movement-related brain macropotentials (MRBM) since it acts as a high-pass spatial filter that reduces the head volume conductor effects. Moreover, the method usually employed to improve the signal-to-noise ratio (SNR) is the well-known synchronized average. However, this method is no longer valid when the object of the study is the sweep-by-sweep variability. In this case, the SNR of original and Laplacian-transformed single-sweep MRBM can be improved by autoregressive with exogenous input (ARX) filtering. In our study, isolated or combined ARX and SL are applied to enhance the spatial distributions of single-sweep MRBM associated with unilateral voluntary self-paced finger movements in humans. It shows that single-sweep brain mappings are more coherent to physiological findings when ARX is first used followed by SL.

Algorithms↗

Computerized color perimetry in multiple sclerosis.

Color visual field analysis has proven highly sensitive for early visual impairments diagnosis in MS, yet it has never attained widespread popularity usually because the procedure is difficult to standardize, the devices are costly, and the test is fatiguing. We propose a computerized procedure running on standard PC, cost effective, clonable, and easy handled. Two hundred and sixty-four colored patches subtending 1 degree angle vision, with selected hues and low saturation levels are sequentially and randomly displayed on gray equiluminous background of the PC screen subtending 24 degrees x 40 degrees angle of vision. The subject is requested to press a switch at the perception of the stimulus. The output provides colored maps with quantitative information. Comparison between normals and a selected population of MS patients with no actual luminance visual field defects, showed high statistical difference.

Adolescent↗

Color perimetry with personal computer.

Color visual field analysis has proven highly sensitive for early visual impairments diagnosis in M. S., yet it has never attained widespread popularity usually because the procedure is difficult to standardize, the devices are costly, and the test is fatiguing. We propose a computerized procedure running on standard PC, cost effective, clonable, and easy handled. 264 colored patches subtending 1 degree angle of vision, with selected hues and low saturation levels are sequentially and randomly displayed on gray equiluminous background of the PC screen subtending 24 degrees x 40 degrees angle of vision. The subject is requested to press a switch at the perception of the stimulus. The output provides colored maps with quantitative informations. Comparison between normals and a selected population of Patients with Multiple Sclerosis and with Glaucoma without luminance visual field defects, showed high statistical difference.

Adult↗

On-line analysis of AEP and EEG for monitoring depth of anaesthesia.

Achieving and monitoring adequate depth of anaesthesia is a challenge to the anaesthetist. With the introduction of muscle relaxing agents, the traditional signs of awareness are often obscured or difficult to interpret. These signs include blood pressure, heart rate, pupil size, etc. However, these factors do not describe the depth of anaesthesia, (DA), in a cerebral activity sense, hence there is a desire to achieve a better measure of the DA. Auditory Evoked Potentials (AEP) provide two aspects relevant to anaesthesia: (1) they have identifiable anatomical significance and, (2) their characteristics reflect the way in which the brain reacts to a stimulus. However, AEP is embedded in noise from the ongoing EEG background activity. Hence, processing is needed to improve the signal to noise ratio. The methods applied were moving time averaging (MTA) and ARX-modeling. The EEG was collected from the left hemisphere and analysed by FFT to 1 sec epochs and the spectral edge frequency was calculated. Both the changes in ARX extracted AEP and the spectral edge frequency of the EEG correlated well with the time interval between propofol induction and onset of anaesthesia measured by clinical signs (i.e., cessation of eye-lash reflex). The MTA extracted AEP was significantly slower in tracing the transition from consciousness to unconsciousness.

Anesthesia↗

Reduction of ocular artefacts in source current density brain mappings by ARX2 filtering.

Sweep by sweep analysis of event-related potentials (ERP) of the human scalp represents a reliable tool for both the diagnosis of neurologic diseases and the study of the central nervous system during cognitive tasks. The off-line procedure based on stochastic parametric identification and filtering herewith described, allows an accurate analysis of single-sweep ERP and a drastic reduction of ocular artefacts variously propagating through the skull. Moreover, the spatial distribution of the recorded ERP in bidimensional form was enhanced by using the Laplacian operator in order to get an estimate of the source current density (SCD) flow from the skull into the scalp. Complete single-trial signals were filtered according to an autoregressive model of signal generation with 2 exogenous inputs (ARX2). The ARX2 procedure models the recorded signal as the sum of three signals: (a) the background EEG activity, modelled as an autoregressive process driven by a white noise; (b) a filtered version of a reference signal carrying the average information contained in each sweep; (c) a signal due to the ocular artefact propagation. The evaluation of the effect of artefact suppression on those channels close to the eyes was compared with standard ordinary least squares method (OLS) based on a linear model of the influence of EOG on ERP. Finally, the better results obtainable through ARX filtering on sweep-by-sweep brain mappings are also presented.

Adult↗

ARX filtering of single-sweep movement-related brain macropotentials in mono- and multi-channel recordings.

A technique of stochastic parametric identification and filtering is applied to the analysis of single-sweep event-related potentials. This procedure, called AutoRegressive with n eXogenous inputs (ARXn), models the recorded signal as the sum of n+1 signals: the background EEG activity, modeled as an autoregressive process driven by white noise, and n signals, one of which represents a filtered version of a reference signal carrying the average information contained in each sweep. The other (n-1) signals could represent various sources of noise (i.e., artifacts, EOG, etc.). An evaluation of the effects of both artifact suppression and accurate selection of the average signal on mono- or multi-channel scalp recordings is presented.

Brain Mapping↗

Automatic visual field: a software diagnostic procedure.

A recently developed technique for the automatic acquisition of data on visual field losses was tested, with reliable neuro-ophthalmological parameters, on 300 subjects with and without eye disorders. Algorithms for acquisition and processing of the central visual field were implemented on an IBM-AT personal computer with standard peripherals. The contours of scotomata (visual field losses) were best estimated by probabilistic adaptive enhancement of data sampling in those areas with greater visual variability. Image processing tools were specially designed to extract information concerning the size, shape, position and number of scotomata in the visual field. The diagnosis of wider campimetric lesions required parameters such as symmetry or specularity coefficients, obtainable by analysing the visual field of both eyes. Data obtained were correlated to the pathology involved by univariate statistical tools.

Algorithms↗